Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000



Similar documents
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

Bluetooth to Serial Adapter

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

DUKANE Intelligent Assembly Solutions

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

Voice Over Internet Protocol (VoIP) Configuration

Connecting and Setting Up Your Laptop Computer

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Accessing Diagnostics using a Dialup Modem

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Using HyperTerminal with Agilent General Purpose Instruments

Keep it Simple Timing

DIAL-UP DATA. User s Guide

omni.net Plus/D Q u i c k S t a r t G u i d e

Connecting the Console Port to a PC

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

PM1122 INT DIGITAL INTERFACE REMOTE

Connecting the DG-102S VoIP Gateway to your network

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

Introduction: Implementation of the MVI56-MCM module for modbus communications:

One Port Serial Server Users Manual Model ESP901, ESP901E

Palomar College Dial-up Remote Access

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Installation Guide (No Router)

IP SERIAL DEVICE SERVER

Bluetooth HC-06 with serial port module Easy guide

PRILINK PRI Management System

Maintaining the Content Server

User Manual. Thermo Scientific Orion

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Plena Voice Alarm System Firmware update

Installing MPU-401 Compatible Cards in Windows 95

Omni 56K USB Lite Quick Start Guide

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

Liebert IntelliSlot Web Cards

POS Integration. Prepared by: Binh Nguyen

T3 Mux M13 Multiplexer

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

DIAL-UP DATA. User s Guide

SCS3205/4805 Quick Start Guide

GV-Data Capture V3 Series User's Manual

Global Monitoring + Support

Setting Up the ZigBee Ethernet Gateway

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Iridium Extreme TM Satellite Phone. Data Services Manual

Crow Limited Warranty. Print Version 017

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

1. Installing The Monitoring Software

Networking Alpha signs on a TCP/IP network

1. Hardware Installation

How to setup a serial Bluetooth adapter Master Guide

DIRECT INTERNET 3. Install Guide for the Windows 7 Operating System

Modbus Communications for PanelView Terminals

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Config software for D2 systems USER S MANUAL

FUTURELIGHT RDM PC DIRECTOR

Metasys System Direct Connection and Dial-Up Connection Application Note

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

MODEM AND DIAL-UP. Installation/Configuration (Windows 95/98/Me/NT/2000/XP)

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Serial to Bluetooth Adapter

F2103 GPRS DTU USER MANUAL

HL2170W Windows Network Connection Repair Instructions

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections.

Communication Setup Application Note

HOW TO USE YOUR INTELE-MODEM

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

System Requirements. Hiro H50113

Linksys Gateway SPA2100-SU Manual

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

U.S. Robotics Modems: User s Guide

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

INTRODUCTION FEATURES OF THE ICM

WinPFT File Transfer Utility (Catalog No ND7)

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS

NortechCommander Software Operating Manual MAN R6

L Firmware And FPGA Configuration Upgrade

How To Set Up A Computer With A Network Connection On A Cdrom 2.5 (For A Pc) Or Ipad (For Mac) On A Pc Or Mac Or Ipa (For Pc) On An Ipad Or Ipro (

Transcription:

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version 2.x of the BrgTrack software, allows one or more of these direction finders to be controlled remotely over leased telephone lines. In the past, radio modems were required for the purpose. To check which firmware version you are using, watch the front panel display of the DDF6000 during power turn-on; to check the software version, use the Help About BrgTrack menu on the PC. If you are going to need an upgrade, see the Software & Upgrade page on the web site, or seek help from your local distributor or from the factory. 2.0 Configuration A modem pair is required for each remote site. The "calling" modem is located at the central control point where the PC running BrgTrack is located, and the "answering" modem is located at the remote site. If only one remote site is needed, the PC's COM port will connect to the sending modem using a 3-wire serial cable as shown in Figure 1. If multiple sites are to be connected, the Serial Expander, DDF6077 should be used. See Figure 2. A Serial Expander will interface a single PC COM port with up to three calling modems. If more than three sites are to be connected, multiple Serial Expanders may be used. See Figure 3. (The number of sites that may be connected using N Serial Expanders is equal to 2N + 1). Figure 1

