How To Use A Gizmo 2.5 (Gizmo) With A Power Supply (Power Supply) And Power Supply For A Long Time (Power Source) (Power Cell) (Gigabone) (Microphone) (



Similar documents
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

API Marine. BMS Presentation. Ballast Measurement Systems

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

PAJ GROUP DEVELOPMENT OF ADVANCED MECHATRONICS

Digital inductive conductivity transmitter

Instruction Manual. T3111 T3111L T3111P T3111Ex

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Humidity, Temperature & Dew Point Transmitter with Replaceable Humi-chip Module H3 line and H5 line

Engineered Solutions

Electronic Control Devices The European Product Catalogue 2007

Electric Rotary Actuator - On/Off or programmable control actuator

How To Use A Ds340 (Dsp)

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

A-307. Mobile Data Terminal. Android OS Platform Datasheet

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Material test chamber with mechanical convection

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Mass Flow Meters & Controllers

A-317. Mobile Data Terminal. Android Platform Datasheet

Duct Humidity Transmitter

Mitel DECT Base Stations

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

HygroClip 2 (HC2) Humidity Temperature Probes User Guide

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Unidirectional Transmitter/ Receiver Units Introduction

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

How is Dew Point Measured Reliably?

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Problem / Solution. The problem:

General Purpose ph/orp Sensors

Long Distance Industrial Wireless Transmitters and Receivers

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Electronic Pressure Switch EDS 300

ENAiKOON ultrasonic fuel-level sensor

Adsorption air dryers ADS 1 215

Stainless Steel Dissolved Oxygen Electrodes

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Turbine Flow Sensor Series VTR

Kompressoren. Adsorption Dryer AD

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

USB-500/600 Series Low-Cost Data Loggers and Accessories

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

COMBIMASS. Technical Data COMBIMASS eco-bio +

Rense Product Range. Customized Humidity Solutions. Rense Product Range

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Buckeye Detection Systems Fixed Detection Systems Application Survey

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Climate chamber with illumination

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

T0118 T2118 T3118. Instruction Manual

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Temperature, hygrometry, CO and CO 2. probes for class 310 transmitters

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Test equipment for temperature and its reduction

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

3-Component Measuring System

Micro Motion 3098 Gas Specific Gravity Meter

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Capteur température et humidité pour HVAC

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Wireless Solutions BROCHURE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

testo 6383 Ethernet differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Heating oven with mechanical convection

RTD Temperature Probe for the Food/Pharmaceutical Industry

WEATHER STATION FOR SOLAR FARM MONITORING

VDL 53 - Vacuum drying oven for flammable solvents

Compact pressure switch Flameproof enclosure Ex d Model PCA

GSM COMMUNICATORS CATALOGUE

Combi switchbox with integrated 3/2 way pilot valve

Heating oven with mechanical control

Vacuum drying oven for non-flammable solvents

Plastic tube flowmeters Series PT/PS

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 4 v2.2 / Modification rights reserved EE210

Mini USB and USB 2.0-IP67 Connector System

Models SFP33 & SFP32 Pressure Transmitters

Measurement data monitoring system

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2

Technical Data. Dimensions

Electronic Control Devices The European Product Catalogue 2007

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Solenoid Valve Island Type 3965

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Gas Sample Probe Series SP

Transcription:

Order form alid from May 2015 HMT331 Humidity and Temperature Transmitter or wall mounting aisala HUMIAP Humidity and Temperature Transmitter HMT330 1 0 A 1 PRI 1 Transmitter type HMT331 1 2 Wall probe fixed A with short cable Probe holder plate recommended in selection 16 8 3 o additional temperature probe 0 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0...100%RH) 10 T (range: see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A if not needed 11 Analog output range o temperature output A ote: -20...+60 (-4...+140 ) - hoose option A, if no 0...+60 (+32...+140 ) K T output is desired 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) Please see note *) below 4 WLA (Wireless thernet) interface + antenna With short cable probe only 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5 m cable spare cable: 212142 Probe holder plate Recommended with short cable probe 5 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP 19 o probe installation kit A hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) *) ote! Simultaneous installation of LA and Universal A-power is possible only with a short cable probe. ALU HMT330 1 A 0 A 1 0 1 A 1 0 0 A 1 A A A A A 1

Order form alid from May 2015 HMT333 Humidity and Temperature Transmitter or general use aisala HUMIAP Humidity and Temperature Transmitter HMT330 3 0 1 PRI 1 Transmitter type HMT333 3 2 able length 2 m cable, +80 5 m cable, +80 10 m cable, +80 20 m cable, +80 Q 2 m cable, +120 4 5 m cable, +120 5 10 m cable, +120 6 3 o additional temperature probe 0 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range: see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A if not needed 11 Analog output range o temperature output A - hoose option A, if no -40...+80 (-40...+176 ) T output is desired -40...+120 (-40...+248 ) -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H 0...+60 (+32...+140 ) K 0...+100 (+32...+212 ) L 0...+120 (+32...248 ) M special : X 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP 19 Installation kit o kit A for probe uct installation kit item: 210697 able gland ARO M20 x 1.5 with split seal item: HMP247 hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 3 0 A 1 0 1 A 1 0 0 A 0 A A A A A 1

