Work Verification of the Energy Steam Boiler Evaporator in the Power Plant Kostolac B

Similar documents
1 DESCRIPTION OF THE APPLIANCE

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

5.2. Vaporizers - Types and Usage

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Thermodynamical aspects of the passage to hybrid nuclear power plants

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

16. Heat Pipes in Electronics Cooling (2)

Basics of Steam Generation

Waste Heat Recovery through Air Conditioning System

The soot and scale problems

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

OROT RABIN POWER STATION UNITS x 350 MW

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

Design of heat exchangers

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Heat Exchangers in Boilers

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

CASL-U

Skoda Supercritical Steam Turbine 660 MW

The Effect of Mass Flow Rate on the Enhanced Heat Transfer Charactristics in A Corrugated Plate Type Heat Exchanger

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

How To Calculate The Performance Of A Refrigerator And Heat Pump

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

2nd IEA Oxyfuel Combustion Conference

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

HYBRID COMBINED CYCLE POWER PLANT

Babcock & Wilcox Company Supercritical (Once Through) Boiler Technology

Webpage: Volume 3, Issue IV, April 2015 ISSN

Petroleum Refinery Hydrogen Production Unit: Exergy and Production Cost Evaluation

WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS

Efficiency on a large scale CFB Steam Boilers

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

By K.K.Parthiban / Boiler specialist / Venus Energy Audit System

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Originators of the Flexible Water Tube design

Committed to make a better world

BENSON Boilers for Maximum Cost-Effectiveness in Power Plants

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

New Trends in the Field of Automobile Air Conditioning

Mathematical Modelling and Design of an Advanced Once-Through Heat Recovery Steam Generator

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

Thermal efficiency of pulverized fuel boiler

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Experimental Study on Super-heated Steam Drying of Lignite

APPLICATIONS OF AN HEAT PIPE HEAT EXCHANGER IN THE RECOVERY OF WASTE HEAT FROM URBAN WASTEWATERS

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

C. starting positive displacement pumps with the discharge valve closed.

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

CFD Analysis Of Multi-Phase Flow And Its Measurements

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Steam/Water Circulation Design

UNIT 2 REFRIGERATION CYCLE

FEDSM Flow Boiling Heat Transfer Enhancement in Subcooled and Saturated Refrigerants in Minichannel Heat Sinks

Condensing Boiler Efficiency

Correlations for Convective Heat Transfer

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

How To Power A Power Plant With Waste Heat

MODERN STEAM GENERATORS

Enhancement of heat transfer of solar air heater roughened with circular transverse RIB

Building Energy Systems. - HVAC: Heating, Distribution -

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Combined CFD, material and system level analyses Case Naantali power plant

Steam Generation Efficiency Module Blowdown Losses Section

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Power consumption (kw)

Engine Heat Transfer. Engine Heat Transfer

Cooking at the Speed of light!

Online Infrared Flue Gas Analyzer Gasboard 3000

International journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

A basic introduction to steam

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Natural Convection. Buoyancy force

GT ANALYSIS OF A MICROGASTURBINE FED BY NATURAL GAS AND SYNTHESIS GAS: MGT TEST BENCH AND COMBUSTOR CFD ANALYSIS

Performance Test of Solar Assisted Solid Desiccant Dryer

Stove-boiler for solid fuels KW Directions for use and assembling

Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations

Heat pipes and Thermosyphons. Heat pipes and Thermosyphons. Heat pipes and Thermosyphons. Heat pipes. Heat pipes. Heat pipes

ENGINEERING INFORMATION Hot water and steam service

Increasing Power Plant efficiency for safe wet stack Operation

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

High-efficient gas boiler CompactGas

Boiler efficiency measurement. Department of Energy Engineering

Transcription:

Goran Stupar Teaching Assistant Titoslav Živanović Professor Dragan Tucaković Professor Miloš Banjac Professor Work Verification of the Energy Steam Boiler Evaporator in the Power Plant Kostolac B Within Electric Power Utility of Serbia 1991, a thermal power plant Kostolac B, power 2 350 MW, started. Based on the examination of steam boiler pipe system, it is confirmed that it is in a bad shape. Its most jeopardized parts are evaporating heating surfaces. Considering that there are areas within the evaporator that suffered more damage, wherefore the steam boiler is out of production, it is necessary to settle the reasons for those damages. In order to locate the jeopardized areas of the evaporator, we carried out a detailed hydraulic calculation. A thermal calculation of steam boiler was also carried out, considering that the evaporator is also located in the convective heating surfaces part. By settling the most jeopardized evaporator locations a horizontal part of support tubes, it was enabled to make certain reconstructions during the capital repair, in regard of changing their inclination angle, which would provide safer work of the evaporator, and steam boiler as a whole. Keywords: steam boiler, evaporator, hydraulic calculation, thermal calculation, inclination angle of tubes. 1. INTRODUCTION Within the thermal power plant Kostolac B there are two steam boilers made for combustion of lignite with a lower heating value of 7326.9 kj/kg. The basic characteristics of a steam boiler are as follows: Main steam mass flow rate, D = 277.8 kg/s; Main steam pressure, p s = 18.6 MPa; Main steam temperature, t s = 540 ºC; Reheated steam mass flow rate, D r = 248.8 kg/s; Reheated steam pressure, p rs = 4.375 MPa; Reheated steam temperature, t rs = 540 ºC; Feed water temperature, t nv = 255 ºC A simplified steam boiler disposition is shown in Figure 1. Flue gases made by coal combustion in the furnace (4) are streaming over the third superheater stage (6), the second reheater stage (7), the second superheater stage (8), the first reheater stage (9) and economizer (1), and then turn into the sheet duct (10), in the outlet of which two air preheaters are situated, after which flue gases are released into the atmosphere. Feed water is guided into the economizer (1). After heating, water gets into the mixing box in which it is mixed with water from the separator (2). This mixture arrives into the circulation pump, which then suppresses it into the ring header (3) that supplies furnace screen (4) having the form of a membrane wall. One part of the tube screen on the furnace outlet is distributed into support tubes (11,12) on which the superheater and reheater stages and economizer are hanged. The convective gas channel is also screened with tubes. Received: October 2011, Accepted: December 2011 Correspondence to: Goran Stupar, Kraljice Marije 16, 11120 Belgrade 35, Serbia E-mail: gstupar@mas.bg.ac.rs 1 Economizer; 2 Separator; 3 Lower furnace screen headers; 4 Furnace; 5 First superheater stage; 6 Third (output) superheater stage; 7 Second (output) reheater stage; 8 Second superheater stage; 9 First reheater stage; 10 Sheet duct; 11 Horizontal part of support tubes; 12 Vertical part of support tubes duct Figure. 1. Disposition of the steam boiler in TP Kostolac B, Belgrade. All rights reserved FME Transactions (2012) 40, 31-36 31