Figure 2 Figure 3

3.0 Courier V.Everything Modem This modem is suitable for use as either the calling or answering modem with either leased lines or standard dial up lines. The following discussion assumes the standard external version of these modems. For more information on this modem, contact 3COM. According to 3COM, the modems must be identical and have the same internal software. The following procedure will check that the configuration is the same. 3COM also advises that the lines themselves should meet the following requirements: The leased line should be an analog 2-wire full duplex line (3002 type D) with no conditioning. It must not be a 4-wire or digital line. If the line is an actual dedicated line, its length should be 5 miles or less. If it is a true leased line with power provided by the telephone central office, then there is no limit on the length. Note that the cables and DIP switch settings used for modem setup are different from those used during normal modem operation with the DDF6000. 4.0 Modem Setup 4.1 Modem to PC Cable Note the serial connector used on your PC. It will be either a DE9 male or a DB25 male connector. When setting up the modems, you should use a serial cable and/or adapter that contains all of the RS232 handshake lines. If the PC has a 25 pin connector, use a standard DB25 male to DB25 female 25-conductor shielded cable. If the PC has a 9 pin connector, use a standard DE9 male to DE9 female 9-conductor shielded cable with a DE9 female to DB25 male adapter at the modem end. 4.2 PC Setup Run the Windows 95 Hyper Terminal program (Start Programs Accessories HyperTerminal). Set the communications parameters from the Terminal Program Properties menu which is accessed by selecting File Properties. On the Tab called Phone Number, change the Connect using box to read "Direct to COM n" where n is the COM port available on your PC. Click on Configure and set the Port Settings for Bits per second = 2400, Data Bits = 8, Parity = None, Stop bits = 1, and Flow control = Hardware. Check OK to return to the Terminal Program Properties menu. Select the tab marked Settings and select ASCII Setup. Deselect all the option boxes and click on OK. Click on OK again to return to the Hyper Terminal program screen.

With the modem power off, set the DIP switches on the modem so that switches 3, 5, 8, and 10 are down (ON) and all other switches are up (OFF). Do this for all of the modems to be used. When the modem power is turned on, this will load the factory default settings into the modem. Connect one of the modems to the PC using the cable described in section 4.1. Do not connect the RJ11 telephone cable. Turn the modem power on, wait a few seconds, then type AT<enter>. You should obtain the response OK from the modem. 4.3 Check Modem Software Configuration Select Transfer Capture to Printer and type ATI7<enter>. The screen should fill with a listing of the modem software configuration. Select Transfer Capture to Printer again. This will cause the information on the screen to be printed. Turn off the modem, disconnect the RS232 cable, connect the second modem to this cable, and turn it on. Repeat the above procedure to print out the software configuration. Repeat for the other modems to be used in the DF network. Compare the printed records. The same information should appear in the Option line, the Clock Frequency, and the Supervisor Rev. If the records are different, you should update the software in one or more of the modems so that all versions are identical. See the User manual and/or contact 3COM for information on obtaining the latest software and installing it. 4.4 Calling Modem with Leased Line Locate a modem that will be used at the PC (a calling unit). It is a good idea to mark this modem to distinguish it from the answering modems. Connect it to the PC using the same setup described in section 4.3. Verify that the program is communicating with the modem by typing AT <enter> and seeing that the modem responds with OK. Enter the following command line from the Hyper Terminal program: AT&F0&M0&B1&N3&L1S7=10S44=2&W<enter> The modem should respond with OK. If it does not, check the command line and enter it again. Turn the modem power off, and set the DIP switches so that switches 1, 4 and 5 are down (ON) and all other switches are up (OFF). The new settings will take effect when the modem is turned back on.

