AAS Meeting, Anchorage, Alaska, June 2012 Ian McLean (Principal Investigator)

Similar documents
The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

Spectrophotometry of Ap Stars

FTIR Instrumentation

Chapter 6 Telescopes: Portals of Discovery. How does your eye form an image? Refraction. Example: Refraction at Sunset.

Development of the Extreme Ultraviolet Spectrometer: EXCEED

ID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC

High Resolution Imaging in the Visible from the Ground without Adaptive Optics: New Techniques and Results

LSST Data Management. Tim Axelrod Project Scientist - LSST Data Management. Thursday, 28 Oct 2010

A.-L. Maire, S. Desidera, S. Esposito, A. Skemer, P. Hinz, & the LEECH & HOSTS teams

Sky Monitoring Techniques using Thermal Infrared Sensors. sabino piazzolla Optical Communications Group JPL

Passive Millimeter-Wave Imaging and Potential Applications in Homeland Security and Aeronautics

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Arrayoptik für ultraflache Datensichtbrillen

High Resolution Imaging of Satellites with Ground-Based 10-m Astronomical Telescopes

The Field Camera Unit project for the WSO-UV space telescope

The Sino-French Gamma-Ray Burst Mission SVOM (Space-based multi-band astronomical Variable Objects Monitor)

RESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR

Optical laser beam scanner lens relay system

Introduction to Fourier Transform Infrared Spectrometry

Adaptive Optics High Resolution IR Spectroscopy with Silicon Grisms and Immersion Gratings 1. Abstract

Performance of the W.M. Keck Observatory Natural Guide Star Adaptive Optic Facility: the first year at the telescope

Challenges in DWDM System Spectral Analysis By Laurent Begin and Jim Nerschook

Performance and results with the NIRSPEC echelle spectrograph on the Keck II Telescope

The Optical Design of the High Resolution Imaging Channel for the SIMBIO-SYS experiment on the BepiColombo Mission to Mercury

A STEP 400 Technical development status

How Does One Obtain Spectral +Imaging Data

LSST and the Cloud: Astro Collaboration in 2016 Tim Axelrod LSST Data Management Scientist

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Module 13 : Measurements on Fiber Optic Systems

Recording the Instrument Response Function of a Multiphoton FLIM System

Anamorphic imaging with three mirrors: a survey

Chapter 12 Filters for FISH Imaging

M. Rovira Instituto de Astronomía y Física del Espacio C.C.67 Suc.28 (1428) Buenos Aires. in Argentina

Very Large Telescope

Fig.1. The DAWN spacecraft

An Airborne A-Band Spectrometer for Remote Sensing Of Aerosol and Cloud Optical Properties

- the. or may. scales on. Butterfly wing. magnified about 75 times.

Spectroscopy Using the Tracker Video Analysis Program

Light Telescopes. Grade Level: class periods (more if in-depth research occurs)

How does my eye compare to the telescope?

Spatially resolved spectroscopy of the exoplanet HR 8799 c

COOKBOOK. for. Aristarchos Transient Spectrometer (ATS)

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Possible use of the dedicated MARLY one meter telescope for intensive supernovæ studies

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Characterization and on-sky demonstration of an integrated photonic spectrograph for astronomy

Simplicity. Reliability. Performance

Planetary Imaging Today. Bryan Cogdell, Celestron LLC

How To Build An Infrared Telescope In Chile

INTA AIRBORNE REMOTE SENSING FACILITY from the Hasselblad s cameras to the SensyTech-AHS sensor

Realization of a UV fisheye hyperspectral camera

LUCIFER. LMS Version LMS User Manual. Document Number: LBT-LUCIFER-MAN 030. Issue Number: Issue 1.0

MY FIRST STEPS IN SLIT SPECTROSCOPY

1 Laboratory #5: Grating Spectrometer

Detecting and measuring faint point sources with a CCD

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

Hydrogen Bonds in Water-Methanol Mixture

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter

1. Introduction to image processing

NASA s Dawn Mission Journey to the Asteroid Frontier

A Wide-Field Infrared Camera for the Palomar 200-inch Telescope

How To Make A Plasma Control System

A pretty picture, or a measurement? Retinal Imaging

Nederland België / Belgique

Homeland Security, Medical, Pharmaceutical and Non-destructive Testing Applications of Terahertz Radiation

One Degree Imager Pipeline Software and Archive Science Requirements Document

Experiment 5. Lasers and laser mode structure

Raman spectroscopy Lecture

The multibeam receiver for SRT, the Sardinia Radio Telescope

Introduction to reflective aberration corrected holographic diffraction gratings

3 - Atomic Absorption Spectroscopy

The Wide Field Cassegrain: Exploring Solution Space

LaserLight Networks Inc.

RECOMMENDATION ITU-R SM Measuring sideband emissions of T-DAB and DVB-T transmitters for monitoring purposes

Development of VIRUS Alignment and Assembly Fixtures

Lessons Learned from SOFIA

Spectral Measurement Solutions for Industry and Research

Status of the Free Electron Laser

Observing Lake Erie Algae Blooms via. Hyper Spectral Imaging on CubeSat

INFRARED PARTS MANUAL

High Brightness Fiber Coupled Pump Laser Development

How To Use 3D On A Computer Or Tv

Adaptive Optics Testbed for the Visible High Resolution Imaging

SphinX:A Fast Solar Photometer in X-rays. J. Sylwester 1,, S. Kuzin 2, Yu. D. Kotov 3, F. Farnik 4 & F. Reale 5

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Association of Mid-Infrared Solar Plages With Calcium K Line Emissions and Magnetic Structures