The mixture of water and steam from furnace screen tubes, support tubes and convective channel screen tubes is lead, over the system of headers, which are located on the top of the convective channel, into the separator (2) where the phase separation is conducted, so water, after mixing with feed water, enters in the described circle, while steam is lead for superheating. Hydraulic calculations for the evaporator of the examined boiler were made for two work cases: for the designed conditions and for the existing state. Calculation for the designed conditions is based on thermal calculation made for parameters adopted by the boiler manufacturer and for garant fuel. Under the existing conditions, the case is considered in which the heat load disposition by furnace height is changed in relation to the designed, that is, when the highest temperature zone is located in the upper furnace part (risen flame). With that, calculations for real conditions are made for improved quality fuel, with a lower heating value of 8373.6 kj/kg. Thermal and hydraulic steam boiler calculations were based on the Normative method shown in [1-3] which gave the best results for the boilers in Serbia. More refined models of two-phase flow, applicable to the steam boiler evaporating tubes and based on the multi-fluid models of two-phase flow are presented for an example in [4,5]. Experimental data and corresponding correlations of heat transfer coefficient, friction pressure loss coefficient and critical heat flux in smooth evaporating tubes of steam boilers are presented in [6,7]. 2. TECHNICAL DESCRIPTION OF THE EVAPORATOR From the ring header, Ø273 28 mm dimensions, water is lead via connecting tubes into inlet headers of the front, rear, left and right evaporator wall. Depending on the inlet header size, each is fed with one, two or tree connecting tubes in which the diaphragms are placed, and whose geometry is given by the manufacturer. The boiler evaporator is a very complex construction and is divided into panels that function as inlet headers. The front and rear evaporator wall have seven pairs of headers each from which tubes are exiting, forming the adequate panels, while side walls are made of eight headers from which tubes exit, forming eight adequate panels (Fig. 2). Within the front and rear furnace wall panel, there are tubes used as support tubes, and pipes that make the front and rear convective channel screen wall. Besides, some tubes of both kinds are bent around different openings. Sidewall tubes screen the furnace and convective gas channel and there are two kinds: straight, and bent around the opening. Therefore, the evaporator is made of a large number of tubes that are geometrically and hydraulically different. Because of that, the panels shown are divided into an appropriate number of elements consisting of tubes with the same geometrical characteristics. The front and rear walls are divided into 41 elements each, and left and right wall into 21 elements each. Figure 2. Division of evaporator riser tubes: (a) front and rear wall of the evaporator and (b) left and right side wall of the evaporator Every element of the evaporator is divided vertically into seven stages depending on heat load distribution, which is gained from thermal calculation of steam boiler and the appropriate geometry (Fig. 3). 3. HYDRAULIC CALCULATION OF THE EVAPORATOR The principle of the hydraulic calculation of the evaporator is based on definition of the flow rate of every element for the given and adopted conditions (geometrical characteristics and heat load distribution) in that manner that in each of them the pressure drop between the ring header and the separator is the same. The procedure of the hydraulic calculation [2,3] consists of determining the hydraulic characteristics of complex elements of the circulation loops with a graphoanalytical method. In order to solve complex hydraulic calculation procedures, the own code was developed using the iteration method. End results of the hydraulic calculation for the evaporator are shown in Table 1. Results given by boiler designer are given in column 4, while the results of calculation made by the Faculty of Mechanical Engineering in Belgrade, and relating to the burning of garant fuel and nominal load, are shown in column 5. Results for the existing work conditions of the boiler with improved fuel and risen flame are shown in columns 6, 7 and 8, for 3 different boiler loads. 32 VOL. 40, No 1, 2012 FME Transactions

4. CALCULATION RESULTS ANALYSIS 1 Furnace funnel; 2 Primary furnace zone; 3 Secondary furnace zone; 4 First superheater stage; 5 Furnace recirculation zone; 6 Third superheater stage; 7 Second reheater stage; 8 Second superheater stage; 9 First reheater stage; 10 Economizer; 11 Support tubes; 12 Guide chamber; 13 Outlet tube screen Figure 3. Distribution of riser part of the evaporator to stages in accordance with heat loads Based on the results shown for hydraulic calculation, it is found that the flow rate value of circulation water is different from that calculated in the same steam boiler working conditions. Water flow rate at the steam separator outlet (Table 1, column 5) is around 20 % greater than the designed one (Table 1, column 4) which happens during the boiler work. The lower amount of heat given to the evaporator resulted in an increase of circulation number and therefore the increase of water amount in the separator. In order to bring the flow down to the designed values, it would be most efficient to set a circulation pump at the appropriate number of rotations and a possibility of its regulation. It is possible, as an alternative, to install the appropriate regulating valve in the downcomer part of the evaporator. Circulation water flow rate through the evaporator is similar for each furnace working conditions and the steam boiler load. If the boiler is working with a risen flame, heat given to the evaporator is less, which brings to the decreased steam quality on its outlet. Decrease of the boiler load also causes the decrease of the steam quality on the evaporator outlet for two reasons. First, a lower heat quantity is given to evaporator, and second, there is the increase of the latent heat of evaporation at lower pressures, because the boiler is working with a sliding pressure. After the shown calculation, all the relevant parameters necessary for the security check of an evaporator, defined by these conditions, are: cavitation effect, absence of circulation halt and direction change, stability of hydraulic characteristics, absence of flow pulsation and normal temperature regime of heating tubes. All of these conditions have been obtained, except the temperature regime of heating tubes for support tubes in a part of the third superheater stage. Table 1. Results of hydraulic calculation of the evaporator Name Nomenclature Units Designer s results Lower heating value of fuel [kj/kg] 7326.9 8373.6 Boiler load [%] Designed conditions Risen flame 100 100 100 85 70 1 2 3 4 5 6 7 8 Circulation water flow rate through evaporator Water flow rate at separator outlet Steam flow rate at separator outlet D c kg/s 360.000 416.673 405.909 404.457 415.698 D w kg/s 88.000 159.481 166.942 213.192 267.236 D s kg/s 272.000 257.192 238.967 191.265 148.462 Steam quality in separator x kg/kg 0.756 0.617 0.589 0.473 0.357 Circulation number κ 1.324 1.621 1.699 2.114 2.801 Pressure in separator p s bar 202.3 202.3 202.3 183.8 150.0 Temperature in separator t s ºC 367 367 367 359 342 Absorbed heat load in evaporator Q i kw 256,461 240,653 210,699 191,587 171,399 FME Transactions VOL. 40, No 1, 2012 33

