Transformer Solutions from Schneider Electric

Similar documents
Presentation of the France Transfo factories

SECTION DRY-TYPE TRANSFORMERS

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Together we create reliable products, thus ensuring development of power industry of continents.


Transformer Design & Design Parameters

Tasarım ve Baskı: AJANSBRAND A

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Power Transformers 10 to 100 MVA

Power transformers. Special transformers Railway

Distribution transformers. Green distribution transformer program Partnership for a sustainable environment

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

INTERNATIONAL STANDARD

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Multi-tap Transformers

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

Capacitor Voltage Transformer. Answers for energy.

Transformer oil cooler ALFA A02

SECTION SUBSTATION TRANSFORMERS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Electrical Maintenance Workshop

WINDING RESISTANCE TESTING

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

GUIDE FOR TESTING POWER TRANSFORMERS

Secondary Unit Substations

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

Modular Systems wind portfolio overview Power Collection and Grid Connection products

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

This section applies to the design and installation of transformers.

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Failure code manual. content

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

CAS 36 Ring Main Unit

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Practical Transformers: Operation, Maintenance and Testing

Power Transformers Small, Medium & Large

Transformer Bushings for GIS

Table of Contents. TransformerIQ FAQs 1

TRANSFORMATORY DYSTRYBUCYJNE I MOCY POWER AND DISTRIBUTION TRANSFORMERS POL ENG

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

ECOCIAT. Domestic hot water heat recovery unit

Primary and Secondary Electrical Distribution Systems

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Power Transformer Fundamentals: Design and Manufacturing

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

INTERNATIONAL STANDARD

Comparative study for cables and busbars

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Transformer Manufacturing Processes

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Oil and Coolant Circulating Heating System. Model - OCSM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Power Capacitor Units for improved power quality

Distributed Temperature Sensing - DTS

Brochure. Electric generators to power the world

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Presentation to CIGRE Next Generation Network. Visit of Seine substation

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

SPECIFICATIONS OF STATCOM TRANSFORMER (FOR 2.5 MVAR STATCOM)

Some important Indian Standards related to Transformer are as follows:

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Portable Air Conditioner

TIG INVERTER INSTRUCTION MANUAL

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

DRY TYPE TRANSFORMER

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

FAQs-Main switchboard design criteria

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

12. Inspection and Maintenance

S Y N C H R O N O U S G E N E R A T O R S

Step Voltage Regulators

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

SWIMMING POOL HEAT PUMP

THE VALUE OF POWER FACTOR TESTING

Commercial Gas Furnace Upflow

TARIFF CODE and updates standard

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Explosion proof enclosures

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

INTERNATIONAL STANDARD

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ScottishPower Distribution Cables & Equipment. Metal Theft

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Transcription:

Transformer Solutions from Schneider Electric

Table of Contents Title Page Minera MP Minera MP oil immersed medium power transformer 4 The right tune for your network 4 High quality level for more reliability 5 Customer benefits 5 Technical caracteristics 6 Minera Minera Oil-Immersed Transformers Up to 5 MVA - 36 kv 8 The right tune for your network 8 High quality level for more reliability 9 Customer benefits 9 Technical caracteristics 10 Trihal The new worldwide quality reference 12 Climatic test C3* 12 Environmental test E3 13 Fire withstand F1 13 Partial discharges 5 pc 14 Customer benefits 14 Prem-AL Aluminium Wound Transformers 16 Prem-AL: Aluminum Wound Xer 16 1

2

Minera MP Oil Immersed Medium Power Transformers Electrical Energy Wind Farm Refinery Mining, Minerals & Metals 3

