QA LINAC Daily, Monthly, Annual

Similar documents
MOC Exam Preparation Therapy

MLC Characteristics. Treatment Delivery Systems 2 Field Shaping; Design Characteristics and Dosimetry Issues. Presentation Outline

Quality Assurance of Radiotherapy Equipment

Chapter 12 QUALITY ASSURANCE OF EXTERNAL BEAM RADIOTHERAPY

Post Treatment Log File Based QA Varian. Krishni Wijesooriya, PhD University of Virginia. D e p a r t m e n t of R a d i a t i o n O n c o l o g y

Quality Assurance of accelerators; the technologists responsibility

NIA RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

1. Provide clinical training in radiation oncology physics within a structured clinical environment.

Performance evaluation and quality assurance of Varian enhanced dynamic wedges

Quality Assurance in Stereotactic. Radiotherapy

RapidArc QA Program in Prince of Wales Hospital. Michael L. M. Cheung, Physicist Prince of Wales Hospital Hong Kong

First Three Years After Project Proton Therapy Facility:

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

Accreditation Is Coming

ELECTRONIC MEDICAL RECORDS (EMR) STREAMLINE CH I PROCESS. Ping Xia, Ph.D. Head of Medical Physics Department of Radiation Oncology Cleveland Clinic

Challenges in small field MV photon dosimetry

CHAPTER 10. ACCEPTANCE TESTS AND COMMISSIONING MEASUREMENTS

QA of intensity-modulated beams using dynamic MLC log files

Radiation Oncology Centers Participating in MassHealth. Daniel Tsai, Assistant Secretary and Director of MassHealth

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Our Department: structure and organization

Specifications Varian Treatment Streamlined Treatment Delivery Management Application. Specifications

Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.

Stereotactic Radiosurgery & Stereotactic Body Radiation Therapy - Billing Basics. Presented: June 19, 2013 AAMD Annual Meeting San Antonio, TX

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

A Thesis. entitled. Retrofitted Micro-MLC SRS System. George H. Hancock

THE DOSIMETRIC EFFECTS OF

Digital vs. Analogue Control Systems

Gamma Knife and Axesse Radiosurgery

Clinical Rotation 4: PHYS 707 Spring 2016 (Feb. 25, 2016 to Aug. 25, 2016) COURSE INFORMATION

Clinical Photon Beams

Medical Device Correction

Evaluation of complexity and deliverability of IMRT- treatment plans. Author: Elin Svensson Supervisors: Anna Bäck and Anna Karlsson Hauer

Worldwide Quality Assurance networks for radiotherapy dosimetry

Key words: treatment planning, quality assurance, 3D treatment planning

HDR Brachytherapy 1: Overview of QA. Disclosures: Learning Objectives 7/23/2014

7/21/2014. Quality Metrics and Risk Management with High Risk Radiation Oncology Procedures. Disclosure of Conflict of Interest

CBCT for Prone Breast. Todd Jenkins, MS, DABR Nash Cancer Treatment Center

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

MVP/Care Core National 2015 Radiation Therapy Prior Authorization List (Effective January 1, 2015)

Horizon Blue Cross Blue Shield of New Jersey 2012 Radiation Therapy Payment Rules

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

RADIATION THERAPY. Dosimetry Pioneers since 1922 NEW

Albany Medical Center Chief Medical Physicist Radiation Oncology Imaging and Related Services

Complex 2015 Changes to Radiation Oncology Coding

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

TASK INVENTORY ARRT BOARD APPROVED: JULY 2015 IMPLEMENTATION DATE: JANUARY 2017

Scripps Proton Therapy Center: Configuration and Implementation

NEW YORK STATE DEPARTMENT OF HEALTH BUREAU OF ENVIRONMENTAL RADIATION PROTECTION EXTERNAL BEAM & BRACHYTHERAPY QUALITY ASSURANCE PROGRAM AUDIT FORM

The feasibility of a QA program for ISIORT Trials

IAEA-TECDOC Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems

Radiation Therapy Coverage, Coding, and Reimbursement for New Technologies

Radiosurgery 8/16/2011. Intracranial Stereotactic Radiosurgery (SRS) and Stereotactic Radiotherapy (SRT) Kamil M. Yenice, PhD University of Chicago

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Total Solutions. Best NOMOS One Best Drive, Pittsburgh, PA USA phone NOMOS

Robot Perception Continued

LINAC-based stereotactic radiosurgery for treatment of trigeminal neuralgia

External dosimetry Dosimetry in new radiotherapeutic techniques

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

RADIATION SHIELDING DESIGN 2010

Chapter 11 Computerized Treatment Planning Systems for External Photon Beam Radiotherapy

