Rack mounted telephone- and leased line modem for industrial applications



Similar documents
Telephone- and leased line modem for industrial applications TD-36

User Guide. Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.

User Guide. Westermo Teleindustri AB TD-23. Leased Line V.23 Modem Multidrop applications.

MODEM RS232 <=> RTC<=> RS485 Operating instructions

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide

Waveguide Access Point WGA631. Product Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Quick Connect. quick - simple - efficient.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

38 Series - Relay interface modules A

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

38 Series - Relay interface modules A

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Electronic Control Devices The European Product Catalogue 2007

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

is then retained absolutely without interruption.

PCS0100en Persy Control Services B.V. Netherlands

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

IntesisBox KNX LG Air Conditioning

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

STRATO LED Drivers 70W, Single output

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

Foxboro Evo Process Automation System

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

MasterINTERFACE 39 Series - Relay interface modules

F2400 FOM II Series Fiber Optic Modem Technical Manual

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Electronic Control Devices The European Product Catalogue 2007

Operating Manual UWAPS-TINY Series

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

IntesisBox KNX Modbus RTU master

VOICE RECORDING SYSTEM ISDN PRI / BRI

I STAR COMPUTER CO., LTD

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

IntesisBox Modbus Server Fidelio IP

GSM Voice Auto Dialer & SMS Sender JC-999

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

7.5 Watt AC-DC Switch Power Supply

Power Meter Series 700

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MANUAL PC1000R

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

15 Series - Electronic step relay and dimmer. Features SERIE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Unidirectional Transmitter/ Receiver Units Introduction

PSI-DATA/FAX-MODEM/RS232

TEST REPORT EN (1997) +A1 (2001)

Application/Connection Examples

IntesisBox KNX - LON

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Phase Modular Finally the benefits of Modular ups are for all

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Remote Monitoring and REC 501 Control Unit Product Guide

IntesisBox KNX Modbus TCP master

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Fieldbus slave modules with I/Os, DIO

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Energy Management Energy Meter Type EM23 DIN

KNX Panasonic Air Conditioners

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

MasterINTERFACE 39 Series - Relay interface modules

TK800-Series Industrial GPRS / UMTS / LTE Router

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA / TETRAPOL 400 RF/RF

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

T200, PTP/IEEE 1588 Grandmaster Clock and

NX safety stand-alone

Three-phase monitoring relay CM-PFE

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

HDO700 P FIBRE OPTIC TRANSMITTER

NetScanner System. Toronto: , Montreal: , Toll Free: ,

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cisco Redundant Power System 2300

Loop-IP6702 TDMoEthernet

Transcription:

Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as a industrial /-wire leased line modem. V. provides speeds up to.6kbit/s on the communication line. Several features make it ideal for use in industrial applications: Password protection, dial-back security and caller ID answering are only some of this features. For redundant use, the PSTN dial backup function is useful. In case of a leased line failure, the modem will establish a dial backup link. The modem has both RS- and RS-85/ interfaces allowing it to be used in many different applications. All connections are accessible from the back of the 9 -card. The TR-6 is the ideal choice for industrial dial-up and / wire leased line applications where many modems need to be installed in a small amount of space. Configuration and diagnostics The TR-6 is configurable via its serial interface in different ways, either via standard terminal emulation software using AT-Hayes commands or Westermo s own modem configuration software - TD-Tool. Additionally the TR-6 can be configured via its onboard DIP-switches. TD-Tool is a Windows based configuration GUI that simplifies setting up the modems, connection statistics can be viewed and configurations saved for further use. To assit in fault finding and reconfiguration of unmanned stations, the modem can be configured remotely via a PSTN connection. Harsh industrial environment The TR-6 is designed to function reliably within industrial environments and in areas of high level interference. The modem is equipped with transient protection on the line side and a watchdog that monitors and automatically resets the modem in the event of a fault. The TR-6 is designed to be mounted in Westermo s RV-07 9 rack which can hold up to 7 TR-6 modems. Approvals The construction of the units has gone through extensive testing and approvals both by Westermo and approved test houses. The TR-6 is approved for use in Europe. Industrial PSTN Modems

Application Telephone network Leased Line Interfaces DIP-switches LEDs Jack socket Headphones can be fitted to listen to the line quality. RS-/V. (9-pos. D-sub) Speeds up to 5. kbit/s RS-/85 (screw terminal) Speeds up to 5. kbit/s Line connection, dial-up (screw terminal) Speeds up to.6 kbit/s Power supply on RV-07 PS-0 HV External 8 DC Operating voltage 90 6 VAC / 99 00 VDC 8 VDC Rated current 5 ma @ 6 VDC 90 ma @ VDC (fully equipped rack with 7 modems) Rated frequency 8 6 Hz / DC DC Detachable x -pos. screw terminal Detachable -pos. screw terminal Applications, interfaces

