Technical specification. MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay

Similar documents
Flygt 3068, 50Hz. Technical Specification

Flygt Aquaview SCADA Software. Safer monitoring and simpler at a glance

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

WD-AMX Water Detection Controllers

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

*.ppt 11/2/ :48 PM 1

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

GSM HOME SECURITY SYSTEM

TMS TANK MANAGEMENT SYSTEM

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Modular I/O System Analog and Digital Interface Modules

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Speed Control Relays SX2

E-STOP relays, safety gate monitors

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

SMS 4 / SMS 5 safety mat Product information

Data Sheet. Electro-mechanical counters Hengstler 800 series

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

OPERATING INSTRUCTIONS

Solid-State Timer H3G

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Preset Counter signo 721

GSM Smart Switch USER GUIDE

PNOZsigma - Base units

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

MS41-22Ex0-R/24VDC MS41-22Ex0-R/115VAC MS41-22Ex0-R/230VAC

User s Manual Before using the inverter, you need to read and save the safety instructions.

Thyristor-controlled power supplies and battery chargers

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

ACS-30-EU-EMDR-10-MOD

Technical Information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Installation and maintenance instructions. Danfoss Vent

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Make full use of equipment

SKR - industry relay

Circuit Breakers. NRC Series. NRC Series

TROUBLESHOOTING ABS DIAGNOSTIC CODES L20293, Rev. 1/13

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DALI RC BASIC SO. Control unit Operating instructions

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Power Supplies 3. SDN-P DIN Rail Series

E-STOP relays, safety gate monitors

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Fire Pump Controllers Remote Alarm Panels

instabus KNX / EIB System System E F G H

IO-RM3 3-Stage Relay Module

LED - Indicator Panels

UM-X Field display for continous level sensors

E-STOP relays, safety gate monitors

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

E-STOP relays, safety gate monitors

Centro-Matic Automatic Lubrication Systems System Controls

Inductive Proximity Sensors

I STAR COMPUTER CO., LTD

DLP-PU/E Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DC LOAD TESTING Gian Trento June 18 th, 2004

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Electronic, Digital and Mechanical Vibration Switches

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

GST301. (Single Protection Zone) Operation Manual

Telefon (+45) Telefax (+45) Installation and operating manual

COLOR VIDEO DOOR PHONE CDV-71BE/D

Process Alarm Solutions

RM4TG20 three-phase network control relay RM4-T - range V

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

J TB/TW Temperature limiter, temperature monitor

Product and functional description

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Technical Information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

DUCT SMOKE DETECTOR D4120

Transcription:

Technical specification MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay

Table of Contents Table of Contents TECHNICAL DATA... 2 Technical data...2 MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay Technical specification 1

TECHNICAL DATA TECHNICAL DATA Technical data Xylem Flygt MiniCAS II is a supervision relay for temperature and leakage sensors. It is designed for the 3000 series pumps up to model 3301 and for the mixer program. A number of condition monitoring sensors are available for the Xylem FLYGT pump range. Thermal switches for stator overtemperature. CLS for water in oil detection. FLS for detection of liquid in the stator housing. FLS10 for detection of liquid in the inspection chamber in the new midrange pump series, eg 3153, 3171, 3202 and 3301. The sensors can be used in any desired combination. For "Ex" certified pumps only combinations involving thermal switches, FLS and FLS10 may be used. On the front, there are three indication lamps, one for supply, one for temperature alarm and one for leakage alarm. For the communication between the pump and the MiniCAS II, only two wires are needed. The MiniCAS II is designed to be connected to a standard 11- pin socket. MiniCAS II is interchangeable with the original version of MiniCAS. Operational principle: Approvals: Environment: Supply voltage 24 VAC/DC: Supply voltage 120 VAC: Supply voltage 230 VAC: Relay contact rating: Current Sensing CE, C-UR (covering USA and Canada) and CSA -25 to +60 C. maximum 90% relative humidity 24 VAC, -17% +25% (50-60Hz) 24 VDC, -2% +25% 120 VAC, -15% +15% (50-60 Hz) 230 VAC, -15% +15% (50-60 Hz) 250 VAC / 5A Voltage to sensor: 12 V DC +/ 5% Values of operation: Power supply required: 3 ma < I < 22 ma = OK condition I < 3 ma = High Temperature (or interruption) I > 22 ma = Leakage (or short circuit), delay 10 sec. (I = current measured by MiniCAS II) 5 VA OPERATION Leakage: Changeover contacts 11 8 Normally closed for Interlock 11 9 Normally open, closes for Alarm Automatic reset Red LED for indication follows the relay Red indication lamp on: Leakage 2 MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay Technical specification