Minera MP oil immersed medium power transformer Minera MP oil-immersed medium voltage power transformer is dedicated to all applications up to 100 MVA and is designed to meet your needs. Our broad range for Minera MP transformers includes: > Three phase units (single phase available on request) > Ratings up to 80 MVA, 50 or 60 Hz > Voltage insulation level up to 170 kv > Breathing or sealed type > A wide range of accessories > High capacity cooling options such as ONAN, ONAF, OFAF, OFWF or others upon request > Standard or low noise levels > Off-circuit tap changer (OCTC) or on load tap changer (OLTC) Minera MP oil-immersed transformers are also available upon request for special applications including rectifier, hazardous area transformers, reactors (shunt and series), auto-transformers, step-up transformers, Solar power plant, Wind Mill Application etc. Minera MP oil-immersed transformers meet the requirements of international standards such as ANSI, IEEE, IEC as well as other international/national standards. The right tune for your network Depending on your application and the different environmental influences you meet, we are able to deliver you a large variety of Minera MP transformers. Schneider Electric s R&D team has created special designs for all your particular needs: > Breathing type and sealed type, > For indoor application in buildings or industrial plants and in compact distribution substations, > For outdoor applications, > Normal noise level for urban or residential areas > Normal, low or very low level of losses As customer satisfaction is our main concern, we constantly improve our manufacturing process, thus we are able to speed up delivery time while ensuring that all ISO 9001, ISO 14001 and/or ISO 18001 requirements are met at each production step. To ensure this high level of quality, our Minera MP transformers undergo routine tests in accordance with international standards such as IEC, ANSI standards. We can also provide type tests or special tests on request. ISO 9001, ISO 14001 and ISO 18001 Transformers units certifications 4

High quality level for more reliability Our company follows a policy of continuous improvement taking into account the latest worldwide developments. This ensures that our transformers are state-of-the-art and fully compliant with the modern world s highest requirements: fast delivery time, improved quality and recycling capacities, reduced size and, on request, very low noise and losses values. Magnetic core The transformer s magnetic core is manufactured from a high grade, cold-rolled, grain-oriented silicon steel. The lamination stacking is step lap type. The magnetic core is generally a multi-layer circular cross section and the slitting and cutting of the magnetic core is made by automated machines. In order to reduce transformer sound level to a minimum, the magnetic core and its framework are carefully sized to minimize the vibrations and, in particular, magnetostriction effects, which constitute the main sources of sound in medium power transformers. Moreover, in order to reduce the no-load losses and / or the noload transformer current, the quality of the magnetic steel and the induction, together with the design of the magnetic core, are carefully chosen to meet the requirements. Tank construction The main tank construction type is panel radiator type. The corrugated wall tank is also available in some ranges. Radiators are welded or removable. Tank welding is done by qualified welders. To validate the oiltightness after complete assembly, the tank is leak tested under gas or liquid overpressure. Low voltage windings The low voltage winding material is copper or Aluminium according to the rated power. The shape of the conductor is rectangular or foil type. To obtain a controlled temperature gradient, cooling ducts are added in the coil. The low voltage winding is built around the magnetic core. An insulating barrier is wound or installed around the low voltage coil in order to provide an electrical separation between LV and HV coils. Surface protection One of our major quality commitment is to provide high-quality surface protection. The coating (painting) type is chosen in accordance with the environmental conditions considering the degree of pollution, humidity, etc. Zinc Spray / Hot dip galvanized Tank, HV/LV covers and conservator can also be provided. High voltage winding The high voltage winding material is copper or Aluminium according to the rated power. To obtain a controlled temperature gradient, the cooling ducts are added in the coil. High voltage coils are in long layers or disc type. Due to recent developments in the winding process, interlayer insulation and wire insulation have allowed the automation of the winding process. Tappings The tap changers allow voltage adjustment for a variation of the supply network voltages on the primary side of the transformer or for increasing or decreasing the secondary voltage. Tappings are provided on the primary winding connected to an off-circuit or on-load tap changer. The operating handle for hand operated tap changer is mounted outside. In general, tapping range for off-load tap changer is 3, 5 or 7 position and for onload tap changer it is from 7 to 27 positions. We provide tap position & range as per customer requirements. Customer benefits > Extremely versatile > Robust construction > High quality and reliability > Continuous improvement > Tailor made > Highly economical thanks to reduced operating and maintenance costs > Strong after sales support 5

