The Safest Heating Method!
|
|
|
- Gordon Flynn
- 10 years ago
- Views:
Transcription
1 ACE Instatherm For Glass Vessels The Safest Heating Method! Borosilicate Glass Eliminate the need for heating tapes, immersion heaters and heating mantles. Instatherm is a safer, more precise heating method for the laboratory. It is an Ace Glass proprietary process that fuses a noble metal alloy coating directly onto the glass surface. Once the insulating and protective covering is applied, the Instatherm electrical circuit provides the most rapid and precise heating method available. Thermal lag is minimal with no hot spots. When placed on a magnetic stirrer, it becomes the best heating and mixing combination on the market. Because Instatherm is a process more than product, it can be adhered to any glass vessel. This brochure features our standard vessels for your convenience. However, custom application inquiries are most welcome. Fused-to-Glass Conductive Heating Film Integral Outer Insulation m r e h t a t ACE Ins confidence th heat wi e eliminate save tim tspots! ho Rapid, even heat low thermal lag No super-heating Suitable for magnetic stirrers Extremely accurate heating More precise than mantles Accommodates variety of vessel sizes and shapes
2 2 ACE INSTATHERM Bath Kit Consists of one each and bath, plus one digital temperature controller with one J type temperature sensor, two clips, and two controller cords. Stand not included ACE Instatherm Oil Bath/Controller Kits For 120v Baths Bath Kit Economy Bath Kits for your convenience Consists of one bath plus one economy temperature controller, one clip, and one type J thermocouple temperature sensor, and controller cord. Stand not included ize For All S Baths Bath Kit Consists of one each , and baths, three clips, three cords, plus one J-Kem digital temperature controller with J type temperature sensor and controller cord. Stand not included Also available with extended 12-foot permanent controller cord baths: ing & Product Information: Subject to Ace Discount Net
3 ACE INSTATHERM 3 ACE temperature controllers are compact, bench- or rack-mountable Programmable, tunable, and adaptable to your needs Digital-Type Temperature Controller Designed Especially For Instatherm The J-Kem Model 410 is designed for heaters that cannot be operated as high as 120VAC, such as some styles of Instatherm oil baths. Maximum output voltage of the Model 410 is selected using the power output knob on the front of the controller. Selectable output voltage limit provides precise power and temperature control while protecting low voltage heaters. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation. Output Power: 10, 20, 40, 60, 120 VAC; Electrical input: 120 VAC, 10 amps, 1200 watts. Size: 3.25H x 5.25W x 7.25D inches; Weight: 3 lbs. Warranty: 1 year J-Kem Model w/sensor Cord and Adapter Temperature Range (ºC) Thermocouple Type 410-T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Economy Temperature Controller Economy temperature controller with J thermocouple input; output power 120 volt/60 Hz, 15 amp maximum. Portable or bar mountable. 120 volt/60 Hz input. Single-loop time proportional output: 10 seconds cycle rate. Solid state relay control contact. Temperature range varies by sensor type. 0.1 C resolution. Accuracy over range: 0.25% (maximum 2 C). Set-point control accuracy: ± 0.1 C. Microprocessor-based 1/32 DIN module, dual process and set-point value display. Auto-tuned PID with fuzzy logic. Programmable: ramp and soak (16 segment). Bath must be 120V compatible. Size: 2H x 5.25W x 5.25D inches; Weight: 2 lbs, 2 oz. Warranty: 3 years Temperature Range (ºC) Thermocouple Type 0 to 800 J to 250 T to 200 K STIRRER, Talboys Advanced Series Talboys Advanced series magnetic stirrer with either a ceramic or aluminum top. Microprocessor controlled with analog speed knob. Speed range rpm. The new low-profile design makes it easier to place under reactors like our Ace photochemical reactor vessels. PTFE stir bar included. Accessory support rod kit available on request. 120v (230v available). CE, UL and CUL approved. Two-year manufacturer s limited warranty. Top Size, In. Capacity, ml Top 4x4 600 Ceramic x4 600 Aluminum x Ceramic x Aluminum approved. Subject to Ace Discount Net ing & Product Information:
4 4 ACE INSTATHERM Ace Instatherm -heated glass oil baths, for use with time-proportional temperature controllers, offer safety and efficiency No exposed-coil heater for greater safety Rapid, even heat with low thermal lag Suitable for magnetic stirrers Low Form Instatherm Baths Allows small mini-lab size flasks to be stirred internally with magnetic stirrer bars while being heated in baths 9601 INSTATHERM OIL BATH, Low Form Low form, glass open vessels coated with Instatherm. Designed to operate up to 250ºC, heating response time is very rapid, (5 per minute), with very low thermal lag. The bottom is uncoated so the bath can be put on any popular magnetic stirrer for stirring while heating. Baths are designed to run with oil or a heating media. Never run Instatherm baths dry or breakage can occur, especially at higher temperatures. Capacity is without a