Order form alid from May 2015 HMT334 Humidity and Temperature Transmitter or pressurized processes aisala HUMIAP Humidity and Temperature Transmitter HMT330 4 0 1 PRI 1 Transmitter type HMT334 4 2 able length 2 m cable H 5 m cable 10 m cable K 3 o additional temperature probe 0 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range: see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A, if not needed 11 Analog output range o temperature output A -40...+80 (-40...+176 ) ote: -40...+120 (-40...+248 ) - hoose option A, if no -40...+180 (-40...+356 ) T output is desired -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H -20...+180 (-4...+356 ) 0...+60 (+32...+140 ) K 0...+100 (+32...+ 212 ) L 0...+120 (+32...248 ) M 0...+180 (+32...356 ) -60...60 (-76...+140 ) P 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP Stainless steel grid spare: HM47453SP 19 Installation kit itting body M22 x 1,5 for probe itting body PT 1/2" hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 4 H 0 A 1 0 1 A L 1 0 0 A 0 A A A A 1

Order form alid from May 2015 HMT335 Humidity and Temperature Transmitter or high temperatures aisala HUMIAP Humidity and Temperature Transmitter HMT330 5 0 1 PRI 1 Transmitter type HMT335 5 2 able length 2 m cable L 5 m cable M 10 m cable 15 m cable P 3 o additional temperature probe 0 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range: see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A, if not needed 11 Analog output range o temperature output A -40...+80 (-40...+176 ) ote: -40...+120 (-40...+248 ) - hoose option A, if no -40...+180 (-40...+356 ) T output is desired -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H -20...+180 (-4...+356 ) 0...+60 (+32...+140 ) K 0...+100 (+32...+ 212 ) L 0...+120 (+32...248 ) M 0...+180 (+32...356 ) -60...60 (-76...+140 ) P 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP Stainless steel grid spare: HM47453SP 19 Installation kit o kit A for probe Mounting flange item: 210696 hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 5 L 0 A 1 0 1 A 1 0 0 A 0 A A A A A 1

Order form alid from May 2015 HMT337 Humidity and Temperature Transmitter or high humidities aisala HUMIAP Humidity and Temperature Transmitter HMT330 7 0 1 PRI 1 Transmitter type HMT337 7 2 able length 2 m cable S 5 m cable T 10 m cable U 20 m cable R 3 Additional temperature o probe 0 probe 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range : see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A, if not needed 11 Analog output range o temperature output A -40...+80 (-40...+176 ) ote: -40...+120 (-40...+248 ) - hoose option A, if no -40...+180 (-40...+356 ) T output is desired -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H -20...+180 (-4...+356 ) 0...+60 (+32...+140 ) K 0...+100 (+32...+ 212 ) L 0...+120 (+32...248 ) M 0...+180 (+32...356 ) -60...60 (-76...+140 ) P 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP Stainless steel grid spare: HM47453SP 19 Installation kit o kit A for probe uct installation kit item: 210697 able gland ARO item: HMP247 Swagelok PT 1/2" item: SW12PT12 K Swagelok ISO 3/8" item: SW12ISO38 L Swagelok ISO 1/2" item: SW12ISO12 Y hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 7 S 0 A 1 0 1 A 1 0 0 A 0 A A A A A 1

Order form alid from May 2015 HMT337 Humidity and Temperature Transmitter with warmed probe or high humidities aisala HUMIAP Humidity and Temperature Transmitter HMT330 7 1 PRI 1 Transmitter type HMT337 7 2 able length 2 m cable S (dew point probe) 5 m cable T 10 m cable U 20 m cable R 3 Additional temperature o probe 0 probe 2 m cable 1 5 m cable 2 OT: select to measure 10 m cable 3 RH and T 20 m cable 7 4 Parameters Td+Tdf+x+pw (dew point probe only) (with additional T probe) 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA 9 and anada) ot IP65 Analog output channel (h1&h2&h3) 4... 20 7 Signal output ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range: see below) (ref. to parameters Td (-20...100 ) (-4...+212 ) selection above) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A, if not needed 11 Analog output range o temperature output A -40...+80 (-40...+176 ) OT: -40...+120 (-40...+248 ) - hoose option A, if no -40...+180 (-40...+356 ) T output is desired -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H -20...+180 (-4...+356 ) 0...+60 (+32...+140 ) K 0...+100 (+32...+ 212 ) L 0...+120 (+32...248 ) M 0...+180 (+32...356 ) -60...60 (-76...+140 ) P 13 Option for module o module slot 1 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output 3 hoose also analog output signal for h3 able gland M20 x 15 able bushings 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 Wall mounting plate 1 item: 214829 hemical tolerant composite sensor spare: HUMIAP180R 17 Humidity sensor type HUMIAP180R omposite sensor with chemical purge HUMIAP180R spare: HUMIAP180R omposite sensor for fuel cell applications HUMIAP180R spare: HUMIAP180R omposite sensor HUMIAP180 spare: 229011SP 5 omposite sensor with chemical purge HUMIAP180 spare: 229011SP 6 Heated catalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 L Stainless steel grid spare: HM47453SP Membrane SST filter for fuel cell applications spare: 214848SP 19 Installation kit o kit A for probe uct installation kit (for RH probe) item: 210697 Swagelok PT 1/2" item: SW12PT12 K Swagelok ISO 3/8" item: SW12ISO38 L uct installation kit (RH + T probes) item: 210697+215003 P Swagelok PT 1/2" + Swagelok PT 1/8" (RH+T) item: SW12PT12+SWPT18 Q Swagelok ISO 3/8" + Swagelok ISO 1/8" (RH+T) item: SW12ISO38+SW6ISO18 R Swagelok ISO 1/2" item: SW12ISO12 Y Splash/direct water protector for warmed RH&T and T probes HMT330WPA 1 hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 ISO9001 compliant factory calibration service item for 22 alibration calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 7 S 1 1 0 1 A 1 0 0 A 0 A A A A 1