Technical Data Power RV-07, 7 pcs TR-6, PS-0 HV Power supply 0 50 VDC +0 / 0% 5 0 VAC +5 / 0% Power consumption 500/0 ma, 50 W Rated frequency DC / 8 6 Hz Fuse, F AS 5x 0 mm Isolation to All other ports kvrms 50 Hz min * Direction relative this unit Power RV-07, 7 pcs TR-6, ext 8 VDC Power supply 8 VDC Power consumption W Rated frequency DC Isolation to All other ports.5 kvrms 50 Hz min ** * Direction relative this unit ** Maximum wire length to external power supply < 0 m. Public Switched Telephone Network (PSTN) Electrical specification Public Switched Telephone Network 00 bit/s.6 kbit/s B0, B, V, V, VB, VC, V HDX, V, VB, V Protection Installation Fault Tolerant (up to ±60 V) Isolation to Power port kvrms 50 Hz min Leased Line kvrms 50 Hz min RS- kvrms 50 Hz min RS-85 kvrms 50 Hz min I/O kvrms 50 Hz min RJ-C and Connector size

Leased Line (LL) Electrical specification - or -wire Leased Line 00 bit/s.6 kbit/s B0, B, V, V, VB, VC, V HDX, V, VB, V Transmission range PSTN 0 db Budget Leased Line max 0 db Protection Installation Fault Tolerant (up to ± 60 V) Isolation to Power port kvrms 50 Hz min Leased Line kvrms 50 Hz min RS- kvrms 50 Hz min RS-85 kvrms 50 Hz min RS-/85 Electrical specification EIA/TIA-85 ITU V. -wire or -wire twisted pair 00 bit/s 5. kbit/s Data format 7 or 8 data bits, Odd, even or none parity, or stop bits, Σ 9- bit words Transparent Retiming Yes Turn around time <0 µs (half duplex) Transmission range 00 m, depending on data rate and cable type (EIA RS-85) Settings 0 W termination and failsafe biasing 680 W Protection Installation Fault Tolerant (up to ±60 V) Isolation to Power port kvrms 50 Hz min PSTN Line kvrms 50 Hz min Leased Line kvrms 50 Hz min Galvanic connection to RS- Connector size 0..5 mm (AWG ) * Miscellaneous Do not connect RS- and RS-/85 simultaneously

RS- Electrical specification EIA/TIA- 00 bit/s 5. kbit/s Data format 7 or 8 data bits, Odd, even or none parity, or stop bits, Σ 9- bit words Transparent Retiming Yes Transmission range Cable length 5 m Isolation to Power port kvrms 50 Hz min PSTN Line kvrms 50 Hz min Leased Line kvrms 50 Hz min 9-pin D-sub female (DCE) and (DCE ) Connector size 0..5 mm (AWG ) * Conductive housing Isolated to all others circuits Miscellaneous Do not connect RS- and RS-/85 simultaneously * Railway installation close to the rails. For a cable located within m and connected to this port, the use of shielded cable is recommended, this is to minimise the risk of interference. The cable shield should be properly connected (60 ) to an earthing point within m of this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is builtin. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth.

Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Test levels ESD EN 6000-- Enclosure contact ± 6 kv Enclosure air ± 8 kv RF field AM modulated IEC 6000-- Enclosure 0 V/m 80% AM ( khz), 80 000 MHz 0 V/m 80% AM ( khz), 80 000 MHz RF field 900 MHz ENV 500 Enclosure 0 V/m pulse modulated 00 Hz, 900 ± 5 MHz Fast transient EN 6000-- Signal ports ± kv Power ports ± kv Surge EN 6000--5 Signal ports ± kv line to earth, ± kv line to line unbalanced Signal ports balanced ± kv line to earth, ± kv line to line Power ports ± kv line to earth, ± kv line to line RF conducted EN 6000--6 Signal ports 0 V 80% AM ( khz), 0.5 80 MHz Power ports 0 V 80% AM ( khz), 0.5 80 MHz Power frequency magnetic field EN 6000--8 Enclosure 00 A/m, 50 Hz, 6.7 Hz & 0 Hz Pulse magnetic field EN 6000--9 Enclosure 00 A/m, 6. / 6 ms pulse Voltage dips and interruption EN 6000-- AC power ports 0 & 5 000 ms, interruption 0 & 500 ms, 0% reduction 00 & 000 ms, 60% reduction Mains freq. 50 Hz EN 6000--6 Signal ports 00 V 50 Hz line to earth Mains freq. 50 Hz SS 6 5 0 Signal ports 50 V 50 Hz line to line Voltage dips and interruption EN 6000--9 DC power ports 0 & 00 ms, interruption 0 ms, 0% reduction 0 ms, 60% reduction +0% above & 0% below rated voltage Radiated emission EN 550 Enclosure Class B Conducted emission EN 550 AC power ports Class B EN 550 DC power ports Class B Dielectric strength EN 60950 Signal port to other isolated ports kvrms 50 Hz min Power port to other isolated ports kvrms 50 Hz min kvrms 50 Hz min (@ rated power <60 V) Environmental Temperature Operating 0 to +50ºC Storage & Transport 5 to +70ºC Humidity Operating 5 to 95% relative humidity non condensing. Storage & Transport 5 to 95% relative humidity non condensing. Altitude Operating 000 m / 70 kpa Reliability prediction (MTBF) MIL-HDBK- 7F Operating Service life Operating 0 year Packaging Enclosure Dimension W x H x D 85 x 5 x 80 mm Weight TR-6 0. kg Weight Total kg (7 TR-6 + PS-0) Degree of protection IEC 59 Enclosure IP 0 Cooling Convection Mounting 9 rack