Series 95 Switches. UL File No. E101598

Similar documents
SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications

Switches ELECTROSWITCH. For Industrial Applications I.3

Circuit Breakers. NRC Series. NRC Series

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

AZ420 MINIATURE GENERAL PURPOSE RELAY

THE ADVANTAGES ARE YOURS

Tmax MCCBs. Molded case circuit breakers. Tmax

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Panel Meters and Controllers Modular Panel Meter Type EDM 35

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.


Solid-State Timer H3G

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

C ole s quality Open Frame Instrument Rotary Switch provides low

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

HM-W536 Install Guide

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Type MG-6 Multi-Contact Auxiliary Relay

Quickie Rhapsody Service Manual

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

HMI display Installation Guide

Z-TRAUQ INC. Tel.: (450) Fax: (450)

Color Mark Sensor with Red or Green LED E3S-VS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

SECTION LOW VOLTAGE LIGHTING CONTROLS

Diesel Engine Driven Generators Page 1 of 6

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Generator DoCKInG StatIonS

THERMAL MANAGEMENT SOLUTIONS

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Modular I/O System Analog and Digital Interface Modules

A Series 1-4 Pole Rotary Switches

Manual Switches Series 2 Pushbutton Switches and Indicators

EDS / EFS Series Control Stations

What is a multimeter?

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

CITY OF LOS ANGELES CALIFORNIA

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Distribution Dry Type Transformers

E-PDD Duct Smoke Detector Installation Sheet

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

INSTALLATION INSTRUCTIONS

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

FIREDEX Conventional Fire Panels

TSn SERIES Surge Protective Device

8146/5 Series Breaker Panelboards

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Product Guide. Low voltage grounding system. Answers for industry.

Type SA-1 Generator Differential Relay

Model Number Structure

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

General Informations 2 Technical data 3 Basic designs 4-8

Model Number Structure

TrueAlarm Fire Alarm Systems

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

400 Series Buccaneer BUCCANEER POWER. bulgin

2S-Series Sub-Miniature Toggle Switches

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Universal MATE-N-LOK Connectors

12-Volt Negative Ground Installation Instructions

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

MCR1900 Media Converter 19-Slot Chassis

SX460. Generator Automatic Voltage Regulator Operation Manual

Companion Service Guide

PDS-750-TR Touring Power Supply Operator s Manual

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

General Purpose Relays Types K, R, N, and C

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Advantium 2 Plus Alarm

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

1000 Series Miniature Slide Switches

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Model 201 Wiegand Touchpad Reader Installation Guide

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Solid State Timers Type F

Transcription:

Series 95 Switches UL File No. E101598

INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the most demanding requirements of the industrial control and power applications. These switches are 600V AC rated and are recognized by Underwriters Laboratories in the United States and Canada. Some of the typical standard applications for the Series 95 are: Circuit-breaker control Motor control Voltmeter Selector and Transfer Ammeter Selector and Transfer Synchroscope Control Control Selector Switch Applications The Series 95 switches have the following standard features: Standard 3-hole Mounting #8-3 screw terminals Nema class A Insulating materials (105 0 C ) Silver contact surfaces for long reliable life Double-sided, double-wiping, knife-type rotary contacts Special Features for Circuit Breaker Control switches include: Mechanical red/green target Slip contact for alarm and indicator circuits Pull-to-Lock mechanism to return the switch handle to normal (vertical) position Selection of Lighted Escutcheon plates Special features for Meter Control switches include: Make-Before-Break (shorting contacts for ammeter control) Common-input Tap-Switch arrangement whereby the meter may be sequentially connected to several lines using the same switching deck Positive positioning detent mechanism Pre-wired jumpers Special features for synchroscope applications include: Removable Oval Handles Key lockable arrangements The following details the most common applications, contact arrangements and escutcheon plate markings. For combination of contact arrangements, handles, escutcheon plate marking and special features not shown, contact the factory for availability.

