ROOF AND GUTTER DE-ICING SYSTEMS

Similar documents
RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions

COMMERCIAL & RESIDENTIAL MARKETS U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL mm mm Graphic pattern white.

Products and services

Industrial Control Solutions

INSTALLATION GUIDE HEAT TRACE WIRE SELF REGULATING HEAT CABLES

Engineered Heating Cable Systems

Preventing Ice Dams on Roofs

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Wintergard wet roof & gutter De-icing

metal Duil~ing manufacturers Association

Installation Instructions SELF-REGULATING (SR) ROOF AND GUTTER DE-ICING CABLES INDUSTRIAL AND COMMERCIAL SERIES

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Vision Home Inspection

SECTION STANDING SEAM METAL ROOFING

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

Retrofitting an Insulated Cold Roof

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

ACS-30-EU-EMDR-10-MOD

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Public Safety Advisory On Potential Roof Collapses

ROOFS, SNOW AND ICE DAMS

ABSeam Panel Overview and Installation Instructions

Making Your Home Ready For Solar Water Heating

Construction Technologies Career Field Pathways and Course Structure

STANDING SEAM METAL ROOFING PANELS

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Roofing Signs that Your Roof Needs Repair/Replacement

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Materials and Colors

Asphalt Shingle Application Requirements

Standing Seam Roof Systems

Product overview mm. 100 mm

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Shingle Installation Guide

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Section Page Section Page

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Electric Heat Tracing INSTALLATION PROCEDURES

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Ventilation for Cathedral Roofs: How Much Is Sufficient?

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

/ALP BuyLine Catalog

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Solar Panel Installations

THERMAL MANAGEMENT SOLUTIONS

Commercial Roof Management

Installation Manual. Self-Regulating Cables TECHNICAL HELPLINE

The Perfect Fit For Metal Retrofit

How To Plan Out An Array Of Solar Panels

Mineral Insulated Heating

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

CHAPTER 7: Building Systems ROOFING SYSTEMS

Roofing Solutions for Alpine Regions

Winterizing Your Building

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

NGC-30-CR -CRM -CRMS -CTM -CVM

CertainTeed. Protecting Your Home From Ice Dams Homeowner s Guide

Roof Inspection. Summary Report

shingles, break down membranes and corrode flashings and drains. De-icers can also damage plants on the ground. What to do in an ice storm emergency

Building Owners Guide to a Duro-Last System!

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

How to Make Your Gutter Worries Go Away with a Reliable Gutter Protection System HUFFNPUFFINC.COM

Advanced Heat-Tracing Control System

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Total Home Inspection Checklist

SECTION STANDING SEAM METAL ROOF

Woodcrest. Shingles. Woodcrest Autumn Maple

Heating Cable. Construction

Self-Regulating Low Temperature Heating Cable

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Inspecting to a higher standard.

COMMERCIAL BUILDING APPLICATIONS

WATER LEAK DETECTION FIND LEAKS BEFORE THEY FIND YOU

Product Catalog. Extreme Roofing, Inc Rt. 982 Mammoth, PA

Los Angeles Fire Department Requirement No. 96 SOLAR PHOTOVOLTAIC SYSTEM

YOUR HOME DESERVES AN ENGLERT METAL ROOF

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Pipe Freeze Protection Design/Install Guide

ROOFS - Guidance for Repair, Maintenance and Replacement

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

Home Inspection Report

Water Management & Damage Prevention:

Coastal Metal Service

Transcription:

