40/100 Gb/s Ethernet Over Multi-mode Optical Fiber Planning for Infrastructure Readiness. Alfred Flores Vice Chair, Fiber Optics LAN Section

Similar documents
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

How To Make A Data Center More Efficient

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Data Center Design for 40/100G

TIA Fiber Optics LAN Section (FOLS) LAN Standards, News & Trends Report

Upgrading Path to High Speed Fiber Optic Networks

GIGABIT ETHERNET. Greg Hankins UKNOF16. v /04/22

CISCO 10GBASE X2 MODULES

Arista 40G Cabling and Transceivers: Q&A

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Fiber in the Data Center

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

How To Get A Better Signal From A Fiber To A Coax Cable

Your Network. Our Connection. 10 Gigabit Ethernet

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

The ABC of Direct Attach Cables

Overcoming OM3 Performance Challenges

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

The 8-Fiber Solution for Today s Data Center

Intel Ethernet SFP+ Optics

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

100 GBE AND BEYOND. Greg Hankins NANOG52. Diagram courtesy of the CFP MSA. NANOG /06/14

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

The Need for Low-Loss Multifiber Connectivity

40 and 100 Gigabit Ethernet Overview

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

Laser-Optimized Fiber

Fiber Selection and Standards Guide for Premises Networks

Ethernet 102: The Physical Layer of Ethernet

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

With the advent of Gigabit Ethernet

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Low Cost 100GbE Data Center Interconnect

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Parallel SMF (PSM) in the Data Centre

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Trends In Data Rate And Link Length In Evolving Optical Standards

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Reliable, Consistent, Quality

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Local Area Networks. Guest Instructor Elaine Wong. Elaine_06_I-1

Network Topologies and Distances

Data Center Fiber Cabling Topologies and Lengths. Paul Kolesar IEEE HSSG, September 2006

How To Make A Fibre Cable For A Data Centre

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

100BASE-SX Fast Ethernet:

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

Data Center Cabling Technology and Trends

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

10G and Beyond in the Data Center with OM3 Fiber

Fibre Channel Fiber Cabling

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems

White Paper. MPO/MTP Introduction to Parallel Optics Technology

As today s evolving data centers

Cisco 10GBASE SFP+ Modules

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Prisma IP 10 GbE VOD Line Card

How To Properly Maintain A Fiber Optic Infrastructure

Ethernet/IEEE evolution

Attaching the PA-A1-ATM Interface Cables

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

Gigabit Ethernet Copper-to-Fiber Converters

Loss & Continuity Testing with MPO/ MTP Connectors

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Cisco SFP Optics for Gigabit Ethernet Applications

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

WHITE PAPER. 50 versus 62.5 micron multimode fiber

SFP Transceiver Specifications

Untangled: Improve Efficiency with Modern Cable Choices. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek

Latest Trends in Data Center Optics

Fibre Channel Fiber-to-Fiber Media Converters

Evolution of Ethernet Speeds: What s New and What s Next

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Simulation and Best Design of an Optical Single Channel in Optical Communication Network

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

Volume and Velocity are Driving Advances in Data Center Network Technology

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

TIA Releases Guidelines for Maintaining Polarity Using Array Connectors

10 Gigabit Ethernet Cabling

MPO. Fast Fibre Solution for Data Centres

Wavelength Division Multiplexing

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

What to do about Fiber Skew?

Plug & Play Universal Systems

Pretium EDGE HD Solutions

Preparing Infrastructure for 10 Gigabit Ethernet Applications

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

The Ethernet Roadmap Applications, servers, optics, and switches

Transcription:

40/100 Gb/s Ethernet Over Multi-mode Optical Fiber Planning for Infrastructure Readiness Alfred Flores Vice Chair, Fiber Optics LAN Section

Fiber Optics LAN Section Part of the Telecommunications Industry Association (www.tiaonline.org) Formed 16 years ago Mission: to educate users about the benefits of deploying fiber in customer-owned networks FOLS provides vendor-neutral information 2

Fiber Optics LAN Section Current Members Berk-Tek, a Nexans Company, Corning Optical Fiber CommScope Draka Communications Fluke Networks OFS Ortronics Sumitomo Electric Lightwave Tyco Electronics 3

40/100 Gb/s over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations Adoption Considerations Summary

40/100 Gb/s over MMF Evolution of Ethernet 40/100 Gb/s Ethernet Adoption Timeline Server port growth IEEE 802.3ba Objectives OM3 Link and Cable Characteristics Achieving 40/100 Gb Ethernet Issues Cabling Recommendations Adoption Considerations Summary 5