Technical caracteristics Oil-immersed medium power transformers Manufacturing standards Rated power Voltage level Phases Voltage regulation Short circuit impedance Rated frequency Vector groups Material thermal class insulation Temperature rise Type of cooling Dielectric liquid Short circuit withstand ability Sound level Installations HV & LV terminals Accesories With oil conservator or sealed IEC, ANSI, BS, AS, GOST, IEEE, IS, BS, etc. 4 MVA - 100 MVA Up to 170 kv One or three phase unit With off-circuit tap changer or on-load tap changer On request as per customer requirement 50 Hz or 60 Hz Dy, Yy, Yd as standard, others on request According to IEC 60085 class A, and as per customer requirement Mean winding temperature rise: 65 K Top oil temperature rise: 60 K With ambient temperature in accordance with IEC 60076-1 The temperature of the oil cooling air should not exceed: 20 C yearly average 30 C monthly average during the hottest month 40 C at any time For others ambient temperatures, winding and oil temperature rise can be adapted ONAN (Oil Natural Air Natural) (ONAF, OFAF, ODAF, OFWF or ODWF on request) Mineral oil according to IEC or ANSI standard (silicon, synthetic ester or vegetal oil on request). The transformers are designed to withstand the thermal and dynamic effects resulting of a secondary short-circuit in accordance with IEC 60076-5. The measurement (A-weighted sound pressure LpA) and the calculation of sound level (A-weighted sound pressure LwA) are done in accordance with IEC 60076-10. The sound level requirements are in accordance with national standards. Indoor or outdoor HV terminals: plug-in or porcelain bushings LV terminals: busbars or porcelain bushings On request: cable boxes according to client / manufacturer standard or norm (i.e BS) requirements Standard: lifting lugs, earthing terminal, name and rating plate, oil filling plug, tap changer, bidirectional rollers if applicable. Standard for sealed transformers: filling pipe or gas filling valve, oil drain valve, oil thermometer, oil level indicator. Standard for transformers with conservator: oil level indicator, Buchholz relay, oil thermometer, dehydrating breather, terminal box, oil filling & draining valves, filtering valves. On request: pad lock / locking device for HV plug-in bushings, pressure relief device, pressure relay with contact, explosion vent, winding thermometer, sudden pressure relay, pressure monitor, rubber bag (only for conservator type), Gas analyzing purpose systems (such as Hydran), Seal-in Relay, Current Transformers for protection and measuring, Automatic Voltage Regulator Panel for OLTC, etc. 6

Minera Oil-Immersed Distribution Transformers Electrical Energy Wind Farm Oil and Gas 7

Minera Oil-Immersed Transformers Up to 5 MVA - 36 kv Depending on the methods and the standards applied in your country, a transformer should be best adapted to the structure of your distribution network while offering the most cost-effective solution. With a large industrial world-wide platform, we offer versatility and flexibility and are able to deliver you the oil-immersed distribution transformer to meet your needs. Whatever the transformer type you require, you will find your solution in Minera. Quality based upon years of experience With more than 80 years of experience and over two million oil-immersed transformers installed worldwide, you can be sure of investing in a proven technology, constantly enhanced in our competence centers. Your solution in Minera Our standard range of Minera transformers is available as: > Three phase units (single phase available on request) > With ratings up to 4 000 kva, 36 kv, 50/60 Hz > With conservator or hermetically sealed type > Ground, pad or pole-mounted > Naturally cooled (ONAN), air forced (ONAF) or other type of cooling upon request > With normal or low noise or loss levels We also offer (upon request) higher ratings up to 100 MVA, 170 kv and transformers for special applications (rectifier, hazardous area, earthing, welding, transformers with OLTC,reactors, solar power plant, wind mill application etc.). The right tune for your network Our company follows a policy of continuous improvement taking into account the latest worldwide developments. This ensures that our transformers are state-of-the-art and fully compliant with the modern world s highest requirements: fast delivery time, improved quality and recycling capacities, reduced size and, on request, very low noise and losses values. Depending on applications and environmental influences, you will require a different type of oil-immersed transformer. We can deliver every type of Minera: > Hermetically sealed or breathing type > For indoor applications in buildings or industrial plants and in compact distribution substations > For outdoor applications: ground mounted but also pad or pole mounted > Low noise level for urban or residential areas > Normal, low, or very low level of losses As customer satisfaction is our main concern, we constantly improve our manufacturing processes, thus we are able to speed up delivery times whilst ensuring a high level of quality. All our production sites of Minera oil-immersed transformers are ISO 9001, ISO 14001 and ISO 18001 certified.to ensure this high level of quality, our Minera transformers undergo routine tests in accordance with IEC standards. We can also proceed to type tests or special tests on request. ISO 9001, ISO 14001 and ISO 18001 Transformers units certifications 8

