EX-TECH SIGNALLING SAS CP/PB-125 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BUTTON TECHNICAL MANUAL

Similar documents
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Instructions for Safe Use

Operating Instructions

Explosion proof enclosures

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Safety instructions VEGADIS DIS81.CEIA/V****

Technical data sheet TDS0070

Terminal Box. Specifications TNCN

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Terminal Boxes Series 8146

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Control and Distribution Boxes made of Stainless Steel Series 8150

Operating Instructions

Flameproof Audible Signal 115 db (A) Series YA90

Compact pressure switch Flameproof enclosure Ex d Model PCA

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Linear Luminaire with LED Series EXLUX 6402/2

Floodlight Range Installation Guide

Plug and Socket Devices SolConeX 16 A Series 8570

Wolflite Safety Handlamp H-251E

Technical Data. Dimensions

Design of intrinsically safe systems

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Plug and Socket Devices CES 63 A Series 8579

Worcester DS/DM Series UltraSwitch Switch box

SEISMIC VELOCITY TRANSDUCER T1-40

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Series 8146/5-V37 and Series 8150/5-V37

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Acclaim III Recessed Fluorescent Luminaires ATEX

Operating Instructions

Technical Data. Dimensions

Modular I/O System Analog and Digital Interface Modules

Charge Regulator SCR 12 Marine

conventional system operation

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Plastic tube flowmeters Series PT/PS

2.12. page Products for Explosion hazardous Environment

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

MIC-WKT and MIC-WKT-IR

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

8146/5 Series Breaker Panelboards

Flow switches Series AD/VH

DLP-PU/E Instruction Manual

Manual for Fire Suppression & Methane Detection System

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

TIG INVERTER INSTRUCTION MANUAL

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Inductive sensor NI10-M18-Y1X-H1141

Cable Plug acc. to DIN EN , Form A

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

HYDRAULIC LIFT TABLE CART 2200-LB.

Combi B Alarm box. Mounting instructions

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Oil and Coolant Circulating Heating System. Model - OCSM

Mureva Assembly surface mounted wiring devices

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Instruction Manual. ThinkTop Basic Digital VDC PNP/NPN ESE00225EN

Electrical Equipment in Hazardous Areas: Field Inspections

ATL Fuel Level Sender Probes

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Digital Fingerprint safe

! WARNING. Before using product, read and understand instructions.

Global Water Instrumentation, Inc.

Fire Alarm System Accessories

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Single Station Remote Alarm

OPL BASIC. Dosing System for Professional Laundry machines. Contents

HAZARDOUS AREA TECHNICAL GUIDE

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Installation & User Instructions

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SELECTION, APPLICATION AND MAINTENANCE

Triple Waveband Infra-Red Flame Detection

5800 Temperature Sensor Cable Assembly

Advantium 2 Plus Alarm

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Antenna Splitter ASA 1. Instruction manual

Transcription:

PRODUCT NAME: CP/ PB-125- EXPLOSIONPROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH-SIG-SAS-12-CP-PB125-150-TM-EN-REV03 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BUTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex tb IIIC T85 C EX-TECH SIGNALLING SAS CP/PB-125 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BUTTON TECHNICAL MANUAL Marking details Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make alterations in line with technical advances and industry standards.

1.0 INTRODUCTION CP/PB-125 series Explosion-proof Manual Call Point/ Push button is designed for use in according to Oil & Gas, Offshore Platform, Chemical, Petrochemical, Refinery and Marine Industries etc. Enclosure material is Stainless Steel. The design of two LED indicators (Green and/or Red) is unique. It is compatible with PLC, DCS and ESD system via 4-20 ma output. It is ideal to be used as an explosion-proof Manual Call Point for Fire Alarm System with Addressable Module fixed. There are four different types of manual call point available the one with the red LED, green LED, both red and green LED and none. Insert before the one chosen by customer. With only red LED indicator- During normal operation, the red LED will not be on unless the glass is broken by the operator when the device fault or alarm status arises. With only green LED indicator During normal operation, the green LED will be on unless the glass is broken by the operator when the device fault or alarm status arises. With both red and green LED indicator - During normal operation, the Green LED is on. When device fault or alarm status arises, the Green LED will be cut off and Red LED will be on. No LED indicator 2.0 EXPLOSION-PROOF LABELING All products have a rating label, which carries the following important information: Product order no.: e.g. CP125SNNNNARD (Refer to the datasheet for product order selection) Input voltage: <30 Vdc/ 6 amp or <250 Vac/ 11amp Code: Exd IIC T6 Gb Ex tb IIIC T85 C T.amb -40 C to +70 C ATEX Marking: Gas Group and Category: II 2GD CE Mark: Warning: DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT Finish product serial no. Note : exact information is given on the actual label, ref also example on page 1. 3.0 TYPE APPROVAL STANDARD The CP/ PB 125 series products have been approved according the following standards: IEC/EN 60079 General Requirements IEC/ EN 60079-1 Flameproof Enclosure d IEC/ EN 60079-31 Dust atmosphere 4.0 ZONES, GASGROUP, CATEGORY AND TEMPERATURE CLASSIFICATION The CP/ PB 125 series products have been certified Ex d IIC T6. This means that the units can be installed in locations with the following conditions: Area Classification: Zone 1: Explosive gas air mixture likely to occur in normal operation. Zone 2: Explosive gas air mixture not likely to occur, and if it does, it will only exist for a short time. Gas Groupings: Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene Equipment Category: 2GD Temperature Range: -40 O C <Ta < 70 O C

