HIS Excellency the Governor, with the advice of the Executive Council,

Similar documents
Code of Practice Electricity transmission and distribution asset management. February 2009

The Electrical Safety Regulation (pre and post 1 January 2014)

2002 No ELECTRICITY. The Electricity Safety, Quality and Continuity Regulations 2002

11. Assessment of service 12. S-phase supply 13. Water heaters NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS

NEW ZEALAND ELECTRICAL CODE OF PRACTICE. for ELECTRICAL SAFE DISTANCES

Hyperlinks are Inactive

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

TORONTO MUNICIPAL CODE CHAPTER 880, FIRE ROUTES. Chapter 880 FIRE ROUTES

Electrical safety rules

1995 No. 425 WATER BOARD (CORPORATISATION) ACT 1994 REGULATION

Please check with your local inspection authority for any additional requirements before installation.

Electrical Safety Tips. Help us keep you safe

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

NZECP 14: 1995 ISSN COVER PAGE

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

environment briefing02

Trees and powerlines. Office of the Technical Regulator. sa.gov.au/energysafe

Electrical Practices for Construction Work

This document must be read in conjunction with the Permit to Work and Service Interruption Notice policy.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

BUSINESS POLICY ELECTRIC SERVICE PRACTICES SP 1.1 INTRODUCTION

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

Treasure Valley Electric Plan - Community Advisory Committee

IRRIGATION PUMPING Table of Contents - Section 900

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

GroundRod AC Substation Earthing Tutorial

Wellesley Municipal Light Plant. Standard Requirements for Electric Service

Trees and powerlines. Office of the Technical Regulator. Web: sa.gov.au/energysafe Phone:

Fence By-law. PS-6 Consolidated May 14, This by-law is printed under and by authority of the Council of the City of London, Ontario, Canada

Questions and Answers for Heating and A/C Contractors

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Work in Substations - General

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

WA Electrical Requirements

Unified requirements for systems with voltages above 1 kv up to 15 kv

FIREFIGHTER SAFETY. Stay safe during substation fires

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

Service & Installation Rules 2014

GENERAL RULES AND REGULATIONS FOR ELECTRIC SERVICE CUSTOMER'S UTILIZATION OF ELECTRIC SERVICE

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

PERMITS REQUIRED & PERMIT EXEMPTIONS

Occupational Health and Safety Amendment (Long Distance Truck Driver Fatigue) Regulation 2005

REVIEW OF ELECTRICITY (CONSUMER SAFETY) ACT 2004 ISSUES PAPER

Electricity Supply (General) Amendment (Renewable Energy Sources) Regulation 2006

Electrical Grounding. Appendix C

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Underground Commercial Electric Service

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR OVERHEAD ELECTRIC LINES

ACCREDITATION OF PROVIDERS LEVEL 1 CLASS: OF CONTESTABLE SERVICES. Clause 26 Electricity Supply (Safety and Network Management) Regulation 2014

Earthing Guidance Notes

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

June July 18, of 7

DALLAS COUNTY, IOWA CHAPTER 48 SMALL WIND ENERGY CONVERSION SYSTEMS ORDINANCE FOR THE UNINCOPORATED AREA OF DALLAS COUNTY, IOWA

Asbestos Removal and Assessor Licensing Information

Contractor Connect Scheme Electrical Contractor and Worker Handbook

Chapter 1: PREFACE. In case of conflict between any provision of any rate schedule and these rules and regulations, the rate schedule shall apply.