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Alpy guiding User Guide. Olivier Thizy François Cochard

Star Detection and Removal in Night Airglow Images

Herschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -

arxiv:astro-ph/ v1 20 Feb 1998

A prototype phasing camera for the Giant Magellan Telescope

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

Data Sheet. definiti 3D Stereo Theaters + definiti 3D Stereo Projection for Full Dome. S7a1801

Solutions for Quality Control of multi-detector instruments and their application to CRIRES and VIMOS

Transcription:

AAS Meeting, Anchorage, Alaska, June 2012 Ian McLean (Principal Investigator) UCLA Infrared Laboratory University of California, Los Angeles 1

Sunset, Thursday October 13, 2011 Dryden Aircraft Operations Facility, Palmdale, CA FLITECAM & HIPO Ian and Erin ready to board The Team Photos by Chris Johnson, IRLab LIFT-OFF at 18:20 2

What is FLITECAM? FLITECAM is a camera and spectrometer for 1-5 microns. Detector: the 1 megapixel (1024x1024) InSb (ALADDIN III). Image Scale: ~0.475 arcsec per pixel. Filters: JHKLM broad-band and selected narrow-bands (1%-4%). Spectroscopy: three direct-ruled KRS5 grisms and an aperture mask with a pair of long slits; either 1ʺ or 2ʺ in width and each 60ʺ in length. Resolving power: R~1,800 for the 1ʺ slit. High-speed movie mode for occultations; and pupil-viewing mode. FLITECAM can be stand-alone or co-mounted with HIPO. Astronomical observing requests (scripts) and a real-time data reduction pipeline (DRP) for dithered image patterns demonstrated. McLean, I. S. et al. 2006, Proc. SPIE, 6269, 168. Smith, E.C.D. & McLean, I. S. 2008, Ap. J., 676, 408. 3

Layout for Imaging and Spectroscopy InSb Detector Format: 1024 x 1024 pixels Pixel size on sky: 0.475ʺ x 0.475ʺ IMAGING SPECTROSCOPY Array perimeter Field stop Dispersion Slit mask FOV: ~8ʹ diameter Spectrum Imaging area used in dither mode: ~5.6ʹ x 5.6ʹ Best image quality region 64x64 sub-array for high speed mode: 30ʺ x 30ʺ 2ʺ 60ʺ Slits 60ʺ 1ʺ R~1000 R~2000 The detector has poor performance in the corners. 4

FLITECAM FILTER SET Filter Wheel 1 Filter Wheel 2 blank/dark (77 K) Pupil Viewing lens open Open J Paschen-alpha (1.88 µm) H A grism spectroscopy K Paschen-alpha (continuum 1.9 µm) Lʹ Narrow Band L (3.6 µm) L B grism spectroscopy M Ice (3.08 µm) Hwide PAH (3.29 µm) Kwide Narrow Band M (4.6 µm) Klong C grism spectroscopy L&M N/A 5

6 FLITECAM FILTER PASSBANDS

Order-sorting filter (OSF) passbands Start, Center and End wavelengths for each passband are given in microns Spectral coverage is displayed pictorially in the next slide. 7

m=3 m=2 m=1 m=3 m=2 m=1 A m=4 m=3 m=2 C B Wavelength (microns) 8

FLITECAM HIPO 9

FIRST FLIGHT - GOALS Installed October 2011 on SOFIA in FLIPO configuration: HIPO and FLITECAM co-mounted; reflected light to FLITECAM Warm optics in front of FLITECAM window; dichroic and folding flat Mainly for support of SOFIA Characterization And Integration (SCAI) Some partial FLITECAM commissioning if time permits Four flights achieved in October 2011 Tests: Imaging in most filters full-array and sub-array modes; dither patterns Spectroscopy observations used both low and high resolution slits Gyro drift observations Emissivity tests Engine exhaust tests Image size as a function of wavelength Throughput and backgrounds 10

11 SCAI FLIGHT RESULTS Unable to complete some critical tests because: Detector electronics damaged when cabin overheated during aircraft wash; lost one quadrant of detector for all SCAI flights. Instrument/Observatory interface problems made slit-nodding and dither pattern execution unreliable; sometimes lost pointing during telescope Line-Of-Sight (LOS) Resets. Backgrounds higher than expected; partly due to emissivity of FLIPO configuration; also due to internal effects after filter distribution was changed. Sensitivity as expected in J, H and K; can t confirm L and M yet. Performance at Paschen-alpha very encouraging. Best image size as function of wavelength occurred ~3 microns. Clear evidence of image jitter in cross-elevation direction. Thermal emission due to engine exhaust evident for el < 35

Throughput and Image Quality Tests Zeropoints from standard stars consistent with ground-based results for J, H and K bands. Best images were seen around 3 microns with FWHM ~3.0ʺ Image elongation seen in cross-elevation direction; mainly secondary mirror motion excited by wind on a baffle plate. 12

STATUS AND PLANS FLITECAM is back in the Lab at UCLA for refurbishment. Missing detector quadrant repaired; protocols now in place to prevent over-heating of aircraft cabin when instruments in use. Software enhancements under way; pending new releases of SOFIA MCCS or telescope control software. Major activity is to improve pointing and software interaction. Baffle plate will be removed for next flights; possibly add an improved beamsplitter and SI blower for cooler fore-optics. Experiments under way to track down internal light leaks and eliminate excess thermal background FLITECAM (stand-alone) commissioning not scheduled until late 2012 or early 2013. FLITECAM will be available for shared-risk observing. 13

Images using the 1% Paschen-alpha filter Thank you 14