Fire resistant safety glass 1 1: 5 mm

Similar documents
PYROSWISS VETROFLAM CONTRAFLAM

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation

Product Selector. clear Fire resistant Glass

No smoke, no risk, no panic. Fire-resistant safety glass solutions

SCHOTT PYRANOVA Planline System

EN Insulating glass units, intended to be used in buildings and construction works

EN Insulating glass units, intended to be used in buildings and construction works

Classification of reaction to fire of glass products Recommendation from Glass for Europe

INFORMATION REGARDING GLASS TYPES AND PROPERTIES

Unbeatable energy efficient glass curtain wall system

Solar control right for you!

EN Insulating glass units, intended to be used in buildings and construction works

EN NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

This report should not be manipulated, abridged or otherwise presented without the written consent of International Fire Consultants Ltd

EN Insulating glass units, intended to be used in buildings and construction works

Window Glass Design 5 According to ASTM E 1300

Impact-Resistant Windows and Sliding Glass Doors

Linear thermal transmittance of the assembly of the glazing and the frame in windows

FIRE RATED GLAZING System Guide

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

PYROVITRO FIRE-RESISTANT GLASS

IMPORTANT NOTE Technical data and contents may

STADIP SILENCE SGG SGG CLIMALIT SILENCE. Enhanced acoustic insulation SGG CLIMAPLUS SILENCE SAINT-GOBAIN GLASS COMFORT

Fire-rated Aluminum Doors

CI/SfB Ro8 (K3) February Fire-Resistant Glass Range. Pilkington Pyrostop Pilkington Pyrodur Pilkington Pyroshield

FIREPROOF Panels Trimoterm

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

4 Insulating Glazing Terminology

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Thermal Breakage Prediction

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

EN Insulating glass units, intended to be used in buildings and construction works

ASI OEM Outdoor Solar Modules

CODE OF PRACTICE FOR USE OF GLASS IN BUILDINGS

Rockwool Flexi Insulation Application Guide

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

Pilkington Reflite Handling and Processing Guidelines Solar Control

MIROX 3G ENVIRONMENTALLY- FRIENDLY MIRROR

FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS

European Technical Assessment ETA-15/0652 of 27/10/2015

PYRAN PYRANOVA. Special-purpose glass products for fire resistant glazing

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Perfect Partitioning Solutions

Stiles. Basic Glass Guide. Steel Door + Window Systems CONTENTS

SOUND INSULATION FOR GLAZED DOORS AND STANDARD DOORS

EN Insulating glass units, intended to be used in buildings and construction works

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

FIRE GLASS TO GO! Fire Glass Solutions from

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

Assessing Curtain Walls

CERTIFICATE OF APPROVAL No CF 388 ALLEGION (UK) LIMITED

Passive Fire Protection

The Warm Edge for insulating glass

Fire-Rated Glass and Glazing START

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

Advantages & Benefits of Smart Glass How Does Smart Glass Work

Out - Ecrano / White Charcoal

Handling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass

The BASA Guide to the ISO Classification of Sealants for Building Construction

Double Glazed Units. Self-cleaning action Let nature do the work

Achieving BREEAM credits with advanced glazing products from NSG Group

Pyroguard Wired Glass

Technical information

NANSULATE NANOTECHNOLOGY BASED SOLUTIONS TO REDUCE HEAT LOSS THROUGH WINDOWS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

EXPERT OPINION on the applicability of the construction technology "GRÈMOUND non-tectonic system on grounds of the documentation submitted

Product Data. HexPly 8552 Epoxy matrix (180 C/356 F curing matrix)

iku windows the intelligent self cleaning window AUTOMATIC system

fr fire retardant MARMOLEUM

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

Europeiskt Tekniskt Godkännande European Technical Approval

Garden Windows Builders Vinyl

Roller Wave Distortion Definition, Causes and a Novel Approach to Accurate, On-line Measurement

Composite Panel Firewall Systems

Light-Weight Panels. High quality panels.

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications

II. ALL ABOUT GLASS.

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

Glass and Building Regulations Impact Safety

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

THERMOSTOP24 System PORTALEX ALUMINIO SA

European technical approval

SunGuard IS 20 Technical Information

Concepts. Products. Service. Glass partitions Lindner Life

Technical Information. What you need to know to BUILD WITH LIGHT

FederalDemocratic RepublicofEthiopia

Pilkington Activ and Pilkington Activ Blue. The world s first self-cleaning glass. Handling and Processing Guidelines. CI/SfB. Ro8 (K3) August 2007

For the modifications listed below, the Qualification Approval tests in IEC and IEC 61646, shall be used as a guideline by the assessor:

Standard Specification for Laminated Architectural Flat Glass 1

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Transcription:

SGG PYROSWISS SGG PYROSWISS 5 mm for interior and exterior application Fire resistant safety glass 1 1: 5 mm Fire resistance classification E 30 5 mm 200 x 300 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 12,5 kg/m 2 Light transmission (EN 410) 90% 32 db 5,8 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 6 mm for interior and exterior application Fire resistant safety glass 1 1: 6 mm Fire resistance classification E 30 6 mm 200 x 350 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 15 kg/m 2 Light transmission (EN 410) 89% 32 db 5,7 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 8 mm for interior and exterior application Fire resistant safety glass 1 1: 8 mm Fire resistance classification E 30 8 mm 200 x 300 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 20 kg/m 2 Light transmission (EN 410) 88% 34 db 5,7 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 10 mm for interior and exterior application Fire resistant safety glass 1 1: 10 mm Fire resistance classification E 30 10 mm 200 x 300 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 25 kg/m 2 Light transmission (EN 410) 88% 36 db 5,6 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 12 mm for interior and exterior application Fire resistant safety glass 1 1: 12 mm Fire resistance classification E 30 12 mm 200 x 300 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 30 kg/m 2 Light transmission (EN 410) 87% 37 db 5,7 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 15 mm for interior and exterior application Fire resistant safety glass 1 1: 15 mm Fire resistance classification E 30 15 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 37,5 kg/m 2 Light transmission (EN 410) 86% 38 db 5,5 W/m 2 K

SGG PYROSWISS SGG PYROSWISS 19 mm for interior and exterior application Fire resistant safety glass 1 1: 19 mm Fire resistance classification E 30 19 mm 200 x 300 mm 2000 x 4200 mm (oversizes upon request) ± 2 mm Weight 47,5 kg/m 2 Light transmission (EN 410) 84% 40 db 5,3 W/m 2 K

SGG PYROSWISS STADIP SGG PYROSWISS STADIP for interior and exterior application Fire resistant safety glass 1 1: 6 mm 2: 0,76 mm PVB film 2 Fire resistance classification E 30 Thickness tolerance 13 mm 250 x 400 mm 2000 x 4200 mm +1/ 1 mm see EN 12543 part 5 Weight 31 kg/m 2 Light transmission (EN 410) 87% UV stable 38 db 5,4 W/m 2 K As per EN ISO 12543-4 Pt.6

SGG PYROSWISS EXTRA SGG PYROSWISS EXTRA 5 mm for interior and exterior application Fire resistant safety glass 1 1: 5 mm Fire resistance classification E 30 E 60 5 mm 200 x 300 mm 1357 x 3297 mm ± 2 mm Weight 13 kg/m 2 Light transmission (EN 410) 90% 32 db 5,8 W/m 2 K Fire resistance classification

SGG PYROSWISS EXTRA SGG PYROSWISS EXTRA 6 mm for interior and exterior application Fire resistant safety glass 1 1: 6 mm Fire resistance classification E 30 E 90 6 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 16 kg/m 2 Light transmission (EN 410) 89% 32 db 5,7 W/m 2 K

SGG PYROSWISS EXTRA SGG PYROSWISS EXTRA 8 mm for interior and exterior application Fire resistant safety glass 1 1: 8 mm Fire resistance classification E 30 E90 8 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 21 kg/m 2 Light transmission (EN 410) 88% 34 db 5,7 W/m 2 K

SGG PYROSWISS EXTRA SGG PYROSWISS EXTRA 10 mm for interior and exterior application Fire resistant safety glass 1 1: 10 mm Fire resistance classification E 30 E90 10 mm 200 x 300 mm 1097 x 3297 mm ± 2 mm Weight 26 kg/m 2 Light transmission (EN 410) 87% 36 db 5,6 W/m 2 K

SGG PYROSWISS PLUS SGG PYROSWISS PLUS 6 mm for interior and exterior application Fire resistant safety glass 1 1: 6 mm Fire resistance classification E 30 6 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 15 kg/m 2 Light transmission (EN 410) 91% 32 db 5,7 W/m 2 K

SGG PYROSWISS PLUS SGG PYROSWISS PLUS 8 mm for interior and exterior application Fire resistant safety glass 1 1: 8 mm Fire resistance classification E 30 8 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 20 kg/m 2 Light transmission (EN 410) 91% 32 db 5,7 W/m 2 K

SGG VETROFLAM 30 SGG VETROFLAM 30 for interior and exterior application Fire rated safety glass 1 1: 6 mm Heat reflecting coating Fire resistance classification EW 30 6 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 15 kg/m 2 Light transmission (EN 410) 76% 32 db 3,8 W/m 2 K

