15/06/ Test procedure Current 3mA +/- 0.02mA. Section Cathodic Disbondment of the Coating

Size: px
Start display at page:

Download "15/06/2005 6 - Test procedure Current 3mA +/- 0.02mA. Section 12.8 - Cathodic Disbondment of the Coating"

Transcription

1 Document Name Standard Date / Edition Applicable Section Test Type AS AS Australian Standard Tests for coating resistance to cathodic disbonding CSA Z Z Z External Fusion Bond Epoxy Steel Coating for Pipe (fourth Edition) 15/06/ Test procedure Current 3mA +/- 0.02mA Fourth Edition - November 2002 Section Coating Section Disbondment of Strained Coating Value Tolerance Duration Logging Interval 1) 24 hrs 2) 28 days Voltage a) 1.5 V b) 3.5 V 65 degrees C Voltage 1.5 V (negative with a) 28 days b) 24 hrs Not exceeding 3 days or "as deemed appropriate" 28 days Summary of Disbondment Test standards Page 1 issued: 12/11/2013 by GJW

2 Z & Z Z External Polyethylene Coating for Pipe (third Edition) Z Third Edition - November 2002 December 2006 Fifth Edition Section Coating coating 12.8 Voltage a) 1.5 V b) 1.5 c) 3.5 V 65 degrees C Voltage (All voltages negative with the i) ii) iii) iv) a) 28 days b) 28 days c) 24 hours (All test times) i) 28 days ii) 24 hrs iii) 28 days iv) 28 days Summary of Disbondment Test standards Page 2 issued: 17/01/2011 by GJW

3 Z December 2006 Fourth Edition strained coating coating 12.3 Voltage use test i) from section 12.8 of the same standard Voltage a) 1.5 V b) 1.5 c) 3.5 V 65 degrees C a) 28 days b) 28 days c) 24 hours Summary of Disbondment Test standards Page 3 issued: 17/01/2011 by GJW

4 CSA Z Ext Polyethylene Z Plant Applied Polyethylene Coating for steel CSA Z FBE Z Plant Applied external fusion bond epoxy coating for steel pipe May 2010 Section Coating May 2010 Section Coating Voltage a) 1.5 V b) 1.5 c) 3.5 V 65 degrees C Voltage (All voltages negative with the i) a) 28 days b) 28 days c) 24 hours +/- 0.15V (All test times) i) 28 days within 24 Summary of Disbondment Test standards Page 4 issued: 17/01/2011 by GJW

5 CSA Z PU Foam CSA Z SERIES 2010 Z Plantapplied external polyurethane foam insulation coating for steel pipe CZA Standard Z Plant-applied external fusion bond epoxy coating for steel pipe May 2010 Sixth edition May 2010 Section Disbondment of Strained Coating Cross refers to CSA Z clause 12.3 and CSA Z clause disbondment of the coating Voltage (All voltages negative with the i) ii) iii) iv) Voltage (All voltages negative with the i) ii) iii) iv) /- 0.15V (All test times) i) 28 days ii) 24 hrs iii) 28 days iv) 28 days V (All test times) i) 28 days ii) 24 hrs iii) 28 days iv) 28 days Summary of Disbondment Test standards Page 5 issued: 17/01/2011 by GJW

6 CSA Z SERIES 2010 CZA Standard Z Plant-applied external polyethylene coating for steel pipe Z Plantapplied external polyurethane foam insulation coating for steel pipe Fifth Edition May 2010 First Edition May disbondment of strained coating 12.3 disbondment of the coating Cross refers to CSA Z clause 12.3 and CSA Z clause 12.8 Voltage use test i) from section 12.8 of the same standard Voltage a) 1.5 V b) 1.5 c) 3.5 V 65 degrees C a) 28 days b) 28 days c) 24 hours Summary of Disbondment Test standards Page 6 issued: 17/01/2011 by GJW

