FARM STORAGE AND HANDLING OF PETROLEUM PRODUCTS

Similar documents
Civil Engineering Sector Labour-Management Health and Safety Committee

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Environmental Management System Procedures

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O

FUELING AND FUEL STORAGE

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Notes. Material 1. Appropriate Flammable Liquids

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Flammable and Combustible Liquids. Slide 1 (of 23)

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

Farm Fuel Tank Safety Guide

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Flammable Liquids Storage

Spill Control Prevention Plan (SCPP)

Fact sheet 6: for farmers

Safe Operating Procedure

Flammable Liquids Storage

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

Suffolk County Department of Health Services. Division of Environmental Quality

Waste Oil Collection / Storage

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

OREGON FIRE CODE Interpretations and Technical Advisories

ADMINISTRATIVE SERVICES MANUAL

Sample Written Program. For. Flammable Liquids

The following definitions apply with regard to requirements specified in this document:

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

OSHA Office of Training and Education 1

How To Safely Handle A Spill

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

PCB STORAGE. 1) 2-drum unit (4 x 2 x 4 ) 2) 4-drum unit (4 x 4 x 4 ) 3) 8-drum unit (8 x 4 x 4 ) 4) 16-drum unit (8 x 8 x 10 )

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Fact sheet 6: for farmers

Outdoor Liquid Container Storage

UltraTech International, Inc. Canadian Secondary Containment Requirements

Fire & Explosion Risks in Service Stations

UNIVERSITY OF WISCONSIN MADISON

BP WIND ENERGY POLICIES AND PROCEDURES

Outdoor Storage of Raw Materials SC-33

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Pressure Vessels (Air Compressors) and LPG Tanks

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Good Housekeeping Practices for DPW/Fleet Maintenance Facilities

ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Section III Hazardous Materials Management

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

BC Fuel Guidelines. 6 th Edition. February 2014

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders


THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO A bylaw to amend Storm Sewer Bylaw No. 1402, 1986

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

Chemical Storage and Spill Response Guidelines

Presented by: Rich Perry Marsh Risk Consulting

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

Important Ontario Fire Code Information for Building Owners in the City of Windsor

APPENDIX G. Guidance from USEPA Region X For ASPPs from Industrial Users APPENDIX 3. Detailed Information to be Considered in Development of IU ASPPs:

APPENDIX G Materials Storage and Handling Guidelines

Queen's University Environmental Health and Safety

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

Hazardous Waste Accumulation, Storage, & Labeling

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

Spray Booth Guideline

MOTOR FUEL DISPENSING SAFETY

Shop Fabricated Aboveground Tank Construction Standards

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

W250. The Agricultural Producers Comprehensive Guide to Federal Oil Pollution Prevention Regulations

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

Environmental Standard Operating Procedure Originating Office: MCAS Miramar Environmental Management Department

Underground Storage Tanks

Spill Prevention, Control. and. Countermeasures Plan

Summary of Environment and Social Impacts for Activates Associated with Petroleum Refining and the Storage of Petroleum Products

Improper storage of potential pollutants will increase the risk of water pollution that may occur because of spills.

DIRECT TRANSFER COAL FACILITY SPILL RESPONSE PLAN

The following definitions apply with regard to requirements specified in this document:

SPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN PREPARED FOR: ARKANSAS STATE UNIVERSITY JONESBORO, ARKANSAS ORIGINAL DATE OF PLAN: APRIL 2005

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

Managing Floor Drains and Flammable Traps

Spill Prevention, Control & Cleanup SC-11

Storage Tank Systems for Petroleum products and allied petroleum products regulations

Fuel Storage Who to ask: tank farm owners/operators

An inventory of hazardous materials used in your workplace will prove useful.

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

The Fuel Storage Tank Regulations 2009

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

Transcription:

Farm Mechanization Order No. 210.510-1 Revised October 2005 FARM STORAGE AND HANDLING OF PETROLEUM PRODUCTS This factsheet outlines environmental and fire-safe practices for the handling and storage of petroleum products (excluding liquid propane), as well as the handling of used oil, oil filters and containers. Methods are identified to reduce evaporative fuel losses from storage tanks. INTRODUCTION CONCERNS AND LEGISLATION Diesel, gasoline and lubricating and hydraulic oils are used extensively on farms today. Handling and storage presents a financial (increasing cost), environmental (small amounts cause adverse effect) and a fire safety concerns (very flammable) to a farm. On-farm receiving, storage and dispensing sites for petroleum products are potential sources of pollution and are fire safety concerns. For instance, one litre of petroleum can contaminate one million litres of water; a leak of one drop in two minutes is 130 litre a year. The main concerns and legislation are: Siting Concerns. The Canadian Farm Building Code (where proclaimed by local government) requires a 12 m separation from any building and property line (underground tanks 1.5 m separation). Ground Water Concerns. The Health Act requires probable sources of contamination to be 30.5 m from ground water wells. Pollution Concerns. The Environmental Management Act regulates pollution concerns: spills and leaks that impact the environment used oil, oil filter and container disposal is regulated The federal Fisheries Act has a section regarding pollution: section 36(3) prohibits the deposit of deleterious substances into watercourses ( deleterious would include petroleum products) Fire Safety Concerns. The BC Fire Code (Part 4) regulates storage tanks containing flammable or combustible liquids. Note that farms are exempt from Part 4, making the requirements voluntary or Beneficial Management Practices (BMP s). Page 1 of 6

