SUNOPTICS SVT Industrial Smoke Vent

Similar documents
INSTALLATION GUIDE TH STREET SACRAMENTO, CA U.S.A TOLL FREE PHONE

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

1000-LB. TRAILER JACK OWNER S MANUAL

Owner s Manual & Safety Instructions

Basement Window Installation Guide Hopper and Sliding

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

3 WATT LED SPOTLIGHT Model No. SLM

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

15GAL STEEL OIL DRAIN WITH 110V PUMP

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Greenhouse Assembly Instructions

Digital Fingerprint safe

CARING FOR YOUR WATER HEATER

Model 1756 Test Lead Kit

W850. Maintenance Guide

Owner s Manual & Safety Instructions

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Active and Passive Sash Replacement

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

3 IN 1 BATHROOM HEATER

Ceiling Mounted Folding Attic Ladders Installation Instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Combination Unit 5'6" Windows a i o P t

lamp post light Set up and Operating Instructions

Installation Instructions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

SOLAR PV SYSTEM MAINTENANCE GUIDE

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

SCION tc DASH APPLIQUE Preparation

HYDRAULIC LIFT TABLE CART 2200-LB.

National- Spencer Inc.

Bathroom Installation Guide

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

In-Ground Basketball System Owners Manual

Sun Windows General Information Sun New Construction Window Installation Instructions

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

PNEUMATIC PLANISHING HAMMER

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

tire inflator with pressure gauge

12 WATT LED AMBER LIGHT BAR

Mini-led spotlight with magnetic base

Owner s Manual Gantry Cranes

PAINT SPRAY GUN WASHER

staple gun with 5/16 Long staples

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

OWNER S MANUAL Table Tennis Table Patent Pending

Infrared dome ccd camera User Manual

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

3/4 PIPE CLAMP WITH STAND

PEDAL CAR - GO CART ASSEMBLY & OPERATING INSTRUCTIONS

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Window Installation Instructions

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Dehumidifier Users manual. For Models: DH45S DH65S

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

INFRARED QUARTZ WALL HEATER

GAS SAFETY PRECAUTIONS

INTRODUCTION INTERLOCK KIT K-8110

8" BENCH GRINDER OWNER'S MANUAL

ACTIV board User Guide

Packaged Terminal Air Conditioner Wall Sleeve Installation

LED Security Spotlight User Manual

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Step 1. Item 6. Item 1

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN7000S

NFC Communication Tray Model: HHX-IT3-Z

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

GENUINE PARTS INSTALLATION INSTRUCTIONS

San josé OWNER S MANUAL

Combination Unit (shown from interior) WARNING

R O A D M A S T E R, I N C.

7. PRINCIPAL STEPS 8. POTENTIAL HAZARDS 9. RECOMMENDED CONTROLS

Hydraulic Punch Driver Kit

C790 Series. Maintenance Guide

Basic Spring Motor Roller Shades

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

HYDRAULIC TABLE CART 500-LB.

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

75th anniversary blender

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Fabric Replacement Top Installation Instructions

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Generator Transfer Switch Model # HTS15-AUTO

MODEL T-4 TRENCHER. Operators Manual

aseries A13B Mini Bullet Camera User Manual

Installation Instructions for Alarm Module Kit A043F059

Transcription:

SUNOPTICS SVT Industrial Smoke Vent INSTALLATION GUIDE

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the smoke vent assembly equipment. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of the smoke vent assembly should be performed by a qualified person. Maintenance of the smoke vent assembly should be performed by person(s) familiar with the smoke vent assembly s construction and operation and any hazards involved. Regular smoke vent assembly maintenance programs are recommended. It will occasionally be necessary to clean the outside of the smoke vent assembly. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. The smoke vent lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should the smoke vent lens become dirty on the inside, wipe the smoke vent lens and clean it in the above manner. DO NOT INSTALL DAMAGED PRODUCT! This smoke vent assembly has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING RISK OF ELECTRIC SHOCK CAUTION RISK OF INJURY Wear gloves and safety glasses at all times when installing, servicing or performing maintenance to the smoke vent assembly. Disconnect or turn off power before installation or servicing. Be aware of power near the installation area of the smoke vent assembly. Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com Our Brands Indoor/Outdoor Lithonia Lighting Carandini Holophane RELOC Light Concepts Indoor Lighting Gotham Mark Architectural Lighting Peerless Renaissance Lighting Winona Lighting Outdoor Lighting American Electric Lighting Antique Street Lamps Hydrel Tersen Controls DARK TO LIGHT LC&D ROAM Sensor Switch Synergy Daylighting SunOptics Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10 ABL General Warnings, Form No. 503.204 2

