Agilent Electronic Crimper and Decapper

Similar documents
FREE SAMPLE PACK Just ask.

Sample Vials and Accessories. [ For all ACQUITY UPLC, HPLC, and GC Systems ]

Vials and Accessories

High pressure reactors Where are your limits?

Samco Scientific Liquid Handling Solutions

GENERAL CHROMATOGRAPHY. Your Essential Resource for Supplies

laboratory glass bottles and screw caps

CataLoG No. weight o.d. i.d. GLaSSwaRe

Syringe Selection Guide

National- Spencer Inc.

CappController Pipette Controller. Operation Manual Version:

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Mitos P-Pump. product datasheet

Your Best Choice For Laboratory Consumables

Corning Storage Bottles Selection and Use Guide

ArtisanLink Staining System is an automated special stains slide

PRECISION LIQUID HANDLING

GC-xt. The most flexible GC /GC-MS liquid sample injector

Tubing. PEEK Tubing. Spiral-Link PEEK Tubing. Fused Silica Tubing

Maintaining Your Agilent LC and LC/MS Systems. Our measure is your success.

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

Multiple flasks. Easy to adapt. Stuart range of heating blocks

GE Wireless Devices Battery Replacement

kymanual or Automatic - it s your Choice

DURAS INFLATABLE BOAT OWNER'S MANUAL

SciTech, sro Praha Ceník Jour Research tisk

Analysis of Liquid Samples on the Agilent GC-MS

Back to School Promotion Offers - consumable (Aug 2014)

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover

In-situ Density Determination by Sand Replacement Method

Density/Specific Gravity/ Concentration Meter DMA 500

Syringes 5. Contents. Autosampler 6. MEPS 18 Product Data 18 Part Numbers 19. Manual 20. Guided Plunger 24 Product Data 24 Part Numbers 25

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

HOSE, TUBE, AND PIPE CLAMPS

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Solids, Volatile Dissolved and Fixed Dissolved

The Safest Heating Method!

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Wolflite Safety Handlamp H-251E

Gas Chromatograph GC Consumables. p/n:

Determination of the enthalpy of combustion using a bomb calorimeter TEC

Omega Pipettor. Operating Instructions

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette!

Lab Exercise 3: Media, incubation, and aseptic technique

3M Dual Lock Reclosable Fastener

ACL 395 Resistivity Meter

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

Vacuum drying oven for non-flammable solvents

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

Gas Chromatography Liner Selection Guide

Scott Batcheller Manager Research & Development. Milwaukee, WI

RUBBER SLEEVE KNIFE GATE VALVE

5-Other arc welding WELDING TOOLS AND ACCESSORIES

Micro Precision Tools Your partner for precision applications

Maintaining your Agilent GC and GC/MS Systems

globe reactions made easy Process perfection

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

ORGANIC SAMPLE PREPARATION

When Completed - Fax to (410)

Pipe Cutting and Beveling Clamshells

Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

Index Syringes. Hamilton Syringes. Hamilton General Information 142. Hamilton Syringes Syringe Needles

Precision Vise Combinations

LCD Readout Digital Pressure Switch

Use of Micropipettes

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Featuring fast rotor exchanges with AUTO-LOCK

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

413 NOVA SYSTEM PAN AMERICAN TOOL CORPORATION 5990 NW PHONE (954) TOLL FREE FAX

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists

Air Compressor Catalogue

With proper calibration, the upper limit may be extended as needed.

TIRE PRESSURE MONITORING SYSTEM

CL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C).

14. Tools and Software

SIMPLAIR PIPING TOOL

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

TERRA TEK LIMITED GUIDE TO SAMPLE HANDLING. Version 1.06

Rheodyne Manual Sample Injector Valves

2 & 5-Wire Overfill Sensors

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

System Accessories Pricing. Page 0 Effective 7/02

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

MOISTURE (Karl Fischer, Buffered)

Determination of Insoluble Solids in Pretreated Biomass March 2008 Material

Transcription:

