Loadstar 250A MCB Distribution Boards

Similar documents
Distribution Boards & Consumer Units

The complete range of consumer switchboards and switchgear

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SELECTION OF FINAL CIRCUIT PROTECTION

Product and functional description

R.C.C.B. s two-pole LEXIC

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Smart solutions for electrical distribution in commercial and industrial applications

GE Power Controls. MiniFORM Switchboards

Distribution Boards. A perfect blend of aesthetics, functionality and safety

Linear Luminaire with LED Series EXLUX 6402/2

How can a charging station for electric vehicles be set up simply and safely?

2008 powertrack and floorboxes

Transformers from 25va to 500kva. Standard despatch in days not weeks

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

MK Electric Sentry Circuit Protection Solutions

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Problem / Solution. The problem:

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Operating Instructions

Quick Connect. quick - simple - efficient.

Unified requirements for systems with voltages above 1 kv up to 15 kv

QUICK REFERENCE PRICE GUIDE JULY 2015

Circuit Breakers. Next Generation of Protection Capabilities

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Smart solutions for electrical distribution in commercial and industrial applications

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

ADM1TE 5/30A DIN rail single phase two wire energy meter

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Securing your electrical installations Prisma,

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

ASSEMBLED SOCKET-COMBINATIONS

ZS25 Screw Clamp Terminal Blocks Feed-through

Modis 25/32. Modular Switchboard Solution

The power distribution board that sets new standards

Tape Wound, Split Core and Ebony Current Transformers

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

E-STOP relays, safety gate monitors

MasterINTERFACE 39 Series - Relay interface modules

Digital input modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

TriLine ASSEMBLY System PowerModules

Manual motor starter MS116

Tape Wound, Split Core and Ebony Current Transformers

49 Series - Relay interface modules A. Features

HERZ-Thermal Actuators

Slimline Plus. Catalogue No. R6

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Mureva Assembly surface mounted wiring devices

A project to optimise quality and energy efficiency must include metering

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Protection catalogue 15

Phone: Fax: Web: info@clrwtr.com

FAQs-Main switchboard design criteria

Switchboard system. NorLine 800

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Vario-Series Accessories

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

How To Build A Low Voltage Capacitor Lvcp

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Secondary Unit Substations

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

5SV Residual Current Protective Devices

Electro-pneumatic control valves

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Tmax MCCBs. Molded case circuit breakers. Tmax

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Electronic overload relay EF19 and EF45

SVR 12/24V and SVR Akku 12V Installation instructions

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Manual Motor Starter MS 116 up to 16 A Technical Data

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Specifying a Variable Frequency Drive s

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

The complete guide to Low Voltage switchgear

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Aluminium Standard. Technical Data. Included in delivery

ZS10 Screw Clamp Terminal Block

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Acclaim III Recessed Fluorescent Luminaires ATEX

Transcription:

Loadstar 50A MCB Distribution Boards

50A DISTRIBUTION BOARDS TPN Boards rated 5A and 50A MCBs - 6A to 63A Type B, C and D Characteristics Single, Double and Triple Pole 8mm modular width 0kA BS EN 60898 RCBOs - 6A to 50A Types B & C Characteristic Single Pole 8mm wide 0kA BS EN 6009 System Paint Finish, Epoxy Powder, Light Grey RAL 7035 Custom Built Specials Service LOADSTAR MCBs, RCBOs AND DISTRIBUTION BOARDS 3

4 LOADSTAR DISTRIBUTION BOARDS & INCOMING OPTIONS 50A TYPE B DISTRIBUTION BOARDS AND THEIR INCOMING OPTIONS l Incoming options - order separately: Integral metering available Busbars rated at 50A IP3X (Door Closed) or IP66 Full compliment of Neutral & Earth terminals Incoming maximum 0mm Outgoing maximum 5mm Allows the fixture of dual Earth bars (IP3X) Clean Earth kit available (IP3X) All IP3X boards are supplied as standard with hinged outer door, catch (lock is optional extra) and removable top/bottom gland plates Neutral busbar supports incorporate an integral MCB end stop BS EN 6439-3 8LSMR LOADSTAR INCOMER OPTIONS l 50TPSD 00TPMB 50A TYPE B DISTRIBUTION BOARDS METER READY SURFACE l No of Ways H W D List No. 4 768 430 55 8LS04MR SWITCH DISCONNECTORS AND DIRECT CONNECTION l Switch Disconnector List No 50A* 3P 50TPSD 50mm Terminal capacity * Derated to 5A when used as an incomer to MCB distribution boards. Direct Connection 50A 3P 0mm Terminal capacity 50TPDC All Incomers are supplied complete with mounting kit, links & fixing screws MOULDED CASE CIRCUIT BREAKERS l 00A 3P 6 8 430 55 8LS06MR 8 876 430 55 8LS08MR 984 430 55 8LSMR 6 09 430 55 8LS6MR 0 00 430 55 8LS0MR 4 308 430 55 8LS4MR 85mm terminal capacity 00TPMB All Incomers are supplied complete with mounting kit, links & fixing screws IEC 60947-, EN 60947-