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

Failure Modes and Effects Analysis (FMEA)

BARC DEVELOPS COBALT-60 TELETHERAPY MACHINE FOR CANCER TREATMENT

Acknowledgement. Prerequisites: Basic Concepts of IMRT. Overview. Therapy Continuing Education Course Clinical Implementation of IMRT for Lung Cancers

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Analysis of Trajectory Log Files of TrueBeam Medical Electron Linear Accelerator for Patient Specific IMRT QA

Accreditation a tool to help reduce medical errors. Professor Arthur T Porter PC MD FACR FRCPC FACRO

Analysis (FMEA) for Radiation

Radiation Protection in Radiotherapy

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

The Canadian National System for Incident Reporting in Radiation Treatment (NSIR-RT) Taxonomy March 2, 2015 V2

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Automated Analysis of Varian Log Files for Advanced Radiotherapy Treatment Verification: A Multicenter Study

Protons vs. CyberKnife. Protons vs. CyberKnife. Page 1 UC SF. What are. Alexander R. Gottschalk, M.D., Ph.D.

Chapter 7: Clinical Treatment Planning in External Photon Beam Radiotherapy

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179

Radiation Therapy for Prostate Cancer: Treatment options and future directions

World-first Proton Pencil Beam Scanning System with FDA Clearance

Path Finder. CMA Engineering Designing & Consulting Inc. Miami, Florida

INTRODUCTION. A. Purpose

DICOM: Definitions and Testing

SEAAPM Symposium The Practice of Quality Assurance in an Era of Change

Independent corroboration of monitor unit calculations performed by a 3D computerized planning system

Virtual Reality Training for Radiotherapy becomes a Reality

INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR PROSTATE CANCER PATIENTS

In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

Department of Radiation Oncology H. Lee Moffitt Cancer Center Khosrow Javedan M.S, Craig Stevens MD, Ph.D., Ken Forster Ph.D.

QA & DOSIMETRY NEWS. Respiratory MotionSim TM. Introducing. Quality Reports [EMR] Plan Quality Management»

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Project Management Triangle

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

HITACHI Proton Beam Therapy System

MEDICAL DOSIMETRY. COLLEGE OF APPLIED SCIENCES AND ARTS Graduate Faculty: therapy.

Prostate IMRT: Promises and Problems Chandra Burman, Ph.D. Memorial Sloan-Kettering Cancer Center, New York, NY 10021

REPORT ORGANIZATION ABSTRACT I. INTRODUCTION CALCULATION OF EFFECTIVE DOSE PER IMAGE ACQUISITION CALCULATION OF EFFECTIVE DOSE PER TREATMENT COURSE

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

Transcription:

QA LINAC Daily, Monthly, Annual Jack Yang, Ph.D., DABR Institute for Advanced Radiation Oncology Barnabas Health Long Branch, NJ 07740 New Technologies in Modern Radiotherapy, Chulabhorn Research Institute, Bangkok, Thailand, August 22-25, 2012

Outlines Definition of treatment delivery quality assurance for LINAC Assure that the 5% final dose discrepancy can be achieved with the site specific QA process Current QA protocols implemented in modern radiation oncology clinics with updated LINAC functionalities

Radiation Oncology Error Management Clinical experience has shown that variations of 10% or more in the delivered dose can sharply reduce the probability of local tumor control. ICRU Report 62 recommends that radiotherapy be delivered within 5% of the prescribed dose to ensure adequate tumor control. The global aim is to achieve the desired tumor control while maintaining toxicities to normal tissues to a minimum Are these endpoints achievable with current delivery technology? Fig., Connor et al, IJROBP 1975

Linac QA Components: Dosimetric accuracy Mechanical Accuracy Safety Frequency: Daily Monthly Annually

The Early QA report (1994) AAPM TG-40 report Comprehensive QA program QA of EXRT (External Beam Treatment) equipment QA of RTP (Information and IT tools) system Brachytherapy Clinical practice

Periodic QA of Linear Accelerator (TG-40) Frequency Procedure Tolerence (±) Daily X-ray & electron output constancy 3% Localization lasers 2 mm Safety interlocks (door) functional Monthly X-ray & Electron output constancy 2% Light/radiation field coincidence 2 mm X-ray flatness and symmetry 2% Electron flatness and symmetry 2% X-ray energy 2% in depth dose (2% in ionization ratio) Electron energy 2 mm in R 80 (2 mm in R p ) Optical distance indicator 2 mm Field size indicators 2 mm Gantry angle indicator 1 Collimator angle indicator 1 Cross-hair centering 1 mm Annually Full calibration 2% Isocenter shift 2 mm Collimator rotation 2 mm diameter Gantry rotation 2 mm diameter Couch rotation 2 mm diameter Couch vertical travel 2 mm Tabletop sag 2 mm

