SMARTBOARD For Roof Assemblies Designed to protect, strengthen and sustain roof assemblies
The ADVANTAGE was developed to meet the demands of challenging commercial roof assemblies; moisture/mold (food processing, athletic facilities, etc.), high traffic roofs (Solar, Green, Telecommunications/ Technology, etc.) and buildings requiring superior performance in fire protection, bonding and wind uplift (hospitals, schools, etc). Superior Bond s ability to securely bond to roofing membranes exceeds all other s. When compared to gypsum-based, adhesion performance* is as follows: Gypsum After 2 hours 1.5psi 1.8psi > 20% better After 24 hours 1.5psi 3.4psi > 100% better In unprimed applications, is greater than 30% better than gypsum-based s. A primer may not be required, however, is at the discretion of the Architect/Specification Writer. *As independently tested by a 3rd party. All s were primed for 2 hrs, as per industry norm. Gypsum results are an industry average. Enhanced Wind Uplift Performance Due, in part, to s exceptional bond performance as well as the composition of the board (extremely high compressive and flexural strength), it will deliver better wind uplift characteristics in adhesively attached roof membrane applications. This will deliver efficiency and cost savings on projects as Smartboard requires less fasteners and therefore less time to install. Gypsum Exceptional Strength s compressive and flexural strength exceeds all other s. When compared to gypsum-based, strength performance is as follows: Will Not Delaminate s formulation, as a specialty cement board, eliminates the possibility of delamination. Fire Resistant s will improve the fire resistance of the entire assembly from both internal and exterior fire. has a flame spread and smoke development rating of 0/0(a) and a Class A rating. (b). Water Resistant Moisture, Fungus and Bacteria Resistant is both Fungus and Bacteria Resistant, showing No growth (c). Environmentally Friendly Gypsum Compressive 700psi 2367psi > 200% better Flexural 95psi 1200psi > 1000% better Gypsum Water Absorption 10 5.33 50% better (% max as per ASTM C473) is made from approximately 50% recycled materials (10% post-consumer, 40% pre-consumer). s recycled content may qualify for LEED credits3+. 90 psf 9-10 8 > 10% better fasteners fasteners Notes: (a) As per CAN/ULC S102 and ASTM E84-05 (b) As per ASTM E108, CAN/ULC S107 & UL 790 (c) As per ASTM E-119-05, CAN/ULC S101-04, NFPA 251, UBC 7-1 & UL 263 1
APPLICATIONS The following are typical examples of roofing system applications with s and are presented for illustration only. Please consult with the designer, system manufacturer or other design authority for use and installation of any application. does not provide roofing design services and makes no warranties or representation with respect to any particular system or any components or materials other than s. It is the responsibility of the system manufacturer or design authority to determine the suitability of s, or the use of other materials with s, for any particular application. Cover Board Cover Board Cover Board COVER BOARD membrane rigid foam insulation OWSJ SUBSTRATE FOR VAPOR RETARDERS membrane vapor retarder OWSJ Hot Asphalt Substrate (Hot Mop) Hot Asphalt Substrate (Hot Mop) HOT ASPHALT SUBSTRATE Hot Asphalt (HOT Substrate MOP) (Hot Mop) hot mopped Metal or Tile Roof Thermal Roof Recover BarrierBoard Metal or Tile Roof Thermal Barrier ROOF RECOVER Metal BOARD or Tile Roof Thermal Barrier membrane existing roof surface HOT OWSJ ASPHALT SUBSTRATE (HOT MOP) can be mechanically fastened, bonded with mastic or adhesives or hot mopped to foam METAL OR TILE ROOF Metal or Tile THERMAL Roof Thermal Roof BARRIER Recover Barrier Board insulation. All hot-applied roofing systems can then be metal roof mopped directly onto the unprimed without vapor retarder concern for blistering or delamination. hot mopped rigid foam OWSJ insulation METAL OR TILE ROOF THERMAL BARRIER provides a thermal barrier in THERMAL BARRIER Thermal Barrier conjunction with a standing-seam metal or tile roofing Roof Recover Fire Board Barrier Underlayment system. It membrane also provides noise reduction and hail resistance. metal roof vapor retarder polystyrene insulation steel joist steel joist Fire Barrier Underlayment Designed to protect, strengthen and sustain Parapet roof Wall Substrate assemblies Fire Barrier Underlayment 2
