OPTIONAL FEATURES 30 WWW.MACGEN.CO.UK



Similar documents
TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Atlas Copco Generators

Magnum Mobile Generator MMG55 Specifications

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Generating Set

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TMS TANK MANAGEMENT SYSTEM

Annex-A TECHNICAL SPECIFICATION

POWERING THE WAY Rental Power Planner

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

The kva RAnge

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

SMS GSM Alarm Messenger

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

GENERATOR TRANSFER SWITCH

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

OT 40L / 90L. Laboratory Steam Sterilizers

Signature and ISX CM870 Electronics

Diesel Engine Driven Generators Page 1 of 6

Power Generation. Power Control PCL System Generator Set Control

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Options and monitoring

PowerCommand iwatch 100

Marine Generating Sets 3.7 to 50 kva

Nu-Lec Training Modules

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Product Specification instalert Rapid Messenger Variable Message Sign

Hardware & Software Solutions

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

PowerGem Pro Uninterruptible Power Supply

Waterproof portable tracker and

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

SMS Alarm. User Manual

E. Fowler & Sons Ltd.

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

PowerCommand iwatch 100 Remote Network Monitoring

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

Spark-ignited generator set

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

AUTOMOTIVE AIR CONDITIONING SYSTEM.

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Heating and Hot Water Services Controls General Technical Specification

S100. GSM House Alarm System.

USER MANUAL Online UPS 1K/2K/3K Rack

WANCO PVS PORTABLE VIDEO SURVEILLANCE Portable Security & Surveillance

STERILIZERS, LABORATORY DRYING OVENS

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

GSM HOME SECURITY SYSTEM

Phase Modular Finally the benefits of Modular ups are for all

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Memcom Emergency Telephone

In VehIcle MonItorIng SolutIonS

A Practical Guide to Free Energy Devices

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Combined Cycle Control Overview

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Paralleling Switchgear

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

GPS Tracking Solution GPS GSM Tracker

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Project Breakdown - Remote Monitoring

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

Oil and Coolant Circulating Heating System. Model - OCSM

User Manual WatchPower

Configurable Events for APC Network Management Card

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Business/ Home GSM Alarm System

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Fleet Telematics Solution

ECOCIAT. Domestic hot water heat recovery unit

How to read this guide

Standard WIRED Installation Guide

REMOTE START SECURITY SYSTEM OWNERS MANUAL

Monitoring Remote Chemical Tanks

MIDNITE SOLAR AND SOLAR WASHINGTON

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

SSPI-APPN OTES: PARALLEL C ONNECTIONS

sat-nms SMU Signal Management Unit

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Digital generator set 1302 control kit

Back-UPS Pro 1300/1500 Installation and Operation

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Process Alarm Solutions

Transcription:

OPTIONAL FEATURES 30

OPTIONAL FEATURES. Mobile Trailer Units The MacGen range of generator units are available on mobile road-tow chassis up to 00kVA. Fully galvanised and constructed from folded steel, these units provide much needed portability where necessary. Supplied with all electrical lights and connections and a choice of towing hitches, the mobile generator is ready to move whenever it is needed, supplying reliable power in the most flexible way. Weight restrictions may apply.. Auto Start Packages The AMF/ATS panel is used to monitor a mains supply and automatically start the standby generator in the event of a mains power failure. The module also provides indication of operational status and fault conditions, automatically shutting down the generator and indicating failures by means of the LCD display and appropriate flashing LED on the front panel. Selected timers and alarms can 3 be altered by the customer from the front panel. The interface also provides real time diagnostic facilities. Synchronizing options also available. 3. 3-Way Fuel Valve Kits This kit enables the user to select a fuel source either from the generators own internal bunded tank or an appropriate external tank via the valve. The kit is also supplied with non-return, quick-release fittings available in either /, 3/8 or / sizes.. Water Fuel Pre-Filter Due to different fuel qualities or possible condensation build up in large external storage tanks a certain amount of water can occur in the fuel system. The water fuel pre-filter separates this water from the diesel in order to avoid the water damaging the injection system and engine.. Distribution Boxes Distribution boxes are available on all soundproof generators, excluding the MPG3 model, with a large and varied range of socket configurations from 6amp to amp. 3