THE CORPORATION OF THE TOWNSHIP OF SEVERN BY-LAW NO

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Occupational Health and Safety Amendment (Residual Current Devices) Regulation 2011

ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering

WA Electrical Requirements

Customer Installation Safety Plan. March 2015

Private Parking Areas Act 1986

Electrical safety code of practice Managing electrical risks in the workplace

Community Housing Providers (Adoption of National Law) Bill 2012

`Fall Protection Guidelines in Construction

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

LAND USE CODE CHAPTER GENERAL REGULATIONS

Electrical safety and you

Distribution Substation Manual (DSM) Section I - Introduction

Workers Compensation Amendment (Advertising) Regulation 2005

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations

800 Communications Circuits

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Insurance Premiums Order

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

The Passenger and Freight Elevator Act

Electric Service Manual

ARTICLE IV. DRIVEWAYS

Circuit Electrical Testing

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Handbook 16. Handbook 16. AC electrified lines. GE/RT8000/HB16 Rule Book

AN ORDINANCE AMENDING CITY CODE CHAPTER 15-7 REGARDING ACCESS TO UTILITY INFRASTRUCTURE BY COMMUNICATIONS PROVIDERS AND MANAGEMENT OF RIGHT-OF-WAY

Motor Accidents Compensation Amendment Act 2006 No 17

METERING CODE. Energy Market Authority of Singapore

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

THE REGIONAL MUNICIPALITY OF NIAGARA BY-LAW NO SIGN BY-LAW

Call the Experts at REA Energy Services for all of Your Electrical and HVAC Needs.

Pre-Apprenticeship Training Apprentice Training Post-Trade Training Short Refresher Courses

Transport (Vehicular Traffic Road Closure) Regulations 1965

Heavy Loads on Roads By-law

FIXED CHARGE: This is a cost that goes towards making the service available, including

Transcription:

ELECTRICITY ACT 1945 REGULATION (Electricity (Overhead Line Safety) Regulation 1991) NEW SOUTH WALES [Published in Gazette No. 114 of 9 August 1991] HIS Excellency the Governor, with the advice of the Executive Council, and in pursuance of the Electricity Act 1945, has been pleased to make the Regulation set forth hereunder. ROBERT WEBSTER Minister for Energy. Citation 1. This Regulation may be cited as the Electricity (Overhead Line Safety) Regulation 1991. Commencement 2. This Regulation commences on 1st September, 1991. Repeal 3. The Overhead Line Construction and Maintenance Regulations 1962 are repealed. Definitions PART 1 PRELIMINARY 4. In this Regulation: active conductor means any one of those conductors of an electricity supply system which is maintained at a difference of potential from the neutral or earthed conductor and, in relation to a system which does not contain a neutral or earthed conductor, includes all conductors of the system;

2 aerial conductor means any conductor which is placed above the ground, in the open air, and is suspended between 2 or more supports; bare, in relation to a conductor, means not insulated; carriageway means: (a) that portion of a public road which is improved or designed for use by, or used by, vehicular traffic, including any road shoulder and breakdown lane but not including any footpath or other lateral part of the road not so improved, designed or used; or (b) that portion of a defined vehicular track (whether formed or unformed) which is ordinarily used by the public and which is located on a road reserve or on land under the control of the Western Lands Commissioner or in a national park, State forest or other Crown land, and includes the entire width of the defined vehicular track plus 2.5 metres on each side of the track; conductor means any wire or cable used or placed in position for the conveyance of electricity; consumer s aerial line means an overhead line operating at a voltage lower than 650 volts and being part of a consumer s installation; consumer s installation means all the electric wires, cables, appliances, fittings, insulators and apparatus installed in, on, under or over any premises and used for, or for purposes incidental to, the conveyance, measurement, control or use of electricity supplied or intended to be supplied by an electricity supply authority, but does not include: (a) any electricity supply main or service line, meter or apparatus the property of an electricity supply authority and used solely for the conveyance, measurement or control of electricity supplied to any premises; and (b) any movable electrical equipment; Corporation means the Energy Corporation of New South Wales constituted under the Energy Administration Act 1987; earthed means electrically connected to the general mass of earth; insulated, in relation to an overhead line, means provided with insulation material of the appropriate grade for the voltage at which the overhead line is or is to be operated;