INSTRUMENT AND CONTRC ONTROL OL INSTRUMENT AND CONTROL ES.4.13.63 TYP D STOP SCREWS SUPPLIED TO LIMIT ROTATION AS DESIRED.91.5 3.5 DIA.. DIA. 1.00.81 OVAL HANDLE 01.9 MAX PANEL TYPICAL SCREWS 8-3 x 1/4 BD, HD SUPPLIED DEPTH BEHIND PANEL NUMBER OF DECKS DEPTH INCHES D 1.4.9 3 3.6 4 4.3 5 4.8 6 5.4 7 6. 8 6.6 9 7.4 10 8.0 Slip Contact - add 1.5 Pull - to- lock- Add 1 (these are approximate dimensions) UL File No. E101598 INTERRUPTING RATING 0A-10 VAC 15A-40VAC 6A-600VAC 3A-15VDC 1A-50VDC MAKE ONLY RATINGS: 75A- 10 VAC 37.5-40VAC 75A-4-15VDC 37.5A-50VDC OPEN CONTINUOUS RATING - 30A-600V DIELECTRIC STRENGTH - 00VRMS LETTER APPEARING AFTER MODEL NO i.e. 95401C.00.00.00.88 1.88.5 PISTOL GRIP D KNURLED C OVAL B 1.96.60 0.6 DIA. 3.13.5 OVAL - REMOVABLE E KEY LOCK T - HANDLE RH

INSTRUMENT AND CONTRC ONTROL OL APPLICATION ROTARY ES FOR INSTRUMENT CONTROL ESCUTCHEON Wire, Single Phase or D C Double Pole / Single Pole Throw Cat. No. 95401C Depth behind panel.40 ON 9510D - V14 4 Phase, Two Phase or Two separated D C circuits Double Pole / Double Throw Cat. No. 9540C Depth behind panel.40 1 9510C - 3V14 3 Phase, Phase to neutral Double Pole / Triple Throw Cat. No. 95403C 1 3 9510C - 4V15 3 Phase, Phase to Phase Double Pole / Triple Throw Cat. No. 95404C -3 1-3-1 9510C-4V1 3 Phase, Phase to Phase and Phase to neutral Double Pole / Six Throw Cat. No. 95405C 6 Wire, Two 3 Phase circuit, Phase to Phase Double Pole / Six Throw Cat. No. 95406C 1-1 -3 3-1 3 9510E -7V4 3-1 1- - 3-3 1-3 -1 9510E - 8V33 3 Consult Factory for non-standard Escutcheon Plates

INSTRUMENT AND CONTRC ONTROL OL ROTARY ES FOR INSTRUMENT CONTROL APPLICATION ESCUTCHEON 3 Phase, Two current Transformers Cat. No. 95407C 1 3 9510C- 3A10A 3 Phase, Two current Transformers Cat. No. 95408C 1 3 9510C - 4A13 3 Phase, Three current Transformers Cat. No. 95409C 1 3 9510C - 3A10A 3 Phase, Three current Transformers Cat. No. 95410C 1 3 9510C - 4A13 3 Phase, Phase to Phase and Phase to neutral Double Pole Six Throw Cat. No. 95411C (NO ) 1 3 9510A - 3A10 1 3 Cat. No. 9541C (WITH ) Depth behind panel 5.40 9510C - 5A16 Consult Factory for non-standard Escutcheon Plates 4