Radiation Isocenter Checks Collimator» 2 mm diameter circle Treatment table» 2 mm diameter circle Gantry» 2 mm diameter circle

Misadministration Definition in US For external beam (>3 fractions) No written directive Wrong patient Wrong site Weekly dose exceeds 30% Total dose exceed 20% Most of the LINACs are inspected and governed by the state government!!

Misadministration Definition in US For Stereotactic radiosurgery/radiotherapy (<= 3 fractions) No written directive Wrong patient Wrong site Total dose error exceeds 10%

Background of TG 142 Principles - TG-40 was the International Commission on Radiation Units and Measurements (ICRU) recommendation that the dose delivered to the patient be within ±5% of the prescribed dose. The goal of a QA program for linear accelerators is to assure that the machine characteristics do not deviate significantly from their baseline values acquired at the time of acceptance and commissioning.

Rationales for Developing TG 142 New Technology since TG 40 MLC, as Asymmetric Jaws, Dynamic & virtual wedges, EPIDs. Imaging: kv and cone beam, Respiratory gating.. Clinical procedures not emphasized in TG 40 with new modalities such SRS, SBRT, TBI, IMRT TG50, TG58, TG76 TG106, TG104, TG100 for various LINAC QAs

TG 142 fro Linear Accelerator QAs What This Report Doesn t cover (some special techniques) Describe the techniques for performing QA tests Accelerator beam data commissioning equipment and procedures TG-106 QA for TomoTherapy TG-148 QA for Robotic Radiosurgery TG-135 QA for Non-Radiographic Radiotherapy Localization & Positioning Systems TG-147 Does add Specific Recommendations / Supplements the Work of Basic Applications of Multileaf Collimators TG-50 Clinical use of electronic portal imaging - TG-58 Management of Respiratory Motion TG-76 Kilovoltage localization in therapy TG-104

MLC QA TG 50 (2001) - Update

EPID QA TG 58 (2001) - Update

TG-142 Testing Standards Acceptance Testing Procedure (ATP) Standards Acceptance testing sets the baseline for future dosimetric measurements for beam performance constancy, verifies that the equipment is mechanically functional and operates within certain tolerances from absolute specified values. Tolerances and Action Levels Level 1 Inspection Action Level 2 Scheduled Action Level 3 Immediate Action or Stop Treatment Action or Corrective Action With these 3 action levels, there is an institutional need to specify the thresholds associated with Levels 2 and 3. Level 1 threshold isn t a critical requirement but can lead to improvements in the QA program.

TG-142 Daily Procedure Tolerance (non- IMRT machines) Tolerance (IMRT machines) Tolerance (Stereotactic machines) Dosimetry X-ray output constancy (all energies) Electron output constancy (Weekly, except for machines with unique e- monitoring requiring daily) 3% Mechanical Laser localization 2 mm 1.5 mm 1 mm Distance indicator (ODI)@ iso 2 mm 2 mm 2 mm Collimator size indicator 2 mm 2 mm 1 mm Safety Door interlock (beam off) Door closing safety Audiovisual monitor(s) Stereotactic interlocks (lockout) NA NA Radiation area monitor (if used) Beam on indicator

TG-142 Daily (Continued) Procedure Tolerance (non- IMRT machines) Tolerance (IMRT machines) Tolerance (Stereotactic machines) Dosimetry X-ray output constancy (all energies) Electron output constancy (Weekly, except for machines with unique e- monitoring requiring daily) 3% Mechanical Laser localization 2 mm 1.5 mm 1 mm Distance indicator (ODI)@ iso 2 mm 2 mm 2 mm Collimator size indicator 2 mm 2 mm 1 mm Safety Door interlock (beam off) Door closing safety Audiovisual monitor(s) Stereotactic interlocks (lockout) NA NA Radiation area monitor (if used) Beam on indicator

TG-142: Monthly Procedure Tolerance (non- IMRT machines) Tolerance (IMRT machines) Tolerance Stereotactic machines Dosimetry X-ray output constancy Electron output constancy 2% Backup monitor chamber constancy Typical dose rate 2 output constancy NA 2% (@ IMRT dose rate) 2% (@ stereo dose rate, MU) Photon beam profile constancy Electron beam profile constancy 1% Electron beam energy constancy 2%/2mm

