PIPE AND EQUIPMENT INSULATION SOLUTIONS

Similar documents
EcoTouch Insulation with PureFiber Technology

Fiberglas, Exterior Wall Thermal Insulation

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

B. Types of mechanical insulation specified in this section include the following:

SECTION FIBERGLASS INSULATION

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

SUMMARY Heating REFERENCES 1.2. Thermal Insulation

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

ROCK WOOL Preformed Pipe Section

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MECHANICAL INSULATION

COMMERCIAL BUILDING APPLICATIONS

SECTION HVAC INSULATION

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

NEW NEW. Pipe Products Catalogue. ProRox NEW NEW. Pipe Insulation for High Temperature Industrial Applications PRODUCT NAMES

2.1 DEFINITION OF INSULATION GENERIC TYPES AND FORMS OF INSULATION PROPERTIES OF INSULATION MAJOR INSULATION MATERIALS 4

Peel & Seal Self-Stick Roofing Solutions

CHAPTER 7: Building Systems ROOFING SYSTEMS

CommercialComplete Wall System NFPA 285 Tested Wall Assemblies

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Marine & Offshore Insulation. - products and constructions November 2009

SECTION HVAC AND PLUMBING INSULATION

Guide Specification SECTION HVAC INSULATION PART 1 - GENERAL 1.1 SUMMARY

Bafl-Sorb Sound Absorbing Ceiling Baffles

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Tremco Fire Protection Systems Group Technical Bulletin

Pipe and Equipment Insulations. Micro-Lok HP. High Performance Fiber Glass Pipe Insulation

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

ProRox Slabs (formerly known as RW slabs)

Removable Insulation Blankets from A to Z

SEAMS SEAMING USING SEAM TAPE

Housing Fact Sheets. Insulation Check-Up

Product Guide Specification

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

3 Single-Coated Foam Tapes

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

4 Installation Requirements

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

GreenGuard Housewrap Installation Guide

Gridstone Gypsum Ceiling Panels

CONDENSATION IN REFRIDGERATED BUILDINGS

Underwriters Laboratories Testing Information

TABLE OF CONTENT

Woodcrest. Shingles. Woodcrest Autumn Maple

FOAMULAR XPS Roof Insulation FOR COMMERCIAL BUILDINGS

MECHANICAL INSULATION BEST PRACTICES GUIDE TABLE OF CONTENTS

STENCA PIPE. High quality pipe insulation.

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

GENERAL RUBBER LINING PRINCIPLES

Controlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY

Please read the entire document before purchasing and installing any of these products

ROOFS, SNOW AND ICE DAMS

FLEX-WRAP Foam Pipe Wrap

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

THE IC Y N E N E AD V A N T A G E

Roof Systems Overview

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

GigaCrete Specification PlasterMax

Fire Barrier Duct Wrap 15A

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Marine Exhaust Insulation

Mastics, Coatings, Adhesives & Sealants

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

Composite Panel Firewall Systems

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

Product Information Sheet

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

HVAC Solutions. For heating and air conditioning applications

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

GUIDELINE SPECIFICATIONS

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Mechanical insulation to increase building efficiency. Saving money, energy and the planet.

Mold Preventing I nterior System

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Roof Insulation Building. Energy. Environment friendly e-library

Asphalt Shingle Application Requirements

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

Transcription:

