The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity



Similar documents
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Protecting Our Information, Protecting Our Resources

How To Make A Data Center More Efficient

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

Hiwall Hiross for Telecom. High Performance Air Conditioning

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Protecting The Critical IT Infrastructure of the United States

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

How To Save Energy On A Power Supply

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

CoolTeg Plus Chilled Water (CW) version: AC-TCW

ECOCIAT. Domestic hot water heat recovery unit

Tech Byte 27: Small Computer Room and IT Closet Cooling

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

- White Paper - Data Centre Cooling. Best Practice

york air-conditioning products Residential & VRF News 2015

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

KONRAD. Hybrid Fancoil Series

State of the Art Energy Efficient Data Centre Air Conditioning

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

How To Run A Data Center Efficiently

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Liebert SiteScan Web. Quick-Start Guide. Monitoring For Business-Critical Continuity

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity


R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

FULL DC INVERTER SYSTEMS

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

AIRAH Presentation April 30 th 2014

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Elements of Energy Efficiency in Data Centre Cooling Architecture

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

Microsoft Technology Center: Philadelphia

Chilled Water Precision Air Conditioner For Critical Application

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Mechanical Rooftop Custom Capabilities

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

CRAC Precision climate control units for data centres

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SECTION MORTUARY REFRIGERATORS

News in Data Center Cooling

NetSure DC Power Solutions with esure High-Efficiency Technology. DC Power for Business-Critical Continuity TM

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

High Performance Air Conditioning. Himod 4-80 kw Indoor Room Cooling Units

Bring the fresh in. Dedicated Outside Air Systems

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Refrigeration Compressed Air Dryer Buran Ultrapulse

Power and Cooling Best Practices for IP Communications. A White Paper from the Experts in Business-Critical Continuity

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

DCF Optimized Rack System

NetSure DC Power Solutions with esure High-Efficiency Technology

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

APC APPLICATION NOTE #112

DUCTED AIR CONDITIONING SOLUTIONS

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

RPV - RP - RA air handling units

Cooling kw Heating kw

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

ASTACEA4 Inspect complex/central air conditioning systems

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

Precision versus Comfort Cooling Choosing a Cooling System to Support Business-Critical IT Environments

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

In addition to the equipment heat load the room / enclosure will also provide heat gains through the building structure and environment.

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Failure code manual. content

FTQ. Daikin Inverter Ducted Heat Pump

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

STULZ View On DataCenter Cooling

HVAC Systems: Overview

HVAC Infrastructure Retrofit Solutions

Rack Power Distribution Unit For Critical IT Equipment

Combi Unit Genius. The energy efficient Building Service Centre

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Transcription:

Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity

We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions for the benefit of our customers. We re the world leader in providing Business-Critical Continuity to organizations like yours, enabled by our product and service centres of expertise. Telecom sites / Technological environments For wireless telecom applications, we provide control of remote access node environmental conditions. Our product portfolio includes a wide range of configurable solutions; outdoor packaged wall-mounting cooling system for shelters, when there s not enough space available inside the site; indoor packaged floor standing cooling system, to remotely reject, the heat generated by electronic equipment from IT rooms inside buildings; split system, to adapt the cooling solution to whatever site position, dimension and layout.

Product overview The Liebert HPF represents the most complete package indoor cooling system product family specifically designed to control the environmental conditions in technological or industrial rooms as well as inside Fixed and Mobile Telecom Network sites. The Liebert HPF units are designed for indoor and floor-mount application with over under or displacement air delivery. In direct expansion mode the priority is given to the energy saving that is reached through the attention given at design level to all processes that realize the cooling effect: high fan efficiency, perfect unit insulation, performing heat exchange, smart logic control. The use of direct free-cooling mode is tuned to enhance the respect of the environment trough the setting of the control that aim to minimize the waste of energy in every condition. The possibility to switch in emergency cooling mode, through the use of 48VDC or 230VAC plug fan, assure the continuity of protection from the risk of working in improper climatic conditions

Availability Site protection continuity despite of the application threats Providing the needed quality to the cooling effect Protecting the site from the attacks of the external environment it s not a game. Liebert HPF cleans the air trough an efficient filtering system easy to be serviced and maintained; Liebert HPF cools the air through the lowest energy consumption thanks to the use of high class components; Liebert HPF avoids the waste of the obtained cooling effect through the high care of the unit panels insulation. Riding any critical conditions When the external temperature rises to the unexpected temperature, when the environment hazard the air filtering system, when the indoor temperature, for any reason creates the hot start condition, the cooling system can t abandon your application. The availability of high ESP fan means capacity to react to the unwilled situation that could jeopardize your business. Continuity of revenue from the site Liebert HPF can be powered by 48VDC emergency power source in case of mains failure. Continued ventilation and the maximized freecooling mode assure constant operation of the telecommunications equipment. The 230V AC emergency supply is also available for applications offering the assistance of UPS or AC generator systems.