ROOF AND GUTTER DE-ICING SYSTEMS FOR COMMERCIAL BUILDINGS MAKE YOUR ROOF WINTER SAFE! ELIMINATE ICICLES AND ICE DAMS

Don t Let Ice Dams Damage Your Building HOW DO ICE DAMS AND ICICLES FORM? Ice dams and icicles form when accumulated snow on the roof melts and refreezes at the eaves and in the valleys. The ice dams and icicles form during the winter in these steps: Snow accumulates on the roof during winter snow storms. Snow compresses in the valleys and forms ice dams at the base of the valleys. Snow melt occurs between the accumulated snow and the roof surface. The melted snow runs down the roof to the eaves and refreezes forming ice dams and icicles. The water ponding builds up behind the ice dams. Continuous melting and refreezing of snow during the temperature cycles in winter increases the size and severity of the icicles and ice dams. Insulation Heat Source Snow Ponding Ice dam Snow Icicle Solar Radiation WHY DOES IT MATTER? Water ponding behind the ice dams can penetrate through your roof and cause: - Interior water damage leading to mold and mildew - Structural damage Roof ice dams and icicles pose many hazards to people and property - Randomly falling icicles are dangerous for pedestrians below - Ice dams and icicles can also damage the roof, gutters, decks and other personal property Aesthetics - Ice dams and icicles can stain or damage the shingles, facia, soffit and walls of your building. Insulation Ice dam Icicle POTENTIAL ROOF DAMAGE IN SNOW LOAD CONDITIONS Snow load is the amount of snow on a roof for a major portion of winter, whereas snow accumulation is the actual depth of snow on the ground from a single or series of snow storms. Both conditions play a role in the severity of roof and gutter challenges you may face, and what type of solutions you should consider. Heavy Annual Snow Fall in (cm) Annual Roof Snow Accumulation in (cm) Moderate Light Heavy over 100 (254) >15 (38) Moderate 20-100 (51-254) 6-15 (15-38) Light under 20 (51) <6 (15) 2

ROOF & GUTTER DE-ICING SYSTEMS Raychem roof and gutter de-icing systems include a suite of solutions that are designed to meet your application requirements. Typically the performance requirements of a system vary based on the severity of annual snow fall and the snow accumulation on a roof in a given area. Performance requirements of a system also depends on other design factors, including the weather patterns and temperature cycles, ambient temperatures, wind speeds, lake effects, elevation, northern/southern roof exposures, type of roof and roof material, overhang distance and roof features such as dormers, towers and valleys. 1. RAYCHEM RIM SYSTEM The Raychem Roof Ice Melt (RIM) System is a custom engineered concealed cable system that will put an end to ice build-up hazards. Raychem Roof Ice Melt (RIM) System is our premiere, highest performing, aesthetically elegant roof & gutter de-icing solution ideal for new construction or renovation of residential or commercial buildings, for all snow load areas. The RIM System consists of base panels to secure the heating cables in a fixed heat transfer position and offers a wide choice of aesthetically pleasing RIM cover panels. The RIM System includes panels specifically designed for eaves, valleys, channels, rakes and flat roof sections as shown below: RIM-C RIM-V RIM- V Composite Roof Shingle Standing Seam Metal Roof RIM-R Self-Regulating Heat Trace Cable RIM-E RIM-LPE RIM-S RIM-V VALLEY PANEL RIM-E EAVE PANEL RIM-R RAKE PANEL RIM-LPE LOW PITCH EAVE PANEL RIM-S SNOW MELT RIM-C CHANNEL PANEL 3

RAYCHEM RIM SYSTEM Depending on the snow load, we offer two different types of RIM systems: A. RIM SYSTEM - BEST FOR HEAVY SNOW LOAD AREAS RIM System is our premiere offering where design factors such as severe wind speed, elevation, temperatures and heavy snow load areas with roof snow accumulation over 15 (38 cm) and annual snowfall over 100 (254 cm) require the most robust system. The RIM System consists of RIM panels that use high wattage self-regulating cable providing high power output required for heavy snow load areas. RIM-Eave panels embed 3 runs of self-regulating heating cable for high power output requirements. Cover Panel 4 RIM2 System is our energy efficient offering for areas with less severe wind speed, elevation, temperatures and moderate snow load areas with snow accumulation 6 15 (15 38 cm) and annual snowfall 20 100 (51 254 cm). The RIM2 System consists of RIM2 panels that use lower wattage self-regulating cable providing energy efficient solution for moderate snow load areas. RIM2-Eave panels embed 2 runs of self-regulating heating cable providing sufficient power output required for moderate snow load areas. Cover Panel Self-Regulating Heating Cable Base B. RIM2 SYSTEM - BEST FOR LIGHT TO MODERATE SNOW LOAD AREAS Cover Panel Self-Regulating Heating Cable Self-Regulating Heating Cable Base Cover Panel Base Self-Regulating Heating Cable Base

