Water Supply CORROSION PROTECTION. Section WO 05

Similar documents
COATING & WRAPPING OF UNDERGROUND PIPING

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Section Four: Linings and Coatings

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Fosroc Proofex Engage

LAMA has developed over the years a wide range of products that can be used in the waterproofing

DENSO WATERPROOFING SYSTEMS

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

WATERPROOFING FOR CONCRETE STRUCTURES

PAAM COMMERCIAL PRIVATE LIMITED

Ductile Iron Pipe Couplings

This data sheet describes the most common joining methods of steel water mains and the most important phases of installation.

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

MaxCell Technical Manual Design Parameters

INDEX. Sec. No. Items Page Nos.

Pipe Protection Tape System

GENERAL RUBBER LINING PRINCIPLES

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Rubber Lining for Projects

Corrosion protection linings. Issue 1

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Specification for Pipe Coating Repairs Offshore

BLACK JACK ALL WEATHER ROOF COATING

15/06/ Test procedure Current 3mA +/- 0.02mA. Section Cathodic Disbondment of the Coating

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Double Coated Urethane Foam Tapes

Peel & Seal Self-Stick Roofing Solutions

CATHODIC PROTECTION SYSTEM DESIGN

For drinking water pipe distribution systems, both main and supply lines Sewer and discharge pipe systems

Pipe Clamps and Accessories

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

#25 The Basics of Lightweight Conveyor Belting

Oil and Gas Pipeline Design, Maintenance and Repair

Trade Standard of Town Construction in PRC

TECHNICAL SPECIFICATION

POLYETHYLENE ENCASEMENT

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Please read the entire document before purchasing and installing any of these products

James M. Pleasants Company

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Polymeric membrane for roof waterproofing

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

Your guide to home maintenance. Flat Roofs

AND MEMBRANES ROOFING UNDERLAYS.

Introduction: Consumables - Part of the Identification System

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

DIVISION 4300 STORM DRAINAGE

DIY Poly Digester. What is Supplied in the Kit. Sketch of Arrangement

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

RUBBER SLEEVE KNIFE GATE VALVE

SIGRAFLEX . Properties. Applications

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Pipe Repair Products A complete selection for all types of pipe

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

SikaProof A Technology

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

BBA BRITISH. tanking. Application. Storage & Handling

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

Rehabilitation of corroded pipelines and pipes with FibaRoll

C A B L E P R O T E C T I O N

DOUBLE GATE KNIFE GATE VALVE

Puddle Flange. FRANK Puddle Flange

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

PR11 Plastic Repair, Adhesive

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

WATERPROOFING OF WET ROOMS


Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

8.7 Schluter -KERDI-LINE

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

3M Scotchcast Mine and Portable Cable Splice Kit

CREEK Technical Services, LLC

High Performance PSA in Sheet Membrane in Water Protection

Company and Product Presentation

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PRO-VAC 150-LG-75 VACUUM BAGGING FILM For low temperature cure up to 120 C

British Standard Underground Hydrant Range

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Transcription:

Water Supply CORROSION PROTECTION Section WO 05

CONTENTS A WO 05-S1 POLYETHYLENE SLEEVING FOR DI PIPE AND FITTINGS A WO 05-S2 ADHESIVE TAPE FOR SECURING POLYETHYLENE SLEEVING A WO 05-S3 STRAP & BUCKLE FOR SECURING POLYETHYLENE SLEEVING A WO 05-S4 PETROLATUM TAPE SYSTEM B WO 05-S5 BITUMEN TAPE SYSTEM C WO 05-S6 POLYOLEFIN HEAT SHRINK SLEEVES D EXTERNAL PROTECTION 1 POLYETHYLENE SLEEVING SYSTEM 1 PETROLATUM TAPE SYSTEM 1 BITUMEN TAPE SYSTEM 1 POLYOLEFIN HEAT SHRINK SLEEVE 2 Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual April 2009 TOC

