Caution: Safety Precautions: Installation, Operation & Maintenance Manual. For Modentic Two Way Ball Valves

Similar documents
INSTALLATION, OPERATION & MAINTENANCE MANUAL

Float and Thermostatic Traps Series H, C and X

RMF Engineering

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

2" & 3" Poly Wet Seal Pump Instruction Manual

RUBBER SLEEVE KNIFE GATE VALVE

Stainless Steel Single and Dual Circulation Kits

BALL VALVE Installation and Operations Maintenance Manual

Trunnion-Design Ball Valves

FLANGED END BALL VALVE

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Baumann 24000SB Barstock Control Valve

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

VALVEWORKS USA OPERATION AND SERVICE MANUAL FOR MODEL FM 2 4-1/16 GATE VALVE

QLM and QLD Series Three-port Control Valves

PBX Series Quick Fit Connector Bimetallic Steam Traps

Fire Hydrant Troubleshooting

IOM SERIES 820-E/P Electro-Pneumatic Positioner

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

James M. Pleasants Company

V47 Series Temperature Actuated Modulating Water Valves

NEWCO VALVES Newmans Inc., Newmans Valve Ltd. NEWCO/OIC Cast Valve Operation & Maintenance Manual

FT43, FT44, FT46 and FT47 Ball Float Steam Traps

TECHNICAL SERVICE MANUAL

Type and Type Pneumatic Control Valves. Type (left) and Type (right) Mounting and Operating Instructions EB 8026 EN

Machine needle shut-off nozzle type HP

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Installation Instructions S

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE.

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Drive shaft, servicing

HOPPER SHAPE KNIFE GATE VALVE

81000 Series Aluminum Gate Valve Installation and Repair Manual

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Round Housing with Side Ports

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

TYPE E Main Valve Sizes 3 /8 through 12

Instruction Manual EH /10. Putting You In Control Series. Double Ported Globe Valves

Unique DV-ST UltraPure - Manuel: for valve sizes DN8 to DN80 (¼ to 3 )

Stainless Steel Valves For the Sanitary Industries

IMPORTANT SAFETY NOTICE

STORED PRESSURE STAINLESS STEEL

Spicer Axles & Brakes ABIB-0302

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

M A N U A L

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Fisher CV500 Rotary Globe Control Valve

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Fisher 249 Caged Displacer Sensors

Chapter 7 Hydraulic System Troubleshooting

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Installation instructions

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

This kit may void factory warranty please check with manufacturer.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Select Radiators Installation Guide

system in the world. your vehicle. We pride feedback Sincerely, President

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Toroidal Conductivity Sensor

Flat Bottom Long Ram Hydraulic Jack

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Parts Replacement Manual For DODGE TORQUE-ARM Speed Reducers Straight Bore & Taper Bushed

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

MODEL G300 BRAKE BLEEDER

Repair of Hyd-ro-ac Actuators

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear

This instruction is valid for all ACD pump models shown on page 2

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

UNITS Units are designated by the unmounted pump model numbers followed by a letter indicating drive style.

Transcription:

Installation, Operation & Maintenance Manual For Modentic Two Way all Valves aution: Please read these instructions carefully and completely before installation. With the correct installation and maintenance, Modentic valves offer you a long, trouble-free service. The most important thing is to keep off the injury to the personnel and the damage to the equipment. Safety Precautions: 1. all valves are pressure equipment; therefore the appropriate safety measures have to taken into account. 2. ny alterations on the valves and the documents without prior approval from Modentic with formal documentation are not permitted and might result in the huge danger. 3. ll valves are designed for use within the limits specified herein and described on the valve body. Exceeding these specified limits is to be considered misuse and can lead to serious injuries and/or damage to the installation and environment. 4. When personnel are maintaining a valve, proper eye, head and whole body protection, and protective clothing should always be utilized. The most important thing is to keep off the injury to the personnel and the damage to the equipment. 5. ll of the valves should arrive in the open position at the installation site. 6. There is the possibility that the (dangerous) pressurized fluid or gas could be trapped in the cavity of the valve, make sure this is released safely by partly opening the valve. 7. When the valves are operated on low or elevated temperature, operating personnel must take special care to avoid injuries. 8. The valve body rating can be higher than the seat rating. Valve surface temperature may be come extremely hot or cold due to the ambient or operating conditions. Prevent any type of direct contact with the valve that may harm the workers. 9. Valves and accessories must not be used as a sole support of piping or human weight. 10. Safety accessories such as safety relief (overpressure) valves are the responsibility of the system designer. 11. It is the user/system designer s responsibility to use insulation in high temperature applications. 12. Do not disassemble actuator with pressure loaded or warranty will be invalid for inappropriate disassembling.