3 overhead line means any aerial conductor or conductors with associated supports, insulators and other apparatus erected for the purpose of the transmission, distribution or conveyance of electricity; overhead service line means an overhead line operating at a voltage lower than 650 volts located between an electricity supply authority s mains and the point of attachment to a consumer s ins tallation; point of attachment means the point at which aerial conductors of an overhead service line or consumer s aerial line are terminated on a consumer s building, pole or structure; point of entry means the point at which the consumer s mains enter a building or appurtenance of a building; road means a public thoroughfare ordinarily used by motor vehicles or, in the case of land under the control of the Western Lands Commissioner, or in a national park, State forest or other Crown land, means a defined vehicular track, whether formed or uniformed, ordinarily used by the public; support means the total structural system used to support an overhead line at a particular location and includes elements such as foundations, poles, steelwork, stays, struts, crossarms and fittings; voltage means the nominal difference of potential between active conductors, or the nominal difference of potential between an active conductor and ground multiplied by the square root of 3, whichever is the greater. Scope and application 5. (1) This Regulation, except where otherwise expressly provided, applies to all overhead lines other than the following: (a) overhead lines forming part of an overhead traction contact system or associated feeder when carried on the contact system supports; (b) an overhead line operating at a voltage not exceeding 32 volts alternating current or 115 volts direct current; (c) an overhead line to which the Coal Mines Regulation Act 1982, or any rules or regulations made under that Act, apply or to which the Mines Inspection Act 1901, or any rules made under that Act, apply; (d) any pat of an overhead line which is within the boundaries of a fence of enclosure preventing ready access by unauthorised persons and which is used for the purpose of connection to a ground-type substation, regulating station or the like;

4 (e) an overhead line.operating at a voltage lower than 650 volts, constructed in accordance with the relevant S.A.A. Wiring Rules (within the meaning of the Consumers Electrical Installations (Safety) Regulations 1961), which forms part of a consumer s installation and has been installed in accordance with those Regulations; (f) an overhead line or any section of an overhead line which is out of service for maintenance or upgrading; (g) an overhead line or any section of an overhead line which is under construction and not yet placed into service. (2) Despite subclause (1) (d), the requirements of clause 22 (3) apply to protective devices associated with an overhead line even if the devices are located within a ground-type substation, regulating station or the like. Crown bound 6. This Regulation binds the Crown. Special exemptions 7. The Corporation may by instrument in writing exempt the owner of an overhead line from complying with any provision of this Regulation and may impose conditions on the exemption. Unsafe of hazardous work 8. (1) Despite any other provision of this Regulation, the Corporation may direct that an overhead line, or part of an overhead line, to which this Regulation applies that it thinks is unsafe or hazardous be disconnected, removed, repaired or made safe to the satisfaction of and in the manner and within the time specified by the Corporation. (2) Such a direction is to be given in writing to the owner of the overhead line concerned. PART 2 SAFETY REQUIREMENTS FOR THE DESIGN AND CONSTRUCTION OF NEW OVERHEAD LINES Application 9. Except as provided by clauses 5 and 7, this Part applies: (a) to all overhead lines placed into service on or after the commencement of this Regulation (other than overhead lines to which Part 3 applies); and

5 (b) to any part of an overhead line which is upgraded, renewed or replaced after that commencement. Insulated conductors 10. (1) The maximum temperature at which any insulated aerial conductor is designed to operate, having regard to its required current loading (excluding fault currents) and to the climatic conditions likely to be experienced, must not be such as to cause damage to any insulation sufficient to cause injury from electric shock to any person or damage to property. (2) Every aerial active conductor of an overhead service line or consumer s aerial line, if terminating on a building or appurtenance to a building, must be insulated between the last pole and the point of attachment on the building or appurtenance, including the connection to the consumer s installation. Loading conditions 11. (1) Calculation of the stresses to which supports, insulators and conductors may be subjected must take into account the conditions likely to be experienced in service so as to prevent failure, as far as is reasonably practicable, of those components. (2) An insulated overhead service line or consumer s aerial line is not to be attached to a building or appurtenance to a building unless a point of attachment capable of withstanding, without damage, any loads to which it may be subjected under design conditions has been provided. Earthing of supports 12. (1) All portions of supports or attachments to supports which form part of an overhead line and are capable of being touched by a person without the use of a ladder or other device to assist access, and which might reasonably be expected to become energised from the electricity supply system in the event of failure of insulation or contact with a conductor, must be earthed, insulated or enclosed in such a manner as to prevent, so far as is reasonably practicable, any injury arising from the presence of a voltage gradient between earth and the support or attachment. (2) All earthing conductors which connect any part of an overhead line to the earth must be protected from mechanical damage from ground level to a height not less than 1.8 metres above ground level.