Namely, during a certain combination of regime parameters (pressure, mass velocity, heat flux, steam quantity and pipe geometry) coefficient of heat transfer during the streaming of two-phase flow is quickly reduced due to the contact interruption between the inner tube wall and liquid faze, when there is a fast increase of wall temperature. Under high void conditions, the liquid film depletes on the evaporating tube inner wall, with a possibility of wall dry-out and occurrence of critical heat transfer conditions. The basic parameter of the critical heat transfer is steam quality at the spot of appearance of a wall dry-out and its critical steam quality (CSQ). The methodology for the calculation of the steam quality, as the appropriate increase in the inner wall temperature, is shown in [8] in more details. support tubes. Namely, with reducing the boiler load, the pressure in the evaporator is also reduced, which leads to the increase of the critical steam quality in the vertical tubes, but reduces the difference of the critical steam quality between the upper and the lower stream of the inclined tubes. Based on the shown diagrams, it is clear that regardless of the boiler load, there is always a danger of stratification in the inclined part of the support tubes, which causes the difference in cooling on the tube volume. Diagrams also show temperature increase values of the inner ( t wi ) and outer ( t wo ) surface of the tube wall, based on which we can conclude that tube wall temperature increases with load (pressure) reduction at the spot of appearance of a wall dry-out, so that the boiler load of 70 % and appropriate pressure can be in a danger area. 5. CONCLUSION Figure 4. Tube geometry of evaporator element with greatest heat load For this analysis, we have chosen support tubes with the largest heat load, which are a part of the element no. 3 of the rear wall furnace (Fig. 4). The change of the critical steam quality (CSQ), for the vertical (inclination angle of 90º) and for the upper (US) and lower (LS) stream of the inclined tubes, of the chosen evaporator element for three different boiler loads during real working conditions, is shown in Fig. 5. Besides, steam quality values on the inlet and outlet of the fifth and sixth stage can be found in the diagram, where it s visible that the critical heat transfer during the boiler load of 70 % takes place in the horizontal part of the Based on the analysis results of the hydraulic calculation of the evaporator of the given steam boiler, we can conclude the next: Total evaporator flow rate, for the same conditions, is 20 % greater than the flow rate predicted by the designer. Because of that, the circulation number in the evaporator is 1.62, compared to the designed, being 1.32, which resulted in a greater amount of water in the separator. Boiler works using the fuel of improved quality with a risen flame in furnace, which is suitable to the existing conditions, brings changes to the evaporator s working conditions, in such manner that the critical heat transfer conditions are worsen. That happens more often with reduced boiler load. Variable boiler work regimes lead to deterioration of the listed conditions, and to variable heat loads and tensions in tube material, which results in its fatigue and eventually its damage. Critical heat transfer conditions are more dangerous for horizontal tubes, which have a temperature difference between the upper and lower stream. Variable regimes, in this case, have even greater effect on fatigue of the materials than they do on vertical tubes. For the given boiler, this is presented in the inclined area of support tubes at the furnace outlet, and on the inlet of the third superheater stage, respectively. This was confirmed in practice most of the time, boiler s break down was due to damage caused by thermal changes on the support tubes in the considered area. Increase of inclination improves the conditions of the tubes, so it is recommended to increase the inclination angle for this part of tubes. Besides, it would be good to use a material of better quality for this part of support tubes. ACKNOWLEDGMENT This work was supported by the Republic of Serbia Ministry of Education and Science (project: Increase in energy and ecology efficiency of processes in pulverized coal-fired furnace and optimization of utility steam boiler air preheater by using in-house developed software tools, No. TR-33018). 34 VOL. 40, No 1, 2012 FME Transactions