High quality level for more reliability Magnetic core The magnetic core of the transformers is manufactured from a high grade, cold rolled grain oriented silicon steel. The stacking of the laminations is either butt lap or step lap type. The magnetic core is generally of a multi-layer, circular cross section type, where the slitting and cutting of the magnetic core is done by automatic machines. In order to reduce the sound level of the transformer to a minimum, the magnetic core and its framework are carefully sized to minimize the vibrations and in particular, the magnetostriction effects which constitute the main sources of sound in distribution transformers. In addition, in order to reduce the no load losses and / or the no load current of the transformer, the quality of the magnetic steel and the induction together with the design of the magnetic core are carefully chosen to meet the requirements. Surface protection One of our major quality commitment is to provide high-quality surface protection. The coating (painting) type is chosen in accordance with the environmental conditions, considering the degree of pollution, humidity, etc. Zinc Spray / Hot dip galvanized tank, HV/LV cover and conservator may also be provided. Tappings Tap changers allow voltage adjustment for a variation of the supply network voltages on the primary side of the transformer, or for increasing or decreasing the secondary voltage. Tappings are provided on the primary winding and connected to an offcircuit tap changer. The operating handle for the hand-operated, off-circuit tap changer is mounted outside. The standard tapping range is ±2x2.5%. However we can provide tapping range as per customer requirement. For adjustment operations, the transformer needs to be de-energized. However, on Customer benefits request for special applications, an on load tap changer can be provided. High voltage winding The high voltage winding material is either copper or aluminum: the choice depends on the load losses and on the rated power. The shape of the conductor is either of a round or rectangular type. To obtain a controlled temperature gradient, cooling ducts are added in the coil. High voltage coils are in long layers or of disc type. Due to recent developments in the winding process, interlayer insulation and wire insulation have allowed the automation of the winding process. Low voltage windings The low voltage winding material is either of copper or aluminum: the choice depends on the load losses, and on the rated power. The shape of the conductor is either round, rectangular or foil type. To obtain a controlled temperature gradient, cooling ducts are added in the coil. The low voltage winding is built around the magnetic core, and an insulating barrier is wound or installed around the low voltage coil in order to provide an electrical separation between the LV/HV coil. Tank construction The corrugated tank (cooling fins) is the most common type used for distribution transformers. The corrugated panels are welded onto the tank sides. Cooling radiators can also be provided on request. To validate the oil-tightness after complete assembly, the tank is leak tested under gas or liquid over-pressure. For hermetically sealed transformers, the cooling fins are designed to compensate for excessive over pressure and to limit the effects of cooling liquid dilatation. Hanging pole transformers are provided with a hanging device welded on the rear side according to national standards. Extreme versatility of the range High quality and reliability Economically optimized Capitalization of the losses Easy recycling Proven and permanently Optimized technology Reduced dimensions Solid construction Long life-cycle with low maintenance 9

