Emergency Stop Switches A Technical Guide for Proper Selection

Similar documents
Emergency Stop Push Buttons

EAO Your Expert Partner for Human Machine Interfaces. Semiconductor and Electronics Production. HMI Systems and Components

Series. Catalogue.

Understanding Emergency Power Off (EPO)

Trends in Machinery/ Automation Safety

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

Control and Signaling Units

Switches and Indicators. Swisstac

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR

EAO Your Expert Partner for Human Machine Interfaces. EAO Product Information. Series 84

ETZGAR CONVEYOR COMPANY Controls Section v12.05

section 5 machine guarding and lockout

Communication & Networking

General 1-2-Opto-electronics Safety Switches 4-Emergency

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

CONTROL OF HAZARDOUS ENERGY (Lockout Tagout)

Mini USB and USB 2.0-IP67 Connector System

Cross-beam scanning system to detect slim objects. 100 mm in

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

INTEL S SAFETY WARNING LABEL REQUIREMENTS

Phone: Fax: Web: info@clrwtr.com

Pilot and Signaling Devices. Section 9. Control Catalog 9-1

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Machine Safety Switches

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

Technical Information

INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA TOLL FREE: (877) FAX: (781)

Medium voltage VCP-W MR2 (integral racking)

Safety Manual For Overhead Crane Operators

ACCUMULATOR INSTALLATION

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Product and functional description

VOYAGER 570G. 744A Sprayer Control

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Vertical integration and high technical expertise

SMS 4 / SMS 5 safety mat Product information

Pendant control stations 6

Operating Instructions Drill rig DRU160

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Cable Plug acc. to DIN EN , Form A

Vilter motor starter solutions The NEW industry standard in motor starter packages

DC400 Dispensing Cutoff System

SYSTEM 4C. C R H Electronics Design

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Oil and Coolant Circulating Heating System. Model - OCSM

DLP-PU/E Instruction Manual

AMPSEAL* Automotive Plug Connector and Header Assembly

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

I STAR COMPUTER CO., LTD

Control blocks for two-hand start ZSB

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

WE-350 Series ¼ Turn Electric Actuator

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

EAO Your Expert Partner for Human Machine Interfaces. EAO Product Information. Series 1K2

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Thermal-Magnetic Circuit Breaker M1-..

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

STANDARD PRACTICE INSTRUCTION

How To Drive A Compact Serie 1

7000 Series Buccaneer

TOP RUNNING SINGLE GIRDER BRIDGE CRANE

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

LOCKOUT/TAGOUT PROGRAM ENERGY CONTROL PLAN

R.C.C.B. s two-pole LEXIC

Mazda CX

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

9 Control Equipment. Control Button Series 8082

E-STOP relays, safety gate monitors

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Waterproof Connectors for Outdoor Use

Explosion proof enclosures

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Safety Manual BT50(T) Safety relay / Expansion relay

aseries A13B Mini Bullet Camera User Manual

SYSTEM 45. C R H Electronics Design

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

AXIS T81B22 DC 30W Midspan

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Conventional Fire Detection and Extinguishant Control System Specification

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Manual Switches Series 2 Pushbutton Switches and Indicators

Transcription:

Technical Article Emergency Stop Switches A Technical Guide for Proper Selection Emergency stop switches, generally referred to as E-Stops, ensure the safety of persons and machinery and provide a consistent, predictable, failsafe control response. A wide range of electrical machinery must have these specialised switch controls for emergency shutdown to meet workplace safety and established international and U.S. regulatory requirements. E-Stops critical human machine interface (HMI) devices differ from simple stop switches (that merely turn equipment off) in that they offer foolproof equipment shutdown. This is accomplished through advanced switch design that requires a twist, pull, or key to release electrical contacts to allow machinery restart. E-Stops are generally designed for failsafe operation so the stop command has priority over the sustaining function. This has led to innovative switch designs that prevent blocking (wanton or accidental obstruction of the actuator with foreign objects) and teasing (which could result in premature or unreliable action). Switch companies also are developing new solutions to problems that arise when contact block and actuator are improperly installed or separated because of vibration or other malfunction. Safe emergency stopping According to international standards, the emergency stop function must be initiated by a single human action using a manually actuated control device. The E-Stop function must be operational at all times and designed to stop the machine without creating additional hazards. Resetting the electrical system can only be done by first releasing the E-Stop that was originally activated. If E-Stops were activated at multiple locations, all must be released before machinery E-Stops are critical to the human machine interface (HMI). restart. It should be noted that resetting E-Stops does not in itself restart the machinery; it only permits restarting through normal procedures appropriate for the machinery involved. Ergonomic, electrical, mechanical, and colour requirements for E-Stops are quite specific. The E-Stop control, commonly a distinctive pushbutton switch or mushroom type pushbutton (although wires, ropes, bars, handles, or foot pedals are sometimes employed), must use direct www.eao.com