Location of point of attachment 6 13. The position of the point of attachment must not be normally accessible to any person without the use of a ladder or other device to assist climbing. Prevention of unauthorised access 14. The owner of an overhead line, where the circumstances reasonably require, must fit suitable devices or undertake effective measures to prevent, so far as is reasonably practicable, access (other than access obtained by the use of a ladder or other device) by any member of the public to a position near any live aerial conductor or apparatus, where injury from electric shock may be possible. Clearances of conductors from ground 15. (1) The aerial conductors of an overhead line (other than insulated aerial conductors of an overhead service line) must be so located that, when operating at the voltage specified in Column 1 of Table A, the distances to ground in any direction, from any position to which any part of such conductors may sag under operational conditions (excluding fault currents or emergency load currents), are not less than the distances specified in Columns 2, 3 and 4 of Table A in relation to that voltage. Column 1 Column 2 Column 3 Column 4 Distances to ground in any direction Voltage Over a carriageway Over land other than a carriageway or land described in Column 4 Over land which due to its steepness or swampiness of terrain cannot be traversed by traffic or mobile machinery Bare or insulated conductor not exceeding 650 volts or any insulated and earthed screened conductor exceeding 650 volts 5.5 metres 5.5 metres 4.5 metres

7 TABLE A CLEARANCES OF CONDUCTORS FROM GROUND continued Column 1 Column 2 Column 3 Column 4 Voltage Bare conductor exceeding 650 volts but not exceeding 33,000 volts or insulated conductor exceeding 650 volts Distances to ground in any direction Over a carriageway 6.7 metres Bare conductor exceeding 33,000 volts 6.7 metres but not exceeding 132,000 volts Bare conductor exceeding 132,000 volts but not exceeding 220,000 volts Bare conductor exceeding 220,000 volts but not exceeding 330,000 volts Bare conductor exceeding 330,000 volts but not exceeding 500,000 volts Over land other than a carriageway or land described in Column 4 Over land which due to its steepness or swampiness of terrain cannot be traversed by traffic or mobile machinery 5.5 metres 4.5 metres 6.7 metres 5.5 metres 7.5 metres 7.5 metres 6.0 metres 8.0 metres 8.0 metres 6.7 metres 9.0 metres 9.0 metres 7.5 metres (2) The insulated aerial conductors of an overhead service line must be so located that the distances to ground in any direction from any position to which any part of such conductors may sag under operational conditions (excluding fault currents or emergency load currents) are not less than the distances specified. in Table B. TABLE B CLEARANCES OF INSULATED OVERHEAD SERVICE LINES FROM GROUND Location Over the centre of a carriageway Over any part of a carriageway (other than the centre) Distances to ground in any direction 5.5 metres 4.9 metres