WARNING - Read the entire installation manual, along with the following warnings, prior to proceeding with the installation of the unit. This installation manual provides minimum installation information for the SVT unit. This manual also provides minimum design information and a brief description for the SVT unit. All details, drawings and images shown in this manual are not to scale. The design, specifications and exceptions are subject to changes without notice. Each revised version of this installation manual supersedes all previous versions. Please contact your local Acuity Brands Lighting Inc. representative with regards to updates to the product, design, specifications and/or installation instructions. Please contact an Acuity Brands Lighting Inc., or Sunoptics, representative with regards to the use of materials or methods, which are not specified in this manual, or authorized by Acuity Brands Lighting, Inc. Acuity Brands Lighting Inc. (seller) assumes no responsibility or obligation whatsoever for the failure of an installer, contractor, architect or building owner to comply with all applicable laws, ordinances, building codes, electrical codes, energy codes, fire and safety codes and requirements, roof warranties and adequate safety precautions. The installation of the SVT should be done by at least 2 people. The second person should be close enough to come to your aid, if necessary. INSTALLATION TO BE DONE AT YOUR OWN RISK! GENERAL SAFETY Acuity Brands Lighting Inc. product installations may be dangerous and include the potential for death, personal injury and property damage. Some of the hazardous conditions include, but are not limited to, the following: Installation will require working at dangerous heights. When working on ladders, scaffolding, on roofs and in attic spaces, use extreme caution to minimize risks, property damage, personal injury, or death. Use the following procedures, as well as other measures, as examples to reducing risk. Clearing the area(s) below the working space or objects, animals and people. Use proper footwear. Using footwear with excellent traction is recommended. Avoid working on slippery, or wet, surfaces. Supports such as ladders and scaffolding should be well supported and strong. Install the product during calm and dry weather. When working in attic spaces, use the following precautions: Most attic spaces are dark, so use portable lighting such as flashlights to properly light the working area. Always support your weight on structurally sound framing. Do not step on the drywall material because drywall is not designed to carry a person s weight. It is recommended to use respirators, or masks, to avoid lung irritation. Use basic safety procedures when working with electric tools. Use suitable eye protection, such as safety goggles, and clear the work area of electrical wires, gas pipes, water pipes and other obstacles to reduce the risk of fire, electric shock and personal injury. The SVT is not designed to support the weight of a person, tools or other materials. If the product is damaged, do not continue with the installation and immediately contact your Acuity Brands Lighting Inc., or Sunoptics, representative for instructions and a replacement. ROOFING If the SVT unit must be removed from the roof, due to re-roofing, please contact your Acuity Brands Lighting, or Sunoptics, representative for information on disassembly and care of the unit. 3

RECOMMENDED TOOLS and MATERIALS: Screw Gun with 5/16 Driver Screw Gun with Flat Head Tape Measure Lumber Crayon Hammer Required Safety Equipment PARTS LIST ITEM DESCRIPTION 1 870B SMOKE VENT ASSEMBLY 1 2 #12 HEX HEAD DRILL TIP SCREWS 3 OPTIONAL ITEMS 3 CLOSURE BAR 4 QTY 1 X3 1 NOTES: X - Quantity Required is based on application and Customer Order. 1) CAUTION: Handle Skylight Material with Care. 2) Components shown not included in all kits. See label on box. 3) Amount of screws is based on size selected. 4) A Closure Bar is recommended when closing 25LB & 30LB Rated Units ** Verify all materials are on site, and available for installation. 1 2 10 FT 3 4

SYSTEM INSTALLATION TIPS When using a Smoke Vent Assembly, be sure there is approximately 7-1/2 inches of clearance between the top of the Curb and the first obstruction, i.e. Security Bars, specifically for the Fusible Link Release Trigger. Limiting the movement of the Release Trigger may cause the vent doors to not open, as required. CURB ROOF 7-1/2 inches OBSTRUCTION RELEASE TRIGGER Be sure to have at least 24 of clearance behind the Manual Release side. Leave enough room for a person to easily access, and operate, the Manual Release Cable. 24 inches SMOKE VENT ASSEMBLY MANUAL RELEASE CABLE 5