Figure 1 Parts of an E-Stop Not all stop E-Stops are made the same. Designers need to have a thorough knowledge of E-Stop fundamentals, E-Stop switch characteristics and capabilities, and the international and U.S. standards and compliance requirements. Actuators can be teaseproof, twist-to-release, and foolproof in design. E-Stops typically offer a range of contact options including gold over silver or silver over palladium, and silver-plated screw terminals with available quick-connect terminals. 1 2 Figure 1 Parts of an E-Stop EMERGENCY-STOP PUSHBUTTON ACTUATOR Actuators should be precision molded from high quality polymeric materials to assure a mechanical life in excess of 6,050 operations as required by industry standards, including EN IEC 60947 5-5, paragraph 7.3.3. In real life, E-Stops generally exceed 250,000 operations. Actuators can be teaseproof, twist-to-release, and foolproof in design. Actuators can also be pushbutton, mushroom, or key release. SEALING Many E-Stops are sealed to IP 65 oil and watertight standards. 3 FRONT PLATE Front plates can be designed to conform to color and legend standards. 4 FIXING NUT E-Stops have a variety of mounting options, for use in 22.5 mm or 16 mm panel openings. 5 SWITCHING ELEMENT E-Stops typically offer a range of contact options including gold over silver or silver over palladium, and silver-plated screw terminals with available quick-connect terminals. www.eao.com. 2

E-Stops are required on all machinery independent of the type of energy used to control the function, except for machines in which an E-Stop function would not lessen the risk. Equipment designers must also consider a range of other safety functions. One of the first steps is determining where the E-Stop fits within your machine control system. Check what international and U.S. standards, performance ratings, and codes apply for your application. vehicles may differ significantly from those used on process machinery or medical equipment and will be governed by different regulatory bodies specific to those segments. Regulatory bodies may also specify size, colour, legend, contact terminals, etc. E-Stops may require shorter behind-panel depth. mechanical action with mechanical latching. When the E-Stop is activated (pushed), it permanently opens the electrical contacts through a latching mechanism. To close the electrical contacts and allow machinery restart, the E-Stop actuator must be manually unlatched with a twist or a key release. Some E-Stop actuators can simply be pulled to close the electrical contacts. This approach may be less desirable from a safety standpoint than a twist or key release, which requires a more deliberate action by an operator. Selecting the right E-Stop for your application Because of the confusing array of E-Stops available, it is important to understand the design basics that contribute to high-quality, ergonomic switch design. EAO is a leader in HMI Components and Systems, including innovative, rugged, reliable, and affordable E-Stops that meet or exceed international and U.S. standards. One of the first steps is determining where the E-Stop fits within your machine control system and whether your particular application requires Category 0 or Category 1 type emergency shutdown. The intended application often determines the placement, size, electrical specifications, mechanical characteristics, ergonomics, colour/legends, and number of E-Stops required. So a thorough understanding of the machinery and associated control systems is key to making the right E-Stop choice. A second, and equally important step, is determining what international and U.S. standards, performance ratings, and codes apply for your application. Requirements vary by industry segment, so standards for E-Stops used on transportation It is then useful to construct or consult an existing E-Stop series selector chart (often supplied by vendors). For example, EAO provides a chart that allows easy comparison of key design factors (see Figure 2). You can select panel opening size, type of actuator, type and number of contact blocks, connectors, colours, and maximum electrical rating to come up with one or more appropriate models. Like many vendors, EAO provides special enclosures, switch guards, palm guards, custom labelling, and other accessories to complete virtually any E-Stop application. Some accessories may be specified by industry standards, such as the SEMI standards for semiconductor fabrication equipment that mandate the use of palm guards. EAO and other vendors also offer services to assist customers in the design, engineering, and production of HMI Systems, integrating E-Stops. Designed for rough duty Robust, heavy-duty construction is the hallmark of the original 22.5 mm switches. Many, like the EAO Series 04 www.eao.com. 3