7 G (Re 2003) ASTM G Standard Test Method for Disbonding of Pipeline Coatings Subjected to Elevated Temperatures ASTM G 8-96 Standard Test Method for Disbonding of Pipeline Coatings G95-07(2013) ASTM G Standard Test Method for Disbonding of Pipeline Coatings (Attached Cell Method) NF A November 1992 French Standard NF A Reapproved 2003 Voltage -1.5 V at 25 deg C V at V 30 days Reapproved 2003 Voltage -1.5V V 30 days. Optionally other test periods such as 60 or 90 days 2013 Voltage -3 V DC with days electrode November 1992 Voltage 1500 mv negative with Calomel Electrode 1) ) ) ) Every 24 hours Others by Summary of Disbondment Test standards Page 7 issued: 17/01/2011 by GJW

8 NF A Standard NF EN ISO 15711:2003(E) French Standard NF A French Standard A confirms adoption of European Standard NF EN ISO Paints and varnishes Determination of resistance to cathodic disbonding of coatings exposed to sea water March 1988 March st Edition Appendix K TEST FOR ASSESSING THE RESISTANCE TO PEELING UNDER NEGATIVE POLARIZATION Polypropeylene Epoxy powder Voltage -1.5V 0.10% 7 days Every 24 hr Voltage polarisation potential mv (-1500 mv if saturated electrode used) Voltage polarisation potential mv (-1500 mv if saturated electrode used) 23 2) ) 2 days at ) ) 2 days at 60 First edition 2003 Voltage V +/-5mV 26 weeks Summary of Disbondment Test standards Page 8 issued: 17/01/2011 by GJW

9 ISO_ :2008 ISO /12/2008 FirstEdition Bituminous, petrolatum, wax and polymeric coating Heat shrinkable Coatings Fusion-bonded epoxy (FBE powder Coatings) Voltage -1500mV between working and electrodes or - 500mV if saturated electrode used Voltage -1500mV between working and electrodes or - 500mV if saturated electrode used Voltage 1) -1.5V 2) -3.5V 3) -1.5V 23 2) For PPT or 28 max by 23 2) For PPT or 28 max by 23 2) ) Summary of Disbondment Test standards Page 9 issued: 17/01/2011 by GJW

10 Liquid Coatings Polyolefin -based Coatings Elastomeric Coatings Voltage -1500mV between working and electrodes or - 500mV if saturated electrode used Applied V Applied V -1500mV between working and electrodes or - 500mV if saturated electrode used -1500mV between working and electrodes or - 500mV if saturated electrode used 23 2) For PPT or 28 max by 23 2) For PPT or 28 max by 23 2) For PPT or 28 max by Summary of Disbondment Test standards Page 10 issued: 17/01/2011 by GJW

A comprehensive range

A comprehensive range The professionals in coated pipelines A comprehensive range We have reduced our machine set-up times to offer a fast turnaround for fusion bonded epoxy, multi-layer and internal pipe coatings. All coating

More information

PIPELINE FIELD JOINT COATING AND FIELD REPAIR OF LINEPIPE COATING

PIPELINE FIELD JOINT COATING AND FIELD REPAIR OF LINEPIPE COATING RECOMMENDED PRACTICE DNV-RP-F102 PIPELINE FIELD JOINT COATING AND FIELD REPAIR OF LINEPIPE COATING MAY 2011 FOREWORD (DNV) is an autonomous and independent foundation with the objectives of safeguarding

More information

CATHODIC PROTECTION SYSTEM DESIGN

CATHODIC PROTECTION SYSTEM DESIGN CATHODIC PROTECTION SYSTEM DESIGN Presented By DENIS L ROSSI P.E. CORROSION ENGINEER New England C P Inc. Corrosion Fundamentals What is corrosion? It is defined as the degradation or deterioration of

More information

A World Class Manufacturer of Induction Bends

A World Class Manufacturer of Induction Bends A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction

More information

reduction ore = metal oxides metal oxidation

reduction ore = metal oxides metal oxidation Cathodic Protection and Interferences René Gregoor Madrid, June 18 th and 19 th 2009 1 Cathodic protection and interferences Corrosion Cathodic protection Protection criterion ON potential measurements

More information

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM 1. IS 15663(Part 1):2006 This code covers requirements and recommendations for the design, materials, construction and testing of pipelines made of steel