vessel. Three-prong connector plug is designed to work with Ace temperature controllers where the output voltage can be automatically limited to match the bath. Bath can also be matched with ACE temperature thermocouple sensors for complete automatic operation. If using another type temperature controller, voltage should not exceed the rated voltage (see below). Complete item includes clip for sensor and/or thermometer. Integral six-foot controller cord Bath & Cord Complete w/clip Approx. (mm) I.D. x O.D. x Hgt. Capacity, ml 64 x 70 x / x 125 x / x 125 x / x 150 x / x 190 x / INSTATHERM OIL BATH, Large Large version bath that can accept round bottom flask up to 5L and other larger vessels. Bath measure 300mm (11.8 inches) I.D. by 250mm (9.8 inches) deep. The bath has a rolled lip for easy handling. The maximum temperature on this bath is 100 C. The full capacity is 15L without a vessel, and typically should have a minimum of six liters when using a vessel like a 5L round bottom flask. Baths must be run with a heating media or oil. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Complete item includes clip for sensor and/or thermometer Bath & Cord Complete w/clip Approx. (mm) Capacity, I.D. x O.D. x Hgt. Liters 290 x 300 x / INSTATHERM OIL BATH, Low Form The same vessels as listed under 9601 Low Form series except with longer integral cord that is 12 feet in length and is PTFE clad. Complete item includes clip for sensor and/or thermometer. Bath & Cord Complete w/clip Approx. (mm) I.D. x O.D. x Hgt. Capacity, ml 64 x 70 x / x 100 x / x 125 x / x 150 x / x 190 x / ACE Instatherm items are available in special sizes and for special applications. Give us a call! ing & Product Information: Subject to Ace Discount Net
5 ACE INSTATHERM INSTATHERM OIL BATH, High Form High form, heavy walled glass vessels coated with Instatherm to accommodate larger and taller vessels. A thermocouple well is imbedded in the insulation in this series. Do not run baths dry or above max voltage or breakage can occur. Bottom is uncoated so it can be used with or without magnetic stirrers. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Complete item includes clip for sensor and/or thermometer Bath & Cord Complete w/clip Approx. (mm) I.D. x O.D. x Hgt. Takes Flask Size, ml 90 x 100 x / & smaller x 150 x / & smaller x 210 x / & smaller INSTATHERM BEAKER, Griffin Low Form With lip and pouring spout. With silicone rubber treated glass cloth insulation for use up to 250 C. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Approx. (mm) I.D. x O.D. x Hgt. Capacity, ml 64 x 68 x / x 77 x / x 90 x / BATH OIL An extremely stable, medium viscosity silicone oil. Available in two temperature ranges: Low Temp maximum 180 C; or High Temp maximum 230 C. Type Size Low Temp (180 C).9L (1 Qt.) High Temp (230 C).9L (1 Qt.) Type Size Low Temp (180 C) 1.8L (1/2 Gal.) High Temp (230 C) 1.8L (1/2 Gal.) Low temp oil color is CLEAR. High temp oil color is 9698 CONNECTING CONTROLLER CORDS Controller cords with various connectors for connecting all Instatherm vessels to temperature controllers. -16 and -20 cords have 10 amp, fast-acting fuse to protect both vessel and controller from over-voltage or surges. Description Cinch Type Pin Type Banana Type (old style) Twist Lock Type (new style) CLIPS, for Thermocouple or Thermometer Description For Bath Series Small clip with one hole Medium clip with two different sized holes All other baths Medium clip with two 1/4-inch holes All other baths Large clip with two 1/4-inch holes Extra large clip with two 1/4-inch holes Subject to Ace Discount Net ing & Product Information:
6 6 ACE INSTATHERM 9610 INSTATHERM FUNNEL, Addition Graduated addition funnel with Instatherm coating for critical heating. The funnel has a bottom inner standard taper joint and an outer joint on top. The funnel can be hooked to an Ace temperature controller and heated for liquefying solids or keeping liquids at a set temperature for addition to system or a reactor. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord Capacity, ml TS Joints Stopcock /5 24/ /6 24/ /10 24/ /10 29/42-24/ INSTATHERM DESICCATOR, Vacuum Oven 250mm diameter with bottom Instatherm heated (low voltage: 40 volts, 10 amps maximum). Top is not heated, but has insulation cover. May be used as a vacuum oven continuously at temperatures up to 180ºC. The top has an observation stripe for visibility and is supplied with vacuum take-off valve. Insulation is resilient silicone rubber impregnated glass cloth, and electrical connections are covered. Temperatures can be regulated by means of Ace temperature controllers. Also available with uncoated top. Supplied complete with detachable cord, for 250ºC operation, 102mm immersion 10/30 ground joint thermometer, and thermometer adapter. Desiccator Thermometer Adapter Complete and supplied with controller cord INSTATHERM FLASK, High Temp Type, Single Neck Distilling, round bottom with TS24/40 joint. With silicone rubber treated glass cloth insulation for use up to 250 C. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Cap., ml / / INSTATHERM FLASK, Erlenmeyer Ace Erlenmeyer flask with Instatherm provide a convenient, safe heating of contents in the popular Erlenmeyer flask format for bench or magnetic stirrer use. For operation up to 250 C. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Capacity, ml / / / ing & Product Information: Subject to Ace Discount Net