SGG VETROFLAM 60 SGG VETROFLAM 60 for interior and exterior application Fire rated safety glass 1 1: 6 mm Heat reflecting coating Fire resistance classification EW 60 6 mm 200 x 300 mm 2000 x 4200 mm ± 2 mm Weight 15 kg/m 2 Light transmission (EN 410) 76% 32 db 3,8 W/m 2 K

SGG VETROFLAM STADIP 30 SGG VETROFLAM STADIP 30 for interior and exterior application. Asymmetric fire resistance. Fire resistant safety glass 1 1: 6 mm 2: 6 mm 3: 0,76 mm Toughened safety glass 2 Heat reflecting coating PVB film 3 Fire resistance classification EW 30 Thickness tolerance 13 mm 250 x 400 mm 2000 x 4200 mm +1/ 2 mm see EN 12543 part 5 Weight 31 kg/m 2 Light transmission (EN 410) 77% UV stable 36 db 5,4 W/m 2 K As per EN ISO 12543-4 Pt.6 Specific data for laminated safety glass and DGU make-ups on request.

SGG VETROFLAM STADIP 60 SGG VETROFLAM STADIP 60 for interior and exterior application. Asymmetric fire resistance. Fire resistant safety glass 1 1: 6 mm 2: 6 mm 3: 0,76 mm Toughened safety glass 2 Heat reflecting coating PVB film 3 Fire resistance classification EW 60 Thickness tolerance 13 mm 250 x 400 mm 2000 x 4200 mm +1/ 2 mm see EN 12543 part 5 Weight 31 kg/m 2 Light transmission (EN 410) 77% UV stable 36 db 5,4 W/m 2 K As per EN ISO 12543-4 Pt.6 Specific data for DGU make-ups on request.

SGG STADIP VETROFLAM 30 SGG STADIP VETROFLAM 30 for interior and exterior application. Symmetric fire resistance. Fire resistant safety glass 1 1: 6 mm 2: 0,76 mm Heat reflecting coating PVB film 2 Fire resistance classification Thickness tolerance EW 30 (EW60) 13 mm 250 x 400 mm 2000 x 4200 mm +1/ 2 mm see EN 12543 part 5 Weight 31 kg/m 2 Light transmission (EN 410) 66% UV stable 36 db 5,4 W/m 2 K As per EN ISO 12543-4 Pt.6

SGG CONTRAFLAM LITE SGG CONTRAFLAM LITE 30 for interior application Monolithic safety glass 1 Intumescent interlayer 1: 1500 x 3000 5 mm 1800 x 3210 6 mm 2200 x 3210 8 mm Spacer TPS Sealing polysulphide Fire resistance classification EW 30 Width tolerance 13 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2200 x 3210 mm (oversizes upon request) +2/ 1 mm +2/ 2 mm Weight 30 kg/m 2 Light transmission (EN 410) 87% UV stable Temperature range 37 db 5,2 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for laminated safety glass and DGU make-ups on request.

SGG CONTRAFLAM LITE SGG CONTRAFLAM LITE 60 for interior application Monolithic safety glass 1 Intumescent interlayer 1: 1500 x 3000 5 mm 1800 x 3210 6 mm 2200 x 3210 8 mm Spacer TPS Sealing polysulphide Fire resistance classification EW 60 Width tolerance 14 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2200 x 3210 mm (oversizes upon request) +3/ 1 mm +2/ 2 mm Weight 31 kg/m 2 Light transmission (EN 410) 87% UV stable Temperature range 37 db 5,1 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for laminated safety glass and DGU make-ups on request.

SGG SWISSFLAM LITE SGG SWISSFLAM LITE 30 for interior application Verbund-Sicherheitsglas Laminated safety glass Aufschäumende Zwischenschicht Intumescent interlayer Abstandhalter TPS Versiegelung Polysulfid Sealing polysulphide Fire resistance classification EW 30 Width tolerance 14 mm 190 x 350 mm 2250 x 3210 mm (oversizes upon request) +2/ 1 mm +2/ 2 mm Weight 31 kg/m 2 Light transmission (EN 410) 85% UV stable Temperature range 40 db 5,1 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Laminated safety glass As per EN ISO 12543

SGG SWISSFLAM 30 SGG SWISSFLAM 30 for interior application Laminated safety glass Intumescent interlayer Sealing polysulphide Fire resistance classification EI 30 Width tolerance 17 mm 190 x 350 mm 2250 x 3210 mm (oversizes upon request) +2/ 1 mm +2/ 2 mm Weight 35 kg/m 2 Light transmission (EN 410) 85% UV stable Temperature range 40 db 4,7 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Fire resistance classification As per EN ISO 12543