Refrigerant circuit High efficiency compressor Dryer filter Sigh glass Insulation from air stream Air filtration EU3 class standard filter Up to EU7 high filtration Full frontal access Condenser fan Plug type fan High ESP availability Speed control

Flexibility Cooling the application has no impact on the project Always delivering cooling to its target The delivery of the treated air is fundamental to cool the site with efficiency and effectiveness. Cooled air must be supplied where it is needed: depending from the site layout the application could require the air distribution from grilles through a false floor, from top ducts or through the ceiling, directly at floor level to cool the electronic equipment. This is exactly what Liebert HPF is asked to do and does in the under, the over and the displacement version. Suitable to critical indoor installations Technological environmnets inside historical buildings as well as telecom sites in high rise buildings are often located in sites where the supply of the external air is critical and it is not allowed to install external units. The heart of the communication needs a cooling system for indoor application able to guarantee the most effective air intake system through the use of high ESP fans, self adapting to the pressure drops of the site ducting, in order to provide efficiency of the cooling cycle when working in direct expansion and highest energy saving when working in free-cooling mode. Providing freedom of site layout at the design stage The use of an indoor package cooling system can t prevent from letting the right space and position to the electronic rack. At this purpose Liebert HPF gives the possibility of being installed wherever it is allowed: in the middle of the room with rear connection to the remote wall or in a corner with lateral connection directly to the side of the building. The Liebert HPF compactness and configurability don t limit the user freedom of drawing the most suitable site layout.

under floor air delivery over air delivery floor level (displacement) air delivery back outdoor air connections lateral outdoor air connection

Total Cost of Ownership Attention to costs and care of the environment Easy of installation and fast start up The cooling circuit is pre-charged, fine tuned and fully tested before the delivery. No pressure test is required on site. Installation is furthermore speeded up by using the fast plug electrical connections (on request) and the automatic commissioning software: installation and commissioning are completed in less than 25 mins. without need of specialized personnel on site. Generating high energy saving with cooling lifetime extension A close control cooling system is required to work 24 hours a day, 365 days a year: the must is to minimize the demand of energy supply in order to be cheaper to run and to prevent the impact on climate change. Liebert HPF aims to maximize the energy saving without compromising its effectiveness. The EC fan version reduces by 30% the energy consumption of the evaporating fan, compared to the traditional AC fan motors. To the results obtained with its high cooling efficiency, Liebert HPF adds the savings guaranteed by the free-cooling mode and maximized through the use of modulating fans either AC or DC supplied; when the fresh air is available the compressor and the condenser fan stop as well as the evaporator fan limits its speed in order to adapt the cooling capacity to the application heat load, with highest energy saving when working at partial loads conditions. As consequence the lifetime of the cooling unit is extended with delay of its replacement time. Facilitating the service Liebert HPF guarantees easy and speed of access to all main components during the ordinary maintenance increasing the effectiveness of the service action worked out in perfect safety conditions. The need of extraordinary maintenance is reduced to a minimum thanks to the quality of the components selected at the design level.

Control Team-working with up to 16 units Stand by, rotation and cascade modes Standard 3 digit display Optional graphic display with storage of last 200 events Free-cooling system From 0 to 100% damper modulation 48V DC or 24V AC power supplied Free-cooling fan modulation Evaporator fan Plug type fan High ESP availability 48V DC or 230V AC power supplied High efficiency EC fan version

