ENGINEERING COMMITTEE Construction and Maintenance Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Similar documents
ENGINEERING COMMITTEE Construction and Maintenance Subcommittee

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE

CADDSTAR V7.0 FEATURES AND FUNCTIONALITY

AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur

What s News in Tax Analysis That Matters from Washington National Tax

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

SECTION 2 TECHNICAL DESCRIPTION OF BPL SYSTEMS

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

F Male DBS Connector Dimensional and Performance Specification

TEL: +44 (0) FAX: +44 (0)

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Management of Converging Networks

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

AUSTAR Multi Dwelling Unit Installation Guidelines 2008

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

Guidelines for Fiber Optic Cable Permits

FTTH ARCHITECTURE WHITE PAPER SERIES

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

How To Design An Outside Plant (Osp) Network Design

IsumaTV connexion to COOP cable system Set up manual

AMERICAN NATIONAL STANDARD

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

Model GS Port Node 1 GHz with 40/52 MHz split

How To Define Hfc Technology

Broadband 101: Installation and Testing

Telecommunications, Networks, and Wireless Computing

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Cisco SFP Optics for Gigabit Ethernet Applications

Embedded FM/TV Antenna System

10-3. SYSTEM TESTING AND DOCUMENTATION

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

DOCSIS 3.1. High Level Overview at NANOG 59. Karthik Sundaresan, Lead Architect. Oct 09, Cable Television Laboratories, Inc.

SATELLITE MASTER ANTENNA TELEVISION SYSTEM


Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Cisco Integrated 4G Low-profile Outdoor Saucer Antenna (ANT-4G-SR-OUT-TNC)

SATELLITE TV on fiber

Leveraging Embedded Fiber Optic Infrastructures for Scalable Broadband Services

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Scope: Communications and Electronic Systems addressed in this section include:

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

Objectives. Lecture 4. How do computers communicate? How do computers communicate? Local asynchronous communication. How do computers communicate?

The road and the buildings on each side of the road can

Pole Attachment Guidelines and Procedures Revision September 2015

Broadband Telecommunications Drop Amplifier

Cable Network Overview. Presented by: Ma1 Schmi1 (CableLabs)

FTTP OSP Design to Maximize Coverage and Upgradeability

PRO 5000 CPE 1D Quick Installation Guide

Questions Regarding Proposed Utility Undergrounding in Kensington

[ Fiber Optics ] [ Voice & Data Networks ] [ Underground Construction ] [ Engineering ] [ Emergency Fiber Optic Restoration ]

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

Copyright. Transport networks. Physical layer Transport and access networks. Pag. 1

E-Option Multi-taps Conditioning at the Tap

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)

Technical Guidance and Testing Procedure for Static and Dynamic Demand Response and Battery Storage Providers of Frequency Balancing Services

On Cables and Connections A discussion by Dr. J. Kramer

CAN/ULC-S Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

Business Customer Demarcation Information

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

Fibre Channel Fiber-to-Fiber Media Converters

Network Design. Yiannos Mylonas

Broadband Technology Clinic. Burlington Telecom Advisory Board

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Ultra High-Speed SONET Fiber-Optic Transmission System

INFOCOMM DEVELOPMENT AUTHORITY OF SINGAPORE CODE OF PRACTICE FOR THE PROVISIONING OF COAXIAL CABLE HOME NETWORKING SOLUTIONS

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

CX380X Advanced Spectrum and Burst QAM Analyzer

IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So!

3M xdsl Line Conditioners 3620

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

AC and DC Drive System Installation Information

Digital Active Indoor Antenna SRT ANT 10 ECO

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

APC series overview. Copyright 2014 Deliberant LLC

STATE TAX COMMISSION OF MISSOURI ASSESSOR MANUAL

Byonics Micro Trak 1000 High Altitude Balloon Tracker

Cellular Wireless Antennas

Transcription:

ENGINEERING COMMITTEE Construction and Maintenance Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 87-1 2008 Graphic Symbols For Cable Systems Part 1: HFC Symbols

NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability and ultimately the long term reliability of broadband communications facilities. These documents shall not in any way preclude any member or nonmember of SCTE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE members, whether used domestically or internationally. SCTE assumes no obligations or liability whatsoever to any party who may adopt the Standards. Such adopting party assumes all risks associated with adoption of these Standards, and accepts full responsibility for any damage and/or claims arising from the adoption of such Standards. Attention is called to the possibility that implementation of this standard may require the use of subject matter covered by patent rights. By publication of this standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE shall not be responsible for identifying patents for which a license may be required or for conducting inquiries into the legal validity or scope of those patents that are brought to its attention. Patent holders who believe that they hold patents which are essential to the implementation of this standard have been requested to provide information about those patents and any related licensing terms and conditions. Any such declarations made before or after publication of this document are available on the SCTE web site at http://www.scte.org. All Rights Reserved Society of Cable Telecommunications Engineers, Inc. 2008 140 Philips Road Exton, PA 19341 i

TABLE OF CONTENTS Introduction...1 1. Poles...2 2. Cable Support Elements...3 3. Anchoring and Guying...3 4. Miscellaneous Symbols...4 5. Underground Designations...4 6. House Drop Designations...5 7. Make Ready or Pole Line Preparation...5 8. Amplifiers...6 9. Splitting Devices...6 10. Powering Devices...7 11. Line Devices...7 12. Subscriber Taps...8 13. Line Terminators...8 14. Signal Processing Locations...9 15. Coaxial Cables...9 16. Optical Devices...10 17. Optical Splice Symbols...11 18. Miscellaneous Optical Symbols...11 19. Data Blocks...12 20. End of Line Blocks...12 21. Wireless Devices...13 22. FTTX Symbols...14 ii

GRAPHIC SYMBOLS FOR CABLE SYSTEMS Introduction Basic Considerations The symbols for devices do not indicate types or model numbers of any manufacturer. They represent the function of the device operated within a cable system. The symbols permit easy addition of model or type numbers within or near their outline. If such model or type designations are used, an explanation of these designations should be placed on a legend sheet for the drawing on which the symbols appear. Proposed Drafting Practices The orientation of a symbol on a drawing, including a mirror image presentation, does not alter the meaning of the symbol. Line width does not affect the meaning of a symbol. In specific cases, a wider line may be used for emphasis. Generally, lines must be made sufficiently wide to avoid loss of resolution during photocopy reduction. Symbols shown in this text are in the approximate correct size and proportion. This relationship should be maintained as nearly as possible on any particular drawing regardless of the symbol scale. Symbols may be drawn to any proportional size that suits a particular drawing, depending upon reduction or enlargement anticipated. If essential for purposes of contrast, some symbols may be drawn relatively smaller than the other symbols on a drawing. The Standard recommends the use of no more than two sizes on a given drawing. For simplification or clarification of a drawing, parts of a symbol for devices, such as amplifiers, may be separated. If this is done, suitable designations to show proper correlation of the parts must be provided. The Symbols Due to the necessary crowding of symbols onto cable system mapping and grid diagrams, some symbols are structured differently than those used in electrical and electronic diagrams. 1

1. POLES POWER POLE TELEPHONE POLE JOINT USAGE (power and telephone pole) CABLE SYSTEMS POLE CONCRETE POLE C STEEL POLE S FIBER REINFORCED POLE F POWER TRANSFORMER POLE JOINT USE WITH POWER TRANSFORMER POWER TRANSFORMER PLATFORM TRANSMISSION LINE CONTACT OTHER SUPPORTING TYPE STRUCTURES Show approximate structure outline or a portion thereof in this manner. RISER POLE Use of a number indicates vertical distance from aerial connection to ground level. R20 R DROP POLE D Add "DP" by any pole DP In this section, riser and drop poles are shown as joint use because this occurs most frequently. Unless otherwise specified, the standard considers wooden poles. The Standard states that unless otherwise specified on drawings or referenced documents, pole usage and ownership are the same. For modification, a designation may be shown adjacent to the pole symbol. 2