ENGINEERED SOLUTION ENGINEERED SOLUTIONS As a part of a completely engineered RIM System (for retrofits), we offer the following services: Evaluate the situation with job site visits and architectural drawings (roof layouts and elevations). Prepare the design with individual circuit layouts, optimal control systems, and Raychem RIM materials. Supply the RIM materials, including: Engineering designs and installation instructions Metal base panel for attachment to the roof Safe, self-regulating heating cable Copper, zinc, Corten, or Kynar painted aluminum cover panel Accessory components as required (end caps, splice covers, etc.) Energy-efficient control system with BMS communication capabilities BENEFITS OF RIM SYSTEMS Prevents: Ice dam and icicle problems in eaves and valleys Roof damage or leaks caused by ice dams Provides: A one-time, maintenance-free solution The most energy efficient method available Self-regulating heating cable (UL Listed, CSA Certification) An aesthetically attractive solution with no visible cables A variety of colors and finishes Energy efficient UL control systems A long-term, maintenance-free solution Proven reliability with decades of successful operations 20-year warranty 5

DESIGNING A RAYCHEM RIM SYSTEM Our Pentair design professionals work with Customers architects, engineers, contractors, or building owners to understand the design requirements for a project, and design a system suited to yout project needs and budget. STEP 1 CUSTOMER PROVIDES PRELIMINARY DESIGN INPUTS For new construction, provide the following to our Pentair design professionals: -- Site plan locating walkways, decks and driveways STEP 5 CUSTOMER APPROVES FINAL SYSTEM DESIGN Approve the final system design and Field Support / Engineering Servcies, as applicable. STEP 6 PENTAIR PROVIDES THE MATERIALS FOR THE PROJECT Supply the RIM System materials to the customer, including: -- Metal base panel for attachment to the roof -- Safe, self-regulating heating cable -- Roof plan, power distribution -- Copper, or Kynar painted aluminum cover panel, or other custom materials -- Building elevations and recommendations -- Accessory components as required For retrofits, provide the following to our Pentair design professionals -- Complete the Estimate Form that will determine the basis for the design STEP 2 PENTAIR PREPARES A SYSTEM PROPOSAL Prepare the design with recommended scope, Raychem RIM materials layout and power requirements. STEP 3 CUSTOMER REVIEWS RIM SYSTEM PROPOSAL Review the proposal and either confirm the scope or specify changes to the proposal as needed for the RIM System installation you desire. Specify wiring for future RIM System additions, as needed (Note: A retrofit RIM system installation can cost 25 40% more than the cost of installing a RIM system initially) STEP 4 PENTAIR FINALIZES THE RIM SYSTEM PROPOSAL Implement the requested changes and make any final recommendations that are appropriate, like a control and monitoring solution or any relevant Field Support / Engineering Services that are best suited for the project. -- Energy-efficient UL approved control system, as applicable Provide the following details to the project s Electrical Engineer and/or Electrical Contractor: -- Engineering designs and installation instructions -- Junction box locations (per design recommendations) -- Control panel loads and location, circuit breaker sizing -- Material layout plans with circuit design loads and circuit breaker sizing -- Control panel layout and system testing procedures STEP 7 FIELD SUPPORT SERVICES PROVIDE PROJECT SUPPORT, AS APPLICABLE Perform the electrical evaluation/ testing procedure Train the installer to install the RIM system Commissioning, supervision and troubleshooting STEP 8 INSTALLER INSTALLS AND TESTS THE RIM SYSTEM Install the RIM System per the installation instructions as per design layouts Conduct control panel layout and system testing procedures Perform commissioning tests and complete warranty documentation We specialize in reviewing existing roof ice problems and creating customized RIM System solutions 6

