IntesisBox. BACnet/IP Server - LON. Integrate LonWorks devices or systems into BACnet control systems. IntesisBox RS232. Only needed for configuration

Similar documents
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox ASCII Server - LON

IntesisBox KNX - LON

IntesisBox KNX Modbus TCP master

IntesisBox KNX LG Air Conditioning

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX Modbus RTU master

Modbus Server SAMSUNG Air Conditioners

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox Modbus Server SAMSUNG Air Conditioners

KNX Panasonic Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox KNX Mitsubishi Heavy Industries AC

Electronic Control Devices The European Product Catalogue 2007

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

User manual Compact Web PLC WP240 series IEC-line

PCS0100en Persy Control Services B.V. Netherlands

Portable BACnet /IP to MS/TP Router

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Electronic Control Devices The European Product Catalogue 2007

IntesisBox. Making Building Automation go further. KNX EIB Products

1 Serial RS232 to Ethernet Adapter Installation Guide

Tracer Summit Web Server

HWg-STE HWg-STE PoE MANUAL

IntesisBox. Making Building Automation go further. Modbus Products

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Optimize your simple machines... Modicon M218 Selection Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Industrial Bar Code Scanners

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

User Manual Revision English

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TX OPEN RS232/485 module

T3 Mux M13 Multiplexer

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Communication standards and Carel solutions

Configuring PROFINET

User Manual. EtherUSB

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

HMI display Installation Guide

INTRODUCTION FEATURES OF THE ICM

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

MCS-BMS-GATEWAY STARTUP GUIDE

Climate Ready Control Systems Technical Specifications

M2M/IoT Solutions.

FX07 Field Controller

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

connecdim Gateway G1 Ethernet TCP/IP to DALI

Modbus and ION Technology

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Lab Diagramming Intranet Traffic Flows

One Port Serial Server Users Manual Model ESP901, ESP901E

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Digital Marquee Series

SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

Using IDENT M System T with Modbus/TCP

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

EZ-View Network Communications Guide

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

PLC training panel (Twido version)

FINS Gateway For OMRON PLCs

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

GV-Data Capture V3 Series User's Manual

ewon COSY 141 Installation Guide

HARTING econ 3000 Introduction and features

RS-232/422/485, Power over Ethernet

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

EIB/KNX IP Interface with Power over Ethernet (PoE)

Controller board and power supply for vivimat III systems

R-Win. Smart Wireless Communication Management System

Installation and Operation Guide

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Telephone- and leased line modem for industrial applications TD-36

Foxboro Evo Process Automation System

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

NEW. EVEN MORE data acquisition and test stand automation

Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006

User Manual Revision English

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Modbus and ION Technology

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Debugging Network Communications. 1 Check the Network Cabling

FX07 Field Controller

Transcription:

IntesisBox Server - LON Gateway for integration of LON devices into BACnet control systems Integrate LonWorks devices or systems into BACnet control systems. BACnet IP client Ethernet LonWorks TP/FT-10 network BACnet IP client LAN TCP/IP IntesisBox LinkBoxBacnet Configuration Software RS232 Only needed for configuration IntesisBox is a Server device allowing read/write network variables (SNVTs) of LON devices connected to a LON network, and offering these values through standard BACnet objects. SNVT values in LON can be read/write from BACnet. Each LON basic data type of network variables in LON devices can be mapped into an individual BACnet object. IntesisBox acts as a Server device in its BACnet interface, allowing other BACnet IP client devices read and write its internal points, readings can be by polling or by subscription (COV) requests. LON interface of IntesisBox reads continuously LON devices configured by polling. LON devices can be addressed either using Neuron-Id (physical address) or subnet/node for commissioned networks. IntesisBox has the ability to declare devices as commissioned, if needed, thus avoiding the need for a LON integration tool for commissioning (i.e. LonMaker). All the updated readings are maintained in IntesisBox memory for immediate interaction with the BACnet system. IntesisBox Server series are configured using LinkBoxBacnet, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. With the installation of LinkBoxBacnet, a Demo project for integration of LON devices is also installed; using this demo project makes the engineering needed for this integration easy and quick. 1 / 9

IntesisBox capacity Element Type of BACnet devices Max. (Tiny version) Max. (Basic version) Max. (Extended version) Notes Those supporting. Number of BACnet points 100 500 3000 Maximum number of points (BACnet objects) that can be defined into IntesisBox. Each of them can contain an individual field from a LON network variable. Number of BACnet subscribers Number of BACnet subscriptions (COV) requests Type of LON devices Supported number of LON devices 8 8 8 Maximum number of BACnet subscribers accepted by IntesisBox. 6000 6000 6000 Maximum number of BACnet subscriptions (COV) requests accepted by IntesisBox. Those supporting Free Topology channel (FT-10) 128 128 128 Maximum number of different LON devices that can be defined into IntesisBox (to read/write points into them). There are three versions of IntesisBox with different capacity every one of them: Tiny version with capacity of 100 points. Ref.: IBOX-BAC-LON-100 Basic version with capacity of 500 points. Ref.: IBOX-BAC-LON-A Extended version with capacity of 3000 points. Ref.: IBOX-BAC-LON-B 2 / 9