APPLICATION INSTRUMENT AND CONTRC ONTROL OL ROTARY ES FOR INSTRUMENT CONTROL ESCUTCHEON - 3 Phase, Phase to Phase Three current Transformers Cat. No. 95415C Depth behind panel 4.30-1 3 9510C - 4A3C WATTMETER 3 Phase, Three current Transformers Three current Potential Transformers Cat. No. 95419C Depth behind panel 3.60 WATTMETER ON 9510D - W14 WATTMETER 3 Phase, Two current Transformers Two current Coils Two potentials Coils Cat. No. 9540C Depth behind panel 3.60 WATTMETER ON 9510D - W14 WATTMETER REVERSING Cat. No. 9541C WATTMETER W RVA 9510C - 3W16 POWER-FACTOR 3 Phase, Two current Transformers One or Two current Coils Cat. No. 954C Depth behind panel.40 P.F. METER ON 9510D- P14 SYNCHRONIZING Machine to bus with interlocks Handle: Oval, removable Cat. No. 9544E SYNCHROSCOPE ON 9511D -S17 5 Consult Factory for non-standard Escutcheon Plates

INSTRUMENT AND CONTRC ONTROL OL ROTARY ES FOR INSTRUMENT CONTROL APPLICATION ESCUTCHEON MOTOR CONTROL GOVERNOR OR RHEOSTAT Split field motor Cat. No. 9547D Depth behind panel.40 MOTOR CONTROL RAISE LOWER 9510B-M TRIP Double Pole / Single Throw contacts normally open Cat. No. 95436D Depth behind panel.40 TRIP 9510D -1B18 CONTROL Cat. No. 95438D Depth behind panel.40 9518B - B3 CONTROL Cat. No. 95440D Depth behind panel.40 9518B -B3 CONTROL Operate two breaker Cat. No. 95441D Depth behind panel.40 9518B -B3 CONTROL Operate two breaker Cat. No. 9544D Depth behind panel 4.30 9518B -B3 Consult Factory for non-standard Escutcheon Plates 6

INSTRUMENT AND CONTRC ONTROL OL APPLICATION ESCUTCHEON ROTARY SELECTOR ES CONTROL Cat. No. 95443D Depth behind panel 4.70 9518B -B3 CONTROL TRIP CLOSE Cat. No. 95444D Depth behind panel 4.70 9518B -B3 CONTROL TRIP CLOSE Cat. No. 95445D Depth behind panel 5.40 9518B -B3 CONTROL TRIP CLOSE Cat. No. 95446D Depth behind panel 5.40 9518B -B3 CONTROL Cat. No. 95450D Depth behind panel 4.70 PULL-TO LOCK 9519C-3B33 CONTROL Cat. No. 9545D Depth behind panel 6.90 PULL-TO LOCK 9518B -B3 7 Consult Factory for non-standard Escutcheon Plates

INSTRUMENT AND CONTRC ONTROL OL APPLICATION ESCUTCHEON ROTARY SELECTOR ES CONTROL UNIVERSAL CIRCUIT Cat. No. 95457D Depth behind panel 6.0 9518B -B3 CONTROL UNIVERSAL CIRCUIT Cat. No. 95458D Depth behind panel 8.00 PULL-TO LOCK 9518C -B3 Consult Factory for non-standard Escutcheon Plates 8