TENSION STRAND SLACK SPAN STRAND 2. CABLE SUPPORT ELEMENTS EXTENSION ARM (used by cable systems) MID-SPAN CROSSOVER 100' 20' 100' 120' In this section, poles are shown as joint because this occurs most frequently. the pole it is bracing. OVERHEAD GUY POLE-TO-POLE GUY DOWN GUY WITH ANCHOR " " symbol added to anchor symbol indicates "Set Anchor" Existing cable system anchor - Set cable system anchor - 3. ANCHORING AND GUYING PUSH BRACE To show a push brace, the support pole is a smaller symbol. It shall be drawn in its actual supporting location relative to SIDEWALK DOWN GUY WITH ANCHOR " " symbol added to anchor symbol indicates "Set Anchor" Existing cable system anchor - Set cable system anchor - TREE GUY ROCK GUY BUILDING GUY In this section, poles are shown as joint use because this occurs most frequently. 3

4. MISCELLANEOUS SYMBOLS BOND B GROUND LOCKBOX In this section, poles are shown as joint use because this occurs most frequently. 5. UNDERGROUND DESIGNATIONS UNDERGROUND ROUTING DIRECT BURIED CONDUIT ROUTING PEDESTAL MANHOLE M MH VAULT " " = Optional user defined attribute V HANDHOLE " " = Optional user defined attribute H ROAD BORE (solid portion with slashes) Tick marks represent length dividers. 100' 50' 100' EXISTING POWER TRANSFORMER 4

6. HOUSE DROP DESIGNATIONS HOUSE COUNT The numeral indicates the number of actual house drops at this location. The numeral on top indicates number of actual drops. The numeral on bottom indicates number of potential house drops. MULTIPLE DWELLING UNITS The numeral indicates the number of dwelling units. INSTITUTIONAL BUILDING (school, church, police, fire, etc.) Designated appropriately as to the type of building or service. COMMERCIAL COUNT The numeral indicates the number of actual commercial drops at this location. " " = Optional user defined attribute 7. MAKE READY OR POLE LINE PREPARATION MAKE READY Arrangement of existing equipment on the pole must be altered for cable systems installation. " " = Optional user defined attribute In this section, poles are shown as joint use because this occurs most frequently. 5

8. AMPLIFIERS SINGLE OUTPUT AMPLIFIER Input Output MULTIPLE OUTPUT AMPLIFIER Dot shows high output leg, if unbalanced. Input Output LINE EXTENDER Input Output " " = Optional user defined attribute or graphics Examples shown are for guidance (not standard). 9. SPLITTING DEVICES 2-WAY SPLITTER 3-WAY SPLITTER Dot shows high output leg, if unbalanced. DIRECTIONAL COUPLER Model, value designations, or fiber color (optical coupler) are to be shown adjacent or inside symbols. The high loss leg leaves from the angular half of the symbol. Indoor drop splits may have additional user defined symbols. 6

10. POWERING DEVICES AC POWER BLOCK AC POWER INSERTER " " = Optional user defined attributes SB POWER SUPPLY "SB" = Stand By " " = Optional information: voltage, current load, PS name, status monitor. NON-SB POWER SUPPLY "SB" = Stand By " " = Optional information: voltage, current load, PS name, status monitor. CENTRALIZED POWER SUPPLY " " = Optional information: voltage, current load, PS name, status monitor, port numbers. NOTE: Additional graphics such as a circle around the symbol may also be used to designate new/existing locations. 11. LINE DEVICES IN-LINE EQUALIZERS SPLICE " " = Optional user defined attribute or graphics 7

1-OUTPUT DIRECTIONAL TAP 12. SUBSCRIBER TAPS 2-OUTPUT DIRECTIONAL TAP 3-OUTPUT DIRECTIONAL TAP 4-OUTPUT DIRECTIONAL TAP 8-OUTPUT DIRECTIONAL TAP " " = Represents value of tap " " = May be shown inside symbol. Represents value of pad, cable equalizer, addressable or telephony tap, or fiber color (optical tap) Indoor taps may have additional user defined symbols. 13. LINE TERMINATORS RF TERMINATOR (4-output tap shown for example only) SELF-TERMINATING TAP Applies to lowest value tap within any family group. (4-output tap shown for example only) Self-terminating tap may be shown without symbol. 8