SMALL FUEL LARGE FUEL UNDERGROUND FUEL ABOVEGROUND FUEL Fuel tanks less than 230 litres (50 Imperial gal) must meet transportation regulations, ULC (Underwriters Laboratories of Canada) or CSA (Canadian Standards Association) standards. This size of tank should: be stored at least 3 m from any building or, be stored in a building used exclusively for fuel storage that is at least 3 m from other buildings and, be conspicuously marked with the name of the product contained and the words Flammable Keep Fire and Flame Away Fuel tanks 230-4450 litres (50 1,000 Imperial gal) should be stored outside of buildings, either above or below ground, and should: be constructed in accordance with accepted engineering practices have separate fill and vent openings if elevated, have an adequate support of steel, wood or earth bank be marked with the product name and the words Flammable Keep Fire and Flame Away, plus Keep 12 Metres from Buildings The following should be used on underground fuel storage tanks exceeding 250-litre (55 I.gal) capacity: secondary containment of all tanks and piping (e.g., double wall) corrosion protection of all steel tanks and piping leak detection an overfill protection device for the tank a spill containment device at the fill nozzle These fuel storage tanks must be located: 30.5 m from ground water wells (Health Act) 12 m from any building (where Canadian Farm Building Code is proclaimed by local government) These fuel storage tanks should: be at least 12 m from a property line or public road be at least 12 m (40 ft) from any building (this distance must be available between any vehicle, equipment or container being filled and any building) - buildings refers to any combustible structures, hay stack, etc be at least 15 m (50 ft) from any watercourse be at least 30 m (100 ft) from any source of water used for domestic purposes be located away from other storages containing chemical and fertilizer products to minimize hazards due to fire, mixing, or contamination of substances have clear and easy access to minimize the potential for accidental collisions have protection from unauthorized access by using fences, locked gates, valves, fill and vent caps prevent spilled liquid from entering buildings or waterways by using grading or curbing and drainage (noncombustible sills, curbs, or dikes of sufficient height to contain spills the stored volume plus 10 percent). Note: an alternative is a double-walled tank Double-Walled Fuel Tanks. These fuel storage tanks must be located similar to other above ground tanks. Although more expensive, double wall tanks offer spill containment and reduced fuel loss from evaporation. Photo courtesy of Highland Tank Page 2 of 6

MOBILE FUEL INDOOR FUEL SAFETY RECOMMENDATIONS For jerry cans, drums and truck-box fuel tanks: keep upright and secure during transport avoid dispensing from horizontal drums have secondary containment for truck boxes have a fuel spill clean up kit Fuel tanks used for dispensing fuel located within a building should meet Fire Code requirements (see Fire Code for other details or local Fire Commissioner Office): if vapours are released into the room - have continuous mechanical ventilation of at least 18 m 3 /hr per square metre of room area, but not less than 250 m 3 /hr - have automatic interlocks so activity generating vapours cannot be preformed when the ventilation system is not in operation - have audible alarm upon shutdown of the ventilation system bond and ground tank, piping and discharge equipment Storage Site. In addition to safe siting, leakage protection, etc, ensure the site has: a rust-protected steel tank a hand or electric pump that removes fuel through the top of the tank gravity fed delivery has the most risk of spills, etc a anti-siphon valve between pump and tank to prevent tank from draining if the line is broken a self-closing, automatic shut off, nozzle a No Smoking Ignition Off sign at the site a dry chemical ABC fire extinguisher at the site of at least 20 pounds that is maintained regularly a bonding line to ground the tank and vehicle being filled no storage of combustible items near tanks no long grass, weeds, etc, near the area at the tanks Refueling. Follow these practices when refueling: remain in attendance at the fueling site shut off engines and other ignition sources while refueling shut off or do not use cell phones when refueling (static electricity concern) do not smoke within 7.5 m (25 ft) while refueling Theft. Consider the following to reduce fuel theft: locate at the back of the yard but keep it visible light the area use a locking device on the tank and nozzle if using an electric pump, turn off power to pump Refer to Figure 1, next page, for an example of well-planned farm fuel storage. LEAKS AND SPILLS Consider the following points regarding leaks & spills: monitor tank & surrounding area for leaks weekly keep an ongoing fuel inventory sheet using a fuel meter or by dipping the tank immediately clean up any spills that may occur report spills greater than 100 litres to 1-800-663-3456 (Spill Reporting Reg.) also call local police if the spill is on a highway contain small spills and allow soil microbes to break down the petroleum Page 3 of 6

