MSC Scroll Liquid Chillers

Similar documents
MAC-120HE-01 Air-Cooled Chiller

Cool Design for Homes and Offices

Condensing unit type EPSILON-ECHOS LE Technical information manual

MUELLER FALLING FILM CHILLERS

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Legacy Chiller Systems, Inc

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Nirvana. Cycling Refrigerated Dryers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Engineering Specifications

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

AFHX Guide Specifications

ECOCIAT. Domestic hot water heat recovery unit

FLASH TANK ECONOMIZER PRODUCT GUIDE

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Medical Air Systems: Scroll

SECTION AIR COOLED WATER CHILLERS

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Commercial Semi-Instantaneous Water Heaters

Liebert DS Thermal Management Unit

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

catalog Single Package Vertical Air Conditioners and Heat Pumps

DESIGN STANDARDS SECTION

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

AIR-COOLED CONDENSERS Technical Guide

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

REFRIGERATED COMPRESSED AIR DRYERS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Tim Sisson - Trane HVAC OVERVIEW

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Technical data. Danfoss DHP-A

Split System Cooling Product Data

Originators of the Flexible Water Tube design

Split System Heat Pump Product Data

Selection Tips For Air-Conditioning Cooling Systems

WATER-COOLED VERTICAL PACKAGED AIR CONDITIONERS 5-Ton through 30-Ton Capacity

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

Element D Services Heating, Ventilating, and Air Conditioning

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

marine/bespoke split applications

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Wiring Diagram. Diplomat 400V 3N.

VRV-WIII WATER-COOLED WATER-COOLED COMMERCIAL RENOVATION NEW CONSTRUCTION

Packaged Glycol Chiller Systems Operation Manual

How To Understand Evaporator

A. Section includes air conditioning units, controls and control panels.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

LOBOY 16 AIR CONDITIONERS

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Product Data. Split System Cooling F-EN. March 2015

Low Profile Unit Cooler

YCAA-B AIR COOLED LIQUID CHILLER

Air-Cooled Condensers

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Nordic Heat Pump Product Guide

Cooling kw Heating kw

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Split System Cooling Product Data

ice 3 FLUID TO FLUID HEAT PUMP

Heavy Duty Industrial Air Compressors

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

NEW JERSEY CENTER OF EXCELLENCE

Refrigerated Design Texas

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

CE6500 Energy Recovery Ventilator

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

ENGINEERING SPECIFICATIONS

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Samurai range. Screw Type Water Chillers Cooling Only & Heat Pump Versions

Commissioning - Construction Documents (Page 1 of 6)

LIEBERT CORPORATION Air Products. Model Number Reference Guide. Revision: April 2004

Tim Facius Baltimore Aircoil

Split units TH with hermetic compressors

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 ton Dual Circuits R-410A R-410A 1 R-410A

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Sanitary Type Electronic Flow Switches

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Refrigerated Compressed Air Dryers

TWE+TTA TWE+TWA T.R.

Split System Heat Pump Product Data

Transcription:

MSC Scroll Liquid Chillers n 15 60 Tons n Water-Cooled or Split System n Optional Heat Recovery n Optional Tank & Pumps n Specialized HVAC Systems n Industrial Process Cooling cooling solutions www.motivaircorp.com

The Motivair MSC water-cooled scroll chillers are designed for use in both the commercial and industrial markets. Built with the latest scroll compressor technology, controlled with either microprocessors or advanced PLC s and designed in a way that minimizes floor space, the MSC chillers provide a reliable and versatile cooling solution for a wide range of applications.

MSC Chiller Features & Benefits RELIABILITY & EFFICIENCY Proven reliable & efficient hermetic scroll compressors are incorporated in a compact, water-cooled package for industrial and commercial refrigeration. Compressors installed in pairs, in 1 or 2 independent refrigeration circuits, allow staged starting and turn-down for operational savings on variable heat loads. Standard equipment includes single or dual-circuit shell & tube evaporators (ASME stamp available) and 1 or 2 shell & tube cleanable water cooled condensers fitted with water regulation valves. NEMA 4 control panel includes: nonfused interlocked disconnect switch, fuses, overloads, contactors and microprocessor controller for all unit functions & alarms. AVAILABLE OPTIONS MSC chillers are available with several important and beneficial options to cover a wide range of applications: n Partial or total series heat recovery is available for all models with the addition of a brazed plate or shell & tube heat recovery heat exchanger. (See below) n Condenser-less chillers are available for use with remote aircooled condensers. Contact Motivair for correct selection. n Hot gas bypass option is available on one refrigerant circuit for low load operation without compressor cycling. n Insulated, closed storage tank and 1 or 2 primary circulation pumps, all mounted in a single factory package, pre-piped and wired, ready for immediate operation. n Noise suppression packages are available in 2 sound levels for operation down to 55 dba. n Standard microprocessor controls provide flexibility & security in operation while the optional PLC provides access to remote control via optional Ethernet/Bacnet/LON plug-in board. n Standard refrigerant is R-407C. Also available are R-22, R- 134a, and R-410 in 2008. Standard refrigeration equipment on all models includes suction & discharge compressor service valves, HP/ LP gauges & safety switches, liquid line solenoid valve, filterdryer, thermal expansion valve and complete refrigeration charge (except condenserless models which are shipped with Nitrogen holding charge). Optional Heat Recovery Circuit