14. SIGNAL PROCESSING LOCATIONS HEADEND Location where the highest level of signal processing takes place. PRIMARY HUB In multi-level networks, a signal processing location connected between the headend and secondary hubs or nodes. SECONDARY HUB In multi-level networks, a signal processing location connected between the primary hub and the node. " " = Optional user defined attributes TYPICAL CABLE SYMBOLOGY 1.000 INCH (25.4MM) 0.875 INCH (22.2MM) 15. COAXIAL CABLES 0.750 INCH (19.1MM) 0.625 INCH (15.9MM) 0.500 INCH (12.7MM) 0.412 INCH (10.5MM) OPTIONAL CABLE SYMBOLOGY For specialty cables and cables listed in ANSI/SCTE 15, 2001 (Examples) 0.750 INCH P3 0.540 INCH QR 750P3 540QR 9

16. OPTICAL DEVICES OPTICAL AMPLIFIER "" = Indicates the gain (db) DEMULTIPLEXER "" = Indicates number of outputs "" = Optional user defined attributes MULTIPLEXER "" = Indicates number of inputs "" = Optional user defined attributes BI-DIRECTIONAL MUX/DEMUX "" = Indicates number of outputs "" = Optional user defined attributes OPTICAL TRANSMITTER " " = Input RF level " " = Output optical power Forward Only Forward / Reverse OPTICAL NODE " " = Input optical power " " = Output RF level Forward Only Forward / Reverse FIBER NODE " " = Input optical power " " = Output optical power Forward / Reverse (multiple RF output examples showing various label choices) 1 2 A B 1 2 3 4 C D 3 4 10

17. OPTICAL SPLICE SYMBOLS 2-WAY SPLICE 3-WAY SPLICE 4-WAY SPLICE >4-WAY SPLICE MID-ENTRY SPLICE / RING CUT 18. MISCELLANEOUS OPTICAL SYMBOLS OPTICAL FIBER CABLE " " = Indicates the fiber count " " = Denotes user defined attributes OPTICAL STORAGE LOOP "" = Denotes user defined attributes Uni-Directional Bi-Directional CONNECTOR " " = Connector type SPLITTER "" = Percent or db loss Symbol shown with optional outputs to be added as necessary FIBER SHEATH TRANSITION (Aerial to/from UG) " " = Indicates footage stamp number Symbol--> FIBER FOOTAGE/SEQUENTIAL MARKER " " = Indicates footage stamp number Symbol--> 11

19. DATA BLOCKS SUGGESTED STYLES (scale to fit maps) Information normally appearing includes: - Amplifier Number - Power Supply Number and Power Feed - AC Voltage - Amplifier Cascade - Amplifier Output at Design Frequency - Amplifier Input at Low Forward Channel - Forward Equalizer - Forward Pad - Reverse Output Level - Reverse Input Level - Reverse Equalizer - Reverse Pad - Amplifier Part Number - Footage to Previous Amplifier - Passings Served by Active The size, shape, and rotation of the identification box is at the discretion of the designer. 20. END OF LINE BLOCKS SUGGESTED STYLES (scale to fit maps) Information normally appearing includes: - High Digital Signal - High Analog Signal - Low Analog Signal - AC Voltage The size, shape, and rotation of the identification box is at the discretion of the designer. 12

21. WIRELESS DEVICES OMNI-DIRECTIONAL WIRELESS HUB ((( ))) ))) DIRECTIONAL WIRELESS HUB OMNI-DIRECTIONAL CUSTOMER PREMISES EQUIPMENT (CPE) DIRECTIONAL CUSTOMER PREMISES EQUIPMENT (CPE) ((( ))) ))) ) = Range < 150m (~500ft.) (e.g. WiFi hotspot) )) = Range between 150m and 3km inclusive (~500ft. and ~2mi.) (e.g. wireless plant extension) ))) = Range > 3km (~2mi.) (e.g. long-range microwave) = Over-the-air frequency (e.g. 5.8GHz) = Optional user defined attributes (e.g. polarization; modulation type) 13

14