WO 05-S1 POLYETHYLENE SLEEVING FOR DI PIPE AND FITTINGS STANDARD AS 3680:1989 Polyethylene sleeving for ductile iron pipelines AS 3681:1989 Guidelines for the application of polyethylene sleeving to ductile iron pipe & fittings DRAWING MATERIAL W1-2-17A Mainlaying application of sleeving for corrosion protection of DICL pipes W1-2-17B Mainlaying application of sleeving for corrosion protection of DICL fittings Polyethylene sleeving of ductile iron pipelines is intended to prevent surrounding aggressive soils/groundwater contacting the pipeline and causing corrosion. Free flow of ground water within the sleeving is not acceptable and would not be expected occur with properly installed sleeving. The effectiveness of sleeving is not impaired by the presence of condensate or small amounts of water that may be trapped within the sleeve. Non-regenerated linear low density polyethylene (nominal melt flow index of 1.0 max) DIMENSIONS Nominal size Layflat tube width (mm) Nominal size Layflat tube width (mm) Pipes Flanged fittings Pipes Flanged fittings 80 or 100 350 425 375 875 875 150 425 425 450 or 500 1100 1100 225 or 250 635 635 600 1270 1270 300 725 725 750 1500 1500 COLOUR Thickness: 200 μm minimum ± 20 μm Nominal size Sleeves per roll Nominal size Sleeves per roll 80 or 100 30 375 12 150 25 450 or 500 10 225 or 250 17 600 8 300 15 750 7 Water Blue, Recycled Water - Purple MARKING Manufacturer s name Applicable standard Date of manufacture (mm/yyyy) Number of sleeves per roll (on packaging) Nominal pipe size Batch (not in AS 3680) USE LIMITS WO 05-S2 STANDARD MATERIALS Do not use unrolled lengths of sleeving stored unprotected from sunlight for more than 7 days. ADHESIVE TAPE FOR SECURING POLYETHYLENE SLEEVING AS 3680:1989 AS 2400.12:1985 Polyethylene sleeving for ductile iron pipelines SAA Packaging code Part 12: Adhesive closing and sealing tapes Pressure sensitive adhesive tape for securing polyethylene sleeving is to have: minimum adhesion to steel of 10N for 25mm of width minimum breaking strength: 130N for 25mm of width PVC, polypropylene or polyethylene DIMENSIONS Width: 48 mm minimum Thickness: As appropriate to achieve minimum breaking strength WO 05-S3 STRAP & BUCKLE FOR SECURING POLYETHYLENE SLEEVING STANDARD AS 3680:1989 Polyethylene sleeving for ductile iron pipelines MATERIALS The strap is to have: minimum breaking strength of 500N maximum elongation of 5% at breaking Polypropylene or other material with similar chemical properties. DIMENSIONS Strap Width: 15 mm minimum Strap Thickness: 0.3 mm minimum The strap buckle is to: be of sufficient size and shape to accommodate appropriate strapping allow tension of strap to be maintained. Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual April 2009 Page A

WO 05-S4 PETROLATUM TAPE SYSTEM STANDARD DIN 30672 Coatings of Corrosion Protection Tapes and Heat Shrinkable Material for Pipelines The petrolatum system comprises four parts being 1) primer paste, 2) mastic, 3) petrolatum tape and 4) overwrap tape. The primer paste is first applied to surfaces free of water droplets and loose rust, scale, mud, paint etc. The mastic is then used to contour all sharp and irregular profiles to prevent bridging and subsequent perforation or tearing of overlying tape. Petrolatum tape having the heavy compound side down is then spirally wound about components without stretching. Tape is overlapped 55% for consistent full double thickness and tape is smoothed by hand to remove voids, ensure intimate contact and seal the tape overlaps. Finally the overwrap plastic tape is spirally wound without stretching to achieve 55% overlap for consistent double thickness. Overwrap provides mechanical protection against backfill, stray electrical current and leaching. MATERIALS Primer paste: Petrolatum (saturated petroleum based hydrocarbons), inert fillers and passivating agents Mastic: Petrolatum (saturated petroleum hydrocarbons), inert fillers, reinforcing synthetic fibres Petrolatum tape: Non-woven synthetic fabric, fully impregnated and coated with neutral petrolatum based compounds and inert fillers Overwrap tape: Plasticised PVC coated with a rubber based adhesive DIMENSIONS Petrolatum tape widths: 50, 75, 100, 150, 200 mm Overwrap tape widths: 50, 100, 150 mm MASTIC COVERAGE Nominal size Flanges pair (kg) Nominal size Flanges pair (kg) 80 2.15 300 8.65 100 2.85 375 10.6 150 4.30 450 12.85 200 5.70 500 14.30 225 6.50 600 17.25 250 7.25 750 21.35 Note: the above quantities are approximate only and depend upon application conditions PACKAGING Primer paste: Tins, boxes or drums Mastic: Blocks Primary Tape Rolls Overwrap Tape Rolls PACKAGING MARKING MARKING METHOD USE LIMITS Manufacturer s name or trademark Legible and durable marking For bolted joints with bituminous coatings (e.g. flanged joints, gibault joints, dismantling joints using galvanised bolts Do not use where stainless steel bolts are used Do not use to wrap welded joints of steel pipe having polyethylene coating, e.g Sintakote. Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual April 2009 Page B