5.0 INSTALLATION General Requirement Selection, Installation, Maintenance and repair of electrical apparatus for use in potentially explosive atmosphere should be done in according to IEC/ EN 6079-14/ -17/ -19. Product installation must be carried out in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer. Location The location of the unit should be made with due regard to the area where the unit is visible and can be easily operated. The unit should only be fixed to services that can carry the weight of the unit. If you need mounting plate, please contact EX TECH SIGNALLING SAS to ask the installation drawing of the mounting plate. (See Fig 1) 6.0 WIRING General Requirement EX TECH SIGNALLING SAS recommends that all cables and cores should be fully identified (suggest using cable from 2.0 to 2.5 mm²). Ensure that all nuts, bolts and screws are secured. Ensure that only the right and certified cable glands are used and earthed correctly. Ensure that only the right and certified stopping plugs are used to blank off unused gland entry points. In order to maintain the IP rating of the product, we recommend SS316L for this application. Cable Connection The cable connection is connected with the 8-hole terminal blocks marked T1-T8 located in the flameproof enclosure (See Fig 2). Cable connection should be carried out in accordance with relevant technical requirement. Remove End Cover Unscrew the four (4) M5 retained hex socket head screws. This will release the cover from the base and allow the cover to hang on the retaining wire strap. Before replacing the cover, check that the flameproof joints are clean and not damaged, the gasket is still retained in its groove. (See Fig 2) Mounting Fig 1 The product should be mounted on a vertical surface using four (4) fixing holes in the base. The fixing holes are designed to fit M5 Allen Screw only. Use of stainless steel fastener is recommended by EX TECH SIGNALLING SAS. Fig 2 CAUTION: Before removing the cover, ensure the power to the product is isolated. Remove the four pieces of M5

socket screws to open the cover. Twist the cover gently clockwise and anti-clockwise, whilst pulling away from the base, until it comes off. Replace the cover in similar way, but operate in reverse manner as above. 7.0 OPERATION There are two types of Manual Call Point availablewith/without flap. The product is operated by breaking of the glass using a hammer supplied by the manufacturer. For the one with the flap just lift it up first before breaking the glass. (See Fig 3) suitable heat resisting cable glands must be used, with a rated service temperature of at least 95ºC. If a high IP (Ingress Protection) rating is required, a suitable sealing washer must be fitted under the cable gland. When only one cable entry is used, the other one must be closed with an Ex d flameproof blanking plug, which must be suitably approved for the installation requirements. 9.0 END OF LINE MONITORING An end of line monitoring diode or an end of line monitoring resistor can be connected across the 24V+ and 0 terminals. If an end of line monitoring resistor is used, it must have a maximum resistance value of 3k ohms and a minimum wattage of 0.5 Watts; or a minimum resistance value of 1.2k ohms and a maximum wattage of 2 Watts. 10.0 MAINTENANCE Fig 3 Replacement of Glass To replace the glass after operation of the unit, unscrew the nut which fixes the glass. Take out the glass and remove any broken fragments from the unit. Check and make sure the gasket is in the nut. Place a new glass into the unit and replace the nut. (See Fig 3) CAUTION: The glass and any broken fragments should be removed carefully by wearing protective gloves to avoid any injury. During working life of the product, little or no maintenance is required. Stainless Steel is resistant to most of the acids, alkalis and chemicals. If abnormal or unusual environmental conditions occur due to accident etc., visual inspection is recommended. To avoid electrostatic charge build-up, only exterior of the product can be cleaned with a damp cloth. If spare parts are required, these can be supplied by EX TECH SIGNALLING SAS Company. If any failure occurs but not caused by human factor, the product can be returned to EX TECH SIGNALLING SAS for free repair or replacement during warranty period. 8.0 CABLE GLAND The CP125 series product has four (4) cable gland entries. Only cable glands approved for Ex d applications can be used, which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN 60079-14. SAFETY WARNING: If the CP/ PB 125 is used at high ambient temperatures, i.e. over +40ºC, then the cable entry temperature may exceed +70ºC and therefore