Repeat for all additional calling modems. 4.5 Answering Modem with Leased Line Locate a modem that will be used at the DF site (the answering unit). Connect it to the PC using the same setup described in section 4.3. Verify that the program is communicating with the modem by typing AT <enter> and seeing that the modem responds with OK. Enter the following command using Hyper Terminal: AT&F0&M0&B1&N3&L1S7=10S44=2&W<enter> The modem should respond with OK. If it does not, check the command line and enter it again. Turn the modem power off, and set the DIP switches so that switches 1 and 4 are down (ON) and all other switches are up (OFF). The new settings will take effect when the modem is turned back on. Repeat for all additional answering (DF site) modems. Note that the setup strings used in both calling and answering modems cause the modems to communicate at 2400 baud at both the serial port and over the telephone line, error checking/correction is disabled, and flow control is also disabled. 4.6 Calling Modem with Dialup Line Locate a modem that will be used at the PC (a calling unit). Connect it to the PC using the same setup described in section 4.3. Verify that the program is communicating with the modem by typing AT <enter> and seeing that the modem responds with OK. Enter the following command using Hyper Terminal: AT&F0&M0&B1&N3S69=2&Z0=xxxxxxxDTS13=16&W<enter> The modem will not answer with an OK to this setup string, but if you have made a mistake, it will answer with ERROR. In place of xxxxxxx enter the phone number of the remote site to be called by this modem. Label the modem "Dials xxxxxxx". It is strongly recommended that the modems be tested for operation before locating them to remote sites as described in Section 5 below. You may want to program a temporary "local" dial up number to perform these tests, then reprogram the calling modems to the permanent phone number of the remote site.

Turn the modem power off, and set the DIP switches so that switches 1, 4 and 5 are down (ON) and all other switches are up (OFF). The new settings will take effect when the modem is turned back on. Repeat for all additional calling modems. 4.7 Answering Modem with Dialup Line Locate a modem that will be used at the DF site (the answering unit). Connect it to the PC using the same setup described in section 4.3. Verify that the program is communicating with the modem by typing AT <enter> and seeing that the modem responds with OK. Enter the following command using Hyper Terminal: AT&F0&M0&B1&N3&W<enter>. The modem will answer with an OK. Turn the modem power off, and set the DIP switches so that switches 1 and 4 are down (ON) and all other switches are up (OFF). The new settings will take effect when the modem is turned back on. Repeat for all additional answering (DF site) modems. Note that the setup strings used in both calling and answering modems cause the modems to communicate at 2400 baud at both the serial port and over the telephone line, error checking/correction is disabled, and flow control is also disabled. 5.0 Modem Operation 5.1 Calling Modem to PC Cable You can use the same cable for modem operation as used above for modem programming. However, all that is required is a 3 wire shielded cable that connects the calling modem to the COM port on the PC. Signal PC DB25 (female) pin PC DE9 (female) pin Calling modem DB25 (male) pin TXD 2 3 2 RXD 3 2 3 Ground 7 5 7