Technical caracteristics Oil-immersed distribution transformers Manufacturing Standards Rated power Insulation level Phases Tappings Voltage regulations Short circuit impedance Rated frequency Vector groups Material thermal class insulation Temperature rise Type of cooling Dielectric liquid Short circuit withstandability Sound level Installations HV & LV terminals Accesories Hermetically sealed (without conservator) or with conservator ANSI, IEC, BS, AS, GOST, IS, IEEE etc. Up to 4 MVA (others rated powers on request) According to IEC U M =1.1, 3.6, 7.2, 12, 17.5, 24, 36 kv According to ANSI up to 36.5 kv 3-phase (single phase is applicable on request) ±2 x 2.5 % (or different range on request) With off-circuit tap changer (regulation with on-load tap changer is available on request) Uk=4 % for P 630kVA and UM 24kV Uk=4 or 4.5 % for P 630kVA and UM=36kV Uk=6 % for P > 630kVA 50 Hz (60 Hz on request) Yzn recommended up to 50kVA with UM 24kV Yzn recommended up to 100kVA with UM=36kV Dyn11 for all other rated power (any vector group according to IEC Standards) According to IEC 60085 class A Mean winding temperature rise: 65K Top oil temperature rise: 60 K with ambient temperature in accordance with IEC 60076-1. The temperature of the cooling air should not exceed: 20 C yearly average 30 C monthly average of the hottest month 40 C at any time For other ambient temperatures, winding and oil temperature shall be adapted. ONAN (Oil Natural Air Natural) or other type of cooling like ONAF, KNAN, KNAF, ODAF, OFWF, etc. Mineral oil according to IEC/ANSI Standard on request: silicon, synthetic ester, vegetable oil. The transformers are designed to withstand the thermal and the dynamic effects resulting from a secondary short-circuit in accordance with IEC 60076-5. The measurement (A-weighted sound pressure LpA) and the calculation of sound level (A-weighted sound level LwA) are done in accordance with IEC 60076-10 or NEMA - TR1. The sound level requirements are in accordance with national standards. Indoor and/or outdoor HV terminals: plug-in or porcelain bushings LV terminals: busbars or porcelain bushings On request: cable boxes according to client/manufacturer standard or norm (i.e BS) requirements - Standard: lifting lugs, earthing terminal, name and rating plate, oil filling plug, off circuit tap changer, bi-directional rollers if applicable (out of scope hanging pole transformer) - On request: pad lock/locking device for HV plug-in bushings and/ or tap changer, protective relay (DMCR, DGPT2, RIS,...), oil level indicator, oil thermometer, pressure relief device, filling valve, drain valve, explosion vent, winding temperature indicator, etc. Accessories for conservator: dehydrating breather, buchholz relay, drain plug, oil level indicator, etc. 10

Trihal Dry Type Cast Resin Transformer 11

The new worldwide quality reference Faithful to the vocation of feeling firsts, our full range Trihal dry type cast resin transformer is now gratified with the highest tests performances level: > C3* E3 F1 > Partial discharges 5pC Prove of its high grade design and manufacture quality, it will perfectly answer to a critical need for power companies to improvepersonnel safety and decrease the potential for loss of service to improve personnel safety. Climatic test C3* Climate C1 C2 C3 Lowest ambient temperatures: > Operation -5 C > Storage / Transport -25 C Lowest ambient temperatures: > Operation -25 C > Storage / Transport -25 C Lowest ambient temperatures: > Operation -50 C > Storage / Transport -50 C Thermal shock test proceeded under C2 Climatic test conditions but conducted at -50 C: > Temperature lowered to 50 C in 8 hours. > Holding at 50 C for 12 hours. > Thermal shock test at 50 C. > Dielectric tests and partial discharge measurements. > Visual inspection * C2 Thermal shock test carried out at -50 C 12

Environmental test E3 Environment E0 E1 E2 E3 Normal indoor installation > No condensation, > No considerable pollution > Occasional condensation > Limited pollution > Frequent condensation > Heavy pollution or combination of both > Relative humidity up to 93 % Nearly total condensation or heavy pollution or combination of both > Abnormal level of humidity up to 95% > According to new IEC 60076-16 Standard Test conducted in two parts according to IEC 60076-11 and IEC 60076-16 standards: Condensation test > 6 hours with 95% humidity (by indirect spraying of water of a conductivity of between 3.6 and 4 S/m) > Induced voltage test Humidity penetration test > 6 days at 50 C with 90%(+/-5%) humidity > Dielectric tests > Visual inspection Fire withstand F1 Fire F0 F1 > No special fire risk to consider > Except for the characteristics inherent in the design of the transformer, no special measures are taken to limit flammability Transformers subject to a fire hazard: > Self-extinguishing transformer fire > Restricted flammability required > Limited formation of fumes > Limited contribution with calorific energy to the source of fire The fire behaviour test is conducted in a specific test chamber according to procedure described in IEC60076-11 Standard: > 1 ethylic alcohol tank (sufficient quantity for 20 min combustion) burns under the tested coil > 1 panel heater in front of the tested coil > 1 reflector, concentric to the coil, is fitted opposite the panel heater The 2 fire-proof effects of the resin used in Trihal made it possible to observe: > Immediate self-extinguishing of Trihal as soon as the flames from the alcohol tank and heating of panel cease > Absence of halogen products, toxic emissions and opaque smoke 13