General: 1. Valve pressure varies under different models, sizes, working temperatures, and the materials of the main parts. Please verify the application within the limits specified herein and as described on the valve body or name plate from Modentic. 2. ny ball valve is a pressure containing part of the installation with an operational function, maintenance personnel must take this into consideration, therefore the appropriate safety measures have to be taken into account, it is necessary to wear the protective equipments and take appropriate precautions to safeguard against possible injury. 3. lways use Modentic recommended spare parts for maintenance and replacement. 4. Valve Marking: ll the marking information should be cast on the body, or on a metal plate which is spot-welded to the body. PED VLVES MRKING MRK DESRIPTION D E F G H TYPE NO. YER OF MNUFTURE MTERIL SIZE PRESSURE E. MRK TEMPERTURE TUV RHEINLND / ERLIN-RNDENURG E G X-XXX F8M PN40 XXX DN32 D F H HET NO. ST ON THE ODY ND P MD LOGO ST ON THE ODY OR XXXXXXXX 0038 ON THE NMEPLTE

PED(SEP) VLVES MRKING UNDER DN25 MRK DESRIPTION SIZE MTERIL PRESSURE HET NO. ST ON THE ODY ND P MD LOGO ST ON THE ODY OR ON THE NMEPLTE X-XXX F8M PN40 OUTSIDE THE EU OUNTRIES NON-PED VLVES MRKING MRK DESRIPTION SIZE MTERIL PRESSURE HET NO. ST ON THE ODY ND P MD LOGO ST ON THE ODY OR ON THE NMEPLTE X-XXX F8M PN40 Limitation: 1. Valves are not to be used in safely functions such as safety loops or separating incompatible fluids. 2. In-line service only, not recommended for end of line service. 3. On-off service only (not to be used for throttling). 4. Do not use for slurries or fluids containing solids that can build up in valve cavities. 5. To provide an optimum service, the valve should be operated only in its fully open or fully closed position. 6. For a single acting actuator, a normal-open actuator will go back to open position when the pressure source is gone and vice versa. 7. For a double acting actuator, the actuator will stop at end position when the pressure source is gone.

Storage: ll valves are packed in strong cardboards (plastic bags for smaller sizes) to avoid any possible damage during transportation. If the items are not for immediate use, please follow the precautions: 1. Keep the valves in complete open position. Never leave the valve in the partially open position. 2. The valves should be appropriately protected and stored against dust, dirt, mud, wet and sea water. 3. arbon steel valves have a lack oxide and the dipped finish. This nontoxic process is performed to retard rusting during storage. It is not a substitute for paint or other means of protective coating to be applied to the valve once installed. For stainless steel valves, as their natural finish, it is no need to have any additional protection once installed. Installation: 1. Valve pressure varies under different valve series, sizes, application temperatures and the material of the main parts. Please verify the application within the limits and as described on the valve body or nameplate from Modentic. 2. Prior to the installation, check the valve as well as the connecting parts to make sure they are free from dirt and burrs. nd it might be necessary to flush the valve, valve cavity and the pipes to remove the accumulated dirt and burrs. 3. Valves should be operated for at least two complete cycles before the installation to the pipe. 4. Keep the valve in full open position. 5. The ball valves are bi-directional and suitable to be installed for flow in either direction. 6. Flanged Ends a. heck companion of flanges are dimensionally compatible with the flanges on the valve body and make sure sealing surfaces are free of grease, dirt etc. b. Prepare the suitable gasket for flanges connection and put that between the connecting flanges. c. onnect the flanges with the appropriate size bolts and heavy hex nuts which confirm to comparison standard. d. Tight flange bolts as recommended by gasket manufacturer and standard. e. Following installation, execute leak and operating tests. 7. Threaded Ends a. heck specification of threads on mating pipe. b. pply joint compound to the male end of joint only. c. Use suitable sealing material.