TECHNICAL DATA Red indication lamp off: No leakage Temperature: Changeover contacts 1 3 Normally open, closes for Interlock 1 4 Normally closed for Alarm Manual reset (see below) Red Indication lamp on: Red Indication lamp off: Overtemperature Normal temperature Reset of temperature alarm: External reset is possible either by connecting terminals 6-7 with an external push button or by interrupting the supply voltage. Note, in the 24 V version, Reset is also possible between 6-2. Supply: Yellow indication lamp on: Supply on Yellow indication lamp off: Supply off DIMENSIONS (WxHxD) PART NOS: 33 mm x 79 mm x 75 mm 83 58 57 (24 VAC/DC) 40 501098 (120 VAC) 40 501560 (230 VAC) CONNECTIONS Leakage alarm will stop the pump This installation can be used if the leakage alarm shall stop the pump. It is recommended if the FLS sensor is used. The FLS is detecting liquid in the stator housing, which is critical and requires a quick stop of the pump. ~ (+) POWER SUPPLY 24 V AC/DC 120 V AC and 230 V AC ~ (-) 2 10 MiniCASII T1 SENSORS T2 CONTROL CIRCUIT RESET I (ma) * 1 kohm (+) 6 7 5 1 + 12 VDC - HIGH TEMP 4 3 Circuits Cicuits shown de-energised de-energized HIGH STATOR TEMP. 11 LEAKAGE 10 S 9 8 AUX. RELAY LEAKAGE ALARM PUMP CONTACTOR PUMP MAIN SUPPLY ~ *) Fit resistor to avoid short circuit if only thermal contacts are Figure 1 Note, in the 24 V version RESET is also possible between 6-2. Leakage alarm will not stop the pump (only warning) MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay Technical specification 3

TECHNICAL DATA This installation can be used if the leakage alarm shall not stop the pump but give a warning on the MiniCASII. It is recommended if FLS10 in inspection chamber or CLS is used. These sensors detect liquid in the inspection chamber (FLS10) and water in the oil (CLS), which is less critical than water in the stator housing. FLS10 is used in the new midrange pump series, eg 3153, 3171, 3202 and 3301. (+) POWER SUPPLY 24 V AC/DC 120 V AC and 230 V AC (-) 2 10 MiniCASII RESET 6 SENSORS T1 T2 * 1 kohm 7 5 + 12 VDC - Circuits shown de-energised de-energized 11 LEAKAGE 9 LEAKAGE ALARM 8 10 S CONTROL CIRCUIT (+) 1 HIGH TEMP 4 3 AUX. RELAY HIGH STATOR TEMP. PUMP CONTACTOR PUMP MAIN SUPPLY *) Fit resistor to avoid short circuit if only thermal contacts are Figure 2 4 MiniCAS II, 24 VAC/DC, 120 VAC and 230 VAC Supervision relay Technical specification

Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,000 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Water Solutions AB Gesällvägen 33 174 87 Sundbyberg Sweden Tel. +46-8-475 60 00 Fax +46-8-475 69 00 http://tpi.xyleminc.com Visit our Web site for the latest version of this document and more information The original instruction is in English. All non-english instructions are translations of the original instruction. 2011 Xylem Inc 892533_11.1_en.GB_2012-01_TS_MINICAS-II