RAYCHEM RIM IN ACTION BEFORE AFTER BEFORE AFTER BEFORE AFTER 7

RAYCHEM ICESTOP SYSTEM 2. RAYCHEM ICESTOP SYSTEM IceStop self-regulating heating cable system provides a continuous melt path at the eaves and valleys to safely drain the melting ice and snow off the roof and minimizes roof ponding problems. The IceStop self-regulating heating cable is then installed in the gutters and downspouts to route the snow melt to a safe location. The IceStop system is a simple cut-to-length solution that offers an advanced, high performing roof & gutter de-icing solution ideal for commercial buildings in light to heavy snow conditions. RayClic-PC Power Connection CONNECTION KITS AND ACCESSORIES State-of-the-art non-heat shrink RayClic connection kits and accessories are vital parts of the IceStop roof and gutter de-icing system. BENEFITS OF ICESTOP SYSTEMS Simple cut-to-length design Self-regulating energy efficient cable Safe to use on modern membrane roofs due to low cable temperatures Ideal for gutters of any size Reliable state-of-the-art connection kits Proven reliability with decades of successful operations 10-year warranty RayClic-LE Lighted End Seal Self-Regulating cable 8

RAYCHEM CONTROL SYSTEMS Raychem RIM and IceStop systems are controlled by state-ofthe-art control systems. RAYCHEM ACS-30 CONTROL SYSTEM The Raychem ACS-30 Control System is a state-of-the-art, multi-circuit electronic distributed control and monitoring system. It is supplied as a complete modular system, ready for field connections to convenient power distribution panels and temperature sensor input helping reduce the cost of electric heat trace cable installation. The advanced Raychem User Interface Terminal (ACS-UIT2) uses touch screen technology to provide fast, intuitive programming, monitoring and alarm annunciation. The Raychem ACS-30 may be integrated into your Building Management System (BMS) using the Raychem ProtoNode multiple protocol gateways. RAYCHEM HECS CONTROL SYSTEM The Raychem High Efficiency Control System (HECS) is designed to provide ground-fault protection to each circuit and to optimize energy requirements. The temperature controllers each use temperature sensors located in representative locations. The temperature controllers only turn on when the factory set ambient temperature sensor falls below the set point of 34 F. At temperatures below 34 F, the temperature controllers modulate the power to the RIM heating cables through solid state relays and maintain temperatures at 38-42 F. As temperatures drop below 34ºF and winds kick-up, the ambient temperature and wind speed controller modulates the heating cable output based on the weather conditions, resulting in significant energy savings. Since snow fall does not normally occur at temperatures below 10 F, the controller shuts off the RIM System and adds to the energy conservation program. 120% 100% Strong, Windy Conditions Weather Conditions Percent of Steady State of Power 80% 27-30 F with light winds 20-25% 27-30 F with strong winds 35-50% Design Output 60% Calm, Light Wind Conditions 20-25 F with light winds 40-60% 40% 20-25 F with strong winds 50-70% 10-15 F with light winds 60-90% 20% 10-15 F with strong winds 100% 0% 10 F 20 F Ambient Temperature 32 F HECS Performance for Different Ambient Temperatures and Wind Conditions 9

OUR PRODUCT RANGE ALLOWS YOU TO CHOOSE THE RIGHT SOLUTION FOR YOUR APPLICATION AND BUDGET! ICESTOP ROOF ICE MELT (RIM) Raychem's high performing, cut-to-length roof & gutter de-icing IceStop Heating Cable System is often specified for buildings and offer reliable state-of-the-art connection kits and control systems. These systems are ideal for commercial buildings in light to heavy snow load areas.. Ideal for these conditions/desired features: Large commercial buildings 120 V or 208-277 V; 12 W/ft@ 30 F Gutter >6" in width Hazardous Locations (Fuel Loading Areas) Fluoropolymer jacket Advanced control options Light to heavy snow load areas Raychem's premiere, highest performing, aesthetically elegant roof & gutter de-icing solution is designed with cables that are concealed in panels. Ideal for these conditions/desired features: All building types Better aesthetics with concealed cable 120 V or 208-277 V; up to 36 W/ft @ 30 F Gutter >6" in width Mechanical cable protection Available in 32 colors or copper Standard & Custom options Advanced control options ALL snow load areas WE CAN SOLVE YOUR ICE DAM ISSUES, BUT FIRST WE NEED A LITTLE BIT OF INFORMATION! By indicating your preferred solution and providing details about the building type, roof type, pitch, eave overhang distance, gutters, downspouts, valleys, voltage, circuit breaker size, what type of control you may be interested in..., we can best guide you to the right solution to fit your needs with a complete bill of materials that a distributor can quote on quickly. Eave Sloped roof shingle Metal roof standing seam Roof with RIM concealed panel Use the form on the right, or try our new on-line design tool: Raychem Roof & Gutter De-Icing Calculator available on www.pentairthermal.com in the Commercial or Residential Resources section. 10