7 ACE INSTATHERM INSTATHERM FLASK, High Temp, Three Necks Distilling, round bottom with three TS24/40 joints. With silicone rubber treated glass cloth insulation for use up to 250 C. No clamp needed. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Capacity, ml / / / INSTATHERM FILTER REACTOR, Unjacketed Rugged, heavy-wall reactor, Instatherm coated for safer, rapid heating. Flange at top has shallow O-ring groove, for connection to 6527, 6528, 6529 or 6533 heads, with 6517 quick release clamp. Bottom has a #50 or #80 Ace-Thred (internal glass thread) for installing or bottom adapter with filter support and drain valve. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Cap., ml Flange I.D., mm (in.) Bottom Thread Size Body I.D., mm Approx. Depth, mm Replacement CAPFE O-ring Volts Amps Watts (2.4) # (2.4) # (4) # (4) # (6) # (6) # INSTATHERM REACTION FLASK Rugged cylindrical reaction flask with Schott, flat, ground 4-inch flange with O-ring groove for use with quick release clamp and integral heating element that eliminates the local superheating commonly associated with more conventional heating methods and eliminates cumbersome oil baths. The response is rapid and accurate. Supplied with silicone coating for insulation and protection. O-ring (supplied with flask) is CAPFE (PTFE encapsulated silicone). Flask is coated to within approximately 38mm of the flange for 250 C operation. Interchangeable with all Ace reactor heads. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. Cap., ml Watts / / Clamp, only INSTATHERM REACTION FLASK Same flask as listed under 6476, except with Instatherm. Has flat-ground, 4-inch conical flange. This integral heating element eliminates the local super-heating commonly associated with more conventional heating methods. Eliminates cumbersome and dangerous oil baths. The response is rapid and accurate. Supplied with cord for connection to variable voltage or temperature controller. Flask is coated to within 38mm of the flange for 200ºC operation, 360 C maximum on special order. Interchangeable with all Ace 4-inch reaction heads. For controllers, see Ace or J-Kem temperature controllers with voltage limiting output, such as 12125, Use 6496 clamp for securing head to flask Cap., ml Watts / / Subject to Ace Discount Net ing & Product Information:
8 8 ACE INSTATHERM INSTATHERM FILTRATION FUNNEL, 47mm This 47mm filtration funnel uses Ace Glass proprietary Instatherm technology to evenly heat viscous materials, keeping them in a flowing, liquid state. Excellent for filtering oils or thick slurries using either 47mm membranes or filter paper disks. Perfect for sample prep for various ASTM petroleum and polymer testing procedures and for new biofuel testing protocols. Three-pronged plug for insertion into Ace temperature controllers. Integral six-foot controller cord. For the complete filtration apparatus, see our Laboratory Glassware & Equipment Catalog. Description 500mL Instatherm coated filter funnel w/temp controller connecting cord COMPLETE INSTATHERM /BLOCK SYSTEM A combination of two great ideas: the best and most accurate way of heating combined with the our new Dynabloc technology. Instatherm baths now available with newly engineered aluminum Dynablocs that fit into the bath body and hold popular size vials and tubes. Just use your existing 1,200 ml bath and block for precise heating or place the entire unit on any magnetic stirrer to combine stirring with Instatherm heat. Use existing equipment or buy a complete system Complete System (contains all items listed below) Description Aluminum Block for 16mm Tubes Economy Temperature Controller, 120v with J Type Thermocouple Troemner Magnetic Stirrer (7 x 7 inches) inch Aluminum Rod ,200 ml Instatherm bath, complete with clip INSTATHERM BLOCKS Individual Ace Dynablocs for use in Instatherm baths. Block diameter (141mm) is for use in the ,200mL Instatherm bath. Description Block Height For 22, 2 Dr./8mL or 17 mm O.D. vials 30.8mm For 14, 4 Dr./16mL or 22mm O.D. vials 38.8mm For 24, 16mm O.D. tubes 50mm For 8, 40mL or 28mm O.D. vials 50mm Accessory T-Handle Extractor (fits all Ace Dynablocs) For a complete listing of ACE temperature sensors, see our Laboratory Glassware & Equipment Catalog. P.O. Box 688 Vineland, NJ Fax: TOLL-FREE: FAX: [email protected]
Multiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers
Magnetic Stirrers Patented RET control-visc with white coated heating plate! > Offers excellent chemical resistance > Easy to clean RET controlvisc kg Integrated temperature sensor for precise temperature
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
Solids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly
RET control-visc The Magnetic Stirrer for Scientists Phil S. Baran Ph.D. Recipient of MacArthur Genius Grant Baran uses IKA equipment designed to work perfectly RET control-visc Safety. Power. Intelligence.