More information

2005 China International Oil & Gas Pipeline Technology (Integrity) Conference & Expo

2005 China International Oil & Gas Pipeline Technology (Integrity) Conference & Expo 2005 China International Oil & Gas Pipeline Technology (Integrity) Conference & Expo September 14-17, Shanghai, China ADVANCED ONSHORE AND OFFSHORE PIPELINE COATING TECHNOLOGIES Shiwei William Guan, Nick

More information

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS Shiwei William Guan, Ph.D. Vice President, R&D and International Business Madison Chemical Industries Inc. 490

More information

1-800-654-3872 1-405-273-6302

1-800-654-3872 1-405-273-6302 Anodeless Risers Transition Risers Compression Risers Riser Accessories Transition Risers and Transitions The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com Risers and Transitions:

More information

PRODUCT DATA SHEET DESCRIPTION:

PRODUCT DATA SHEET DESCRIPTION: DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance.

More information

The Comprehensive Coatings Service Provider to Industry

The Comprehensive Coatings Service Provider to Industry Coating Systems Excellent Engineering Solutions The Comprehensive Coatings Service Provider to Industry 2 Coating Systems Weir Coatings specialises in the application of high performance protective linings

More information

Apr 17, 2000 LAB MANUAL 1811.0

Apr 17, 2000 LAB MANUAL 1811.0 Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test

More information

Specification for Fusion Bonded Epoxy for External Pipeline Coating

Specification for Fusion Bonded Epoxy for External Pipeline Coating Specification for Fusion Bonded Epoxy for External Pipeline Coating TABLE OF CONTENTS 1.0 SCOPE...2 2.0 MATERIALS...2 3.0 APPLICATION...2 4.0 INSPECTION...5 5.0 COATING REPAIR...7 6.0 QUALITY CONTROL TESTS...8

More information

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability. FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability. APPLICATIONS Power supplies Printers Computers Battery chargers Automotive Converters CD-ROM. QUICK

More information

NORSOK STANDARD M-501 Edition 6 (2012)

NORSOK STANDARD M-501 Edition 6 (2012) Date: 2015-02-17 NORSOK STANDARD M-501 Edition 6 (2012) Surface preparation and protective coating Frequently asked questions INTRODUCTION NORSOK standard M501 Edition 6 was issued in 2012. The standard

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

This will also provide you with the knowledge to insure long life for your Investment

This will also provide you with the knowledge to insure long life for your Investment CONDUIT PIPE DRYING This Presentation will guide you to why systems fail! This will also provide you with the knowledge to insure long life for your Investment Drainable and Dryable System Design Trough

More information

COATING & WRAPPING OF UNDERGROUND PIPING

COATING & WRAPPING OF UNDERGROUND PIPING CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of Product: Pulse Withstanding Thick Film Chip Resistor-SMDP Series Size: /// official distributor of Pulse Withstanding Thick Film Chip Resistor-SMDP Series 1. Scope -This specification applies to ~ sizes

More information

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants PG&E Office San Francisco January 18, 2007 Craig K. Meier Corrosion Control Incorporated Corrosion process for tanks

More information

IR Edixeon Emitter. 1W Edixeon

IR Edixeon Emitter. 1W Edixeon High Power LED 1W Edixeon IR Edixeon Emitter Date:2006/06/01 Version:2.0 Device No. : 3-RD-01-E0009 Believe SRL Via Lago di Trasimeno, 21 - Schio (VI) - Italy TEL: +39/0445/579035 FAX: +39/0445/575708

More information

Section Four: Linings and Coatings

Section Four: Linings and Coatings Section Four: Linings and Coatings SPIRALWELD PIPE The majority of steel water pipe furnished today is specified to be provided with both an interior lining and an exterior coating. AMERICAN offers a wide

More information

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated) Approved 402;2521 1 2521 zinc epoxy ^(ValidationDate). 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a very high zinc dust containing product. It conforms

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 5 V DC, 1 V DC and 2 V DC DESIGNING For more than 2 years Vitramon has supported the automotive industry

More information

Master Panel 1000 W Wall

Master Panel 1000 W Wall Master Panel 1000 W Wall Product Description In order to generate an aesthethic outlook wall panels are generally produced as micro hedge. Besides, in connection points concealed screw is used which provides