Sample applications Integration of LonWorks and BACnet using IntesisBox BACnet IP Server LON gateway. BACnet IP client Ethernet LonWorks TP/FT-10 network BACnet IP client LAN TCP/IP IntesisBox BACnet control system Typical LON devices Building Management Systems (BMS). SCADA packages. Human Machine Interfaces (HMI). Direct Digital Controllers (DDC). Programmable Logic Controllers (PLC). Lighting control systems Building Automation devices. HVAC Controllers. Air Conditioning gateways. BACnet Full monitoring and control LonWorks System monitoring / controlling System under monitoring / control 3 / 9

Typical applications Integration of a LonWorks based control sub-system into BACnet based Building Management Systems SCADA Ethernet Controller Router controllers Sensors Field Controller Field Controller IntesisBox Actuators Dimmers Field Controller LonWorks based control sub-system BACnet based Building Control IntesisBox full integration LonWorks 4 / 9

BACnet interface of IntesisBox BACnet interface Device type BACnet modes supported BACnet configuration parameters Interactivity with BACnet system Server IP address. Subnet mask. Default router address. BACnet port. BACnet device name. BACnet device number (device instance number). Point's Read/Write allowed. Subscription requests (COV) allowed. BACnet interface specifications BACnet Conformance Class Supported: Class 3 Data Link Layer Option: BACnet IP, (Annex J) Segmented Requests/Responses Not Supported BACnet Standard Application Services Supported and more details are explained in BACnet IP Server KNX PICS (protocol implementation conformance statement) /pdf/intesisbox_bacnet_ip_server_lon_pics.pdf Types of BACnet objects supported Object Type Property Description Analog Input Present Value Analog signal Analog Output Present Value Analog signal Analog Value Present Value Analog signal Binary Input Present Value Digital signal Binary Output Present Value Digital signal Binary Value Present Value Digital signal Multistate Input Present Value Multistate signal Multistate Output Present Value Multistate signal Multistate Value Present Value Multistate signal 5 / 9

LON interface of IntesisBox Specifications LON supported channel: Free Topology (FT-10) Configurable addressing options (on a per device basis): Subnet / node Neuron-Id Network variable sample rate: Below 60ms per network variable (each network variable may contain several fields, which will be mapped to different Modbus registers, if needed). Supported network variable types: All standard network variable types published by LonMark International are directly supported by configuration tool, LinkBoxBacnet. Support for user-defined network variable types can be added in each case, by entering their definition in LinkBoxBacnet. In this case, following information needs to be provided: Scale factors: a, b and c Number of fields Basic LON data type of each field Supported basic LON data types Basic LON data type Description Signed short 8-bit signed data Unsigned short 8-bit unsigned data Enum 8-bit unsigned data Signed long 16-bit signed data Unsigned long 16-bit unsigned data Signed quad 32-bit signed data Unsigned quad 32-bit unsigned data Float 32-bit IEEE float Bitfield 1 to 8-bit length unsigned bit field 6 / 9

Configuration tool LinkBoxBacnet Visual engineering tool, easy of use, for IntesisBox s configuration and monitoring, compatible with Microsoft Windows TM operating systems, supplied with the purchase of IntesisBox with no additional cost. Multi-window tool allowing to monitor simultaneously the communication activity with both protocols (systems) and the real time values for all the points allowing to modify any value (very useful for test purposes), console window showing debug and operating status messages, and configuration windows to configure all the IntesisBox s parameters and points. Point s configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the IntesisBox s parameters and points while in off-line, this is, not connected to the gateway. You can configure/modify the IntesisBox's parameters comfortably in the office and later download the configuration to the gateway in the field. Connection to the IntesisBox for download the configuration and monitoring the operation by using a serial COM port of the PC (serial cable also supplied with the IntesisBox). Allows configuring all the external protocols available for IntesisBox Server series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Server series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites where different IntesisBox Server series gateways have been installed. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the IntesisBox, for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). In LinkBoxBacnet, an embedded tool for import XIF files makes the configuration of the IntesisBox for integration of any kind of LON device easy and quick. 7 / 9

Technical characteristics Envelope Plastic, type PC (UL 94 V-0). Size: 107mm x 105mm x 58mm. Color Grey. RAL 7035. Power 9 to 30Vdc +/-10% 1.4W. 24Vac +/-10% 1.4VA. Power connector is a 2 poles plug-in terminal block. Mounting options Wall DIN rail EN60715 TH35. port 1 x Ethernet 10BT RJ45. LON Port 1 x LON (TP-FT/10) (2 poles plug-in screw terminal block). LED indicators 1 x Power. 2 x LON port activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). 1 x LON service. 1 Push buttons 1 x LON service switch. 1 Console port EIA232. DB9 female connector (DCE). Configuration Via console port. 2 Firmware Allows upgrades via console port. Functional 0 C to +70 C temperature range Functional humidity 25-90% at 50ºC, non condensing range Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 2 Not used for the moment. Reserved for future use. Along with the device it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM port. The configuration software, compatible with MS Windows operating systems, is also supplied. 8 / 9

Dimensions Ethernet port + Power 58 mm LON port Console port 107 mm 105 mm Free space recommended installing the device into a cabinet (wall or DIN rail mounting), with spacing enough for external connections: 100 mm 115 mm 130 mm 9 / 9