11.0 CONDITIONS FOR SAFETY USE i. This apparatus is suitable to be used only in ambient temperature as stated below: ii. iii. Other than product manufacturer, painting and surface finishing are not permitted by the third party. When used in dusty atmosphere, flameproof cable entry devices or stopping plugs have to be selected and installed carefully in order to maintain the IP rating (IP66/67) of the product. Type Ambient Temp. CP/PB-125-40 to +70 ºC Specific Condition for Use Repairs of the flameproof joints must be made in compliance with the structural specifications provided by the manufacturer. Repairs must not be made on the basis of values specified in tables 1 and 2 of EN/IEC 60079-1. Please contact Ex-Tech Signalling for further details. EX-TECH SIGNALLING SAS ZA Les Montagnes 355 rue de la Génoise 16430 CHAMPNIERS (France) Tel: +33 5 45 61 81 68 Fax: +33 5 45 23 29 46 Website: www.ex-tech.no E-mail : info@ex-tech.no

EX-TECH SIGNALLING SAS. ZA Les Montagnes 355 rue de la Génoise- 16430 CHAMPNIERS (France) Tel: +33 5 45 61 81 68 Fax: +33 5 45 23 29 46 Website: www.ex-tech.no E-mail: info@ex-tech.no

Attention Please: OMRON V-154-1A5 Mini SWITCH NC BLU R3 = 1.2K Ohm / R4 : 2.4K Okm Customize Project : OMRON V-154-1A5 Mini SWITCH NC BLU NO YLW NO YLW COM RED R3 RED LED Resistor R1 & R2 RED LED GRN LED COM RED R4 GRN LED R1 R2 T1 T2 T3 T4 T5 (B+) NO NC (B+) NO SUPPLY LINE USE T6 NC T7 T8 OUT 20mA 01-08/03/2016 Mise à jour 00-17/09/2015 Creation Revision - date Material Treatment Specifications Reason Scale : Drawing part 1 : 1 WIRING DIAGRAM CP 125_150 DOUBLE SWITCH WITH LED OR RESISTOR Drawn by : P. TRAUMAT Date : 17/09/2015 Project / N PO - - N Drawing CP 125_150 DOUBLE SWITCH WITH LED OR RESISTOR Index 01 A3 Size : Dossier Folio 1/1

Attention Please: R3 = 1.2K Ohm / R4 : 2.4K Okm Customize Project : Resistor R1 RED LED GRN LED OMRON V-154-1A5 Mini SWITCH NC BLU R3 RED LED NO YLW COM RED R4 GRN LED R1 T1 T2 T3 T4 (B+) NO NC COM T5 T6 COM GND 20mA SUPPLY LINE USE 01-08/03/2016 Mise à jour 00-17/09/2015 Creation Revision - date Reason Material Treatment Specifications Drawing part 1 : 1 WIRING DIAGRAM CP 125_150 SINGLE SWITCH WITH LED OR RESISTOR Scale : Drawn by : P. TRAUMAT Date : 17/09/2015 Project / N PO - - N Drawing CP 125_150 SINGLE SWITCH WITH LED OR RESISTOR Index 01 A3 Size : Dossier Folio 1/1

OMRON V-154-1A5 Mini SWITCH NC BLU OMRON V-154-1A5 Mini SWITCH NC BLU NO YLW COM RED NO YLW COM RED T1 T2 T3 T4 T5 T6 (B+) NO NC (B+) NO NC SUPPLY LINE USE T7 T8 OUT 20mA 01-08/03/2016 Mise à jour 00-28/09/2015 Creation Revision - date Reason Material Treatment Specifications Drawing part 1 : 1 WIRING DIAGRAM CP_PB 125-135-150 DOUBLE SWITCH WITHOUT LED AND RESISTOR Scale : Drawn by : P. TRAUMAT Date : 28/09/2015 Project / N PO - - N Drawing CP_PB 125-135-150 DOUBLE SWITCH WIHTOUT LED AND RESISTOR Index 01 A3 Size : Dossier Folio 1/1

OMRON V-154-1A5 Mini SWITCH NC BLU NO YLW COM RED T1 T2 T3 T4 (B+) NO NC GND SUPPLY LINE USE 01-08/03/2016 Mise à jour 00-28/09/2015 Creation Revision - date Reason Material Treatment Specifications Drawing part 1 : 1 WIRING DIAGRAM CP_PB 125-135-150 SINGLE SWITCH WITHOUT LED AND RESISTOR Scale : Drawn by : P. TRAUMAT Date : 28/09/2015 Project / N PO - - N Drawing CP_PB 125-135-150 SINGLE SWITCH WIHTOUT LED AND RESISTOR Index 01 A3 Size : Dossier Folio 1/1