9 Control Equipment. Control Unit System Series ConSig 8040

Similar documents
9 Control Equipment. Control Button Series 8082

Terminal Boxes Series 8146

Control and Distribution Boxes made of Stainless Steel Series 8150

Control Stations Made of Polyester Resin Series 8146

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire with LED Series EXLUX 6402/2

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices CES 63 A Series 8579

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Solenoid Valve Island Type 3965

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

8146/5 Series Breaker Panelboards

A good connection. International approvals.

7 Lighting Technology

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

ConSig 8040 Series CONTROLS Features:

2.12. page Products for Explosion hazardous Environment

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. Dimensions

Flameproof Audible Signal 115 db (A) Series YA90

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Technical Data. Dimensions

STB Series Enclosures

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical data sheet TDS0070

Terminal Box. Specifications TNCN

type V46, solenoid or pneumatic operated

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Cable Plug acc. to DIN EN , Form A

Electric Rotary Actuator - On/Off or programmable control actuator

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

TEIP11 I/P signal converter for standard signals. Measurement made easy

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Mini USB and USB 2.0-IP67 Connector System

Microcor Wireless Transmitter (MWT)

Explosion proof enclosures

ASSEMBLED SOCKET-COMBINATIONS

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Guide to enclosures for potentially explosive atmospheres

HARTING Ethernet Cabling 8-poles Overview

Digital inductive conductivity transmitter

Technical Information RIA14

3/2-way Solenoid Valve, direct-acting, NC or NO

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Solenoid Valve Type 3962

Floodlight Range Installation Guide

IEC Connectors. Introduction

System 8. ü ( System 8

Scraper Passage Indicator. Electrical Indicator. Features

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Redundancy Module QUINT-DIODE/40

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES TO 20 (4) A 250 V AC

IECEx Certificate of Conformity

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Control and Signaling Units

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Quick Connect Boxes Inside Gloveboxes

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Mureva Assembly surface mounted wiring devices

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Wolflite Safety Handlamp H-251E

Safety detection solutions

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

2/2 and 3/2 Solenoid Control Valves

Switches and Indicators. Swisstac

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Common Features of Electromechanical Switches

Switches & Pilot Devices

Fluxa Area floodlights for high pressure discharge lamps and LEDs

400 Series Buccaneer BUCCANEER POWER. bulgin

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

SITRANS F flowmeters SITRANS F M

Transcription:

9 Control Equipment Control Unit System 01719E00 The enclosure makes it possible to assemble different control units in a clear layout. Due to the fact that a wide range of control devices is available this enclosure covers a broad field of applications. Explosion protection to CENELEC IEC NEC For use in Zone 1 and Zone 2 Zone 21 and Zone 22 Standard and customized units 3 sizes available Enclosures in glass fibre reinforced polyester resin Up to 3 insertion points available per individual unit Individual units can be combined into larger units Options: flanges in brass or moulded plastic metal plates where metal cable entries are used equipment identification plate can be attached Contact blocks 8082 and 8208 with SIL certificates On request with contact block 8208 for extra low currents, with open-circuit and short-circuit monitoring 9/1Zones 1 & 2, 21 & 22

Control Unit System 9 Pushbutton 8040/1180.001+0/rt/I/gn-060 0,370 05506E00 Mushroom button d 38 mm black 8040/1180.003+I/sw-060 0,400 05507E00 Mushroom stayput d 38 mm 8040/1180.010-060 0,400 05600E00 08793E00 05511E00 d 55 mm 8040/1180.015-060 0,400 05600E00 08793E00 d 38 mm 8040/1180.010-762 0,410 05600E00 09258E00 Mushroom stayput key release d 38 mm 8040/1180.009-060 0,450 08005E00 Key-operated switch 05510E00 2 switching key withdrawable in 0 + I 8040/1180.008+2r-060 0,450 08750E00 05509E00 3 switching key withdrawable in I + 0 + II 08752E00 8040/1180.008+3rr-062 0,450 Twin pushbutton 8040/1180.023+I/gn/0/rt-060 0,400 05516E00 08007E00 Illuminated pushbutton spring return, yellow,, 08015E00 8040/1180.735+al-737 0,400 05512E00 9/2