Fire Barrier Underlayment FIRE BARRIER UNDERLAYMENT metal roof wood deck wood joist Parapet Wall Substrate VEGETATIVE GREEN ROOF growing medium plants moisture retention mat drainage layer protection fabric/root barrier waterproofing membrane insulation any structural deck Parapet Wall Substrate PARAPET WALL SUBSTRATE wall cap parapet wall framing exterior wall finish adhered flashing membrane sleeper PHOTOVOLTAIC (PV) ROOFING SYSTEM PV panels roofing membrane insulation any structural deck structural deck 5 SECUROCK SLOPE TO DRAIN parapet cap parapet nailer Smartboard fiber cant strip variable density cellular concrete masonry wall OWSJ NOT TO SCALE 3
TECHNICAL PROPERTIES Physical Test Test Method Units Results Water Absorption ASTM C473 Section 20 (Mean % water/volume) 5.33 Humidified Deflection (CSA) A82.20.3 (in) 0.11 Linear Variation ASTM D1037 Section (%).07 107 to 110 Flexural Strength ASTM C473 Section 7 (psi) 1200 ASTM C947 Nail Pull Resistance ASTM C473 Section 9 (lbf) 200 ASTM D1037 Section 15 (lbf) 200 Falling Ball Impact ASTM D1037 Section 21 No Damage Pass Compressive Strength ASTM C495 (psi) 2367 Compression Indentation ASTM D2394 Section 7-11 (psi) 3800 Weight (Density) (lb/ft 2 ) 3.28 Joint Depth ASTM C473 Section 17 (in) 0.06 Squaring ASTM C473 Section 15 (mm).112 Thermal Resistance ASTM C518 (btu.in/h.ft 2 F) (1.305K). R.42 Flame Spread and Smoke Development CAN/ULC S102 0/0 Flame Spread and Smoke Development ASTM E84-05 0/0 Fire Test ASTM E108, CAN/ULC S107 & UL790 Class A Non- Combustibility ASTM E-136-04 Non- Combustible Modulus of Elasticity ASTM C947 Mpa 4500 Freeze/ Thaw Resistance ASTM C947 50 cycles Exceeds Requirement Warm Water Resistance ASTM C1185 70% Pass Fungus Resistance ASTM G21-96 No Growth Bacteria Resistance ASTM G22-76 No Growth Tested in Accordance with ANSI/UL 1897 4
Fastener Patterns Other patterns are available from system manufacturers or testing agencies. Smartboard Building Products Inc. 2820 Fourteenth Avenue, Suite 101, Markham, Ontario, Canada L3R 0S9 t 905-761-1999 f 905-761-7693 e info@smartbrd.com www.smartbrd.com Manufacturing 615 Bowes Road, Unit 6, Concord, Ontario, Canada L4K 1J5 APPLICATION GUIDE SPECIFICATIONS This guide specification is available for download via our web site (www.smartbrd.com) to assist you in specification of. If you have additional questions or would like more information regarding this or other and systems, please contact Building Products at 905-761-1999. Product Information See smartbrd.com for the most up-to-date product information. Trademarks The following trademark used herein is owned by Product Warranty Product Warranty 30 Year Limited Warranty for Interior Applications 20 Year Limited Warranty for Exterior Applications Smartboard Building Products Inc. warrants its conform to Smartboard Building Products Inc. published specifications. The user shall determine the suitability of the product for their particular application. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARANTIES, ESPRESSED OR IMPLIED, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE NOT EXPRESSLY SET FORTH HEREIN. Smartboard Building Products Inc. and any seller s liability for damage hereunder shall not exceed the purchase price of the product. IN NO EVENT SHALL MANUFACTURER OR SELLER BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OF THIS PRODUCT BY BUYER OR BUYER S USER, OR ANY OTHER PERSON. Notification of any claim must be sent in writing to Smartboard Building Products Inc. within 30 days from the time the discovery of the problem. The notice should contain copies of any sales receipts, invoices or other documents which may show the date(s) of purchase and installation, a statement to how the product failed to meet our warranty and the amount of refund claimed. Notice We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. Note All described here may not be available in all geographic markets. Consult Building Products Inc. directly to inquire.