E-Stops are covered by standards and regulations of the FDA Department of Health and Human Services. The key document is CFR Title 21, Part 1020 Performance Standards for Ionizing Radiation Emitting Products, S. 40. Virtually all industry segments from machinery, instrumentation, medical treatment and diagnostic, lifting/ moving, and transportation mandate E-Stops for safe operation. Modern applications often demand a slimmed down E-Stop with 16mm mounting. Illuminated E-Stop used in medical diagnostic treatment. E-Stops, have stackable contact blocks, optional key release actuators, and mounting options for 22.5 mm panel openings. This EAO series is rated at up to 10 A, 600 VAC, has silver contacts with available gold over silver or silver over palladium contacts, and silver-plated screw terminals with available quick-connect terminals. Smaller mounting footprint Modern applications often demand a slimmed down E-Stop with 16mm mounting. Innovative products, like the EAO Series 61, are now available with an actuator shape that prevents blockage from foreign objects, a black indicator ring visible from long distances, and available key release actuators. This EAO series is rated at 5 A, 250 VAC, and has a choice of silver or gold contacts, screw or solder quick-connect terminals. Short behind-panel depth Newer electronic applications are requiring E-Stops with shorter behind-panel depth. EAO s Series 84 E-Stop, for example, features a very short behind-panel depth (18 mm maximum), single mono-block construction, 22.5 mm mounting, and available LED illumination that is visible from the side as well as front of the actuator. This series is rated at 3A, 120VAC and 1.5A, 240VAC, has gold contacts, quick-connect/solder printed circuit board terminals, and ribbon cable terminals. Applications Virtually all industry segments from machinery, instrumentation, medical treatment and diagnostic, lifting/ moving, and transportation mandate E-Stops for safe operation. Designers need to have a thorough knowledge of E-Stop fundamentals, E-Stop switch characteristics and capabilities, and the international and U.S. standards and compliance requirements that apply to their application areas. E-Stops are required on all machinery independent of the type of energy used to control the function, except for machines in which an E-Stop function would not lessen the risk. An E-Stop switch is intended to be one part of a comprehensive safety system, so the equipment designer must also consider safety Figure 2 - Key Design Factors 22.5 mm panel opening 16 mm panel opening ISO 13850 (formerly EN418) Tease-Proof actuator Stackable contact blocks/elements Short behind-panel depth (18 mm max) Illumination Cap colour other than red Screw terminals Quick-connect/ solder terminals Ribbon cable terminals Sealed to IP 65 oil and watertight standards Twist-to-release actuator Key-release actuator Enclosure Legend plates Protective shroud Max rating: 10 A/600 VAC Max rating: 10 A/660 VAC Max rating: 5 A/250 VAC Max rating: 3 A/250 VAC www.eao.com. 4