PIPE AND EQUIPMENT INSULATION SOLUTIONS YOUR TRUSTED PARTNER FOR ALL YOUR PIPE AND EQUIPMENT INSULATION NEEDS

OUR PIPE SOLUTIONS OVERVIEW Backed by 65 years experience, Owens Corning Pipe and Equipment Insulation Products combine productivity and energy-saving performance for commercial and industrial systems. Our products deliver energy saving thermal performance and low thermal conductivity to lower building operating costs while providing precise control of processing temperatures. This helps maintain surface temperatures to promote a safe, comfortable working environment. The information in this brochure will provide an overview of the Owens Corning pipe and equipment insulation family of products that are designed to meet your business needs. For additional information call 1-800-GET-PINK or visit www.owenscorningcommercial.com. EVOLUTION This is an industry first new Pipe Insulation with Evolution Paper-Free ASJ and only Owens Corning has it. FIBERGLAS Pipe Insulation with Evolution Paper-Free ASJ is jacketed with a durable, paper free all-service vapor retarder, molded of heavy density resin bonded inorganic glass fi bers. The one-piece, 36 long, hinged sections are opened, placed over the pipe, closed and secured. The SSL II double adhesive closure system provides positive mechanical and vapor sealing of the longitudinal jacket seam. All Evolution Paper-Free ASJ sizes come with the SSL II closure system. Used for insulation of hot, cold, concealed and exposed piping in commercial buildings, industrial facilities and process or power plants. Evolution can be used in any application where standard ASJ is normally used because it meets all of the specifi cation requirements of standard ASJ. Before Evolution After Evolution Does not support mold growth It is moisture resistant and helps improve indoor air quality and has earned a coveted GREENGUARD Microbial Resistance Listing. It s more than 300% tougher* than standard ASJ It resists job site abuse and maintains a fi nished appearance to reduce callbacks Professional appearance The facing is cleanable and can be painted for color-coding and has an appearance that is compatible with standard ASJ Promotes job site productivity All sizes have the SSL II Positive Closure System, which eliminates the need to staple Meets Model Code Fire Requirements UL Classifi ed for Surface Burning Characteristics. Flame spread rating of 25 or less, and smoke development rating of 50 or less means that it can be granted immediate building code approval for use in air plenums and other critical locations *Based on puncture resistance, burst strength and tensile strength testing.

ASJ FIBERGLAS SSL II is a jacketed, pipe insulation molded of heavy density resin bonded inorganic glass fi bers. The onepiece, 36 (914mm) long, hinged sections are opened, placed over the pipe, closed and secured by the smooth, reinforced, wrinkle resistant, all-service vapor retarder jacket (ASJ). This product uses the SSL II closure system and is available in the most popular pipe sizes. For the larger ASJ sizes, FIBERGLAS Pipe Insulation is furnished with a SSL I single adhesive lap seal. The system includes pressure sensitive butt strip seals that complete the positive closure system. VAPORWICK The heart of the Owens Corning VaporWick Pipe Insulation system is a wick material that transports condensed water to the outside of the system for evaporation to the atmosphere. The wick keeps the fi berglass insulation dry, preventing dripping and allowing the insulation to perform effectively over the life of the project. Owens Corning VaporWick Pipe Insulation is an innovative insulation product designed specifi cally for below-ambient temperature applications in severe hot/humid operating environments. Keeps Insulation Dry A specially designed wicking material absorbs condensed water from the pipe surface and wicks it to the outside, keeping the insulation dry and minimizing loss in insulating capability Dual Temperature Applications Rated for operating temperatures which range from 32ºF to 220ºF, making it ideal for dual temperature installations Used for insulation of hot, cold, concealed and exposed piping in commercial buildings, industrial facilities and process or power plants. SSL II Positive Closure System The Positive closure is fast, neat and there is no need for staples which promotes job site productivity Jacket and Lap Shipped Adhered Short pieces of insulation can be cut without jacket loss and the section will not come apart in handling. There are no dog-ears in or out of the carton. Dust and moisture cannot reach the lap seal. Butt strips come in sealed bags inside the carton so they can stay clean until the moment of use Excellent Thermal Performance FIBERGLAS Pipe Insulation s resistance to heat transfer contributes to lower operating costs of heating and/or cooling equipment Meets Model Code Fire Ratings The fl ame spread rating of 25 or less and smoke developed rating of 50 or less means that FIBERGLAS Pipe Insulation can be granted immediate building code approval Meets Model Code Fire Requirements UL Classifi ed for Surface Burning Characteristics. Flame spread rating of 25 or less, and smoke development rating of 50 or less means that it can be granted immediate building code approval for use in air plenums and other critical locations Excellent Thermal Value Resistance to heat transfer contributes to lower operating costs of heating and/or cooling equipment Self-drying feature allows product to be installed on wet pipes systems do not need to be shut down during installation of the VaporWick System Self-sealing Lap Seal - Positive closure is fast, neat, and foolproof. No need for staples or mastic Meets Requirements for Mold and Fungi Resistance VaporWick Pipe Insulation provides no sustenance for mold to propagate and meets the standard ASTM test for fungi resistance