WO 05-S5 BITUMEN TAPE SYSTEM STANDARD AWWA C209 Cold Applied Tape Coatings for the Exterior of Special Sections, Connections and Fittings for Steel Water Pipelines DIN 30672 Coatings of Corrosion Protection Tapes and Heat Shrinkable Material for Pipelines The bitumen tape system comprises of three parts being 1) primer liquid, 2) mastic strip, 3) tape. The primer paste is first applied to surfaces free of water droplets and loose rust, scale, mud, paint etc. The mastic is then used to contour all sharp and irregular profiles to prevent bridging and subsequent perforation or tearing of overlying tape. Tape having the heavy compound side down is then spirally wound about components without stretching. Tape is overlapped 55% for consistent full double thickness and tape is smoothed by hand to remove voids, ensure intimate contact and seal the tape overlaps. For specific requirements, such as the field repair of Sintakote coatings, an overwrap tape can be added to the bitumen tape system. MATERIALS Primer liquid: High softening point bitumen liquid hydrocarbon Mastic strip: Permanent plastic mastic Primary Tape: Non-woven synthetic fabric, fully impregnated and coated with neutral petrolatum based compounds and inert fillers Secondary Tape (where applied): Plasticised PVC coated with a rubber based adhesive DIMENSIONS Mastic strip widths: 50, 100 mm Primary Tape widths: 50, 100, 150 mm Secondary Tape widths: 50, 100, 150 mm PACKAGING Primer paste: Tins or drums Mastic: Rolls Primary Tape Rolls Secondary Tape Rolls PACKAGING MARKING MARKING METHOD USE LIMITS Manufacturer s name or trademark Legible and durable marking For bolted joints with bituminous coatings (e.g. flanged joints, gibault joints, dismantling joints using galvanised bolts Do not use where stainless steel bolts are used Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual April 2009 Page C

WO 05-S6 POLYOLEFIN HEAT SHRINK SLEEVES STANDARD AWWA C216 Heat Shrinkable Cross Linked Polyolefin Coatings for the Exterior of Special Sections, Connections and Fittings for Steel Water Pipelines DIN 30672 Coatings of Corrosion Protection Tapes and Heat Shrinkable Material for Pipelines Heat shrink sleeves are used for external corrosion protection of steel pipelines. They are used to protect exposed steel at joints after welding and to repair damaged external polyethylene or fusion bonded epoxy coatings on steel pipes or fittings. Heat shrink sleeves consist of two layers; a cross linked polyethylene sleeve which, when heated, shrinks to a predetermined dimension; and a heat sensitive corrosion protective adhesive pre-applied to the polyethylene sleeve, which softens on heating to adhere to the steel and prevent contact of steel with water. MATERIALS Sleeve: Irradiated and cross linked oriented impermeable polyethylene Adhesive coating on Mastic type heat activated adhesive which forms a protective layer to sleeve: prevent the ingress of water SLEEVE WIDTH BACKING THICKNESS 300, 450, 600, 900 mm Minimum backing thickness of 0.75mm (as supplied and not fully recovered) for use with Tyco Sintakote MSCL pipe SLEEVE LENGTH Nominal size Typical Length (mm) Nominal size Typical Length (mm) 80 355 300 1155 100 460 375 1350 150 660 450 1600 200 825 500 1750 225 925 600 2095 250 1005 750 2605 STORAGE PACKAGING MARKING Store in manufacturer s original packaging and leave unopened until required use Store in dry ventilated area Avoid exposure to direct sunlight, rain, dust or other adverse environments Avoid prolonged storage to temperatures above 35 C Manufacturer s name or trademark Product name and identification codes Batch or lot number Date of manufacture Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual April 2009 Page D

EXTERNAL PROTECTION EXTERNAL PROTECTION POLYETHYLENE SLEEVING SYSTEM Nominal Size Tyco Water DN (BlueBoss) 80 a 100 a 150 a 200 a 225 a 250 a 300 a 375 a 450 a 500 a 600 a 750 a PETROLATUM TAPE SYSTEM Denso 1,2 a NOTES 1. This system comprises Denso Multi-Purpose Primer, Denso Tape with a minimum of 55% overlap and Denso MP/HD Tape with a minimum of 55% overlap. Use Denso Mastic as necessary to contour sharp or irregular profiles. 2. Denso Mastic and Denso Tape have a maximum service temperature of 55C. For higher service temperatures to 75C, use Densyl Supersoft Mastic and Densyl Tape. BITUMEN TAPE SYSTEM (WELDED JOINTS ON PE COATED STEEL PIPE) NOTES Denso1, 2, 3 a 1. This system comprises Denso Primer D and Denso Ultraflex 1500 tape with a minimum of 55% overlap. Use Densopol Mastic strip as necessary to contour sharp or irregular profiles. 2. For Sintakote repairs, the use of an overwrap tape, Denso MP/HD, is recommended by Tyco in addition to the system described at Note 3 above. The overwrap tape should be installed with a minimum overlap of 10%. 3. For Sintakote repairs, a butyl rubber based primer, Densolen HT Primer can be used with this system in place of Denso Primer D. Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual January 2007 Page 1

EXTERNAL PROTECTION POLYOLEFIN HEAT SHRINK SLEEVE (FOR REPAIRS & WELDED JOINTS ON SINTAKOTE STEEL PIPELINES) Denso (Canusa Wrapid KLS Sleeve) I I = Interim Approval NOTES 1. Average service temperature should be less than 30C. Maximum service temperature 45C. Section WO 05 Power and Water Water Supply and Sewerage Approved Products Manual January 2007 Page 2