INSTALLATION INSTRUCTIONS ROOF PREPARATION 1. Prior to installation, prepare the roof and create an opening which will utilize the provided Smoke Vent Assembly. 2. Install the proper size Curb (not provided) onto the roof. ROOF OPENING CURB (PROVIDED BY OTHERS) ROOF UNIT PREPARATION 1. Inspect the unit for any damage. 2. Be sure that the Shipping Plate on both ends of the unit are still installed. The plates ensure that the Vent Doors are closed during installation. 6

INSTALLATION INSTRUCTIONS INSTALLATION OF THE SMOKE VENT UNIT 1. Carefully set the Smoke Vent Assembly over the prepared Curb. Make sure the Smoke Vent Unit is square and flat. 2. Move the Smoke Vent Unit on the curb such that there is an equal amount of clearance between the ID frame and the Curb, SMOKE VENT UNIT front-to-back, and side-to-side. CURB (PROVIDED BY OTHERS) NOTE: While moving the Smoke Vent Assembly, be sure to support each corner of the assembly, and ensure that the assembly does not twist. (See image). Twisting of the unit may cause the internal components of the unit to misalign, and therefore not function properly. EXAMPLES OF TWISTING *CURB FRAME ONLY SHOWN FOR CLARITY NOTE: When installing the Smoke Vent Assembly onto the curb, be sure that each corner of the assembly is secure and that the frame is square and flat. Ensure that the frame is square. (See image). Misalignment of the unit may cause the internal components of the unit to misalign, and therefore not function properly. INCORRECT INSTALLATION. FRAME NOT SQUARE 7

INSTALLATION INSTRUCTIONS INSTALLATION OF THE SMOKE VENT UNIT (CONT.) 3. Secure the Smoke Vent Assembly onto the Curb using the Drill Tip Screws provided. Drive the screws just snug to the Curb Frame Flange. Check the Smoke Vent Assembly for squareness and readjust the screws, if necessary. #12 SCREWS NOTE: Install the screws for the corners of the Curb Frame, in a star pattern as shown. Ensure equal spacing all around, between the Curb and the Curb Frame, and that the unit is square. After installing the corner screws, continue installing the remaining screws for the Curb Frame. 6 8 4 2 1 3 7 5 8

INSTALLATION INSTRUCTIONS INSTALLATION OF THE SMOKE VENT UNIT (CONT.) NOTE: When securing the Smoke Vent Assembly onto the Curb, drive the screws just snug to the Curb Frame flange. (SEE BELOW) Overtightening the screws may distort the Flange and in turn create forces which may cause the internal components of the unit to misalign, and therefore not function properly. CORRECT MOUNTING INCORRECT MOUNTING 4. Remove the 2 Transporting Safety Plates (1 at each end). Remove the plates ONLY after the Smoke Vent Assembly has been secured on the Curb. TRANSPORTING SAFETY PLATES 9

INSTALLATION INSTRUCTIONS TESTING THE SMOKE VENT UNIT, VENT DOORS 1. Pull the Exterior Release Cable to test each Venting Door section for proper operation. CLOSE ENDS AT THE SAME RATE WARNING: Stand clear of the Vent Door sections when testing the unit. VENT DOOR CLOSE ENDS AT THE SAME RATE EXTERIOR RELEASE CABLE 2. While the Vent Doors are open, unwind the Internal Release Cables, from the center Mullion. The Internal Release Cables should be hanging down, as shown in the diagram. MULLION INTERNAL RELEASE CABLE 3. After testing the Vent Doors, return each Vent Door section to the closed position. NOTE: It will require 2 persons to close the Vent Doors, with 1 person on each end of the door. When closing the Vent Doors, make sure each end of the door is moving to the closed position at the same even rate. 10

SMOKE VENT MAINTENANCE SHEET SUNOPTICS SMOKE VENTS generally require very little maintenance to properly perform for many years. However, as with all products, a scheduled preventative maintenance program should be followed. CLEANING ACRYLIC LENSES 1. When cleaning acrylic lenses, use only water or water with a mild soap. Use a soft rag to minimize scratching the acrylic. 2. NEVER use ammonia, aromatic or petroleum based products to clean acrylic lenses. This will certainly cause deterioration and cracking of the lens and will void the warranty. 11

INSTALLATION NOTES 12