More information

Efficient distribution of district heating and cooling. LOGSTOR pre-insulated pipe technology

Efficient distribution of district heating and cooling. LOGSTOR pre-insulated pipe technology Efficient distribution of district heating and cooling LOGSTOR pre-insulated pipe technology LOGSTOR pre-insulated pipe technology LOGSTOR has 50 years of experience in the development, production and

More information

Cathodic Protection. Remote Monitoring of Cathodic Protection on a Gas Distribution Network

Cathodic Protection. Remote Monitoring of Cathodic Protection on a Gas Distribution Network Cathodic Protection Remote Monitoring of Cathodic Protection on a Gas Distribution Network Author: Martin Alderson Northern Gas Networks Issued for UKOPA members CP measurements are very labour intensive

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Protection. Count On. You Can. 3M Scotchkote Infrastructure Protection Products. Meeting your coating needs for more than 50 years.

Protection. Count On. You Can. 3M Scotchkote Infrastructure Protection Products. Meeting your coating needs for more than 50 years. 3M Scotchkote Infrastructure Protection Products Protection You Can Count On 3M 50 Scotchkote years of protection Meeting your coating needs for more than 50 years. Header piping for a water purification

More information

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation

More information

Specification for Pipe Coating Repairs Offshore

Specification for Pipe Coating Repairs Offshore Specification for Pipe Coating Repairs Offshore Specification for Pipe Coating Repairs Offshore 1 of 6 Table of Contents 1.0 SCOPE... 3 2.0 REFERENCE DOCUMENTS... 3 3.0 MATERIALS... 3 4.0 EQUIPMENT AND

More information

Dispersions for the adhesive industry Innovative raw materials for numerous applications

Dispersions for the adhesive industry Innovative raw materials for numerous applications Dispersions for the adhesive industry Innovative raw materials for numerous applications Not all are the same! These days, almost all industries are dependent on innovative adhesive technologies. Modern

More information

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill. Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based

More information

IFC 070 Technical Datasheet

IFC 070 Technical Datasheet IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer

More information

Corrosion experiments in amine solutions

Corrosion experiments in amine solutions Corrosion experiments in amine solutions Andreas Grimstvedt Process technology SINTEF Materials and chemistry Wenle He Applied mechanics and corrosion SINTEF Materials and chemistry 1 Contents of presentation

More information

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

POLYURETHANE LINING AND COATING ON PIPE RAW WATER POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2

More information

3M Scotchkote 134 Fusion Bonded Epoxy Coating. Information, Properties and Test Results

3M Scotchkote 134 Fusion Bonded Epoxy Coating. Information, Properties and Test Results 3M cotchkote 134 Fusion Bonded Epoxy Coating Information, Properties and Test Results 3 Table of Contents PAGE 1 - Introduction...............................................................................

More information

Tecnosystem Group Srl - Pietro Fiorentini Spa

Tecnosystem Group Srl - Pietro Fiorentini Spa Tecnosystem Group Srl - Pietro Fiorentini Spa C. Calvi Tecnosystem Group Srl - M.H.G. Juinen Merrem & La Porte CATHODIC PROTECTION REMOTE MONITORING A.C. Influence Analysis of field tests with a new Data

More information

Testing Rules for Thermal Conductivity October 2015

Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.

More information

Master Panel 1000 R5 Roof

Master Panel 1000 R5 Roof Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage

More information

Physically Crosslinked Foam Insulation

Physically Crosslinked Foam Insulation Physically Crosslinked Foam Insulation Thermobreak is the original All in One flexible thermal insulation made from physically crosslinked closed cell polyolefin foam, factory fused to a reinforced 9um

More information

The Engineering Science of Oil Pipelines

The Engineering Science of Oil Pipelines The Engineering Science of Oil Pipelines From the Keystone XL pipeline project to spills and leaks in existing lines, pipelines are in the news. The SMCC has prepared this backgrounder on crude oil and

More information

No. 8940. EUROPEAN AGREEMENT CONCERNING THE INTERNATIONAL CAR RIAGE OF DANGEROUS GOODS BY ROAD (ADR). DONE AT GENEVA ON 30 SEPTEMBER 1957'