Agilent Electronic Crimper and Decapper Easy-to-Use The comfortable grip makes the Electronic Crimper and Decapper easy-to-use. Simply place the jaws over the crimp cap and 2mL vial and push the cycle button with your gripping hand until the motor has engaged to cause a full crimping cycle. Within seconds, the useradjustable jaws provide a precision crimp a result that is repeated vial after vial. Works best when used in a seated position or standing at a GC autosampler tray. Weighs less than 1-1/2lbs! Crimps hundreds of crimp top vials per battery charge Consistent and reproducible crimping Settings are saved when not in use Reliable, Reproducible Crimping with the Push of a Button Tired of crimping hundreds of vials with manual crimpers? Tired of losing your samples due to poorly crimped seals? The Agilent Electronic Crimper solves these problems and crimps autosampler crimp top vials with the touch of a button. Using the Black & Decker VersaPak Gold rechargeable battery, this motor-driven, hand-held, high precision tool lets you crimp hundreds of vials per battery charge. Designed to fit your hand, the electronic crimper and decapper allows a comfortable and natural position eliminating the fatiguing wrist and hand motion experienced when using manual, plier-type crimpers. The crimper jaws can be set electronically to the precise level required for reliable and reproducible crimping. The jaws are designed to fit around closely-spaced vials like those in standard vial holders or autosampler trays. The crimping force is set using up-anddown adjustment buttons and is controlled electronically with an internal microcontroller giving you the reliability you need for a gas-tight seal on your samples. The electronic crimper comes complete with the crimper, battery, and battery charger. A spare and/or replacement VersaPak battery is also available. Proven Technology with the VersaPak Gold Battery & Charger Well-known for tool technology Rechargeable within 6-9 hours Ergonomic design reduces fatigue to the hand and wrist associated with using manual plier-type crimpers Power to the Agilent Electronic Crimper is provided by the Black & Decker VersaPak Gold rechargeable battery, the same technology used in other power tools. Based on nickel-metal-hydride (NiMH) technology, the environment-friendly batteries provide consistent power and ability to crimp hundreds of vials with one battery charge. Size: Weight: Body: Jaws: Battery: Voltage: 13cm (L) x 4cm (W) x 18cm (H) w/o battery: 445g, CE Certified w/battery: 595g charger: 290g Glass-filled nylon Carbon steel, electroless nickel plated Black & Decker VersaPak Gold NiMH 3.6 V, Full charge time: 6-9 hrs. Agilent Electronic Crimper and Decapper Agilent electronic crimpers and decappers come complete with one VersaPak Gold rechargeable battery and charger. 5183-4763 Electronic crimper - 11mm 5184-3567 Electronic decapper - 11mm 5184-3572 Electronic crimper - 20mm 5184-3573 Electronic decapper- 20mm 5183-4799 Black and Decker VersaPak Gold NiMH rechargeable battery 332 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com

Head Space CTV-2246 CTV-2246R CTV-2375 CTV-2375R Head Space CTV-2375S 20mL Clear, 23 x 75mm, Head Space vial 100 CTV-2375 20mL Clear, 23 x 75mm, Rounded top/flat bottom 100 CTV-2375R 20mL Clear, 23 x 75mm, Rounded top/rounded bottom 100 CTV-2246S 10mL Clear, 22 x 46mm, Head Space vial 100 CTV-2246 10mL Clear, 22 x 46mm, Rounded top/flat bottom 100 CTV-2246R 10mL Clear, 22 x 46mm, Rounded top/rounded bottom 100 CTV-2238S 6mL Clear, 22 x 38mm, Head Space vial 100 CTV-2238 6mL Clear, 22 x 38mm, Rounded top/flat bottom 100 CTV-3060 27mL Clear, 30 x 60mm, Rounded top/flat bottom, (Shimadzu) 100 Crimp Caps for 20mm 408101 Caps only, for 20mm OD vials 100 414183 Tear out center crimp caps (empty) for 20mm OD vials 100 930107 Crimp cap with pressure release safety feature 100 408077 Crimp cap with Silicone Rubber/PTFE faced septa 100 408234 Crimp cap with Butyl Rubber/PTFE, Gray 100 Septa for 20mm 615020 Silicone Rubber/PTFE faced septa 100 408111 Butyl Rubber/PTFE faced septa 100 224168 Pharma-Fix liner (Use with 930107) 100 Accessories for 20mm 5184-3572 Agilent electronic crimper for 20mm seals 904303 Crimper for 20mm seals 224303 E-Z Crimper, attaches 20mm seals 5184-3573 Agilent electronic decapper for 20mm seals 224353 Hand operated decappers, removes 20mm seals 904373 DeCapping pliers for 20mm seals S Straight Top Rounded Top Pressure Release Lined Seals Special 20mm crimp closures with bridges and scorelines in the aluminum seal. Use these seals when large amounts of volatile solvents are used in headspace analysis. 100 seals/pk 83320P 20mm PR, w/ptfe/silicone 83220P 20mm PR, w/ptfe/gray Butyl molded 83520P 20mm PR, w/pharma-fix liner Magnetic Lined Seals Magnetic lined 20mm headspace seals are required by a number of autosamplers (Carlo Erba HS 500 and 700 and Leap HS 500) which pick up and transport vials by the use of a magnet prior to analysis. 100 seals/pk 83320M 20mm MLS, w/ptfe/silicone 83220M 20mm MLS, w/ptfe/gray Butyl molded 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com 333