The pace of change in E-Stop technology is steady, not revolutionary. Established standards, function, and familiarity dictate a certain beneficial inertia in new E-Stop developments. E-Stops are required on all machinery independent of the type of energy used to control the function, except for machines in which an E-Stop function would not lessen the risk. Designers need to have a thorough knowledge of E-Stop fundamentals. General Color of actuator Actuator/Background Inscription of actuator Electrical requirements Utilization categories Emergency Stop Actuators of emergency switching off devices shall be colored RED. EN IEC 60947-5-5 4.2.1 EN 60204-1 10.8.3 DIN EN ISO 13850 4.4.5 When a background exists behind the actuator, and as far as it is practicable, it shall be colored yellow. EN IEC 60947-5-5, 4.2.1 EN 60204-1, 10.8.3 DIN EN ISO 13850 4.4.5 The direction of unlatching shall be clearly identified when resetting is achieved by rotation of the button. EN IEC 60947-5-5 4.2.1 The utilization categories shall be AC-15 and/or DC-13 and/or DC-14 in accordance with EN 60947-5-1. EN IEC 60947-5-5 5.1 Stop Switch Direct opening action Latching Resetting Resetting Testing Robustness of a button activator Durability test Norms Mandatory standards All normally closed contact elements of an emergency stop device shall have a direct opening action (positive opening action). EN IEC 60947-5-5 5.2 It shall not be possible for the emergency stop device to latch-in without generating the emergency stop signal. EN IEC 60947-5-5 6.2.1 Resetting of the emergency stop shall only be possible as the result of a manual action at the location where the emergency stop was initiated. EN ISO 13850, 4.4.4 The resetting of the latching means shall be by turning a key, by rotation of the button in the designated direction, or by a pulling motion. EN IEC 60947-5-5 6.3.1 A button actuator shall withstand a torque as specified below, in both directions of latched actuator and unlatched positions, where the resetting action requires rotation of the push-button. EN IEC 60947-5-5 7.3.2 Ø Force Torque 16 mm 80 N 1.6 Nm 22 mm 110 N 2.2 Nm 30 mm 150 N 3.0 Nm The test shall consist of 6,050 cycles in which latching and resetting of the actuator occurs during each cycle.the movement and actuating forces shall be consistent throughout the test. Monitoring of these parameters shall be carried out to ensure consistency. EN IEC 60947-5-5 7.3.3 EN IEC60947-5-5 (International Standard) EN ISO 13850 (Safety of Machinery) EN 60204-1 (Safety of Machinery) Not necessary, but usually realized by turning a key, by rotation of the button in the designated direction, or by a pulling motion. functions such as reversal or limitation of motion, deflection, shielding, braking, or disconnecting, that are not specifically addressed in this paper. Primary application areas where electrical machinery is safeguarded with E-Stop technology include: Metalworking Wood production Textile production Food processing Printing Medical laser & x-ray equipment Packaging equipment Semi-fab equipment Pumping Lifting/moving equipment Plastics & rubber processing Materials handling www.eao.com. 5

E-Stops will continue to evolve to meet new standards and new applications. For designers, the most important considerations in making the right design decisions are a thorough understanding of E-Stop functions, and a grounding in the standards, codes, and compliances. SEMI S2-93 makes a clear distinction between emergency off (EMO) switches and E-Stops. Depending on design and application requirements, many E-Stops are listed as UL category NISD emergency stop devices. Electronic production equipment Paper & cardboard production Inspection/testing equipment Compressors Laundry/dry cleaning facilities Transportation Construction/building materials X-ray equipment Cabinet x-ray systems used for diagnostic and therapeutic medical applications, industrial non-destructive inspection and thickness gauging, security inspection of baggage, and other imaging are closely regulated for operational safety. E-Stops are covered by standards and regulations of the FDA Department of Health and Human Services. The key document is CFR Title 21, Part 1020 Performance Standards for Ionizing Radiation Emitting Products, section 40, which requires accessible emergency stop switches and keyed lock-out switches to disable the system. Semiconductor manufacturing Semiconductor chips used in electrical and electronic devices are fabricated through a sequence of photographic and chemical processing steps. The process includes lithography, steppers, etching, and deposition equipment. The complex process is governed by specific operational and safety guidelines set down by SEMI, a trade organization of suppliers of equipment and materials used in the fabrication of semiconductor devices. SEMI S2-93 makes a clear distinction between emergency off (EMO) switches and E-Stops, requiring the latter to be clearly distinguishable from EMOs through the use of colour (red), actuator shape (extended not mushroom), and labelling ( Emergency Stop ). It also specifies that E-Stops should stop all hazardous mechanical motion at the equipment interface, but not shut off associated equipment. Overhead and gantry cranes These large lifting and moving devices may have a gantry mounted cab which includes an E-Stop on the operator console. Smaller overhead cranes usually have a wired or wireless pendant control operated from ground level. The pendant includes an E-Stop. The chief regulating body for these massive devices is the Occupational Safety and Health Administration. OSHA 29 CFR 1910.179 (a)(59) defines emergency stop switch as a manually or automatically operated electric switch to cut off electric power independent of the regular operating controls. Another section, 9 CFR 1910.179(a)(61) defines main switch as a device controlling the entire power supply to the crane. U.S. standards for E-Stops Occupational Safety and Health Administration (OSHA) Standards 29 CFR (Code of Federal Regulations); OSHA 1910 American National Standards Institute (ANSI) B11, Electrical and Mechanical Equipment Guidelines ANSI/NFPA (National Fire Protection Association) 79, Electrical Standards for Industrial Machinery Underwriters Laboratories Inc. (UL) Category NISD, Emergency Stop Device Food and Drug Administration, Department of Health and Human Services, Subchapter J Radiological Health: CRF Title 21, Part 1020, Performance Standards for Ionizing Radiation Emitting Products Other compliance and rating bodies Most quality E-Stop switches, including those made by EAO, are RoHS and REACH compliant, meet cul (Canadian UL) requirements, and TÜV (Technischer Überwachungsverein, a German safety monitoring agency), SEV (a Swiss designation) and CE (European Union) approvals. Depending on design and application requirements, many E-Stops are listed as UL category NISD emergency stop devices. This rating covers two categories of E-Stop function as defined in ANSI/NFPA 79, Electrical Standards for Industrial Machinery (ANSI is the American National Standards Institute and NFPA is the National Fire Protection Association): Stop Category 0 Immediate removal of www.eao.com. 6

