ManDown Sensor User Manual

Similar documents
IS76 Beacon with Ferrite Antenna Installation Manual

REMOTE TERMOMETER TE 219 LED USER MANUAL

2-Way Wireless Indoor Siren Installation Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Tele Radio Panther SAFETY instructions

Memory Modules User Guide

MIC-WKT and MIC-WKT-IR

4.3-inch Back-Up Camera

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Business/ Home GSM Alarm System

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Tele Radio T60 INSTALLATION INSTRUCTIONS MHz. LANGUAGE: ENGLISH (ORIGINAL)

End user instructions

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

Automatic Phone-Out Home Monitoring Systems

Nokia Bluetooth Headset BH-607. Issue 2. 1

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

IN-OUT Thermometer with Cable Free Sensor and Clock

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

Nokia Bluetooth Headset BH /1

BSCAN DW VOX SAVE BEEP CHANNEL CALL VOX

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Stove Guard Kit User Manual

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

Nokia Bluetooth Headset BH-104

WIRELESS WATER LEAK DETECTOR

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

ES-CAM2AU IP Camera.

StorTrends 3400 Hardware Guide for Onsite Support

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

LG Wireless Remote Controller

DIGITAL ALARM CLOCK RADIO

Drayton Digistat +2RF/+3RF

ES-CAM3A Outdoor IP Camera

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

CS848E Receiver for 868GEN2 Devices Installation Sheet

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Home Security Alarm System

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

HANDS-FREE BLUETOOTH CONTROLLER for SMART READY TABLETS AND COMPUTERS

User manual DC Safelog. Edition

Manual. Solar Fountain Mobile Phone Charger

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Ultrasonic Distance Meter. Operation Manual

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

EM6625 e-domotica Push Button

EX 2000/EX 2000 C/ GD 2000/GDP

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Remote Engine Start System User s Information Manual

Replacing the Gateway M675 Keyboard

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

Nokia Bluetooth Headset BH-109

MagIC Installation Manual. Point of Sales Terminals TD06014B

Wireless Indoor/ Outdoor Thermometer

WIRELESS HOME ALARM SYSTEM (WHA1)

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Instructions for Use Anti-theft alarm DWA 6

GSM Alarm System User Manual

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Volvo On Call. Owners Manual. Web Edition

ES-CAM2A IP Camera.

19 LED Tube Controller ORDERCODE 41003

Replacing the Gateway M320 Keyboard

Telis 4 Soliris RTS Operating and installation guide Ref A

Business/Home GSM Alarm System. Installation and User Manual

Nokia Bluetooth Headset BH-101. Issue 1

Operating Manual Remote Cost Control Monitor

UniStream CPU-for-Panel

ST815 Illumination Sensor with LCD

Wireless Alarm system s manual

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Hard disk drive mounting bracket Instruction Manual

24 Wide Screen LED Monitor with HDMI

MOBILE CALL GSM Alarm System User s Manual

AMAX 2100 / 3000 / en User Guide

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Installation and User s Manual Global Tracking and Tracing System. GTTS-2000Bi

Wireless Powerlink II Receiver Set Active

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

V COMPACT ALARM SYSTEMS

Water Tank Level Monitor

Nokia Bluetooth Headset BH-118 User Guide

User Guide. Model: MAS-WA-SYS

HWS100 Wireless Home Security System

Using your LED Plus keypad

Single Day Alarm Clock with. Bluetooth and USB Play-through

LED Security Spotlight User Manual

Nokia Bluetooth Headset BH-102. Issue 1

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Transcription:

User Manual Document 953.64c

Document No 953.64c ManDown Sensor User Manual Edition: August 2009 Author: TeleAlarm TeleAlarm SA 2009 All rights reserved. TeleAlarm SA reserves the right to make changes to information contained in this document at any time without prior notice. Great care has been given to the contents of this document. However TeleAlarm SA cannot be held liable for the consequences of any errors or omissions contained herein or for consequential or incidental damages incurred as a result of acting on information contained in the document. TeleAlarm SA Bosch Group Administration, R&D and Aftersale Rue du Pont 23 CH-2300 la Chaux-de-Fonds Switzerland Phone +41 (0)32 911 11 11 Fax +41 (0)32 911 11 00 www.telealarm.com Bosch Sicherheitssysteme GmbH Haus-ServiceRuf Ingersheimer Straße 16 D-70499 Stuttgart Germany Phone 0711 3653 1000 Fax 0711 811 5125 294 Haus-Service.Ruf@de.bosch.com www.bosch-sicherheitsprodukte.de Bosch Security Systems France Atlantic 361 361, avenue du Général de Gaulle F-92147 Clamart France Phone + 33 (0)825 12 8000 (0,15 TTC/Min) Fax + 33 (0)820 900 960 (0,12 TTC/Min) fr.securitysystems@bosch.com www.boschsecurity.fr Bosch Security Systems nv/sa Torkonjestraat 21F B-8510 Marke Belgium Phone +32 (0)56 20 02 40 Fax +32 (0)56 20 26 75 be.securitysystems@bosch.com www.boschsecurity.be Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UB9 5HN United Kingdom Phone 01895-878088 Fax 01895-878089 uk.securitysystems@bosch.com www.boschsecurity.co.uk Bosch Security Systems BV Postbus 80002 NL-5600 JB Eindhoven Netherlands Phone +31 40 25 77 200 Fax +31 40 25 77 202 nl.securitysystems@bosch.com www.boschsecurity.nl Bosch Security Systems AB Vestagatan 2 SE-416 64 Göteborg Sweden Phone +46 (0)31 722 5300 Fax +46 (0)31 722 5340 se.securitysystems@bosch.com www.boschsecurity.se User Manual 953.64c Bosch Security Systems Page 3

Table of Contents 1. Introduction 5 2. Description 5 3. Compatibility of the ManDown Sensor with Social alarm systems 6 4. Operating 6 4.1. Starting the sensor 6 4.2. Turning off the sensor 6 4.3. Detection mode 7 4.4. Repeating the alarm 7 4.5. Deactivating the help call button and the pre-alarm 7 5. Programming the ManDown Sensor 8 6. Maintenance 8 6.1. Safety instructions 8 6.2. Storage 8 6.3. Replacing the battery 9 7. Technical Specifications 10 8. Certification 11 User Manual 953.64c Bosch Security Systems Page 4

1. Introduction The ManDown Sensor has a built-in tilt device, which can detect if the person holding it is in a horizontal position, such as lying on the floor. The sensor will automatically send an alarm when its position corresponds to horizontality after a certain time. Pressing its central bed button will activate a help call at any time. It can be held, for instance, as a necklace by an elderly person or as a safety device by a lone worker in a hazardous environment. The ManDown Sensor will be part of a social alarm system. It can be associated with a Carephone receiver, linked to a social alarm call center through the telephone line, or with a NurseCall system. Help call button LED Fig. 1 ManDown Sensor 2. Description The ManDown Sensor can be delivered with an operational frequency of 434 MHz or 869 MHz. It is equipped with a LED indicator that will flash every ten seconds to show that the sensor is active. This LED indicator will flash green if the battery is ok or red if the battery is low. Pushing the central red button will send a help call to the social alarm system, followed by a short beeping sound. Caution! A help call is sent only after the central red button has been released. The user should be aware that pressing the central red button must be short. If the central red button is being pressed longer that five seconds, the sensor will be turned off, and no help call will be sent. See chapter 4.2. Turning off the sensor. User Manual 953.64c Bosch Security Systems Page 5

3. Compatibility of the ManDown Sensor with Social alarm systems The different types of ManDown Sensors should always be associated with a corresponding social alarm system, according to the following table. Type of ManDown Sensor Social alarm system ManDown 869 MHz, Bosch RF protocol Carephones 3050, 3100, 50, 52, 52+ ManDown 869 MHz, TeleAlarm protocol Carephones 10 & 12 ManDown 434 MHz, TeleAlarm protocol All TeleAlarm NurseCall systems 4. Operating 4.1. Starting the sensor When the ManDown Sensor is off, the user only has to press the central red button to turn it on. A slow beeping sound will then confirm that the sensor is active. Notice! No help call transmission will take place during this operation. 4.2. Turning off the sensor Press the button for about five seconds A beeping sound is emitted during two seconds During these two seconds, release the button and press it a second time, The sensor is then turned off This last step will be confirmed by a slow beeping sound It is always possible to turn off the sensor, even when the help call button is deactivated. Notice! A help call will be activated only after pressing the help call button for less the five seconds and releasing the central red button. This means that during the procedure of turning off the sensor, no alarm will be generated. If the central red button is being pressed and released less that five seconds or pressed longer than seven seconds, a help call will be generated. See chapter 2 Description. User Manual 953.64c Bosch Security Systems Page 6