Autosampler EPA/VOA Closed Top The Top Hat septa and closure was designed to provide a positive physical lock to assure that preassembled components arrive intact. Preassembled Precleaned Precleaned/Certified Description Qty. Cat. No. Cat. No. Cat. No. 20mL,.125" Septa open top clear vials 72 CTV-1611 CTV-6212 CTV-6213 20mL,.125" Septa open top amber vials 72 CTV-1621 CTV-6222 CTV-6223 20mL, w/top Hat septa, clear vials 72 CTV-1631 CTV-6232 CTV-6233 20mL, w/top Hat septa, amber vials 72 CTV-1641 CTV-6242 CTV-6243 20mL, Closed top clear vials 72 CTV-1651 CTV-6252 CTV-6253 20mL, Closed top amber vials 72 CTV-1661 CTV-6262 CTV-6263 40mL,.125" Septa open top clear vials 72 CTV-6411 CTV-6412 CTV-6413 40mL,.125" Septa open top amber vials 72 CTV-6421 CTV-6422 CTV-6423 40mL, w/top Hat septa, clear vials 72 CTV-6431 CTV-6432 CTV-6433 40mL, w/top Hat septa, amber vials 72 CTV-6441 CTV-6442 CTV-6443 40mL, Closed top clear vials 72 CTV-6451 CTV-6452 CTV-6453 40mL, Closed top amber vials 72 CTV-6461 CTV-6462 CTV-6463 Precleaned Autosampler Precleaned 12 x 32mm Qty. Cat. No. Cat. No. 2mL, Clear, PTFE/Silicone, 8-425 screw cap 100 CTV-7212 CTV-7213 2mL, Clear, PTFE/Silicone, 8-425 Top Hat 100 CTV-7232 CTV-7233 2mL, Clear, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7252 CTV-7253 2mL, Amber, PTFE/Silicone, 8-425 screw cap 100 CTV-7222 CTV-7223 2mL, Amber, PTFE/Silicone, 8-425 Top Hat 100 CTV-7242 CTV-7243 2mL, Amber, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7262 CTV-7263 15 x 45mm 4mL, Clear, PTFE/Silicone, 13-425 screw cap 100 CTV-7412 CTV-7413 4mL, Clear, PTFE/Silicone, 13-425 Top Hat 100 CTV-7432 CTV-7433 4mL, Clear, Snap seal vial, PTFE/Silicone Snap Top Cap 100 CTV-7452 CTV-7453 4mL, Amber, PTFE/Silicone, 13-425 Screw cap 100 CTV-7422 CTV-7423 4mL, Amber, PTFE/Silicone, 13-425 Top Hat 100 CTV-7442 CTV-7443 4mL, Amber, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7462 CTV-7463 Precleaned/Certified Silane Treated Autosampler 12 x 32mm Qty. Cat. No. 2mL, Clear, PTFE/Silicone, 8-425 screw cap 100 CTV-7272 2mL, Amber, PTFE/Silicone, 8-425 screw cap 100 CTV-7282 2mL, Clear, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7292 2mL, Amber, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7202 15 x 45mm Qty. Cat. No. 4mL, Clear, PTFE/Silicone, 13-425 screw cap 100 CTV-7472 4mL, Amber, PTFE/Silicone, 13-425 screw cap 100 CTV-7482 4mL, Clear, Snap seal vial, PTFE/Silicone Snap Top Cap 100 CTV-7492 4mL, Amber, Snap seal, PTFE/Silicone Snap Top Cap 100 CTV-7402 334 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com