No. 8940. EUROPEAN AGREEMENT CONCERNING THE INTERNATIONAL CAR RIAGE OF DANGEROUS GOODS BY ROAD (ADR). DONE AT GENEVA ON 30 SEPTEMBER 1957' 1975 United Nations Treaty Series Nations Unies Recueil des Traités 435 [TRANSLATIN TRADUCTIN] No. 8940. EURPEAN AGREEMENT CNCERNING THE INTERNATINAL CAR RIAGE F DANGERUS GDS BY RAD (ADR). DNE AT GENEVA

More information

District Cooling Best Practices Piping Systems

District Cooling Best Practices Piping Systems District Cooling Best Practices Piping Systems International District Cooling Conference January 14-17, 2007 Abu Dhabi, United Arab Emirates Bryan Kleist Agenda Chiller Water Piping Materials Pipe Insulation

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections

More information

CORROSION PROTECTION BY COATINGS FOR WATER AND WASTEWATER PIPELINES

CORROSION PROTECTION BY COATINGS FOR WATER AND WASTEWATER PIPELINES Water and Wastewater Program West Virginia University, PA May 15, 2001 CORROSION PROTECTION BY COATINGS FOR WATER AND WASTEWATER PIPELINES Shiwei William Guan, Ph.D. Vice President, Research and Development

More information

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

German Cathodic Protection REMOTE MONITORING AND CONTROL

German Cathodic Protection REMOTE MONITORING AND CONTROL German Cathodic Protection REMOTE MONITORING AND CONTROL Michael Kahle / 17-19. October 2011 / 1. NACE-Jubail Industrial Forum 2011 1. Brief introduction of GCP GCP - Competence in Cathodic Corrosion Protection

More information

REPORT OF A COATING FAILURE ON A 16-INCH OIL PIPELINE UNDER WET CO2 SERVICE

REPORT OF A COATING FAILURE ON A 16-INCH OIL PIPELINE UNDER WET CO2 SERVICE REPORT OF A COATING FAILURE ON A 16-INCH OIL PIPELINE UNDER WET CO2 SERVICE Klaus E. Kueter InterCorr International, Inc. 14503 Bammel-N. Houston, Suite 300 Houston, TX 77014 David E. Hendrix The Hendrix

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

SPACE CHARGE ACCUMULATION UNDER THE EFFECTS OF TEMPERATURE GRADIENT ON SOLID DIELECTRIC DC CABLE

SPACE CHARGE ACCUMULATION UNDER THE EFFECTS OF TEMPERATURE GRADIENT ON SOLID DIELECTRIC DC CABLE ISBN 978--658-9 Proceedings of the 6 th International Symposium on High Voltage Engineering Copyright c 9 SAIEE, Innes House, Johannesburg SPACE CHARGE ACCUMULATION UNDER THE EFFECTS OF TEMPERATURE GRADIENT

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015 DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT Jim Riley, Texas A&M University February 10, 2015 Piping at Texas A&M 2 History of Distribution Piping at Texas A&M Concrete reinforced

More information

Liquid Applied Internal Flow Coatings for Oil Transmission Lines

Liquid Applied Internal Flow Coatings for Oil Transmission Lines Liquid Applied Internal Flow Coatings for Oil Transmission Lines M R McDonnell E Wood Limited United Kingdom This paper will examine more closely the benefits to the Industry by lining Oil Pipelines. Introduction

More information

STRAIN GAGE INSTALLATION HOLE DRILLING

STRAIN GAGE INSTALLATION HOLE DRILLING Via Delle Calandre 63 50041 Calenzano (Florence) Italy Tel: +39.055.8826-302 Fax: -303 www.sintechnology.com info@sintechnology.com STRAIN GAGE INSTALLATION HOLE DRILLING How to install strain gages for

More information

Environmental Cracking of Carbon Steel Weldments in Corrosive Petroleum Refining Environments. of Impressed Current Deep Groundbeds

Environmental Cracking of Carbon Steel Weldments in Corrosive Petroleum Refining Environments. of Impressed Current Deep Groundbeds STANDARD PRACTICES Designation Title Item Number NACE No. 1/SSPC-SP 5 White Metal Blast Cleaning (RP0494-2006) 21065 NACE No. 2/SSPC-SP 10 Near-White Metal Blast Cleaning (RP0594-2006) 21066 NACE No. 3/SSPC-SP

More information

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions. UL325 Compliant Non-monitored IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment

More information

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO. SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.