5.2 Answering Modem to DDF6000 Cable A 3-wire shielded cable is required that connects the following signals on the answering modem to J1 on the DDF6000. Signal Answering modem DB25 (male) pin DDF6000 J1 (female) pin TXD 3 3 RXD 2 2 Ground 7 5 5.3 Testing the Modems Connect a DDF6000 to an Answering Modem and connect a Calling Modem to the PC. If you have set up the modems for leased line operation, connect the two modems together with a length of telephone cable having RJ11 plugs, such as the short length supplied with the modems. If you have set up the modems for dial up operation, connect them to two separate phone lines with the answering modem connected to the one with the phone number programmed into the sending modem. Use the RJ11 jacks marked "Jack" (closest to the RS232 connectors) on the modems. Turn the modems on. After a few seconds of handshaking the two modems will connect. When this happens, the CD, OH, MR and CS lights on both modems will be lit and the AA light will be lit on the answering modem. Be sure that a plug is inserted in J4 on the DDF6000 to place it in the CIV mode. Turn on the power to the direction finder with the plug installed. To test the network, you do not need to have a receiver or direction finder antenna connected. You can place the direction finder in a "self test" mode by selecting (from the front panel) Sweep = 0, Cal = ON, Sig = 9). The DF should display a bearing. When you finish these tests, you can turn off the self test mode using the same command sequence. Execute BrgTrack on the PC. Check that the proper COM port has been selected (Setup Serial Port), then check that the DF address matches that of the DDF6000 connected. (The default value is 1). Select Setup Site, Enable one site, select Modify, and set the DF-id to the address of the DDF6000. If a CIV receiver is connected to the DDF6000, check that its address also matches that shown in the RX-id field. Select Locate on Map and be sure that the site location is shown somewhere on the screen. If a CIV receiver is not connected to the DF, be sure that no channels are enabled (Setup Channels Disable). Now place BrgTrack in the RUN mode. The RD and SD lights on both modems should blink and the BrgTrack screen should display a bearing.

To verify that the system will restart after a power failure, turn the DDF6000 Off. BrgTrack will display an error message. Turn the DDF6000 back ON then click on "Yes" to restart BrgTrack's polling sequence. Turn off the power on the answering modem. BrgTrack will again display an error message and after brief interval, the CD light on the calling modem will go off. Turn the power back on and wait until the calling modem light returns to on. This may take anywhere from a few seconds with a leased line connection to 15 or more seconds with a dial up line. Now click the "Yes" button to restart BrgTrack. Turn off the power on the calling modem, turn it back on, and wait for the CD light to indicate that the modems have reestablished communication. Restart BrgTrack using the Yes button. If you will be connecting to multiple sites, repeat the above tests using the next modem pair. 5.4 Testing Multiple Modem Connections Before testing multiple modems and DF's you need to set the addresses of each DDF6000 to a unique value using the RDFCMD program provided with the direction finders. Connect a DDF6000 to the PC serial port (using a minimum 3-wire cable), execute RDFCMD, select the proper COM port, select DF serial port J1, select CIV protocol, enter the current CIV address (1 unless you have already changed it), and enter anything for the receiver CIV address. Enter command 0 (Bearing Data Rqst) and verify that the a response message is received. To change the CIV address, enter command 4 from the Main menu to reach the RDF Address Menu, enter the new CIV address, then hit the ESC key twice to exit the program. If you will be using CIV receivers at each site, you need to also set unique addresses on these. Refer to the ICOM receiver manual for instructions on setting the CIV addresses. Connect the female connector on the serial data expander to the PC using the cable provided with it (a six foot 3 conductor shielded DE9 male to DE9 female), and connect the calling modems to the male connectors on the serial data expander. With BrgTrack in its off mode, setup the CIV addresses for the direction finders and receivers at each site to match those connected to the network. Turn all the direction finders and modems on and wait until all the modems are communicating properly as indicated by stable CD indications on the calling modems. Now click on Run in BrgTrack. You should see bearings displayed at each site (assuming that all direction finders are still in the self test mode).

6.0 Timing The following timing diagrams are provided as an aid in case you experience difficulty with communications after setting up the modems. Figure 4 shows the timing obtained using the Courier V.Everything modem on a leased line. Figure 5 illustrates the timing that results when a direct (local) connection is made between the PC and the DDF6000. Figure 4 Figure 5 7.0 Final Installation When all of the modems, direction finders, receivers, serial data expanders and the PC are operating reliably in the same room, you are ready to locate the answering modems, direction finders and receivers to the remote sites. Be sure to note the CIV addresses of the direction finders and the receivers so that they are installed at the correct site location. Also, be sure not to mix up the calling and answering modems. Remember to switch off the self test mode on the direction finders.