Order form alid from May 2015 HMT338 Humidity and Temperature Transmitter or pressurized pipelines aisala HUMIAP Humidity and Temperature Transmitter HMT330 8 0 1 PRI 1 Transmitter type HMT338 8 2 able length 2 m cable for 232 mm probe 5 m cable for 232 mm probe W 10 m cable for 232 mm probe X 2 m cable for 454 mm probe 1 5 m cable for 454 mm probe 2 10 m cable for 454 mm probe 3 20 m cable for 454 mm probe 9 3 o additional temperature probe 0 5 isplay o display 0 raphical display with keypad 1 6 Power supply 10...35, 24 A 0 10..35, 24 A with galvanic isolation 1 Universal A-power (100...240 A) 2 Universal A-power (100...240 A) + US power cord 3 Universal A-power (100...240 A) + UR power cord 4 Universal A-power (100...240 A) + UK power cord 5 Universal A-power (100...240 A) + AUS power cord 6 xternal US A-adapter (for LA/WLA interface in USA and anada) ot IP65 9 7 Signal output Analog output channel (h1&h2&h3) 4... 20 ma 1 Analog output channel (h1&h2&h3) 0... 20 ma 2 - h1&h2 are mandatory Analog output channel (h1&h2&h3) 0... 1 3 - h3 is optional Analog output channel (h1&h2&h3) 0... 5 4 Analog output channel (h1&h2&h3) 0... 10 5 8 Analog output signals o 3rd analog output A 9 for h1, h2 and h3 RH (0... 100%RH) 10 T (range: see below) Td (-20...100 ) (-4...+212 ) Tdf (-20...100 ) (-4...+212 ) a (0...600g/m3) (0...262 gr/ft3) Tw (0...100 ) (+32...+212 ) dt (-10...+50 ) (14...+122 ) SPIAL efine quantity h1: h2: Optional h3: X X X efine scale h1: h2: Optional h3: hannel 1 hannel 2 hannel 3, choose A, if not needed 11 Analog output range o temperature output A -40...+80 (-40...+176 ) ote: -40...+120 (-40...+248 ) - hoose option A, if no -40...+180 (-40...+356 ) T output is desired -20...+60 (-4...+140 ) -20...+80 (-4...+176 ) -20...+120 (-4...+248 ) H -20...+180 (-4...+356 ) 0...+60 (+32...+140 ) K 0...+100 (+32...+ 212 ) L 0...+120 (+32...248 ) M 0...+180 (+32...356 ) -60...60 (-76...+140 ) P 13 Option for module slot 1 o module 0 LA (thernet) interface + 2 m cable (R45) 4 WLA (Wireless thernet) interface + antenna 5 3rd Analog output hoose also analog output signal for h3 3 15 able bushings able gland M20 x 1.5 A A power not connected 8-pole connector with 5m cable spare cable: 212142 17 Humidity sensor type eneral purpose and high chemical concentrations HUMIAP180R spare: HUMIAP180R A with chemical purge function HUMIAP180R spare: HUMIAP180R eneral purpose HUMIAP180 spare: 15778HM 1 with chemical purge function HUMIAP180 spare: 229011SP 4 atalytic humicap sensor with chemical purge HUMIAP180 spare: HUMIAP180 K PPS plastic grid spare: RW010276SP Stainless steel grid spare: HM47453SP 19 Installation kit all valve set (ISO 1/2") item: ALLAL-1 M for probe Pressure fitting PT 1/2" Pressure fitting ISO 1/2" hinese 21 P Accessories o A Service cable for P, RS232 (9 female connector) item: 19446ZZ MI70LIK software for Windows with RS232 service cable item: 215005 Service cable for P, US item: 219685 MI70LIK software for Windows with US service cable item: 219916 22 alibration ISO9001 compliant factory calibration service item for calibration: 216989 A ISO9001 extended temperature range calibration (-20, 0, +60 ) ALU HMT330 8 0 A 1 0 1 A 1 0 0 A 0 A A A A A 1