TG-142 - Monthly (Continued) Procedure Tolerance (non-imrt machines) Tolerance (IMRT machines) Tolerance Stereotactic machines Mechanical Light/radiation field coincidence* 2 mm or 1% on a side Light/radiation field coincidence* (Asymmetric) 1 mm or 1% on a side Distance check device used for lasers/odi (vs. front pointer) 1mm Gantry/collimator angle indicators (@ cardinal angles) (Digital only) 1.0 deg Accessory trays (i.e. Port film graticle tray) 2 mm Jaw position indicators (Symmetric)3 2 mm Jaw position indicators (Asymmetric)1 1 mm Cross-hair centering (walk-out) 1 mm Treatment couch position indicators4 2 mm/1 deg 2 mm/ 1 deg 1 mm/ 0.5 deg Wedge placement accuracy 2mm Latching of wedges, blocking tray5 5 Localizing lasers ±2 mm ±1 mm <±1 mm Respiratory gating Beam output constancy 2% Phase, Amplitude beam control In room respiratory monitoring system Gating interlock

TG-142 - Monthly (Continued) Procedure Tolerance (non-imrt machines) Tolerance (IMRT machines) Tolerance Stereotactic machines

TG-142: Annual Dosimetry Procedure Tolerance (non- IMRT machines) Tolerance (IMRT machines) X-ray flatness change from baseline 1% X-ray symmetry change from baseline ±1% Electron flatness change from baseline 1% Electron symmetry change from baseline ±1% SRS Arc rotation mode (range: 0.5 to 10 MU/deg ) X-ray/electron output calibration (TG-51) Spot check of field size dependent output factors for X-ray (2 or more FS) Output factors for electron applicators (spot check of 1 applicator/energy) X-ray beam quality (PDD 10, TMR 10 20 ) Electron beam quality (R 50 ) Transmission factor constancy for all treatment accessories Physical wedge transmission factor constancy NA NA ±1%(absolute) 2% for field size < 4x4 cm 2, 1% 4x4 cm 2 ±2% from baseline ±1% from baseline ±1mm ±1% from baseline ±2% Tolerance Stereotactic machines Monitor units set vs. delivered:1.0 MU or 2% (whichever is greater) Gantry arc set vs. delivered: 1.0 deg or 2% (whichever is greater)

TG-142 Annual (Continued) Procedure X-ray monitor unit linearity [output. constancy ] Electron monitor unit linearity [output. constancy ] X-ray output constancy vs dose rate X-ray output constancy vs gantry angle Electron output constancy vs gantry angle Electron and X-ray Off-axis factor constancy vs gantry angle Arc mode (expected MU, degrees) TBI/TSET Mode PDD or TMR and OAF constancy TBI/TSET Output calibration TBI/TSET accessories Tolerance (non-imrt machines) ±2% 5MU Tolerance (IMRT machines) ±5% (2-4 MU), ±2% 5MU ±2% 5MU ±2% from baseline ±1% from baseline ±1% from baseline ±1% from baseline ±1% from baseline Tolerance Stereotactic machines ±5% (2-4), ±2% 5MU 1% (TBI) or 1mm PDD shift (TSET) from baseline 2% from baseline 2% from baseline

TG-142 Annual (Continued) Procedure Tolerance (non- IMRT machines) Tolerance (IMRT machines) Tolerance Stereotactic machines Mechanical Collimator rotation isocenter Gantry rotation isocenter Couch rotation isocenter Electron applicator interlocks Coincidence of radiation and mechanical isocenter Table top sag ±2mm from baseline ±1 mm from baseline ±1 mm from baseline ±1 mm from baseline ±2mm from baseline 2mm from baseline ±1mm from baseline Table Angle 1 degree Table travel maximum range movement in all directions ±2mm Stereotactic accessories, lockouts, etc NA Safety Follow manufacturers test procedures Respiratory gating Beam energy constancy 2% Temporal accuracy of Phase/Amplitude Gate-on 100 ms of expected Calibration of surrogate for respiratory phase/amplitude 100 ms of expected Interlock testing

Wedge Verification (Not Physical) Dynamic-incl. EDW (Varian), Virtual (Siemens), Universal (Elekta) Wedge quality assurance Frequency Daily Monthly Annual Procedure Morning Check-out run for 1 angle Wedge factor for all energies Check of wedge angle for 60, full field & spot check for intermediate angle, field size * Recommendation to check 45º if angles other than 60º are used. Tolerance Dynamic Universal Virtual C.A. Axis 45º or 60 WF (within 2%)* C.A. Axis 45º or 60 WF (within 2%)* 5% from unity, otherwise 2% Check of Off-center ratios @ 80% field width @ 10cm to be within 2%