Technical Data Displacement (D Version) 48 VDC Version EC FAN Version Model 5 7 10 12 15 5 7 10 12 15 Performances Main power supply Emergency power supply 230 / 1N / 50 400 / 3N / 50 48V DC 230 / 1N / 50 400 / 3N / 50 230 V AC Total cooling capacity (1) kw 5,0 7,3 12,3 14,4 16,3 5,0 7,3 12,3 14,4 16,3 Sensible cooling capacity (1) kw 5,0 7,3 12,3 14,2 16,0 5,0 7,2 12,3 14,2 16,1 SHR (1) - 1 1 1 0,99 0,98 1,00 0,99 1,00 0,99 0,99 Compressor AC power input (1) kw 1,19 2,10 2,88 3,62 4,69 1,19 2,10 2,88 3,62 4,69 Evaporator fan power input (1) kw 0,21 0,28 0,44 0,54 0,66 0,21 0,26 0,42 0,50 0,60 Condenser fan AC power input (1) kw 0,70 0,72 0,97 1,06 1,19 0,70 0,72 0,97 1,06 1,19 Evaporator airflow (4) m 3 /h 1800 1800 3060 3350 3580 1710 1800 2850 3080 3390 Z.E.T (100% Cooling Capacity) (5) C 21,8 17,8 15,8 16,3 15,6 22,5 19,0 15,4 17,5 15,8 Z.E.T (50% Cooling Capacity) (5) C 25,9 23,9 22,9 23,1 22,8 26,2 24,5 22,7 23,7 22,9 Condenser max. airflow (4) m 3 /h 2740 2740 4830 4830 4830 2740 2740 4830 4830 4830 Outdoor SPL (2) db(a) 57,0 58,0 59,5 61,0 62,5 57,0 58,0 59,5 61,0 62,5 Indoor SPL (2) db(a) 50,0 51,0 62,5 62,5 63,0 50,0 51,0 63,0 61,0 63,0 Max. ambient temperature (3) C 52,0 46,5 50,0 48,0 45,0 52,0 46,5 50,0 48,0 45,0 Technical Data Under (U Version) 48 VDC VERSION EC FAN VERSION Model 5 7 10 12 15 5 7 10 12 15 Performances Main power supply Emergency power supply 230 / 1N / 50 400 / 3N / 50 48 V DC 230 / 1N / 50 400 / 3N / 50 230 V AC Total cooling capacity (1) kw 4,9 7,2 11,1 12,9 15,3 4,9 7,2 11,1 12,9 15,7 Sensible cooling capacity (1) kw 4,9 6,6 10,5 12,0 13,4 4,9 6,6 10,5 12,0 13,7 SHR (1) - 1,00 0,92 0,95 0,93 0,88 1,00 0,92 0,95 0,93 0,87 Compressor AC power input (1) kw 1,20 2,10 2,91 3,64 4,67 1,20 2,10 2,91 3,64 4,69 Evaporator fan power input (1) kw 0,28 0,34 0,45 0,56 0,66 0,26 0,30 0,42 0,50 0,60 Condenser fan AC power input (1) kw 0,70 0,72 0,95 1,03 1,17 0,70 0,72 0,95 1,03 1,19 Evaporator air flow (4) m 3 /h 1890 2020 2850 3110 3310 1800 2000 2740 3100 3280 Z.E.T (100% Cooling Capacity) (5) C 18,1 15,1 14,9 14,3 14,0 19,0 16,3 14,7 16,8 15,2 Z.E.T (50% Cooling Capacity) (5) C 22,5 21,0 21,0 20,7 20,5 23,0 21,6 20,7 21,9 21,1 Condenser max. airflow (4) m 3 /h 2740 2740 4830 4830 4830 2740 2740 4830 4830 4830 Outdoor SPL (2) db(a) 57,0 58,0 57,5 61,0 62,5 57,0 58,0 57,5 61,0 62,5 Indoor SPL (2) db(a) 49,5 50,5 54,5 54,5 57,5 45,0 48,0 52,5 52,5 55,5 Max. ambient temperature (3) C 52,0 46,5 50,5 48,5 45,0 52,0 46,5 50,5 48,5 45,0