9 Control Unit System Indicating lamp Diode indicating lamp 8040/1180.054+al-064 0,125 05512E00, yellow,, 08006E00 Selector switch with switch element 8082 2 switching 8040/1180.726+2r-060 0,420 08003E00 05729E00 3 switching 8040/1180.726+3rr-062 0,420 08753E00 08006E00 Control switch with switch 8008 and large actuator with large actuator > Contact arrangement (see switch 8008) 8040/1180.731+ -160+ 0,440 05515E00 Control switch with switch 8008 and small actuator, padlockable with small actuator padlockable in 1 position > Contact arrngement (switch 8008) 8040/1180.734+ -160+ 0,420 05514E00 Control switch with switch 8008 and small actuator, with small actuator > Contact arrngement (switch 8008) 8040/1180.732+ -160+ 0,420 05513E00 Twin pushbutton 8040/1280.001+I/gn-060 0,460 05519E00 Diode indicating lamp and pushbutton, yellow,, 8040/1280.054+al-064 0,460 05520E00 9/3

Control Unit System 9 Diode indicating lamp and twin pushbutton, yellow,, 8040/1280.054+al-064.023+I/gn/0/rt 0,540 05521E00 Ammeter 8405 Ammeter > Measurement range, see ammeter 8405 > Measuring methode (direct = d or converter = W) 8040/1280.740-086+ 0,490 05525E00 Tripple pushbutton 8040/1380.001+I/gn-060.001+II/gn-060 0,580 05522E00 05598E00 2 pushbuttons with indicating lamp, yellow,, 8040/1380.054+al-064.001+I/gn-060 0,640 05524E00 08012E00 Twin pushbutton with mushroom stayput key release and indicating lamp, yellow,, 8040/1380.054+al-064.023+I/gn/0/rt-060.009+MS1-060 0,750 05523E00 08012E00 9/4

9 Control Unit System Ammeter 8405 and control switch 8008, 2 pole Ammeter > Measurement range, see ammeter 8405 > Measuring methode (direct = d or converter = W) 8040/1380.740-086+.731+ -160+ 0,780 05732E00 Control switch 8008, 4 pole with large actuator 8040/2380.731+ -161+. 0,770 05707E00 Control switch 8008, 4 pole and ammeter Control switch 8008 4 pole, with large rotary actuator, ammeter 8405 Ammeter > Measurement range, see ammeter 8405 > Measuring methode (direct = d or converter = W) 8040/2380.740-086+.731+ -161+. 0,930 05708E00 Control switch 8008, 4 pole and indicating lamp Control switch 8008 4 pole with large rotary actuator 8040/2380.054+al-064.731+ -161+. 0,800 Indicating lamp 8010 >, yellow,, 05709E00 Technical Data Explosion protection Gas explosion protection E II 2 G EEx edmq ia / ib [ia / ib] IIC T6 Dust explosion protection E II 2 D IP 66 T80 C, T95 C Certificates Gas explosion protection PTB 01 ATEX 1105 Dust explosion protection LCIE 02 ATEX 6238 Other certificates Rated voltage Rated working current SIMTARS (Australia), CSA (Canada), UL (USA), VNIIEF (Russia), UL do Brasil (Brazil) max. 690 V, AC dependent on components used Ambient temperature - 20 C... + 40 C - 50 C... + 60 C on request 9/5

Control Unit System 9 Technical Data Cable entries Standard: 1 x M 25 x 1.5; cable gland 8161; side below (D); directly mounted into enclosure wall Special: in side C (top) and/or side D (below); 1 x M 20 x 1.5; 1 x M 25 x 1.5; metal cable glands are possible; mounting of metal cable glands in metal flange or via metal adapter plate Flanges Degree of protection IP 66 Material Housing Gaskets Cover fixing In standard design the enclosures are without flanges; On request they can be fitted with flanges on sides C and D. Flanges are available in: polyester resin or in brass, powder-coated, dark grey similar to RAL 7024 Polyester resin (glass fibre-reinforced) PU foam M 4, cheese head screws, imprescriptible, stainless steel Dimension drawings (all dimensions in mm) - subject to alterations 04582E00 04581E00 ConSig 8040/11 ConSig 8040/12 ConSig 8040/13 04580E00 04584E00 a [mm] min. max. M 20 25 31 M 25 27 33 Additional dimensions for cable glands Series 8161 04579E00 04583E00 04585E00 Flange b [mm] Brass 16 Plastic 16 ConSig 8040/23 ConSig 8040/11 and ConSig 8040/12 combination Additional dimensions for flanges We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be conside binding. 9/6