- ON SINGLE - THROW 1 DOUBLE THROW (ON ) DESCRIPTION DOUBLE THROW (WITH ) STOPS 1 & 7 1 & 7 INSTRUMENT AND CONTRC ONTROL OL DETENT SELECTOR CATALOG NUMBERS ** The catalog numbers are for universal switches that provide all contacting shown. Oval handle supplied. To limit switches to positions shown put limit screws in holes in rear stop plate shown as Stops. Order jumpers as required, as separate items. DECKS CATALOG NO. INCHES* 1 95401B.4 9540B.9 3 95403B 3.6 4 95404B 4.3 5 95405B 4.8 6 95406B 5.4 7 95407B 6. 8 95408B 6.6 9 95409B 7.4 10 95410B 8.0 * DEPTH BEHIND PANEL 3 & 7 - ON SINGLE - THROW 4 DESCRIPTION DOUBLE THROW SINGLE - THROW The above switch will family will be provided as DEVELOPMENT 3 unless otherwise specified. By changing stop screw location and wiring connections the switch may be configured by the consumer as DEVELOPMENTS 1 or. Escutcheon for DEVELOPMENT 3 provided as standard unless DEVELOPMENT 1 or specified at time of order. This External Jumper provided to allow common input to circuit 1 &. However removal of the Jumper does not isolate the two currents as these two terminals are tied together internally in the off position. MOMENTARY (SPRING RETURN) ACTION ES STOPS 1 & 7 CATALOG NUMBERS ** The catalog numbers are for universal switches that provide all contacting shown. Oval handle supplied. To limit switches to positions shown put limit screws in holes in rear stop plate shown as Stops. Order jumpers as required, as separate items. DECKS CATALOG NO. INCHES* 1 957401B.4 5 DOUBLE THROW (WITH ) 1 & 7 95740B.9 3 957403B 3.6 4 957404B 4.3 5 957405B 5.3 * DEPTH BEHIND PANEL & 7 9 6 The above switch will family will be provided as DEVELOPMENT 6 unless otherwise specified. By changing stop screw location and wiring connections the switch may be configured by the consumer as DEVELOPMENTS 4 or 5. Escutcheon for DEVELOPMENT 6 provided as standard unless DEVELOPMENT 4 or 5 specified at time of order.

INSTRUMENT AND CONTRC ONTROL OL ROTARY SELECTOR ES DESCRIPTION STOPS CATALOG NUMBERS TRIPLE THROW (WITH ) 7 4 THROW (WITH ) 8 5 - THROW (WITH ) 1 & 5 1 & 4 ** The catalog numbers are for universal switches that provide all contacting shown. Oval handle supplied. To limit switches to positions shown put limit screws in holes in rear stop plate shown as Stops. Order jumpers as required, as separate items. DECKS CATALOG NO. INCHES* 1 954301B.4 95430B.9 3 954303B 3.6 4 954304B 4.3 5 954305B 4.8 6 954306B 5.4 7 954307B 6. 8 954308B 6.6 9 954309B 7.4 10 954310B 8.0 * DEPTH BEHIND PANEL 9 6 - THROW (WITH ) 1 & 3 10 7- THROW (WITH ) 1 & SHOWN IN POSITION 11 NONE The above switch will family will be provided as DEVELOPMENT 11 unless otherwise specified. By changing stop screw location and wiring connections the switch may be configured by the consumer as DEVELOPMENTS 7 or 10. Escutcheon for DEVELOPMENT 11 provided as standard unless DEVELOPMENT 7 or 10 specified at time of order. JUMPERS Strap jumpers are available for adjacent contacts, and wire lug assemblies are available for other terminal jumping. The strap jumpers are available in packages of ten or twenty-five. The wire and lug assemblies are ordered individually. Data is as follows: (Strap jumpers are silver-plated brass.) CATALOG NO: 950011-10-C3 95001--C3 DESCRIPTION Jumper, adjacent terminals on the same deck. Jumper, same terminal location on adjacent deck. (Wire and lug assemblies have #10 AWG wire and insulated ring lugs.) CATALOG NO: LENGTH (L) 950001-1 3-1/16 950001-4 - 1/4 950001-3 3-5/8 L 10

INSTRUMENT AND CONTRC ONTROL OL SERIES 95 LOCK OUT RELAY ES SEE NOTE 4 * D.13.63 TYP 1.75 4.75 (SHOWN WITHOUT HANDLE FOR CLARITY) 3.00 TYPICAL CONTACT DECKS SHOWN, THE EXTRA DECK IN FRONT IS FOR COIL CLEARING DRILL PATTERNS & ESCUTCHEON PLATE DIMENSIONS Notes: All switch assemblies include the following 1. 1 - Escutcheon plate.. 3 - No.10-3 x 5/8 screw. 3 Pistol grip is shown on front cover. Switches with 6 or more decks require nd torsion spring assembly. Complete technical data is outlined in Technical Publication ITLOR95. (DTS-ITILOR95) DEPTH BEHIND PANEL UL File No. E101598 GENERAL PURPOSE RATING 30A 600V Open CARRY 0A 600V enclosed CARRY 0A 10VAC.8 PF, MAKE & BREAK 15A 40VAC.8 PF, MAKE & BREAK 6A 600VAC.8 PF, MAKE & BREAK 3A 15VAC RESISTIVE MAKE & BREAK 1A 50VAC RESISTIVE MAKE & BREAK NUMBER OF DECKS DEPTH INCHES D 1 3.6 4.3 3 4.7 4 5.5 5 6. 6 7.5 7 8.1 8 8.5 9 9. 10 9.6 11