MLC Verification Multi-leaf collimation quality assurance (with differentiation of IMRT vs. non-imrt machines) Frequency Procedure Tolerance Weekly (IMRT machines) Qualitative test (i.e. matched segments, aka, picket fence ) Visual inspection for discernable deviations such as an increase in interleaf trransmission Monthly Setting vs. radiation field for two patterns (non-imrt) Backup diaphragm settings (Elekta only) Travel speed (IMRT) Leaf position accuracy (IMRT) 2mm 2mm Loss of leaf speed > 0.5 cm/sec 1mm for leaf positions of an IMRT field for 4 cardinal gantry angles. (Picket fence test may be used, test depends on clinical planning segment size)

MLC - Annual Test MLC Transmission (Average of leaf and interleaf transmission), All Energies ±0.5% from baseline Leaf position repeatability ±1.0 mm MLC spoke shot Coincidence of Light Field and X-ray Field (All energies) Arc dynamic leaf-speed test Arc dynamic interlock trip test Arc dynamic typical plan test Segmental IMRT (Step and Shoot) Test Moving window imrt (4 cardinal gantry angles) 1.0 mm radius ±2.0 mm <0.35 cm Max Error RMS, 95% of error counts <0.35 cm (Varian) Leaf position interlock occurs (Varian) <0.35 cm Max Error RMS, 95% of error counts <0.35 cm (Varian) <0.35 cm Max Error RMS, 95% of error counts <0.35 cm (Varian) <0.35 cm Max Error RMS, 95% of error counts <0.35 cm (Varian)

Imaging Equipment Test - Daily Procedure Non-SRS/SBRT Applications Tolerances SRS/SBRT Applications Tolerances MV imaging (EPID) Daily Collision interlocks Spatial linearity1 (x and y) (single gantry angle) Imaging & Treatment coordinate coincidence (single gantry angle) < 2 mm 1 mm < 2 mm 1 mm Positioning/repositioning < 2 mm 1 mm KV imaging 2 Collision interlocks Imaging & treatment coordinate coincidence < 2 mm 1 mm Positioning/repositioning < 2 mm 1 mm Cone-beam CT (kv & MV) Collision interlocks Positioning/repositioning < 2 mm 1 mm

Imaging Equipment Test - Monthly Procedure Non-SRS/SBRT Applications Tolerances SRS/SBRT Applications Tolerances MV imaging (EPID) Imaging & treatment coordinate coincidence (4 Cardinal angles) < 2 mm 1 mm Scaling3 < 2 mm < 2 mm Spatial resolution Baseline 4 Baseline Contrast Baseline Baseline Uniformity and noise Baseline Baseline kv imaging Imaging & treatment coordinate coincidence (4 Cardinal angles) < 2 mm 1 mm Scaling < 2 mm 1 mm Spatial linearity (x and y) (single gantry angle) < 2 mm 1 mm Spatial resolution Baseline Baseline Contrast Baseline Baseline Uniformity and noise Baseline Baseline Cone-beam CT (kv & MV) Imaging & treatment coordinate coincidence < 1.5 mm 1 mm Geometric distortion < 2 mm 1 mm Spatial resolution Baseline Baseline Contrast Baseline Baseline HU constancy Baseline Baseline Uniformity and noise Baseline Baseline Spatial linearity (x and y) (single gantry angle) < 1 mm 1 mm

Imaging Equipment Test - Annual MV imaging (EPID) Procedure Non-SRS/SBRT Applications Tolerances SRS/SBRT Applications Tolerances Full range of travel SDD ±5 mm ±5 mm Imaging dose5 Baseline Baseline Beam quality / energy Baseline Baseline kv imaging Beam quality / energy Baseline Baseline Imaging dose Baseline Baseline Cone-beam CT (kv & MV) Imaging dose Baseline Baseline

Conclusions LINAC QA protocols have become extensive through modern LINAC development and implementation. AAPM TG-40 report still function as the base lines. AAPM TG-142 has gradually emerging into modern clinical practice (some of those testing are tedious and maybe not applicable to a busy clinic). However, regulatory agencies still have hard time to follow due to manpower, training and budgeting constraints. Annual report should include but not limited to the following:. (1) Dosimetry, (2) Mechanical, (3) Safety, (4) Imaging, and (5) Special Devices/Procedures.