Take control of your MSC Chiller... the microprocessor The standard Motivair microprocessor controller is a very powerful, yet userfriendly device. It offers a wide range of standard controls and alarms to suit any chiller application. It can control up to 4 stages of cooling in the chiller. Optional communication features include a serial card connection to a remote PC and a full-feature, remote wall-mounting controller, connected via an RS485 cable up to 500 feet away. For those applications requiring a higher level of remote communication, the PC02 advanced PLC system is available. PC02 Display Micro Chiller All controllers feature a plug-in wiring harnesses, so they can be quickly and easily changed without tools. MSC model Standard Optional MSC 1500-7200 Micro PC02 PC02 Board MSC PUMP/tank STations integrated or stand alone Pump/Tank Stations All MSC models can be supplied with internal simplex or duplex pumps, and a closed storage tank. Some chillers require an external pumping station and storage tank, which can be supplied separately by Motivair. Motivair designs and builds a full range of stand alone pump stations and tank/pump station packages (See Pump Station brochure). Because every large cooling system is typically unique, Motivair designs and builds each pumping station to order. Available options include: n Simplex, duplex or triplex pumps n Stainless steel water circuit n Automatic pump change over n Visible & audible alarms n Flow meters n Baffled tanks n Automatic water make-up n Pressure & temperature gauges n Isolation & check valves n NEMA 4 control box Stand Alone TPS 7.5 TNK n VFD pump speed control n High pressure pump option n Redundant pump packages

MSC specifications WATER-COOLEd msc 1500 2200 3000 3500 4000 5000 6000 7200 Cooling Capacity (1) BTU/h 198,070 235,635 293,690 358,575 413,215 474,685 580,550 710,320 Optional Heating Capacity (2) BTU/h 210,944 250,951 311,310 380,994 440,074 499,368 613,641 756,491 Nominal Flow GPM 40 47 59 72 83 96 117 144 Evaporator Pressure Drop PSI 4 3 4 3 4 3 4 3 Chilled Water Connections NPT 1 1/2 2 1/2 2 1/2 2 1/2 2 1/2 3 3 4 Compressor Qty. Qty. 2 2 2 2 4 4 4 4 Refrigeration Circuits Qty. 1 1 1 1 2 2 2 2 Capacity Steps Qty. 2 2 2 2 4 4 4 4 Electrical Supply V/P/Hz 460/3/60 Current FLA 25.7 29.3 33.5 41.0 50.6 58.6 66.4 82.0 MCA 28.9 32.9 37.7 46.1 53.8 62.2 70.5 87.2 MOP 41.8 47.6 54.4 66.7 66.4 76.9 87.2 108.0 Condenser Water @ 85 F (3) GPM 50 59 73 90 103 119 145 179 Condenser Water Connections Inches 2 2 2 2 2 2 2 2 Noise level (Sound Pressure)(4) dba 73 73 75 75 76 76 78 78 Weight - Transport Lbs. 1,345 1,367 1,466 1,521 1,984 2,028 2249 2,403 Weight - Operating Lbs. 1,411 1,422 1,521 1,587 2,072 2,116 2,359 2,579 Standard Dimensions Length - A- inches 76.7 84.6 92.5 84.6 84.6 84.6 94.5 104.3 Width - B- inches 31.9 31.9 31.9 31.9 31.9 31.9 31.9 32.7 Height -C- inches 55.1 55.1 55.1 55.1 59.0 59.0 59.0 65.0 (1) Water-Cooled rating for 54 F EWT; 44 F LWT; 85 F condenser cooling water (2) Series heat recovery with EWT, 115 F; LWT, 105 F (3) Condenser water flow based on 10 F rise across condenser (4) Sound pressure rating measured in an open field, 3 feet from the ground, 5 from chiller (4) Sound pressure rating measured in an open field, 3 feet from the ground, 5 from chiller MSC capacity correction chart Capacity Correction Factors (cf) (Multiply catalog capacities by correction factors) Chilled Water Temp. ( F) 23 32 40 45 50 55 60 cf1 F 0.63 0.77 0.93 1 1.1 1.2 1.3 Condenser Water temp. ( F) 75 80 85 90 95 100 105 cf2 F (MLC-A) 1.06 1.03 1 0.96.93.9.87 Glycol % (by weight) 0 10 20 30 40 50 Consult cf4 1 0.99 0.98 0.97 0.96 0.94 Motivair Dimensions 2008 Motivair Corporation. Motivair reserves the right to modify specifications without notice. Reproduction of this brochure in whole or part is prohibited.

Application, Integration & Solutions for all your Cooling Needs: MLC 60-500 tons air-cooled, water-cooled & split system chillers for industrial or HVAC applications. Available Integrated Free-Cooling. MHR 60-500 ton air cooled or watercooled chillers with simultaneous heat recovery. MPC 1/2-50 ton packaged air-cooled or water-cooled chillers for Industrial cooling, Medical cooling or custom HVAC applications. Includes integrated microprocessor, pump station, and storage reservoir. CTC 10-200 ton low temperature process chillers with integrated pump/tank stations. PTS Pump/Tank Stations for chillers and cooling systems. MOT & MEC Open draft or closed loop evaporative cooling towers for process cooling or HVAC applications. MFC Closed loop dry-coolers for process cooling and remote Free-Cooling applications. cooling solutions 25 John Glenn Drive Amherst, NY 14228 Tel: 716-689-0222 Fax: 716-689-0073 www.motivaircorp.com