ROOF & GUTTER SYSTEM ESTIMATE FORM Email completed form to your Pentair Sales Rep for a complete Bill of Materials and quote! Need Quote For: HEATING CABLE SYSTEM RIM CONCEALED SYSTEM BOTH CHECK OUT OUR ONLINE ROOF AND GUTTER DE-ICING DESIGN TOOL at www.pentairthermal.com by selecting the Commercial or Residential segment -> Resources and click on the Roof & Gutter De-Icing Calculator design tool. Contractor: Tear here. Offer the left side to the homeowner / building owner. Email the worksheet to your Raychem Sales Rep to get a complete Bill of Materials and quote! 2016 Pentair. H59869 07/16 1. Building Type & Conditions: (check all that apply) 2. Area Name: House Small shop / strip mall High-rise residential /multi-use bldg. Commercial building New Construction Retrofit Annual Snow Fall less than 100 inches more than 100 inches 3. Type of Roof: Sloped Roof Shingle Sloped Roof Shingle Sloped Roof Shingle Sloped Roof Shingle Metal Roof Seams 18 24 Metal Roof Seams 18 24 Metal Roof Seams 18 24 Metal Roof Seams 18 24 Don't Trace Roof Don't Trace Roof Don't Trace Roof Don't Trace Roof 4. Roof Pitch: Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 5. Length of Roof Edge: feet feet feet feet 6. Eave Overhang Distance: 0" 12" 24" 36" 0 12 24 36 0 12 24 36 0 12 24 36 (other) inches (other) inches (other) inches (other) inches 7. Gutters: Total Length: feet Total Length: feet Total Length: feet Total Length: feet Depth: inches Depth: inches Depth: inches Depth: inches Width: Inches Width: Inches Width: Inches Width: Inches No Gutters No Gutters No Gutters No Gutters 8. Downspouts: Number of Downspouts: Number of Downspouts: Number of Downspouts: Number of Downspouts: Average Downspout Length: ft Average Downspout Length: ft Average Downspout Length: ft Average Downspout Length: ft Single Run in Downspout Single Run in Downspout Single Run in Downspout Single Run in Downspout Loop Run in Downspout Loop Run in Downspout Loop Run in Downspout Loop Run in Downspout No Preference No Preference No Preference No Preference 9. Valleys: Number of Valleys: Number of Valleys: Number of Valleys: Number of Valleys: Average Valley Length: ft Average Valley Length: ft Average Valley Length: ft Average Valley Length: ft 10. Voltage: 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 11. Circuit Breaker Size: 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A 12. RIM Cover Panel: Kynar Painted Aluminum Kynar Painted Aluminum Kynar Painted Aluminum Kynar Painted Aluminum Copper Copper Copper Copper 13. Controllers: Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor 14. Notes: 15. Customer name: Company: Phone: Email: Project name: Project location: BUSINESS CARD

WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 RIM.Customercare@pentair.com EUROPE, MIDDLE EAST, AFRICA Tel: +32.16.213.511 Fax: +32.16.213.603 thermal.info@pentair.com ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2937 cn.thermal.info@pentair.com LATIN AMERICA Tel: +1.713.868.4800 Fax: +1.713.868.2333 thermal.info@pentair.com Pentair and IceStop are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2016 Pentair. EN-RaychemRoofGutterDeIcingRIMandIceStop-SB-H81855 07/16