REFERENCES [1] Brkić, Lj., Živanović, T. and Tucaković, D.: Thermal Calculation of Steam Boilers, Faculty of Mechanical Engineering,, Belgrade, 2007, (in Serbian). [2] Brkić, Lj., Živanović, T. and Tucaković, D.: Hydrodynamic Calculation of Steam Boilers,, University of Belgrade, Belgrade, 2007, (in Serbian). [3] Baldina, O.M., Lokschin, V.A., Peterson, D.F., Semenovker, I.E. and Schvarc, A.L.: Hydraulic Calculation of Boiler Plants The Normative Method, Energia, Moscow, 1978, (in Russian). [4] Tucakovic, D.R., Stevanovic, V.D., Zivanovic, T., Jovovic, A. and Ivanović, V.B.: Thermal-hydraulic analysis of a steam boiler with rifled evaporating tubes, Applied Thermal Engineering, Vol. 27, No. 2-3, pp. 509-519, 2007. [5] Delhaye, J.M., Giot, M. and Riethmuller, M.L.: Thermohydraulics of Two-Phase Systems for Industrial Design and Nuclear Engineering, Hemisphere, Washington, 1981. [6] Stevanovic, V. and Studovic, M.: A simple model for vertical annular and horizontal stratified twophase flows with liquid entrainment and phase transitions: one-dimensional steady state conditions, Nuclear Engineering and Design, Vol. 154, No. 3, pp. 357-379, 1995. [7] Ponnappan, R., Ramalingam, M.L., Johnson, J.E. and Mahefkey, E.T.: Evaporator critical heat flux in the double-wall artery heat pipe, Experimental Thermal and Fluid Science, Vol. 2, No. 4, pp. 450-464, 1989. [8] Kastner, W., Kefer, V., Koehler, W. and Kraetzer, W.: Heat Transfer and Pressure Loss in Tubes Heated from One Side, as well as in Inclined and Rifled Tubes, Siemens Aktiengesellschaft Unternehmensbereich KWU, Erlangen, 1988, (in German). ПРОВЕРА СИГУРНОСТИ РАДА ИСПАРИВАЧА ЕНЕРГЕТСКОГ ПАРНОГ КОТЛА У ТЕ КОСТОЛАЦ Б Горан Ступар, Титослав Живановић, Драган Туцаковић, Милош Бањац p pressure; q Heat flux; t s Saturation temperature; t wi Inner wall temperature; t wo Outer wall temperature; m Mass velocity Figure 5. Change of the critical steam quality (CSQ) based on the inclination angle of tubes and an appropriate boiler load: (a) results for 100 % boiler load, (b) results for 85 % boiler load and (c) results for 70 % boiler load У оквиру Електропривреде Србије 1991. године пуштена је у рад Термоелектрана Костолац Б снаге 2 350 МW. На основу досадашњих испитивања цевног система парног котла утврђено је да се он налази у лошем стању. Његови најугроженији делови су испаривачке грејне површине. С обзиром да постоје области у испаривачу које су се чешће оштећивале, због чега је парни котао испадао из погона, неопходно је утврдити разлоге због којих је долазило до тих оштећења. Да би се лоцирала угрожена подручја испаривача, спроведен је детаљан хидраулички прорачун. Такође је извршен термички FME Transactions VOL. 40, No 1, 2012 35

прорачун парног котла у целини, с обзиром да се испаривач налази и у зони конвективних грејних површина. Утврђивањем најугроженије локације испаривача хоризонтални део носећих цеви, омогућено је да се при капиталном ремонту изврше одређене реконструкције у смислу промене њиховог угла нагиба, што би у крајњем обезбедило сигурнији рад, како испаривача тако и котла у целини. 36 VOL. 40, No 1, 2012 FME Transactions