INSTRUMENT AND CONTRC ONTROL OL LOCK OUT RELAY ES MANUAL RESET LOR CONTACT DECK LAYOUT MANUAL RESET LOR n=deck number LOR TRIP COIL NO ADDITIONAL CIRCUITY (TARGET) A TARGET RESISTOR (R0) IN PARALLEL A TARGET RC CIRCUIT A TARGET SERIES RESISTOR (RS).A.6A.A 5 OHMS 50 OHMS 40 OHMS 0 OHMS 7 OHMS 1.3 OHMS 16.7 OHMS A B 1 1 4 90 90 C D 4 40 118 80 95 105 95 E F 40 150 75 70 150 15 COIL COIL CKT VOLTAGE COIL CURRENT @ NORMAL VOLTAGE OPERATING RANGE COIL CURRENT @ MAXIMUM VOLTAGE OF OPERATING RANGE COIL RESISTANT @5 0 C A 4VDC 7.3 10-40VDC 1. AMPS DC 3.3 B 4VDC 3. 18-50VDC 6.5 AMPS DC 7.7 C 48VDC 3.7 4-70VDC 5.4 AMPS DC 13 TYPICAL DEVELOPMENT FOR DECKS 1 THRU 10 D 15VDC 4.6 30-140VDC 5. AMPS DC 7 E 15VDC.5 45-150VDC.8 AMPS DC 50 F 50VDC.4 70-80VDC.7 AMPS DC 104 WHERE n IS DECK NUMBER DECKS 10-40 VDC A COIL 18-50 VDC B COIL 4-70 VDC C COIL 30-140 VDC D COIL 45-140 VDC E COIL 70-80 VDC F COIL 1 957801A 957801B 957801C 957801D 957801E 957801F 95780A 95780B 95780C 95780D 95780E 95780F 3 957803A 957803B 957803C 957803D 957803E 957803F 4 957804A 957804B 957804C 957804D 957804E 957804F 5 957805A 957805B 957805C 957805D 957805E 957805F OPERATING DC VOLTS 150 15 LOR TRIP COILS TO USE. A TARGET. A TARGET A, B, C B,C,D,E 6 957806A 957806B 957806C 957806D 957806E 957806F 7 957807A 957807B 957807C 957807D 957807E 957807F 8 957808A 957808B 957808C 957808D 957808E 957808F 9 957809A 957809B 957809C 957809D 957809E 957809F 10 957810A 957810B 957810C 957810D 957810E 957810F 150 15 140 190 50 D,E,F D,E,F D,E,F F F D D D D * D COIL HAS BEEN TESTED AND APPROVED FOR USE AT 10V AC 1