4.3. Detection mode Detection by the ManDown Sensor can be decomposed into two periods of time. 1) Tilt Detection When the sensor detects a tilt of more than 60 degrees, it will start its internal chronometer for approximately ten seconds. If the sensor comes back to a vertical position within these ten seconds, the chronometer is reset. 2) Pre-Alarm If the sensor does not come back to a vertical position within ten seconds, a pre-alarm starts accompanied by a beeping sound. This period of time is factory-set and lasts approximately thirty seconds. The pre-alarm is cancelled if the sensor comes back to a vertical position or if the help call button is pressed. This pre-alarm may be suppressed by making a solder bridge. See Fig.2. Interior view of a ManDown Sensor. 4.4. Repeating the alarm After a fall, as long as the sensor detects a horizontal position, the alarm will repeat itself after an average period of time of two minutes and thirty seconds. 4.5. Deactivating the help call button and the pre-alarm Making a solder bridge allows to deactivate the help call button or to suppress the pre-alarm. In this case, during the automatic tilt alarm, the sensor remains silent. During all help calls made by pressing the button, the sensor will always issue a beeping sound. No bridge: with pre-alarm Bridged: without pre-alarm Fig. 2. Interior view of a ManDown Sensor No bridge: help call button activated Bridged: help call button deactivated User Manual 953.64c Bosch Security Systems Page 7

5. Programming the ManDown Sensor To program a ManDown Sensor within a Carephone social alarm system (e.g. Carephones 10, 12, 3050, 3100, 50, 52, 52+) or within a NurseCall system, follow the procedure described for the system you are using. As the ManDown Sensor can be considered as a standard transmitter, the system will recognize it during the programming step. Please refer to the manual of the corresponding social alarm system. 6. Maintenance 6.1. Safety instructions Caution! There is a danger of explosion if the replacement of the battery is not performed correctly! Replace the battery only by an identical or equivalent type. Dispose of the used batteries at an appropriate recycling facility. Although battery replacement may be done by non-specialized personnel, the manufacturer recommends that it should be performed by your local dealer. Caution! The ManDown Sensor contains highly sensitive electronic components. It should always be opened in an ESD (Electro Static Discharge) protected environment, with respect to the following precautions: Discharge yourself from electrostatic loads by touching a grounded conductive surface before opening the unit. Avoid touching conductive parts and metallic surfaces if not absolutely necessary. 6.2. Storage Short term storage (less than two weeks) Deactivate the sensor. Long term storage (more than two weeks) Remove the battery and store the ManDown Sensor protected from direct sunlight, moisture and dust. User Manual 953.64c Bosch Security Systems Page 8

6.3. Replacing the battery Necessary tool for opening the sensor case: Jeweler s Screwdriver 2.9mm Turn off the ManDown Sensor. See chapter 4.2. Turning off the sensor. Unscrew the four screws of the case, as shown in Fig. 3. Bottom view of the ManDown Sensor. Carefully remove the compression foam, as well as the used battery. Replace the new battery; ensure that it is in the correct position. Carefully place the compression foam as shown in Fig. 4. Opening the ManDown Sensor. Close the case with the four screws. The arrows show the screws of the transmitter case Fig. 3. Bottom view of the ManDown Sensor Notice! To avoid deteriorating the inserts, do not force the screwing. VARTA battery 3V CR1/2AA Compression foam Fig. 4. Opening the ManDown Sensor User Manual 953.64c Bosch Security Systems Page 9

7. Technical Specifications Dimensions Frequency Tilt sensor Pre-alarm Battery Consumption Battery lifetime 75mm x 40mm x 23mm 434Mhz and 869Mhz Mercury-free type with activating at a 60 angle with vertical 10 seconds of detection, followed by 30 seconds of signal before automatic activation. VARTA 3V CR1/2AA or equivalent (Lithium 3.0V, diam.14.5mm x 25mm) < 5 µa if the ManDown Sensor is deactivated. < 13 µa if the ManDown Sensor is on stand-by from six months to two years, depending on operation and the number of detections performed Type of plastic ABS Cycolac GPM5500S white 25020 with fire classification UL 94 HB User Manual 953.64c Bosch Security Systems Page 10

8. Certification User Manual 953.64c Bosch Security Systems Page 11

User Manual 953.64c Bosch Security Systems Page 12

User Manual 953.64c Bosch Security Systems Page 13