GENERAL LOADSTAR ACCESSORIES TP & SP l List No 8AS DINRAIL, ROWBOARD, SERVICE CENTRES l Rowboard: Suitable for Stand-Alone use or Add-On above surface L type board. Each row will accommodate 8 off 8mm module wide DIN Rail mounted devices. Main Neutral and Earth Bars included, along with provision for additional Mini Neutral and Earth bars. No of Rows H W D Surface 45 430 55 8AS 40 430 55 8AS 3 570 430 55 8AS3 4 735 430 55 8AS4 5 85 430 55 8AS5 Service Centre/ DIN Rail Board: Add-On for fixture above or below surface L Type board. Equipped with easily removed DIN Rail to accommodate 8 or 36, 8mm module wide DIN Rail mounted devices 45mm & 40mm high 8 Module 8DIN8 36 Module ( Rows of 8) 8DIN36 8DIN8 Cable Spreader Box Add on Enclosure, 45mm high, Blank front cover plate 8SB 8BB Blanking Strip MCBLD + 748 CSBC 8MBP 6CL 7CC (fitted to Earth Bar) CLEB CLNB Cylinder Lock & Key MCB Locking device (excl. lock) 6CL Padlock & Key for use with MCBLD 748 Clean Earth Bar Kit L & H Boards only. (4 to way= kit, 6 to 4 way= kits). Blanking Strip - 6 Individual module wide pieces Blanking Strip - Individual module wide pieces Blanking Strip - 4 lengths each 3 modules wide Blanking Strip - lengths each modules wide Clip In Blank SP Moulding Busbar cross connector insulator - pack of 9 SP MCB size Blank (shields MCB & Busbar Terminal) Cable clamp assembly (70mm ) - pack of 3 Previously manufactured DBs utilize 8CB blank pieces MCBLD 8CEBK 8BP/6 8BP/ 8PB3/4 8BP/ CSBC 8BB 8MBP 7CC ADDITIONAL EARTH BAR KITS l Additional Earth Bars to fit TP Distribution Boards No of Ways List No No of Ways List No 4 8EB04 6 8EB6 6 8EB06 0 8EB0 8 8EB08 4 8EB4 8EB Earth and Neutral bar, 0mm cable max, for use with DIN Rail NEUTRAL EARTH 7 Terminals CLNB07 CLEB07 Terminals CLNB CLEB 5 Terminals CLNB5 CLEB5 LOADSTAR ACCESSORIES 5

6 LOADSTAR MCBs & RCBOs 6HS MCBs SINGLE POLE MCBs l RATING AMPS 0kA B TYPE C TYPE D TYPE 6A 6HS06B 6HS06C 6HS06D 0A 6HS0B 6HS0C 6HS0D 6A 6HS6B 6HS6C 6HS6D 0A 6HS0B 6HS0C 6HS0D 5A 6HS5B 6HS5C 6HS5D 3A 6HS3B 6HS3C 6HS3D 40A 6HS40B 6HS40C 6HS40D 50A 6HS50B 6HS50C 6HS50D 63A 6HS63B 6HS63C 6HS63D 6HD3B 6HD3C DOUBLE POLE MCBs l RATING AMPS 0kA B TYPE C TYPE D TYPE 6A 6HD06B 6HD06C 6HD06D 0A 6HD0B 6HD0C 6HD0D 6A 6HD6B 6HD6C 6HD6D 0A 6HD0B 6HD0C 6HD0D 5A 6HD5B 6HD5C 6HD5D 3A 6HD3B 6HD3C 6HD3D 40A 6HD40B 6HD40C 6HD40D 50A 6HD50B 6HD50C 6HD50D 63A 6HD63B 6HD63C 6HD63D Not suitable for use within Distribution Boards BS EN 60898 6HT40B 6HS RCBOs 6HT3C TRIPLE POLE MCBs l RATING AMPS 0kA B TYPE C TYPE D TYPE 6A 6HT06B 6HT06C 6HT06D 0A 6HT0B 6HT0C 6HT0D 6A 6HT6B 6HT6C 6HT6D 0A 6HT0B 6HT0C 6HT0D 5A 6HT5B 6HT5C 6HT5D 3A 6HT3B 6HT3C 6HT3D 40A 6HT40B 6HT40C 6HT40D 50A 6HT50B 6HT50C 6HT50D 63A 6HT63B 6HT63C 6HT63D BS EN 60898 RCBOs SINGLE MODULE l RATING AMPS 0kA B TYPE C TYPE 6A 6HSR06/30B 6HSR06/30C 0A 6HSR0/30B 6HSR0/30C 6A 6HSR6/30B 6HSR6/30C 0A 6HSR0/30B 6HSR0/30C 3A 6HSR3/30B 6HSR3/30C 40A 6HSR40/30B 6HSR40/30C 50A 6HSR50/30B 6HSR50/30C 8mm wide, suitable for use within Loadstar Distribution Boards 30mA sensitivity, B or C characteristic, unswitched Neutral. RCBOs with longer incoming neutral flying leads (.m) are available - Suffix the Type C list number with /LT. (eg: 6HSR3/30C/LT). IEC/ EN 6009