Storage, Caps and Seals Open-Top/Solid Top Caps Clear Screw Cap 408213 2mL, 12 x 32mm (8mm cap) 100 404802 4mL, 15 x 45mm (13mm cap) 100 224701 8mL, 17 x 60mm (15mm cap) 200 402024 12mL, 19 x 65mm (15mm cap) 200 224706 16mL, 21 x 70mm (18mm cap) 200 224708 24mL, 27 x 70mm (24mm cap) 200 402027 40mL, 27 x 95mm (24mm cap) 100 Open Top Caps Qty 408010 8mm, Open-top cap 1,000 408032 13mm, Open-top cap 100 531015 15mm, Open-top cap 100 531018 18mm, Open-top cap 100 412044 20mm, Open-top cap 100 531024 24mm, Open-top cap 100 Solid Top Caps 410206-R 8mm, Solid cap, rubber liner 1,000 410208-R 13mm, Solid cap, rubber liner 200 410209-R 15mm, Solid cap, rubber liner 200 410215-R 18mm, Solid cap, rubber liner 500 410216-R 20mm, Solid cap, rubber liner 500 410214-R 24mm, Solid cap, rubber liner 500 410208-T 13mm, Solid cap, PTFE liner 200 410209-T 15mm, Solid cap, PTFE liner 200 410215-T 18mm, Solid cap, PTFE liner 200 410216-T 20mm, Solid cap, PTFE liner 100 410214-T 24mm, Solid cap, PTFE liner 100 535008 8-425 Solid cap, PP, Pulp/PTFE 1,000 536008 8-425 Solid cap, PP, PTFE/F217 100 535010 10-425 Solid cap, PP,PTFE 1,000 535013 13-425 Solid cap, PP, Pulp/PTFE 100 536013 13-425 Solid cap, PP, PTFE/F217 100 Septa 400581 8mm, PTFE faced Silicone 100 408045 13mm, PTFE faced Silicone 100 606515 15mm, PTFE faced Silicone 100 606518 18mm, PTFE faced Silicone 100 615020 20mm, PTFE faced Silicone 100 615024 24mm, PTFE faced Silicone 100 408246 8mm, PTFE faced natural Rubber 100 240594 15mm, PTFE faced natural Rubber 100 240596 20mm, PTFE faced natural Rubber 100 Mobile Phase/Storage Bottles Graduations PTFE lined caps Amber Screw Cap 404810 2mL, 12 x 32mm (8mm cap) 100 404812 4mL, 15 x 45mm (13mm cap) 100 224814 8mL, 17 x 60mm (15mm cap) 100 402034 12mL, 19 x 65mm (15mm cap) 200 CTV-2170 16mL, 21 x 70mm (18mm cap) 144 402037 40mL, 27 x 95mm (24mm cap) 144 219817-1 250mL Graduated bottle w/cap, 33-430 219819-1 500mL Graduated bottle w/cap, 33-430 219919-1 500mL Graduated bottle, no cap, GL45 219820-1 1L Graduated bottle w/cap, 38-430 219940-1 1L Safety coated graduated bottle w/cap, GL-45 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com 335

Storage Bottles Ideal for solvent or sample storage Narrow or wide mouth available Round or square bottles Redi-Pak Glass Boston Round Bottles Unique narrow mouth bottles are ideal for solvent and sample storage. Capacity Dia. x Hgt. Case White PP Cap White PP Cap White PP Cap Black Plastic Cap oz./ml mm (w/o cap) Qty. Poly Vinyl Liner PTFE Liner Rubber Liner Poly-Seal Liner Clear Cat. No. Cat. No. Cat. No. Cat. No. 1/30 31 x 79 48 W216800 W216806 W216818 W216812 2/60 39 x 94 24 W216801 W216807 W216819 W216813 4/125 48 x 112 24 W216802 W216808 W216820 W216814 8/250 60 x 136 12 W216803 W216809 W216821 W216815 16/500 75 x 168 12 W216804 W216810 W216822 W216816 32/1000 94 x 206 12 W216805 W216811 W216823 W216817 Amber 1/30 31 x 79 48 W216836 W216842 W216848 2/60 39 x 94 24 W216837 W216843 W216854 W216849 4/125 48 x 112 24 W216838 W216844 W216855 W216850 8/250 60 x 136 12 W216839 W216845 W216856 W216851 16/500 75 x 168 12 W216840 W216846 W216857 W216852 32/1000 94 x 206 12 W216841 W216847 W216858 W216853 Redi-Pak Clear French Squares These square shaped bottles allow you to maximize storage space in the lab. 0.5/15 26 x 62 48 W216871 W216877 W216883 1/30 31 x 72 48 W216872 W216878 W216884 2/60 39 x 72 48 W216873 W216879 W216885 4/125 45 x 111 24 W216874 W216880 W216886 8/250 56 x 137 24 W216875 W216881 W216887 16/500 68 x 157 24 W216876 W216882 W216888 Redi-Pak Clear Standard Wide Mouth Bottles The largest bottles available in the Redi-Pak line offer a ready-to-use sample storage container. 4/125 52 x 84 24 W216924 W216929 8/250 63 x 110 24 W216925 W216930 16/500 79 x 133 24 W216926 W216931 65/2000 122 x 213 6 W216927 W216932 130/4000 157 x 256 4 W216928 W216933 Redi-Pak AC (Medium) Round Bottles Wheaton (Atlantic City) Rounds have been in use for years. Ideal for use as sample bottles. They are also useful for dry powders, soil samples, and specimen storage. 1/30 34 x 68 48 W216995 W217000 2/60 42 x 83 48 W216996 W217001 4/125 51 x 102 24 W216997 W217002 8/250 68 x 127 24 W216998 W217003 16/500 76 x 145 24 W216999 W217004 336 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com