Liebert HPF Under Liebert HPF Over Liebert HPF Displacement Technical Data Over (O Version) 48 VDC VERSION EC FAN VERSION Model 5 7 10 12 15 5 7 10 12 15 Performances Main power supply Emergency power supply 230 / 1N / 50 400 / 3N / 50 48V AC 230 / 1N / 50 400 / 3N / 50 230 V DC Total cooling capacity (1) kw 4,9 7,1 11,3 13,2 15,7 4,9 7,1 11,3 13,2 15,9 Sensible cooling capacity (1) kw 4,9 6,4 10,5 11,6 13,1 4,9 6,4 10,5 11,6 13,4 SHR (1) - 1,00 0,90 0,93 0,88 0,83 1,00 0,90 0,93 0,88 0,84 Compressor AC power input (1) kw 1,20 2,10 2,90 3,63 4,67 1,20 2,10 2,90 3,63 4,68 Evaporator fan power input (1) kw 0,28 0,33 0,45 0,54 0,64 0,26 0,30 0,42 0,52 0,60 Condenser fan AC power input (1) kw 0,70 0,72 0,96 1,04 1,18 0,70 0,72 0,96 1,04 1,18 Evaporator airflow (4) m 3 /h 1780 1910 2710 2870 3070 1730 1960 2780 3190 3320 Z.E.T (100% Cooling Capacity) (5) C 16,9 14,7 14,0 13,5 12,7 18,6 16,5 14,0 17,1 14,9 Z.E.T (50% Cooling Capacity) (5) C 21,9 20,8 20,5 20,2 19,9 22,8 21,8 20,5 22,1 21,0 Condenser max. airflow (4) m 3 /h 2740 2740 4830 4830 4830 2740 2740 4830 4830 4830 Outdoor SPL (2) db(a) 57,0 58,0 58,0 61,0 62,5 57,0 58,0 58,0 61,0 62,5 Indoor SPL (2) db(a) 58,5 60,5 62,0 60,5 62,0 58,0 60,5 62,0 60,5 62,5 Max. ambient temperature (3) C 52,0 46,5 50,5 48,5 45,0 52,0 46,5 50,5 48,5 45,0 Technical Data Unit description Model 5 7 10 12 15 Compressor type / quantity Refrigerant Expansion device Evaporator fan type / quantity AC Evaporator fan type / quantity DC Condenser fan type / quantity Scroll / 1 R407C Thermostatic valve Plug / 1 Plug / 1 Plug / 1 Condenser fan speed control Filter type / efficiency Continuosly variable speed Pleated / G3 Electrical heating (option) kw Frame 1,5 3 4,5 Galvanized steel 6 6 Painting Insulation type Polyester - Charcoal grey/ral7035 Polyethylene / polyurethane foam, class 1 Width / Depth / Height (D version) mm 650 / 650 / 1990 900 / 750 / 2300 Width / Depth / Height (O-U) mm 650 / 650 / 1990 900 / 750 / 2050 Weight (D version) kg 197 200 288 315 320 Weight (U version) kg 197 200 288 290 295 Weight (O version) kg 197 200 288 290 295 (1) Values are referred to 35 C outdoor temperature, to nominal power supply and the following indoor conditions: - 30 C/39,5%R.H. at the evaporating air intake side for Displacement models - 27 C/47%R.H. at the evaporating air intake side for Under and Over models (2) Measured with 35 C outdoor temperature, at 2m from the unit, in free field conditions (3) Referred to: - 30 C/39,5%R.H. at the evaporating air intake side for Displacement models - 27 C/47%R.H. at the evaporating air intake side for Under and Over models (4) - Referred to 50 Pa as External Static Pressure (ESP). (5) -Z.E.T.: Zero Energy Temperature, air temperature at which the freecooling mode is able to supply 100% or 50% of the Direct Expansion sensible cooling capacity.

104154 Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity. The company is the trusted source for custom, adaptive and ultra-reliable solutions that enable and protect its customers business-critical technology infrastructures. Backed by the largest global services organization in the industry, Emerson Network Power offers a full range of innovative power, precision cooling, connectivity and embedded products and services for computer, communications, healthcare and industrial systems. Key product brands within the Emerson Network Power family include Liebert, Knuerr, ASCO, Astec, Lorain. Emerson Network Power Srl Liebert Business EMEA Headquarters Via Leonardo da Vinci 16/18 35028 - Piove di Sacco (PD) - Italy tel. +39 0499719111 fax +39 0495841257 marketing.emea@emersonnetworkpower.com Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX Emerson Network Power. The global leader in enabling business-critical continuity TM. www.eu.emersonnetworkpower. com marketing.emea@emersonnetworkpower.com AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Out Side Plant Power Switching e Controls Precision Cooling Rack & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2008 Emerson Electric Co.