LOADSTAR SUB METERING OPTIONS SUB METERING l Sub metering provides an awareness of energy use. Trends of minimum and maximum demand become visible enabling any instances of energy waste to be identified. Metering alone cannot reduce energy consumption or subsequent carbon emissions - action taken based upon knowledge gained from an effective metering strategy can. Schedule 7 of the Electricity Act 989 requires that all meters must be approved for use in a billing situation. MID (Measuring Instruments Directive) approved meters have, since 006, been approved for billing purposes across the EU. Non MID meters include MODBUS (RTU) connections and pulsed output as a standard feature. MID meters are supplied with a pulsed output as a standard feature. LS50MPKIT INTEGRAL METER KIT I Integral meter kits suitable for mounting within 50A type B Meter Ready (MR) Distribution Boards. Includes a Digital energy meter, three current transformers, fuses, neutral link, wiring looms and mounting base plate. Suitable for use with a 3ph 4 wire unbalanced system. Description 50A Integral Meter Kit LS50MPKIT Integral Meter Kit (MID) LS50MIDMPKIT LS5MPKIT 8MH50LP 50A DUAL METER PACK I 740mm high add on assembly suitable for mounting directly beneath two surface 50A type B Distribution Boards. Includes two digital energy meters, six current transformers, all associated fuses & wiring and flexible interconnections to Distribution Boards. Provides single point isolation while dual meters allow for separate monitoring of Light and small Power energy consumption. Suitable for use with a 3ph 4 wire unbalanced system. Description 50A Add-on Dual Meter Pack 8MH50LP For use with IP3X Type B Distribution Boards. LOADSTAR METERING OPTIONS 7

LOADSTAR MINIATURE CIRCUIT BREAKER - Tripping Characteristics and Earth Loop Impendance Values l Tripping Characterteristics TRIPPING TIME MINUTES SECONDS.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.5 3 I_3653 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT Maximum earth fault loop impedance (Zs) for circuit breakers with Uo of 30V, incorporating the 0.95 Cmin factor, 7th Edition IET Wiring Regulations (BS767:008), Amendment 3 effective from st January 05 Characteristic B t a 0.4s t a 5s I n (A) Ω Ω 6 7. 7. 0 4.37 4.37 6.76.76 0.9.9 3.33.33 40.05.05 50 0.86 0.86 63 0.67 0.67 Tripping characteristic B For universal use in socket outlet and lighting circuits. TECHNICAL DATA LOADSTAR 8 TRIPPING TIME MINUTES SECONDS TRIPPING TIME MINUTES SECONDS.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.5.5 3 3 I_365 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT I_3654 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT Characteristic C t a 0.4s t a 5s I n (A) Ω Ω 6 3.6 7. 0.9 4.37 6.33.66 0.05.09 3 0.67.33 40 0.57.4 50 0.48 0.95 63 0.38 0.76 Tripping characteristic C Particularly advantageous in lamp and motor circuits with higher starting currents. Characteristic D t a 0.4s t a 5s I n (A) Ω Ω 6.38 7. 0.05 4.37 6 0.67.66 0 0.48.09 3 0.9.33 40 0.7.4 50 0. 0.95 63 0.9 0.76 Tripping characteristic D For electrical circuits with strong pulse-generating equipment, such as transformers or solenoid valves.