8 TABLE B CLEARANCES OF INSULATED OVERHEAD SERVICE LINES FROM GROUND continued Location Over a vehicular crossing of a footway (other than a residential driveway) Over land (other than land associated with a dwelling which is, or is likely to be, used by vehicles) Over a vehicular crossing of a footway associated with a residential driveway and over any portion of a footway Over land which is, or is likely to be, used by vehicles and is associated with a dwelling Elsewhere Distances to ground in any direction 4.5 metres 4.5 metres 3.0 metres 3.0 metres 2.7 metres (3) Overhead lines erected above land which has undergone a change of use which v varies the application of subclause (1) or (2) must be reconstructed in accordance with the requirements of those subclauses. Clearances of conductors from structures 16. The aerial conductors of an overhead line must be so located away from structures or parts of structures that the swing or sag of the conductors under operational conditions (excluding fault currents or emergency load currents) is not such as to cause injury from electric shock to any person or damage to property. Arrangement and separation of aerial conductors 17. (1) Where aerial conductors, the voltage of which does not exceed 650 volts, are carried on the same pole or support as those of a higher voltage, the lower voltage conductors must be placed below the higher voltage conductors. (2) Subclause (1) does not apply to: (a) insulated pilot cables erected for the purpose of protection or telecommunication; or (b) insulated cables for auxiliary power supplies; or (c) overhead earth wires; or (d) insulated and earthed screened conductors.

9 (3) Any 2 bare aerial conductors carried on the same poles or supports or on separate poles or supports and having a difference in voltage with respect to each other, must have adequate, as far as is reasonably practicable, vertical, horizontal or angular separation from each other to prevent the conductors coming into contact with or within arcing distance of each other. Automatic de-energisation of conductors under fault conditions 18. Aerial conductors of an overhead line must, where reasonably practicable, be automatically de-energised under permanent fault conditions. PART 3 SAFETY REQUIREMENTS FOR EXISTING OVERHEAD LINES Application 19. Except as provided by clauses 5 and 7, this Part applies to all existing overhead lines, being: (a) overhead lines placed into service before the date of commencement of this Regulation; or (b) overhead lines, designed and constructed in accordance with the Overhead Line Construction and Maintenance Regulations 1962, as in force immediately before the commencement of this Regulation, and placed into service within 6 months after the commencement of this Regulation. Compliance with regulations 20. (1) All existing overhead lines must comply with: (a) Part 2; or (b) the law relating to their construction that was in force at the time of the erection of such lines or placing of such lines into service, and with subclauses (2) (4). (2) Where any land above which overhead lines have been erected undergoes a change of use that varies the application of ground clearances specified by the law relating to their construction, the portions of those overhead lines which are situated over the land must be reconstructed in accordance with the requirements of clause 15 (1) and (2).

10 (3) Every bare aerial active conductor of an overhead service line or consumer s aerial line terminating on a building or appurtenance to a building must be insulated between the last pole and the point of attachment on the building or appurtenance, including the connection to the consumer s installation. (4) The owner of an overhead line, where the circumstances reasonably require, must fit suitable devices or undertake effective measures to prevent, as far as is practicable, access (other than access obtained by the use of a ladder or other device) by any member of the public to a position near any live aerial conductor or apparatus, where injury from electric shock may be possible. (5) For the purposes of subclause (3), covered conductors complying with A.S. No. C.306-1958 (Australian Standards Code specification for bare and covered hard-drawn copper conductors (for overhead lines)) or BS 6485:1971 (British Standards specification for PVC-covered conductors for overhead power lines) and erected before 8 July 1987 are to be regarded as insulated. Application PART 4 MAINTENANCE REQUIREMENTS FOR ALL OVERHEAD LINES 21. Except as provided by clauses 5 and 7, this Part applies to all overhead lines, whether placed in service before, on or after the commencement of this Regulation. Maintenance of lines and fittings 22. (1) A11 overhead lines, including earthing conductors, electrodes and clamps associated with an overhead line, must be periodically inspected and, if considered necessary, tested and must be maintained in proper working order. (2) The integrity of insulation of overhead service lines and consumers aerial lines must be maintained in the vicinity of the point of entry or adjacent to roofs or structures, which, while not normally accessible to persons, may become accessible under certain circumstances and result in contact by persons with the insulated service wires, service loops or connectors.