CataLoG No. weight o.d. i.d. GLaSSwaRe
Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources
PROVISIONAL The Source for Calibration Professionals Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources The NEW Advanced Range of Portable Temperature Calibrators Advanced Range Isotech
High pressure reactors Where are your limits?
Laboratory equipment High pressure reactors Where are your limits? Modern high pressure reactors need to be technically safe, reliable, economical in use and simple to operate. With Berghof quality and
Temperature Control for Research and Industry. Model 210 & 210/Timer Manual
Temperature Control for Research and Industry Model 210 & 210/Timer Manual Warranty J-KEM Scientific, Inc. warrants this unit to be free of defects in materials and workmanship and to give satisfactory
Precision Vise Combinations
Precision Vise Combinations PanaVise vises and work holding tools have hundreds of uses limited only by your imagination! Each vise allows the head to Tilt, Turn & Rotate and position your work anywhere
Specials. www.ika-apparatuur.nl. designed. 3rd edition 2015 English. for scientists 1
Specials www.ika-apparatuur.nl 3rd edition 2015 English designed for scientists 1 IKA Specials Quarterly Campaign III Three is a charm With over 100 years of experience, IKA continues to strive for delivering
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
List of instruments required for Innovation Projects sanctioned in Deshbandhu College for the year 2015-16
Fresh quotations in sealed envelope are invited addressed to The Principle, Deshbandhu College, for the purchase of equipment required for Innovation Project 2015-16 Closing date is 15 November, 2015 List
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Product Price List - June 2012! Drosophila Activity Monitoring System. TriKinetics Inc 56 Emerson Road Waltham, MA 02451 USA 781-891-6110
Product Price List - June 2012! Drosophila Activity Monitoring System Product Price List 1/7 June 2012 TriKinetics Inc 56 Emerson Road Waltham, MA 02451 USA 781-891-6110 1986-2012 Product Price List -
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
DENSITY MEASURING SYSTEMS
SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon
TechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug
Sharp, adjustable depth contact tip to penetrate corrosion or metal coatings for a good connection. Limited Lifetime warranty. 1) Universal Magnetic Ground Lug Stop searching for a good place to clip your
Custom Cable Assemblies for Medical Applications and more.
Custom Cable Assemblies for Medical Applications and more. National Cable Molding is one of the United States premier suppliers of custom molded electrical assemblies for medical applications. Our capability
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Homogenizer with Direct Controller. Digital Homogenizer with Remote Controller. Homogenizing Stirrer, for use with Tissue Grinders.
- Useful for All Dispersing and Homogenizing Applications - High Speed / High Quality / Low Noise : Max. 27.000 RPM (without load) - Speed & Power Control Optimized for a Sample - High Efficiency Dispersing
Unmatched Metal Hardness Testing
Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
Calibration of Volumetric Glassware
Chemistry 119: Experiment 2 Calibration of Volumetric Glassware For making accurate measurements in analytical procedures, next in importance to the balance is volumetric equipment. In this section volumetric
BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES BATHS
BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES BATHS WATER BATH FOR FULL VISIBILITY OF SAMPLES WB-Series, For Full Visibility Of Samples WBS-14 14 Liter Low-cost fully compatible substitute
450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
WATERBATHS AND OILBATHS
WATERBATHS AND OILBATHS New bath generation, still more accurate through innovative control technology Combined start delay and hold time; on Excellent models setpoint-dependent More security through at
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
EasyTrack 2 Accessories List
EasyTrack 2 Accessories List DATA LOGGER ET6061 EasyTrack2 Data Logger (6 Channel) Measurement Range -150 to 500 C (-238 F to 932 F) Accuracy ±0.5 C (0.9 F). Type K thermocouple. 6000 readings per channel.