Reaction and Accessories Mininert Valves for Glassware Leak-tight closure with syringe access take a sample with no exposure of vial contents to atmosphere Economical Replaceable septum Simple installation no tools Operation is extremely simple push the green button to open the valve, insert the needle through the septum and take a sample, withdraw the needle, and push the red button to close the valve. Mininert push-button valves are highly dependable, leak-tight closures for screw cap vials and other laboratory containers. When used with a glass vial, only PTFE and glass are in contact with the contents. Their unique features make Mininert valves the ideal closure for calibration standards, air or moisture sensitive fluids, derivatizing reagents, volatile chemicals, etc. Temperature Specifications: Mininert valves can be used at temperature up to 105 F. However, after use at high temperatures, the valve may leak slightly when cooled to room temperature. Pressure Specifications: The sealing ability of Mininert valves is more than adequate to contain most volatile liquids and gases at low pressures. Mininert valves have been used as high as 120 psi without leakage but this is NOT a recommendation for pressurizing glass containers to these levels. Such pressurization of glass containers can be extremely dangerous. Micro/Reaction Clear Screw Cap Micro, 12/pk Uses Cap & Septa 402000 0.1mL, Conical vial, 12 x 32mm 8mm 402013 0.3mL, Conical vial, 13 x 32mm 13mm 402001 1mL, Conical vial, 13 x 45mm 13mm 402002 3mL, Conical vial, 20 x 47mm 20mm 402003 5mL, Conical vial, 20 x 62mm 20mm Graduated Screw Cap Micro, 12/pk 402005 0.1mL, Conical vial, 12 x 32mm 8mm 402014 0.3mL, Conical vial, 13 x 32mm 13mm 402006 1mL, Conical vial, 13 x 45mm 13mm 402007 3mL, Conical vial, 20 x 47mm 20mm 402008 5mL, Conical vial, 20 x 62mm 20mm Amber Screw Cap Micro, 12/pk 402009 0.1mL, Conical vial, 12 x 32mm 8mm 402015 0.3mL, Conical vial, 13 x 32mm 13mm 402010 1mL, Conical vial, 13 x 45mm 13mm 402011 3mL, Conical vial, 20 x 47mm 20mm 402012 5mL, Conical vial, 20 x 62mm 22mm Caps 408010 8mm, Open-Top cap 1,000 408032 13mm, Open-Top cap 100 412044 20mm, Open-Top cap 100 240517 22mm, Open-Top cap 200 Septa 400581 8mm, PTFE faced Silicone 100 408045 13mm, PTFE faced Silicone 100 615020 20mm, PTFE faced Silicone 100 240587 22mm, PTFE faced Silicone 100 408246 8mm, PTFE faced natural Rubber 100 240596 20mm, PTFE faced natural Rubber 100 Chemical Resistance Specifications: PTFE is highly inert and may be used with most common materials. It is particularly useful for working with most acids and organic solvents. Mininert Ordering Information 614158 Vial valve for 13mm-425 thread 12 614160 Vial valve for 15mm-425 thread 12 614161 Vial valve for 18mm-400 thread 12 614170 Vial valve for 20mm-400 thread 12 614163 Vial valve for 24mm-400 thread 12 614250 Crimp-top valve for 20mm ID * glassware 12 644350 Replacement septa 50 644850 Installation tool 1 * The crimp-top valve for 20mm ID glassware slides into the neck of the vial and features a threaded flange which is turned to secure a tight fit. Magnetic Stirrers 412131 Spin Vane for 0.1-2mL micro vials 6 402013-MS Spin Vane for 3-5mL micro vials 6 1-800-822-5242 in MN 952-431-6000 www.chromtech.com sales@chromtech.com 337