E-Stops will continue to evolve to meet new standards and new applications. For designers, the most important considerations in making the right design decisions are a thorough understanding of E-Stop function. Contact EAO AG Tannwaldstrasse 88 CH-4601 Olten, Switzerland Tel. +41 62 286 91 11 Fax +41 62 296 21 62 info@eao.com More information www.eao.com/downloads power to the machine or mechanical disconnection (de-clutching) of hazardous elements. Stop Category 1 Controlled stop with power available to stop the machine followed by removal of power when the stop is achieved. The emergency stop actuator provided in these devices must be a self-latching type. E-Stops with this rating have been reviewed for their functionality in addition to fire and electric shock safety. Future of the technology The pace of change in E-Stop technology is steady, not revolutionary. By their nature, these devices must be recognizable, reliable, and rugged. They have a straightforward function: instantly shut down equipment with a simple push of a (usually) bright red actuator. For safety, reactivation of the switch requires twisting or pulling the actuator by hand or, for even more security, unlocking it with a key before machinery can be restarted. Established standards, function, and familiarity dictate a certain beneficial inertia in new E-Stop developments. Many advances are driven by norm changes for E-Stops, such as DIN EN ISO 13850: 2008 that now requires mechanical latching and manual resetting of E-Stops. Most research and development is aimed at improving the safety and reliability of the switchesthemselves and expanding their roles as lockout devices in some worker safety applications. One area of current interest is making sure that the E-Stop itself will failsafe should the actuator and contact block be separated. The contact block has normally closed contacts that allow power to flow to the machinery. Pushing an E-Stop separates the spring-loaded contacts, and mechanical latching keeps them open, stopping the machinery. But what happens if the actuator separates from the contact block or the latching mechanism fails? Separation of the contact block from the actuator renders an E-Stop ineffective. Current solutions include mono-block or unibody switches with a one-piece actuator/contact block, as well as switches with failsafe contact blocks that automatically cause machinery shutdown if the actuator and contact block are separated. Other advances are application-driven. EAO s Series 84 E-Stops, for example, were developed for hand-held enclosures with slim behind-panel depth for robotics applications. These versatile E-Stops also are used in pendant controls for lifting and moving machinery. Application requirements have also created a wide variety of available optional features and accessories for most E-Stop products illumination, protective rings, enclosures, guards, legend plates, etc. that add to the functionality and safety of E-Stop installations. E-Stops will continue to evolve to meet new standards and new applications. For designers, the most important considerations in making the right design decisions are a thorough understanding of E-Stop function; a grounding in the standards, codes, and compliances involved; and proper selection of devices that meet or exceed the application requirements. www.eao.com. 7