More information

NACE Standards. Chinese Translation Product Number. Spanish Translation Product Number. Visual Aid/ Related Product Number. Product Number 21105

NACE Standards. Chinese Translation Product Number. Spanish Translation Product Number. Visual Aid/ Related Product Number. Product Number 21105 21105 Related RP0104-2004 The Use of Coupons for Cathodic Cathodic Protection Protection Monitoring Applications ANSI APPROVED. Addresses applications for cathodic protection (CP) coupons attached to buried

More information

Ductile Iron Pipe Couplings

Ductile Iron Pipe Couplings J-9 Pipe 1 2 Straight and Transition Ductile offer an easy and economical way of joining whether the is of the same nominal and/or type or different at each coupling. couplings will handle most of your

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

NI-ZN BATTERY SPECIFICATION

NI-ZN BATTERY SPECIFICATION NI-ZN BATTERY SPECIFICATION 252000 Model Name: AA2500mWh(Ni-Zn) Issued Date: Sept. 2010 NICKEL ZINC BATTERY SPECIFICATION 1.APPLICATION The applicable range: This specification is available only for the

More information

STANDARD SPECIFICATION SECTION 15257 STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED

STANDARD SPECIFICATION SECTION 15257 STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED STANDARD SPECIFICATION SECTION 15257 STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, installation, and testing of fusion-bonded

More information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use

More information

Salzgitter Industrial Supply Chain Concept for Offshore Wind Jackets

Salzgitter Industrial Supply Chain Concept for Offshore Wind Jackets Salzgitter Industrial Supply Chain Concept for Offshore Wind Jackets Cost Reduction Potentials in the Fabrication of Offshore Wind Jackets by Standardized Pipes and Pre-fabricated Components The facts

More information

External Corrosion of Oil and Natural Gas Pipelines

External Corrosion of Oil and Natural Gas Pipelines External Corrosion of Oil and Natural Gas Pipelines John A. Beavers and Neil G. Thompson, CC Technologies PIPELINES play an extremely important role throughout the world as a means of transporting gases

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

Chair: David Kroon Vice-Chair: Chuck Lawrence

Chair: David Kroon Vice-Chair: Chuck Lawrence CONFERENCE CALL MINUTES TASK GROUP 284 CATHODIC PROTECTION, GALVANIC ANODE FOR INTERNAL SUBMERGED SURFACES OF STEEL WATER STORAGE TANKS: REVIEW OF NACE SP0196-2011 ASSIGNMENT: To review and update NACE

More information

Worldwide tank building applications using PP-Sheets: The effect of Foaming on properties

Worldwide tank building applications using PP-Sheets: The effect of Foaming on properties Worldwide tank building applications using PP-Sheets: The effect of Foaming on properties Marcus Hoffmann 1, Dominic Müller 1, Marco Stallmann 1, Matt Curtis 2 1 Simona AG Teichweg 16, 55606 Kirn, Germany

More information

EXPERIMENT #9 CORROSION OF METALS

EXPERIMENT #9 CORROSION OF METALS EXPERIMENT #9 CORROSION OF METALS Objective The objective of this experiment is to measure the corrosion rate of two different metals and to show the effectiveness of the use of inhibitors to protect metals

More information

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13 TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL 23 21 13.19 Pre-Insulated Piping 4-8-13 MATERIAL SUBMITTAL JOB NAME: TEXAS A&M SAN ANTONIO CENTRAL ACADEMIC BUILDING & PATRIOTS CASA CONTRACTOR:

More information

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542 1.0 INTENT REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES 1.01 It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

PSC-A5 Solar Charge Controller Manual

PSC-A5 Solar Charge Controller Manual ( 5A, 12V/24V Output, Double Mode ) 1. Introduction: This controller is suitable for 12V and 24V solar photovoltaic system. The charge and discharge current is 5A. The maximum solar panel for 12V system