LOADSTAR MINIATURE CIRCUIT BREAKER - Rating of Luminaire Circuits l Maximum permissible lamp load of a miniature circuit breaker when operating fluorescent lamps L 8 W, L 36 W, L 38 W, L 58 W Maximum number of fluorescent lamps Electronic ballast Full switching at 30 V Group switching at 30 V I n (A) Lamp -lamp ) -lamps ) -lamp ) -lamps ) Characteristic B C D B C D B C D B C D 6 L 8 W 7 37 66 7 35 35 66 66 66 35 35 35 L 36 W 7 37 37 7 9 9 37 37 37 9 9 9 L 58 W 7 9 9 9 9 9 0 L 8 W 36 67 36 58 58 58 58 58 L 36 W 36 6 6 3 3 3 6 6 6 3 3 3 L 58 W 3 3 3 0 0 0 3 3 3 0 0 0 6 L 8 W 56 00 77 56 94 94 77 77 77 94 94 94 L 36 W 56 00 00 5 5 5 00 00 00 5 5 5 L 58 W 5 5 5 3 3 3 5 5 5 3 3 3 0 L 8 W 70 7 70 7 7 7 7 7 L 36 W 70 7 5 64 64 64 5 5 5 64 64 64 L 58 W 64 64 64 40 40 40 64 64 64 40 40 40 3 L 8 W 00 44 355 00 44 88 355 355 355 88 88 88 L 36 W 00 44 00 00 03 03 00 00 00 03 03 03 L 58 W 00 03 03 65 65 65 03 03 03 65 65 65 40 L 8 W 6 6 444 6 6 35 444 444 444 35 35 35 L 36 W 6 6 50 6 9 9 50 50 50 9 9 9 L 58 W 6 9 9 8 8 8 9 9 9 8 8 8 50 L 8 W 80 47 555 80 47 94 555 555 555 94 94 94 L 36 W 80 47 3 6 6 6 3 3 3 6 6 6 L 58 W 6 6 6 0 0 0 6 6 6 0 0 0 63 L 8 W 70 340 567 70 340 370 700 700 700 370 370 370 L 36 W 70 340 393 70 03 03 393 393 393 03 03 03 L 58 W 70 03 03 8 8 8 03 03 03 8 8 8 ) All ECGs are turned on simultaneously. ) The ECGs are turned on in groups one after the other. Reduction factors for miniature circuit breakers for the simultaneously switcing on of incandescent lamp loads, taking into account the rated current of the miniature circuit breaker and the summated current of the lamps Reduction factor Switching with miniature circuit breaker Switching with separate switch Characteristic B 0.5 0.6 Characteristic C Characteristic D Current carrying capacity of miniature circuit breakers with corrected and uncorrected HQ, HQI and NAV lamps (number) Lamp power (W) 35 70 50 50 400 000 000 3500 Lamp current (A) 0.5.8 3 3.5 9.5 0.3 8 Corrected lamp current (A) 0.3 0.5.5 6 5.5 9.8 Inrush peak (A) 0 8 36 60 70 0 5 0 In(A) Lamp power (W) 35 70 50 50 400 000 000 3500 Characteristic B 6 0 0 0 0 0 0 0 5 3 0 0 0 0 6 8 5 0 0 0 0 6 3 0 3 6 8 4 0 40 0 5 3 3 50 8 5 7 4 4 63 6 4 7 4 3 Characteristic C 6 6 3 0 0 0 0 0 0 6 3 0 0 0 6 6 9 4 0 0 8 0 5 3 0 3 6 3 3 40 33 8 9 5 4 50 38 0 6 5 3 3 63 53 9 4 9 7 4 4 Characteristic D 6 8 4 0 0 0 0 4 7 4 0 0 0 6 6 3 3 0 0 8 4 7 4 4 0 3 44 7 6 40 56 8 5 9 8 3 50 70 35 9 0 4 3 63 88 44 4 4 4 4 Different data for corrected/uncorrected lamps. Circuit impedance: The specified lamp loads apply, taking into account a line impedance of 800 m. At 400 m the permissible values are reduced by 0%. TECHNICAL DATA LOADSTAR 9