SGG SWISSFLAM 60 SGG SWISSFLAM 60 for interior application Laminated safety glass Float glass Intumescent interlayer Sealing polysulphide Fire resistance classification EI 60 Width tolerance 25 mm 190 x 350 mm 2250 x 3210 mm (oversizes upon request) +3/ 2 mm +2/ 2 mm Weight 52 kg/m 2 Light transmission (EN 410) 83% UV stable Temperature range 43 db 4,2 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Fire resistance classification As per EN ISO 12543

SGG CONTRAFLAM 30 SGG CONTRAFLAM 30 for interior application Toughened safety glass 1 Intumescent interlayer 1: 1500 x 3000 5 mm 1800 x 3210 6 mm 2200 x 3210 8 mm Spacer TPS Sealing polysulphide Fire resistance classification EI 30 Width tolerance 30 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2250 x 3210 mm (oversizes upon request) +2/ 1 mm +2/ 2 mm Weight 34 kg/m 2 Light transmission (EN 410) 87% UV stable Temperature range 38 db 4,8 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for DGU make-ups on request.

SGG CONTRAFLAM 60 SGG CONTRAFLAM 60 for interior application Toughened safety glass 1 Heat-strengthened or toughened glass 2 Intumescent interlayer Spacer TPS 1: 1500 x 3000 5 mm TSG 1800 x 3210 6 mm TSG 2200 x 3210 8 mm TSG 2: 1200 x 2400 3 mm HSG 1500 x 2500 4 mm TSG 1500 x 2500 see above 1: Sealing polysulphide Fire resistance classification EI 60 Width tolerance 24 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2200 x 3210 mm (oversizes upon request) +3/ 2 mm +2/ 2 mm Weight 49 kg/m 2 Light transmission (EN 410) 83% UV stable Temperature range 41 db 4,3 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for DGU make-ups on request.

SGG CONTRAFLAM 90 SGG CONTRAFLAM 90 for interior application Tempered safety glass 1 Tempered safety glass 2 Intumescent interlayer Spacer TPS Sealing polysulphide 1: 1500 x 3000 5 mm TSG 1800 x 3210 6 mm TSG 2200 x 3210 8 mm TSG 2: 1200 x 2400 3 mm HSG 1500 x 2500 4 mm TSG 1500 x 2500 see above 1: Fire resistance classification EI 90 Width tolerance 36 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2200 x 3210 mm (oversizes upon request) +3/ 2 mm +2/ 2 mm Weight 72 kg/m 2 Light transmission (EN 410) 80% UV stable Temperature range 44 db 3,7 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for DGU make-ups on request.

SGG CONTRAFLAM 120 SGG CONTRAFLAM 120 for interior application Tempered safety glass 1 Tempered safety glass 2 Intumescent interlayer Alu spacer 3 Spacer TPS Sealing polysulphide 1: 1500 x 3000 5 mm TSG 1800 x 3210 6 mm TSG 2200 x 3210 8 mm TSG 2: 5 mm 3: 6 mm Fire resistance classification EI 120 Width tolerance 58 mm (nominal thickness for smallest pane sizes) 190 x 350 mm 2200 x 3210 mm (oversizes upon request) +5/ 3 mm +2/ 2 mm Weight 108 kg/m 2 Light transmission (EN 410) 70% UV stable Temperature range 2,3 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C Specific data for DGU make-ups on request.

SGG SWISSFLAM STRUCTURE 30 SGG SWISSFLAM STRUCTURE 30 for interior application Wet sealing Dry sealing 1: Laminated safety glass 2: Intumescent interlayer 3: Sealing polysulphide 4: Kerafix Blähpapier +3:2 pcs 2 x 8 mm 5: Sealing 6: Glue 7: Silicone profile I: Ground edge II: Arris edge Fire resistance classification EI 30 Width tolerance 23 mm 250 x 350 mm 1950 x 3150 mm +2/ 1 mm +1,5/ 0,5 mm Weight 50 kg/m 2 Light transmission (EN 410) 84% UV stable Temperature range 42 db 4,5 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C

SGG SWISSFLAM STRUCTURE 60 SGG SWISSFLAM STRUCTURE 60 for interior application Wet sealing 1: Laminated safety glass 2: Float glass 3: Intumescent interlayer 4: Kerafix Blähpapier +3:2 pcs 2 x 8 mm 5: Sealing 6: Glue 7: Silicone profile I: Ground edge II: Arris edge Dry sealing Fire resistance classification EI 60 Width tolerance 32 mm 250 x 350 mm 1950 x 3150 mm +2/ 1 mm +1,5/ 1,5 mm Weight 65 kg/m 2 Light transmission (EN 410) 81% UV stable Temperature range 44 db 4,0 W/m 2 K As per EN ISO 12543-4 Pt.6 +45 C/ 10 C