SOFTR DUCT WRAP FRK SOFTR Duct Wrap FRK is a blanket of glass fi ber insulation factory-laminated to FRK vapor retarder facing. A 2 stapling and taping fl ange is provided on one edge. Used for external insulation of commercial and residential heating, air conditioning and dual temperature ducts operating at temperatures from 40 F to 250 F. When applied in accordance with installation instructions, it will provide the installed R-value as published for the product and printed on the facing, assuring specifi ed in-place thermal performance and condensation control. NO-WRAP FIBERGLAS Pipe Insulation is also available without a jacket. No Wrap pipe insulation is designed for fi eld installation with jacketing appropriate to the vapor control, damage or corrosion resistance requirements of the application. Used for insulation of hot, cold, concealed and exposed piping operating at temperatures to 850 F in commercial buildings, industrial facilities or power plants. Excellent Thermal Performance FIBERGLAS Pipe Insulation s low thermal conductivity contributes to lower operating costs of heating and cooling equipment Meets Model Code Fire Ratings The fl ame spread rating of 25 or less and smoke developed rating of 50 or less means that FIBERGLAS Pipe Insulation can be granted Assured Thermal Performance When installed in accordance with instructions so that compression is controlled, SOFTR Duct Wrap FRK provides specifi ed thermal performance. Operating costs are controlled due to reduction of heat loss through duct walls Condensation Control Helps control moisture condensation on the ductwork as well as on the outer vapor retarder jacket. This helps maintain insulation effi ciency and reduces the likelihood of stained ceilings due to moisture damage Flexible It is easy to install Certifi ed Contains at least 50% recycled content, GREENGUARD Indoor Air Quality Certifi ed and GREENGUARD Children and SchoolsSM Certifi ed

FIBERGLAS FLEX WRAP Fiberglas FlexWrap Pipe and Tank Wrap is a fl exible insulation product made from fi berglass blanket bonded together with a thermosetting resin. The fi bers are oriented to provide good compressive strength while providing fl exibility during installation. FlexWrap Pipe and Tank Wrap is suitable for operating temperatures up to 850 F and is available with either PSK (Poly-Scrim-Kraft) or FRK (Foil-Reinforced Kraft) facings. Used to insulate either hot or cold surfaces of pipes, tanks, storage vessels, ducts and similar round or irregular shaped surfaces. All joints and facing penetrations must be sealed with appropriate pressure sensitive tape or vapor retarder mastic when the application requires a vapor seal. The product is intended for indoor use and should be weather protected for use outdoors. Quick, Easy Installation FlexWrap Pipe and Tank Wrap installs easily. The continuous blanket of material easily wraps tanks, pipes, and irregular shaped objects without the effi ciency losses related to strip delamination of fabricated and segmented wrap Low Thermal Conductivity Compared to segmented products means less thickness is required for equivalent heat fl ow FIBERGLAS PIPE AND TANK INSULATION Fiberglas Pipe and Tank Insulation is made of semi-rigid fi brous glass board material, factory-jacketed with a laminated kraft-aluminum foil ASJ facing. The insulation is adhered with the end grain perpendicular to the jacket. Applied to pipes, tanks and vessels 10 NPS and larger. It can also be used to insulate pipe, fl anges, valves, groups of parallel pipes, and pipes with heat tracing lines. It may be applied over existing insulation to increase thickness and satisfy demands for increased energy conservation in alreadyoperating systems. Flexible It is easily wrapped around pipes, tanks, or vessels, while providing good rigidity and abuse resistance Instant Availability It fi ts all pipes, tanks and vessels 10 NPS and larger Strong High compression strength Professional appearance ASJ vapor retarder jacket matches the jacket of Fiberglas pipe insulation for uniform appearance A cost Effective Substitute of Pre-formed Pipe Insulation FlexWrap Pipe and Tank Wrap is an effective alternative to larger sized, pre-formed pipe insulation. FlexWrap Pipe and Tank Wrap fi ts all pipes and equipment of 10 NPS and larger which reduces inventory requirement caused by multiple diameter requirements