INSTRUMENT AND CONTRC ONTROL OL OPERATION - 4 ROWS OF LEDS: Style 1, Standard Light Configuration When the handle is turned to the CLOSE position, The flag shows red and the red lights are turned on by an auxiliary switch contact in the circuit breaker. If there is a fault and the circuit breaker trips, an auxiliary switch contact (bell circuit) in the Circuit breaker will close and the yellow lights flash - see typical circuit on page 14. When the handle is turned to the TRIP position, the flag shows green and the green lights are turned on by an auxiliary switch contact in the circuit breaker. Style, (Reversed light Configuration) is selected, the above operation will apply but exchange red to green and green to red. LIGHTED ESCUTCHEON PLATES OPERATION - ROWS OF LEDS: Style 1, Standard Light Configuration When the handle is turned to the CLOSE position, the flag shows red and lights are turn on by an auxiliary switch contact in the circuit breaker. When the handle is turned to the TRIP position, the flag shows green and the green lights are turned on by an auxiliary switch contact in the circuit breaker. Style, (Reversed light Configuration) is selected,the above operation will apply but exchangered to green and green to red. STYLE 1 ROWS OF LED VOLTAGE RATING SERIES 95 DASH # LEDS 10 VAC 50/60 HZ or 15VDC -LR10 40 VAC 50/60 HZ or 50VDC -LR40 48VDC -LR48 10 VAC 50/60 HZ or 15VDC 4 -L4R10 40 VAC 50/60 HZ or 50VDC 4 -L4R40 48VDC 4 -L4R48 MATERIALS LIST: All lighted flag assemblies include the following- Escutcheon plate with flag assembly. Pistol grip handel with #6-3 x 5/8 screw Wire connections are made with #6-3 x 3/9 slotted brass screws with lock washers. Switch mounting hardware, 3 ea #10-3 x 1 slotted truss head, black zinc plated screws. Notes: 1. Panel Mounting. Jumper may be added to terminals D, E and/or F for common circuit connections for LEDs. 3. Voltage input is not polarity sensitive. ORDERING INSTRUCTIONS: Specify standard switch catalog number and add Lighted Escutcheon DASH NUMBER, ex: 95438D-L4R10. The Lighted Escutcheon requires a special handle and length mounting screws, so the DASH NUMBER must be included on the initial switch order. STYLE REVERSED LIGHT CONFIGURATION ROWS OF LED VOLTAGE RATING SERIES 95 DASH # LEDS 10 VAC 50/60 HZ or 15VDC -LR10R 40 VAC 50/60 HZ or 50VDC -LR40R 48VDC -LR48R 10 VAC 50/60 HZ or 15VDC 4 -L4R10R 40 VAC 50/60 HZ or 50VDC 4 -L4R40R 48VDC 4 -L4R48R INDICATION COLOR TERMINAL DESIGNATIONS DISPLAY OPEN GREEN A & D STEADY CLOSED RED B&E STEADY *TRIPPED YELLOW C & F FLASHING INDICATION COLOR TERMINAL DESIGNATIONS DISPLAY OPEN RED A & D STEADY CLOSED GREEN B&E STEADY *TRIPPED YELLOW C & F FLASHING Patented Feature: Leds are removable. If any Led fails and it is removed all others in the row remain lit. 13

INSTRUMENT AND CONTRC ONTROL OL LIGHTED ESCUTCHEON PLATES REAR VIEW QTY PART # COLOR 6 LED MV6351 YELLOW 6 LED MV6451 GREEN 6 LED MV6951 RED Notes: 1. LEDS are removable and inserted by the use of needle nose pliers. Polarity should be observed during installation. 3. Molded escutcheon panel LED ports are polarized. DRILL PATTERN ESCUTCHEON ASSEMBLY FRONT COVER WITH FLAG ROWS OF LEDS PART# 179C48 4 ROWS OF LEDS PART# 179C4867 MOLDED PISTOL GRIP HANDLE PART# 179B0856 CUSTOMER PANEL DECKS SERIES 95 ASSEMBLY STANDARD OUTLINE, NOT MODEL SPECIFIC PROTRUSION OF LEDS WHEN FULLY ASSEMBLED 14

USA, Canada, Asia, Latin America Tel: +1-800-547-869 Fax: +1-905-01-455 e-mail: sales.multilin@ge.com Europe, Middle East, Africa Tel: +34-94-485-88-00 Fax: +34-94-485-88-45 e-mail: gemultilin.euro@ge.com Series 95 Switches Please refer to our website for more detailed contact information CS00A40786 Rev. 10/09