Ethernet Timeline IEEE 802.3a 10BASE-T IEEE 802.3 Ethernet IEEE 802.3u 100BASE-T IEEE 802.3ae 10GBASE- SR,LR,ER,SW,LW,EW,LX4 2002 1985 1990 1995 2000 IEEE 802.3a 10BASE2 IEEE 802.3j 10BASE-F Time to Reach (years) IEEE 802.3z 1000BASE- CX,SX,LX Million Port Sale (after Ratification) 60% Market Penetration 10 Mb E 1 100 Mb E 1 5 1000 Mb E 2 9 10 Gb E 6 10+ Flatman, LAN Technologies, 2007

40/100 Gb Ethernet Source: Intel/Broadcom (Nov 2007) 7

IEEE 802.3ba Objectives Provide Physical Layer specifications which support 40 Gb/s operation over: At least 100m on OM3 MMF At least 10m over a copper cable assembly At least 1m over a backplane Support a MAC date rate of 100 Gb/s Provide Physical Layer specifications which support 100 Gb/s operation over: At least 40km on SMF At least 10km on SMF At least 100m on OM3 MMF At least 10m over a copper cable assembly 8

... at least 100m on OM3 MMF OM3* multi-mode fiber is: 50/125 µm 2000 MHz km EMB**, minimum, at 850 nm ANSI/TIA-598-C Optical Fiber Cable Color Code Indoor cable with AQUA jacket * Type A1a.2 as specified in IEC 60793-2-10 ** Effective Modal Bandwidth 9

Link and Cable Characteristics* Supported fiber types 50/125 µm, OM3 Effective Modal Bandwidth (EMB) 2000 MHz km** minimum Power Budget Greater than 8.3 db*** Channel Insertion Loss 1.9 db *As of December 2008 **Launch Condition Dependent ***For Further Study Connector Loss Under Study 10

Evolution of Ethernet Achieving 40/100 Gb/s Ethernet Enabling Technology Parallel Optics, 40 Gb/s Parallel Optics, 100 Gb/s Polarity Recap Issues Cabling Recommendations Adoption Considerations Summary 40/100 GbE over MMF 11

Enabling Technology Multilane Distribution (MLD) Parallel Links 40 Gb/s equals 4x fibers each for Tx and Rx Each carrying a 10 Gb/s signal 100 Gb/s equals 10x fibers each for Tx and Rx Each carrying a 10 Gb/s signal Today, two fibers can support full duplex 10 Gb/s 40 Gb/s will require 4x the fiber count 12

Lanes 1 2 3 4 Parallel Optics, 40 Gb/s Lanes 4 3 2 1 40GBASE-SR4 MTP */MPO (Multi-fiber Push On) Connectors 8 or 12 Fiber Loose Tube or Ribbon cable Likely a pre-terminated assembly solution *MTP is a registered trademark of USCONEC 13

For 40GBASE-SR4 This is what the connector on your switch/router will likely look like Pins (male) will be on this receptacle MPO MPO preterm assemblies will be pinless (female) Proposed MDI Interface Paul Kolesar (Commscope), Sharon Lutz (USCONEC), Clause 86 MDI Optical Pin Layout and Connector, IEEE P802.3ba, Jan2009 14

Array Assemblies Polarity Today Position 1 (Fiber 1) Key Up Type-A MPO-to-MPO array cable Key Down Position 1 (Fiber 1) Position 12 (Fiber 12) Position 12 (Fiber 12) Type-B MPO-to-MPO array cable Position 1 (Fiber 1) Key Up Key Up Position 12 (Fiber 1) Position 12 (Fiber 12) Position 1 (Fiber 12) Position 1 (Fiber 1) Type-C MPO-to-MPO array cable Key Up Key Down Position 1 (Fiber 2) Position 12 (Fiber 12) Position 12 (Fiber 11) TIA-568-C.3 Key Up 15 Key Down

Parallel Optics, 100 Gb/s 100 Gb/s will use 10 fibers per Tx to Rx link Two 12F MTP/MPO connectors, or 24-Fiber MTP/MPO connections can significantly reduce pre-terminated connection costs and increase connection densities Lane assignments accepted at IEEE P802.3ba Draft 1.1 16

Proposed MDI Interface For 100GBASE-SR10 Proposed options on switch/router connector Pins (male) will be on these receptacles MPO MPO preterm assemblies will be pinless (female) Paul Kolesar (Commscope), Sharon Lutz (USCONEC), Clause 86 MDI Optical Pin Layout and Connector, IEEE P802.3ba, Jan2009 17

Recap 40/100 Gb/s will use Multiple fibers per Tx/Rx link Minimum of OM3 specified, 2000 MHz km @ 850 nm MTP/MPO connectors Loose tube or ribbon cabling compatible with MTP/MPO Preterm likely the norm Polarity puzzle 18

Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Arrival Time Optical Skew Skew Measurement Skew Results Cabling Recommendations Adoption Considerations Summary 40/100 GbE over MMF 19