FIBERGLAS TIW TYPES I & II Fiberglas TIW Types I and II Insulations are off-white to light tan, noncombustible wool with resilient, inorganic glass fi bers bonded with a thermosetting resin. TIW Type I Insulation is available in rolls and TIW Type II Insulation comes in batts. FIBERGLAS 700 SERIES These insulations are made of inorganic glass fi bers with a thermosetting resin binder and formed into fl exible, semirigid or rigid rectangular boards of varying densities. They are available in plain and faced form in multiple densities and thicknesses. 701, 711 Lightweight, resilient, fl exible insulation in sheet form, used on vessels with irregular surfaces where an exterior fi nish will be supported mechanically. 703, 704 Semi-rigid boards for use on equipment vessels and air conditioning duct work. 705 A high strength, rigid board for use on hot and cold equipment, heating and air conditioning duct work where high abuse resistance and good appearance are required. Type I Insulation is used in applications up to 1000 F at maximum recommended thickness requiring a light weight insulation such as that used in panel systems, fl exible wrap, industrial ovens, or surfaces having irregularities. Its low compressive strength does not make it suitable for use as a base wool for metal mesh blankets. Type II Insulation may be used in panel systems where more compressive resistance than Type I is needed. It is especially suited for use in metal mesh blankets and for use on boilers, vessels and other equipment operating at temperatures up to 1,000 F at maximum recommended thickness. Excellent Thermal Performance Resistance to heat transfer contributes to overall lower operating costs of high temperature equipment Lightweight Fiberglas TIW Types I and II insulation is easy to handle and install, even when large size panels are used Quick, Easy Installation Large batts or blankets cover areas quickly Non-corroding Fiberglas TIW Types I and II Insulation can be used in direct contact with steel, copper and aluminum without corrosive effects 707 For use in acoustical wall panels and specialized ceiling applications. Professional appearance Provides a neat, fi nished appearance in mechanical applications Thermal effi ciency FIBERGLAS 700 Series insulations reduce heat transfer between the equipment and the environment, lowering operating costs of heating and cooling systems Certifi ed Contains at least 55% recycled content Quiet Excellent acoustical properties Equipment operating temperature up to 450 F The boards come unfaced or with ASJ or FRK facing

FIBERGLAS SCR INSULATION BOARD Fiberglas SCR Insulation Board is a lightweight insulation board composed of resilient, inorganic glass fi bers bonded with a thermosetting resin. SCR Board is designed specifi cally for use on selective catalytic reduction units (SCR) in power plants. Equipment operating temperatures up to 1,000 F at thicknesses up to eight inches FIBERGLAS INSUL-QUICK Fiberglas Insul-Quick Insulation is a lightweight insulation composed of glass fi bers bonded together in a semi-rigid, board-like form with a special high temperature binder. Insul-Quick Insulation is used in applications where an outside facing of metal or metal mesh with a fi nishing cement is required. Lightweight and Low Dust It is easy to handle and install. SCR board is free of shot and lighter than mineral wools Quick, Easy Installation Boards in sizes up to 4 x 8 help reduce the number of joints, speeding installation Excellent Thermal Performance SCR Insulation Board s thermal effi ciency contributes to reduced heat loss Equipment operating temperature up to 850 F. Excellent Thermal Performance Resistance to heat transfer contributes to overall lower operating costs of heating and/or cooling equipment Lightweight It is easy to handle and install even when large size boards are used No crumbling, breaking or slumping It cuts cleanly and resists tearing which contributes to excellent long-term thermal performance Large Size Availability Boards in sizes to 4 x 8 help reduce the number of joints, allowing for quick installation

BALANCING ECONOMIC GROWTH, ENVIRONMENTAL STEWARDSHIP AND SOCIAL PROGRESS Sustainability at Owens Corning is a core business strategy. Our company embraces the defi nition of sustainability as meeting the needs of the present without compromising the future. Our approach to sustainability balances economic growth, environmental stewardship and social progress. We bring our philosophy to life in three ways: Greening our operations reducing the impact our manufacturing operations have on the world Greening of our products addressing the environmental footprint of our products throughout their life cycles Accelerating Energy Effi ciency Improvements in the Built Environment working to increase the penetration of energy effi ciency solutions around the world We believe this strategy energizes our people and creates growth opportunities for our customers. For more about sustainability at Owens Corning, visit http://sustainability.owenscorning.com OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-GET-PINK www.owenscorning.com Pub. No. 10013069. Printed in U.S.A. November. 2010. THE PINK PANTHER & 1964 2010 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2010 Owens Corning. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certifi cation mark used under license through the GREENGUARD Environmental Institute. Scientifi c Certifi cation Systems (SCS) provides independent verifi cation of recycled content in building materials and verifi es recycled content claims made by manufacturers. For more information, visit www.scscertifi ed.com.