11 (3) All protective devices, including fuses, automatic reclosing circuit breakers, protection relays or the like, provided to operate in conjunction with the requirements of clause 12 (1) or 18, must be periodically inspected and, if considered necessary, tested and must be maintained in proper working order. Avoidance of contact between trees and aerial conductors 23. (1) Where contact between any aerial conductor of an overhead line and any tree or flora might reasonably be expected to result in consequential injury from electric shock to any person or damage to property, the owner of the line must ensure that the tree or flora is trimmed or other measures are taken to prevent contact with the aerial conductor. (2) If tree trimming is undertaken, provision must be made for the expected regrowth of trees or flora prior to the next planned inspection. Clearance to ground and structures 24. All overhead lines must be periodically inspected and must be maintained to ensure that the clearances to ground and structures are not less than those prescribed by Part 2 and Part 3. Disused lines 25. If an overhead line has ceased to be used for the conveyance of electricity, the owner of the line must dismantle it as soon as is reasonably practicable or continue to maintain it in accordance with this Regulation. Penalties PART 5 OFFENCES 26. Any person who: (a) being the owner of an overhead line, places into service a new, upgraded, renewed or replaced section or part of an overhead line to which Part 2 applies which does not comply with the requirements of that Part; or (b) being the owner of an overhead line to which Part 3 applies, fails to comply with the requirements of that Part; or (c) being the owner of an overhead line to which Part 4 applies, fails to maintain the overhead line in accordance with that Part; or

12 (d) being the owner of an overhead line, fails to comply with any condition of an exemption relating to the overhead line under clause 7; or (e) being the owner of an overhead line, fails to carry out a direction of the Corporation under clause 8 to the satisfaction of and in the manner and within the time specified by the Corporation; or (f) not being the owner of an overhead line, seeks to gain access by the use of a ladder or other device, without the authority of the owner, to any position near any live aerial conductor or apparatus, where injury from electric shock may be possible, is guilty of an offence and liable to a penalty not exceeding $2,000 and also a daily penalty not exceeding $200 for any continuing offence. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. NOTES TABLE OF PROVISIONS PART 1 PRELIMINARY Citation Commencement Repeal Definitions Scope and application Crown bound Special exemptions Unsafe or hazardous work PART 2 SAFETY REQUIRMENTS FOR THE DESIGN AND CONSTRUCTION OF NEW OVERHEAD LINES Application Insulated conductors Loading conditions Earthing of supports Location of point of attachment Prevention of unauthorised access Clearances of conductors from ground Clearances of conductors from structures Arrangement and separation of aerial conductors Automatic de-energisation of conductors under fault conditions PART 3 SAFETY REQUIREMENTS FOR EXISTING OVERHEAD LINES Application Compliance with regulations

13 21. 22. 23. 24. 25. PART 4 MAINTENANCE REQUIREMENTS FOR ALL OVERHEAD LINES Application Maintenance of lines and fittings Avoidance of contact between trees and aerial conductors Clearance to ground and structures Disused lines PART 5 OFFENCES 26. Penalties EXPLANATORY NOTE The object of this Regulation is to repeal the Overhead Line Construction and Maintenance Regulations 1962 and to replace those Regulations with a new Regulation which deals with the same subject-matter, namely, the safety requirements relating to the erection and maintenance of certain overhead lines. The Regulation is divided as follows: Part 1 Preliminary contains definitions, specifies the overhead lines to which the Regulation applies, enables the Energy Corporation to grant exemptions and give directions and states that the Regulation binds the Crown. Part 2 Safety Requirements for the Design and Construction of New Overhead Lines places obligations on the owners of such lines to comply with specified safety requirements. Part 3 Safety Requirements for Existing Overhead Lines places obligations on the owners of such lines to comply with specified safety requirements. Part 4 Maintenance Requirements for All Overhead Lines places obligations on the owners of such lines to ensue that the lines are maintained in accordance with specified safety requirements. Part 5 Offences makes it an offence for the owner of an overhead line not to comply with the Regulation or the term of an exemption or direction given under the Regulation or for the person to gain unauthorised access to certain parts of overhead lines and specifies a maximum penalty for the offence of $2,000 and $200 for each day such an offence continues.