Arrival Time Multi-lane signals launch simultaneously Fiber length and modal paths vary Signal components arrive out of sync This difference in arrival time is optical skew 20

Is Optical Skew a Problem? Transmission media (optical fiber) major contributor to skew Proposed allowance* for skew due to transmission media 79 ns Expected maximum contribution from optical media 13.6 ns Is a particular cable construction better in minimizing transmission optical skew? * 100GE/40GE skew budget, IEEE 802.3ba TF, Dallas November 2008, Gustlin/Anslow/Giannakopoulos 21

Optical Skew Measurement Method A Transmit a pulse down the fiber Measure arrival time Repeat for all fibers Calculate maximum difference Method B Transmit a pulse down the fiber Measure arrival time of reflections Repeat for all fibers Calculate maximum difference 22

Optical Skew Measurement Method C Launch RF modulated optical signal down each fiber using single mode optics Measure the phase difference of received RF signal with the reference, using a precise phase meter: propagation delay Calculate maximum delay difference 23

Skew Measurement Results Quadrature Phase Shift Testing 100 meter test length Loose Tube tested maximum 0.8 ns Ribbon tested maximum 0.3 ns Proposed Skew Allowance for 40GBASE-SR4 and 100GBASE-SR10 100 meter length 79 ns (about 100 times measured maximums) For Optical Skew neither loose tube cabling or ribbon cabling is a problem. 24

40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations Size and Bend Fiber Count Adoption Considerations Summary 25

Size and Bend Reduced O.D. 48F Loose Tube Cable (0.231 ) 48F Loose Tube Cable (0.370 ) 48F Stacked Ribbon Cable (0.520 ) Optical Skew Loose Tube and Ribbon cabling Optical skew adequately handled by electronics Preferential Bending Limits Flexibility Loose Tube Cabling No preferential bend Ribbon Cabling Has preferential bend 26

Fiber Count Requirements (1) Today, a 12F, OM3, MPO-MPO backbone link Provides up to six full duplex 10Gb/s Tx/Rx pairs 40GBASE-SR4 Requires a minimum of eight OM3 fibers for a Tx/Rx link 4 fibers Tx 4 fibers Rx Should be able use installed legacy 10GBASE-SR links 100m length 100GBASE-SR10 Requires a minimum of 20 OM3 fibers for a Tx/Rx link 10 fibers Tx 10 fibers Rx 27

Fiber Count Requirements (2) Legacy 10 GbE systems may not be directly mappable to 40/100 Gb/s A legacy 144F MPO-MPO backbone Will support 72x 10GBASE-SR duplex links Will support 12x 40GBASE-SR4 duplex links May support 6x 100GBASE-SR10 duplex links Bottom Line Installing 10Gb Ethernet installations today will fully utilize available fibers Future adoption of 40/100 Gb Ethernet will be able to use legacy cabling Fiber utilization using legacy cabling will likely not be at 100% 28

Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations Adoption Considerations Link Cost ratio on OM3 About single mode OM3 and OS2 About OM4 Summary 40/100 GbE over MMF 29

Link Cost Ratios on OM3 Traditional rule of thumb, 3x cost increase for 10x performance increase Not likely to hold for 40/100 Gb/s Estimates very preliminary, around 4x for 40GBASE-SR4 30

About Single Mode Not Parallel Optics Initial release using CWDM 40GBASE-LR4 uses 4x 10 Gb/s wavelengths 100GBASE-LR4 will likely use 4x 25 Gb/s wavelengths Estimate of 6x* cost of 10GBASE-LR Expected cost reductions with technology/ optimization improvements * 40GbE Market: Timing and Opportunity, Alessandro Barbieri, September 2008 IEEE Seoul 31

OM3 and OS2 Selecting a singlemode 40 GbE over an OM3 40 Gbe solution is expected to cost over 75% more than the multimode solution 32

About OM4* Current 10GBASE-SR uses VCSELs RMS Spectral width about 0.25 nm That is a tight light source When you combine low modal dispersion of OM4/ OM3 fiber with low chromatic dispersion of this laser you go farther Initial 40/100 Gb/s specification calls for RMS Spectral width of 0.65 nm Why? Reduce costs of transmitters and receivers Early adopters of 40/100 Gb/s will be data centers/sans * Not yet a standard 33

40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations Adoption Considerations Summary 40/100 Gb/s Redux 34

40/100 Gb/s Redux OM3 multi-mode fiber specified 2000 MHz km EMB at 850 nm At least 100 meter runs supported Parallel optics used MTP/MPO Optical skew exists but is compensated for by active components Observed skew 100 times less than specified Optical cabling recommendations Loose tube, no bending preference Relative Cost 35

Alfred Flores Berk-Tek, a Nexans Company alfred.flores@nexans.com 36