Partial discharges 5 pc Partial discharges 10 pc at 1.3 Un 10 pc at 1.3 Un > Maximum level of partial discharges measured during Routine Test > Maximum level of partial discharges measured during Special Test according to IEC 60076-11 Standard A partial discharge is the dissipation of energy caused by the build-up of localized electric field intensity. These phenomena, defined by IEC 60270, cause the insulation to deteriorate progressively and can lead to electrical breakdown. Integrity of the insulation of a transformer is confirmed during Partial Discharge Analysis and used as a tool to judge the state of the device and the quality of its manufacture. Prove of our quality advance, acceptance criteria applicable to all new Trihal are now 10 pc during Routine Test or 5 pc in case of Special Test ordered by the customer according to IEC 60076-11 Standard. Customer benefits C3* > Resitance to thermal shock > Highest performance under severe ambiant conditions > Superior behaviour on load changes > Extended service life E3 > Insensitive to total condensation or/and heavy pollution > Suitable to installation in harsh environment (e.g Wind turbine) F1 > Full safety for all type of buildings > Suitable to fire hazard area > Guarantee your safety 5 pc > Improve transformers aging > Extended service life 14

Prem-AL Aluminum Transformer 15

Aluminium Wound Transformers A comparison with CopperTransformers Efficiency Efficiency of a transformer depends on the losses of the transformer. The losses can be easily achieved with aluminum winding by using cross section of aluminum conductor 1.7 times than that of copper conductor. Reliability Reliability of copper and aluminium transformer can be same by using high standard manufacturing practices and prime grade materials. Low loss/energy Efficient Low loss / energy efficient transformers can be designed for both copper and aluminum transformers using latest design technology and prime grade materials. Schneider Electric has already conducted the short circuit test at ERDA, Vadodara for 950 kva 33kV Aluminium wound transformer for windmill application. The transformer has withstood the test and the results are same as that of the copper transformer having same 8 parameters. The overall dimension of the transformer has been kept as same as that of copper. Hotspot/Temp rise Hotspot & temp, rise of transformer is purely dependent on gradient of winding and cooling system provided. These parameter be maintained same for aluminum and copper transformers. Short circuit withstand capacity Equal capacity of tensile strength can be achieved by using aluminum with 66% more cross-sectional area than copper. Weight & Compactness Aluminum transformers are lighter in weight compared to copper transformers. By using design optimization software Al Transformer size can be contained within > 30% of Cu Transformer. Cost Effective Aluminium has more stable market price in comparison to copper. This in turn ensures greater stability in transformer prices. Efficient Reliable Comparable Hotspot / Temp Rise Optimized Weight & Compactness Cost Effective 16 Prem-AL: Aluminum Wound Xer Rated power 250kVA up to 2500 KVA HV Insulation voltage up to 36 kv LV / MV Insulation voltage From 0.433 up to 33 kv With 170 kv BIL /AC 70 kv (IEC) Insulation Class Class A Frequency Vector Group 50-60 Hz DYN11 / As per User Requirement Material Winding LV : Foil HV : PICC Standard IS 2026 / IEC 60076 Cooling System ONAN Indoor /Out Door Installation

Make the most of your energy SM Schneider Electric India Pvt. Ltd. Corporate office 9th Floor, DLF Building No.10, Tower C, DLF Cyber City, Phase II, Gurgaon - 122002, Haryana Tel: 0124 3940400, Fax: 0124 4222036 www.schneider-electric.co.in Customer Care Centre : Toll-free numbers: 1800 180 1707, 1800 103 0011, General number: 0124 4222040, Email: customercare.in@schneider-electric.com