LOADSTAR RANGE l DISTRIBUTION BOARDS l Standards Compliance: BSEN6439-3 and IEC 6439-3 Rated Voltage: 30/400V, 50/60Hz Busbar Rating: 50A Rated Insulation Voltage: 500V a.c. Short Circuit Withstand: 6kA Conditional Protection Degree: IP3X (Door Closed) ISOLATORS & SWITCH DISCONNECTORS l When used as an incomer to MCB Distribution Boards Standards Compliance: Rated Voltage: Rated Insulation Voltage: Rated Impulse Withstand Voltage: Rated Duty: 00A 5A Pole Configuration: Isolators 5A BSEN60947-3 and IEC/EN60947-3 30/400V, 50/60HZ 500V a.c. 6kV a.c. peak AC B (Double Pole) AC B (Triple Pole) Double Pole, Triple Pole M0 Lug (0mm wide) ISOLATORS & SWITCH DISCONNECTORS l When supplied loose Standards Compliance: Rated Voltage: Rated Insulation Voltage: Rated Impulse Withstand Voltage: Rated Duty: 00A 50A Pole Configuration: Isolators 50A: BSEN60947-3 and IEC/EN60947-3 30/400V, 50/60HZ 500V a.c. 6kV a.c. peak AC B (Double Pole) AC B (Triple Pole) Double Pole, Triple Pole Incoming M0 Lug (0mm wide) Outgoing M8 Lug (6mm wide) MINIATURE CIRCUIT BREAKERS (MCBs) l Standards Compliance: BSEN60898 and IEC 60898 Rated Voltage: 30/400V, 50/60Hz Short Circuit Capacity: 0kA BSEN60898- and IEC60898- Tripping Characteristics: Types B, C and D Temperature Range: Maximum Operating Temperature: 55 C Pole Configuration: Single Pole, Double Pole, Triple Pole Maximum Terminal Capacity: 35mm MOULDED CASE CIRCUIT BREAKERS (MCCBs) l Standards Compliance: Rated Current In: Rated Configuration: Rated Operational voltage: Rated Breaking Capacity: RCBOs l IEC/EN60947-00A 3 Pole or 4 Pole 690V 65kA Standards Compliance: EN6009, IEC 6009 Rated Voltage: 30V 50Hz Rated Short Circuit Capacity: 0kA MCB Tripping Characteristics: Types B and C RCD Class: Type A Neutral: Unswitched Maximum Terminal Capacity: 6mm Neutral flying lead and functional earth lead provided During interruption of the neutral conductor the protective function is guaranteed when FE & PE conductors are connected RESIDUAL CURRENT CIRCUIT BREAKERS (RCCBs) l Standards Compliance: EN6008 and IEC 6008 Rated Voltage: 30/400V, 50/60Hz RCD Class: Type AC Maximum Terminal Capacity: 35mm TECHNICAL DATA LOADSTAR TYPE B AND ROW DISTRIBUTION BOARDS l 50A List No. H 8LS04MR 768 8LS06MR 8 8LS08MR 876 8LSMR 984 8LS6MR 09 8LS0MR 00 8LS4MR 308 Add on enclosures List No. H List No. H 8DIN8 45 8AS 45 8DIN36 40 8AS 40 8SB 45 8AS3 570 8AS4 735 8AS5 85 Meter Packs 8MH50LP 740 45 430 surface Height H 55 overall Dual meter packs (LP) have a width equal to that of two distribution boards 0

Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products that caters for a vast array of applications including Commerce, Offices, Education, Hospitals & Health, Hotels & Leisure facilities, in fact wherever quality products are required. Crabtree factories operate a series of internationally recognized standards including ISO900 for quality, OHSAS 800 for Health & Safety and ISO400 for Environmental Management. The UK production locations are home to the product management, engineering, design, quality & logistics teams. In the UK Crabtree operates two UKAS accredited Laboratories that carry out R&D and compliance testing on all Crabtree products, these highly accredited facilities ensure that safety, quality & reliability remain consistent with UK & EU legislation regulations & Siemens internal standards, policies and practices. Crabtree products are all designed manufactured and tested in accordance with the recognised product standards, and backed by standard & extended guarantees. Crabtree also operates to recognised standards for product safety & sustainability, Crabtree wiring accessories are ROHS and REACH compliant often in excess of the UK market standards. Crabtrees WEEE compliance process and recycling scheme ensures that the end of product life circumstances are catered for in line with UK & EU Legislation. Recycled materials are used in product packaging, and declared into a recycling scheme locally to control environmental impacts and assure that the maximum level of recycling of materials and use of recycled materials is achieved. As a Siemens company Crabtree also operates a zero harm scheme within all of its manufacturing, logistics & sales facilities, and is proud to have achieved a 5 star Health & Safety rating.

ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS 0XE. email: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 0543 45500 Facsimile: 0543 4550 email: crabtree.sales@electrium.co.uk TECHNICAL Telephone: 0543 43830 Facsimile: 0543 4383 email: crabtree.technical@electrium.co.uk EXPORT SALES Telephone: +44 543 455049 Facsimile: +44 543 455048 email: export@electrium.co.uk DUBAI OFFICE Telephone: +97 4 3660684 Facsimile: +97 4 3660676 email: export@electrium.co.uk Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. B6 /5 Printed in England.