6. High Capacity Fuel Tank This steel-bunded, high-capacity fuel tank significantly increases the fuel capacity of the generator over the standard version. 6 These tanks are available for the complete soundproof range. Sizes available from 00 to 3960 litres (model dependant). 7. Electronic Governor The electronic governor regulates the generator s engine speed. Due to its rapid response to load demand changes, it can maintain the generator's output frequency much more efficiently, especially when working within narrow limits such as computer hardware or electronic plant equipment. 7 8. Lift and Drag Skids The lift and drag skids are designed to allow the user more flexibility when positioning the generator on site. In addition to the lifting hook and fork truck pockets, the drag skid allows the unit to be pulled into position. It also protects the chassis and canopy from damage caused by small machinery as the base protrudes outwards from the main canopy frame. 8 9. Battery Trickle Charger After prolonged period of inactivity batteries can discharge. The battery trickle charger prevents this discharge from occuring by keeping the batteries charged to their maximum capacity. When maximum capacity is achieved, the battery trickle charger switches off until it is next required (external power source required). 0. Switchable Dual Frequency The MacGen generator range is supplied with 0Hz as standard. However they can be reconfigured to provide both 0 and 60Hz 9 through a combination of adjustments to the MacGen CEM controller and the engine. Other options are available on request including: Programmable Timer: The programmable timer informs the controller about the current date and time which in turn allows the weekly programming of events such as programmed start and stop, programmed blocking, failure data log, energy counters (day, month, year). Marine Alternator: This additional protective coating can be added to the main alternator to protect it from the harshest environments. Battery Isolator: The battery isolator is normally located within the engine compartment of the generator its primary purpose being to isolate all power from the batteries to the controller. Water Jacket Heater: This thermostatically controlled unit warms the engine coolant allowing the generator to start and accept load quicker. Low Water Level Sensor: This unit will automatically shutdown the engine when the coolant level reaches its minimum mark. Customised Color: The complete range of generators can be customised to meet any bespoke company branding and aesthetics. 0 3

COMMUNICATIONS OPTIONS FOR OFFSITE MONITORING AND MANAGEMENT. Repetitive Visualisation Display This remote display acts as a second viewer allowing the user to monitor and control the generator via a hard wire connection up to km.. CAN-LAN monitoring Similar to the CAN-BUS system but connection is made via Ethernet, which allows any PC connected to the same network to control and monitor the generator.. MPS.0 Synchronising Control System The MPS module allows up to 8 generators to be linked together for the purpose of synchronization and load sharing. 3 6. GSM Modem Remote Monitoring Allows the user full control and monitoring of the generator from a PC connected to a GSM/Cellphone network, it can also send an SMS text alert informing start/stop of the generator to a mobile phone.* 3. CAN-BUS monitoring This option allows the user full control and monitoring of the generator from a PC via CAN-USB connection up to km away (achieved through hard wire connection). 6. Internet Remote Monitoring This option allows the user full control and monitoring of the generator from a PC connected to the internet.* * ADDITIONAL 3RD PARTY INTERNET OR MOBILE CHARGES WILL APPLY 33

COMMUNICATIONS OPTIONS FOR OFFSITE MONITORING AND MANAGEMENT. Repetitive Visualisation Display This remote display acts as a second viewer allowing the user to monitor and control the generator via a hard wire connection up to km.. CAN-LAN monitoring Similar to the CAN-BUS system but connection is made via Ethernet, which allows any PC connected to the same network to control and monitor the generator.. MPS.0 Synchronising Control System The MPS module allows up to 8 generators to be linked together for the purpose of synchronization and load sharing. 3 6. GSM Modem Remote Monitoring Allows the user full control and monitoring of the generator from a PC connected to a GSM/Cellphone network, it can also send an SMS text alert informing start/stop of the generator to a mobile phone.* 3. CAN-BUS monitoring This option allows the user full control and monitoring of the generator from a PC via CAN-USB connection up to km away (achieved through hard wire connection). 6. Internet Remote Monitoring This option allows the user full control and monitoring of the generator from a PC connected to the internet.* * ADDITIONAL 3RD PARTY INTERNET OR MOBILE CHARGES WILL APPLY 33