Fixtures - Parts - Accessories to shampoo bowls
Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,
Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.
Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the
SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS
ADVANTAGE PLUS SITE REQUIREMENTS SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS 50096-927 Rev A For additional information contact your Medivators Pg 1 of 18 SITE REQUIREMENTS The purpose of this section
Digital Hotplate. Stirrers. Compact & Round Plate Type Hotplate Stirrers. Analog Hotplate Stirrer. Digital Hotplate
- Smart Design of Body made by Aluminum Die-Casting - -Chemical/Acid Resistance - Superior Temperature Uniformity : Less than 10% on the at Ambient Temperature - User s Self -Compensation Function : to
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
FALEX Four-Ball Extreme Pressure Test Machine
FALEX Four-Ball Extreme Pressure Test Machine The Four-Ball EP Test measures a lubricant s extreme pressure properties under High Hertzian contact in pure sliding, or pure rolling, motion. The test is
Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers
LUBRIZOL TEST PROCEDURE TP-N01004 Edition: December 2, 2013 Previous Editions: August 10, 2000 / November 1, 2011 Determination of Viscosity Using A Brookfield Scope A material's flow property is an important
GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work
GE Lighting Solutions Albeo LED Luminaire Modular High & Low Bay Lighting (ABHX - Series) imagination at work Product Features The award winning Albeo ABHX-series LED Luminaire utilizes innovative heat-sinking
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
Autoclave Engineers. Laboratory Stirred Reactors. Stirred Reactors
Autoclave Engineers Laboratory Stirred Reactors Stirred Reactors Stirred Reactors Autoclave Engineers has been associated with excellence in pressurized reaction equipment for over 50 years. Autoclave
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,
DISSOLVED OXYGEN PROBE
51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe
Multifunction HVAC and IAQ Meter
testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature, humidity, air flow and more! cfm P CO 2 %RH F Lux All the right parameters for HVAC and IAQ The testo 435 is perfect
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
MILESTONE. RotoSYNTH. Rotative Solid-Phase Microwave Reactor
MILESTONE H E L P I N G C H E M I S T S RotoSYNTH Rotative Solid-Phase Microwave Reactor RotoSYNTH benefits The benefits of microwave-enhanced synthesis Microwave enhanced chemistry represents a fundamental
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.
600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure StarTech ID: SAT3540U3ER The SAT3540U3ER 4-Drive USB 3.0/eSATA to 3.5" SATA RAID Enclosure is a high-performance external RAID storage
Pipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
Laboratory Autoclave SN210/310/510,SQ510/810
1/5 Laboratory Autoclave SN210/310/510,SQ510/810 SN210/310/510,SQ510/810 The highest temperature of 135deg.C Upwards opening lid SN210 SN310 SN510 Effective Capacity : 20LEffective Capacity : 32L Effective
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.
Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help
Back to School Promotion Offers - consumable (Aug 2014)
Back to School Promotion Offers - consumable (Aug 2014) Valid till 30 th November, 2014 Beakers Beaker, Borosilicate glass, low form Code Cap. Price Promotional Price UR-C15720-0005 5ml HKD $7/pc HKD $63/
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
RayClic Connection System Installation Instructions
RayClic Connection System Installation Instructions Description RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit These kits are for use with Raychem IceStop, XL-Trace
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
RayClic Connection System Installation Instructions
F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment
Porcelain Vessel Sink Installation
Porcelain Vessel Sink Installation Required Supplies & Tools A. One of these two type of Faucets Threaded Faucet Nut & Bolt Faucet B. Under Counter Supply/Drain Lines & Shutoff Valves Water Supply Lines
Electric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
User Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION Applications THE WIDE RANGE OF USING CERTOCLAV AUTOCLAVES MICROBIOLOGY / BIO-CHEMISTRY Autoclave culture mediums Refuse sterilisation Efficiently
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Lighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
Generator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Technical Support Information No. 113 Revision 2.0 March 2005
Process Instrumentation and Analytics - A&D PI 2 - Karlsruhe Page 1 of 16 Neues PECM ersetzt alle PECM s in Maxum und Maxum Edition II - New PECM replaces all PECMs in Maxum and Maxum Edition II General
Mixtures and Pure Substances
Unit 2 Mixtures and Pure Substances Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances. They