Figure 1 A Well Planned Farm Fuel Storage Site SYSTEM MAINTENANCE Considering the following maintenance points: install the tank so it is sloped slightly away from the fuel outlet and to a (tamperproof) drain at the rear of the tank for removal of water & sediment flush the tank annually to remove sediment and water (dispose of material in acceptable manner) use a tank fuel filter to prevent tank contamination from entering equipment allow 24 hours after a tank fill up or fuel move to let tank sediment resettle before refueling, and/or install a good quality fuel filter use a fuel meter in combination with a fuel log to establish fuel consumption rates of various tractors and farm operations keep the use of mobile fuel tanks to a minimum CONTINGENCY PLAN Develop a contingency plan (written and readily available at the oil and fuel storage site)that provides a timely and effective response to emergencies involving the release of petroleum products into the environment from: accidental spills, such as when transporting, storing, applying or dispensing release due to building fires or natural events, such as forest fires, floods, or earthquakes, or due to vandalism Page 4 of 6

FUEL STORAGE LOSSES An often overlooked aspect of fuel storage is fuel loss due to evaporation. Fuel evaporation during storage is an environmental concern and a farm financial loss. Losses due to evaporation depend on the: type of fuel type of storage fuel storage temperature duration of storage Evaporation losses, which increase with higher temperatures, are much greater for gasoline than for diesel fuel (gasoline is more volatile). Gasoline evaporation losses are significant even during winter because of the additives in winter fuel. Evaporation from aboveground tanks is due to heating of the tank by the sun which causes the fuel to volatilize and vent to the atmosphere. Underground tanks have low evaporation losses but are generally not used on farms due to the installation costs, especially with the environmental protection required. Double-walled tanks are becoming available that have built-in leakage containment and reduced evaporative losses. Fuels may be stored for up to a year and still be usable. However, such long duration storage is not usually recommended as a reduction in fuel quality can be expected. Also, the chance of fuel contamination from moisture condensing within the tank increases with time. Table 1, below, shows summer evaporation losses reported from a 1200-litre (265 Imperial gal) aboveground gasoline storage tank, as well as losses from underground and doubled-walled tanks for comparison. Four methods to reduce fuel evaporation losses are apparent: Table 1 Tank Conditions EVAPORATION LOSSES FROM 1200 LITRE (265 Imperial gal) ABOVEGROUND GASOLINE STORAGE TANK 1 Evaporation Lost per Summer Month Percent of Full Tank Lost Dark tank in sun 38 Litres 3.2 % White tank in sun 23 Litres 1.9 % Dark tank in sun with pressure vent cap 21 Litres 1.8 % White tank in sun with pressure vent cap 9 Litres 0.8 % Dark tank in shade 9 Litres 0.8 % 2 White tank in shade with pressure vent cap 5 Litres 0.4 % for comparison purposes: underground tank less than 4 Litres 0.3 % 3 double-walled aboveground tank losses similar to underground tank 1 reported from University of Nebraska, 1981 2 economical and environmental choice 3 double-walled tanks also have built-in spill containment Page 5 of 6

Step 1. Paint the Tank. The use of reflective paint (silver or white) will reduce losses by up to 40 percent over a dark tank. A good coat of paint will also reduce rusting of the tank Step 2. Use a Pressure Vent Cap. Direct venting of the tank fumes are restricted until a slight pressure has built up in the tank, reduces losses a further 50 %. A painted and pressure-vented tank has 75 % less evaporation losses than a dark tank. These two improvements should be considered standard for all farm fuel tanks, especially gasoline storage tanks. Step 3. Shade the Tank. A painted and pressure-vented tank in the shade further reduces losses by over 40 %. A simple roof over the tank will provide complete shading, as well as reduce weathering of hoses and valves, provide storage for lubricants and solvents and provide cover from the weather while refueling. Or,.Use a Double-walled Tank. While more expensive than other tanks, when replacing a tank, consider a double-walled tank for spill containment and reduced evaporation losses. USED OIL, FILTERS, AND CONTAINERS Used oil, oil filter and container disposal is an environmental concern regulated by regulations under the Environmental Management Act. These items are considered special wastes under the Hazardous Waste Regulation. This regulation prohibits the disposal of special wastes into landfills or municipal sewers. Spreading used oil onto land as dust control is not an appropriate disposal method. Recycling is the preferred option for both used oil and oil filters. The Post-Consumer Residual Stewardship Program Regulation requires sellers of lubricating oil to accept the return of waste lubricating oil at no charge (lubricating oils include typical farm oils). The used oils must be kept free of water and solvents and should be put into clean containers. A simple way to ensure this is to return the used oils in the plastic pails they were received in, also ensuring that the pails are recycled. Recycling is available for waste oil, oil filters and containers by phoning BC Used Oil Recycling Line (1-866-322-8662), or go to their web site to locate the closest facilities: www.usedoilrecycling.com FOR FURTHER INFORMATION CONTACT RESOURCE MANAGEMENT BRANCH Lance Brown, Engineering Technologist, Kamloops Ministry of Agriculture and Lands Phone: (250) 371-6064 1767 Angus Campbell Road Email: Lance.Brown@gov.bc.ca Abbotsford, BC CANADA V3G 2M3 Page 6 of 6