d. Use wrench and apply force on the hexagon end of the valve only. pply force to other area of valve may seriously damage the valve. e. Following installation, carry out leak and operating tests. 8. Socket Weld Ends a. It should be tightly closed before welding or installation to prevent damage to the seating surfaces and stem caused by thermal expansion during the socket welding process. b. Prior to welding, ends caps must be removed to prevent seat or gasket from being damaged by the overheating while welding. c. Weld the end caps on the pipe stub. e careful for the welded part, it may be super heat for minutes before completely cool down. d. Prior to assembly the body back to the end caps, clean both end caps carefully. ny particle left could damage the ball surface or the valve port which would lead to leakage. e. Tightened the body bolts evenly, check the valve for proper operation. f. Following installation, perform leak and operating tests. 9. Install the valve in such a way that extensive stresses in any direction on the valve are avoided. 10. lways do leak test to the system before using. Operation: 1. Modentic ball valves of this series are 1/4 turn-operated valve, if the valve lever or handle is turned according to 90 degrees clockwise, the valve will be fully closed. 2. Note that the valve handle also serves as a ball orifice position indicator. If the valve handle is parallel to the pipe, the valve is opened. While a perpendicular handle indicates a closed valve. 3. To provide an optimum service life, the valve should be operated only in its fully open or in its fully close position. 4. Extending the lever or handle from the ball valve is to be considered misuse and can cause serious injuries and damages to the valve and equipment. 5. When the valves are operated on low or elevated temperature operating, personnel must take special care to avoid injuries. 6. The valve body rating can be higher than the seat rating. Valve surface temperature may become extremely hot or cold due to the ambient or operating conditions. Prevent any type of direct contact with the valve that may harm the workers. 7. For lever operation, follow the indicator on the top side of the lever to open or close the valve. 8. For gearbox operation, follow the indicator on the handle to open or close the valve. Note that the gearbox is chosen in according to the torque, do not replace the gearbox with different specification.

Maintenance: 1. efore making the maintenance, always advise the maintenance personnel that the proper eye, head and whole body protection always be utilized. 2. efore making the maintenance, always make sure the pressure is released safely by partly opening the valve. 3. Prior to the maintenance, flush the valves and the pipe lines attached and make sure that no (dangerous) residues are left. Ensure that the installation, together with pressure containing parts is depressurized and secured. 4. There is a possibility that a dangerous pressurized fluid or gas is trapped in the valve cavity, release this safely by partly opening the ball valve. 5. It is impossible to predict the frequency of the maintenance interval. The maintenance interval is dependant upon several factors which are not foreseeable by the manufacturer. 6. It is important to recognize stem and seat leakage and this is not to be left unattended. 7. For gearbox operation, there is no maintenance required for the gearbox under normal operating conditions. If it is necessary to temporarily remove the gearbox for overhaul, the gearbox baseplate may be removed. ut the baseplate must be sealed by silicone sealant for re-assembly unless fitted with O-rings. User s note: 1. End-users have the responsibility to check the wall thickness in regular intervals due to wear/ tear/ corrosion of the fluid in order to ensure the wall thickness is not below the minimum safety thickness allowed in the standard. 2. The most important thing is to keep off the injury to the personal and the damage to the equipment.