More information

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3 Polymer Termination An alternative termination material specifically designed to absorb greater levels of mechanical stress thereby reducing capacitor failures associated with mechanical cracking Mechanical

More information

CHLORATES AND PERCHLORATES

CHLORATES AND PERCHLORATES CHLORATES AND PERCHLORATES Amazingly, chlorates and per chlorates can be produced through a simple electrochemical process from simples salts. Sodium Chloride (table salt) and Potassium chloride (another

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT

DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT BACKGROUND AND PRODUCT DESCRIPTIONS Fracture Diagnostics provides state-of-the-art test equipment, utilizing the Rising Step Load testing technique.

More information

PROBLEM SOLVING FORUM

PROBLEM SOLVING FORUM 4 Dealing with Water Tank Blisters Amy Forsgren Swedish Corrosion Institute Stockholm, Sweden: Blistering of the paint system used in a steel water tank indicates that the steel surface was not cleaned

More information

Terminal Cleaning and Protection

Terminal Cleaning and Protection Terminal Cleaning and Protection East Penn offers the most complete line of terminal cleaning and protection products. Boots Heat Shrink Tubing Cleaner and Protection Sprays Terminal Protectors 33 PAGES

More information

Appendix A: Acceptable pipe and fitting materials

Appendix A: Acceptable pipe and fitting materials Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for

More information

STAR PIPE Polska S.A ul. Gdyńska 51 62-004 Czerwonak tel. +48 61 667 41 20 fax +48 61 667 41 38

STAR PIPE Polska S.A ul. Gdyńska 51 62-004 Czerwonak tel. +48 61 667 41 20 fax +48 61 667 41 38 THE ALARM SYSTEM The base of the system consists of two non-insulated copper alarm wires with section equal to 1.5 mm2, located inside polyurethane foam parallel to the conduit pipe, offset in relation

More information

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) At a glance Anodized aluminium with a stainless steel orifice. For measuring the consistency of paints Expressed in second (s) flow time. Can be converted into centistokes. Available with adjustable stand.

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Atomic Structure. Atoms consist of: Nucleus: Electrons Atom is electrically balanced equal electrons and protons. Protons Neutrons

Atomic Structure. Atoms consist of: Nucleus: Electrons Atom is electrically balanced equal electrons and protons. Protons Neutrons Basics of Corrosion Performance Metals Sacrificial anode manufacturer Specialize in aluminum alloy anodes All products made in the USA (Berks county, PA) ISO9001/2001 Certified Quality System Also traditional

More information

Cathodic Corrosion Protection of earthburried Pipelines. www.vc-austria.com

Cathodic Corrosion Protection of earthburried Pipelines. www.vc-austria.com Cathodic Corrosion Protection of earthburried Pipelines www.vc-austria.com Corrosion Problems? Conservation of Value Earthburried pipelines are usually expensive investments. In order to defend against

More information

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R 2 0 3 2

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R 2 0 3 2 S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y M o d e l : C R 2 0 3 2 Approved By Department Name Title Signature/Date (Remarks: The above table shall be filled by customer) POWER GLORY BATTERY

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001 .5mm Height 222 Package Top View Full Color Chip LEDs Technical Data Sheet Part No.: LL-R55RGBC- Spec No.: R55 Rev No.: V.2 Date: Mar./6/26 Page: OF 2 Features: P-LCC-6 package. White package. Optical

More information

New Developments in Adhesive Resins for Oriented Barrier // PP Film Applications. Development Center Materials Lab.

New Developments in Adhesive Resins for Oriented Barrier // PP Film Applications. Development Center Materials Lab. New Developments in Adhesive Resins for Oriented Barrier // PP Film Applications Development Center Materials Lab. HIROTAKA UOSAKI Contents 1. Characteristics of Adhesive Resins 2. New Developments in

More information

Combined Close Interval Potential Surveys and Direct Current Voltage Surveys for Increased Pipeline Integrity

Combined Close Interval Potential Surveys and Direct Current Voltage Surveys for Increased Pipeline Integrity Combined Close Interval Potential Surveys and Direct Current Voltage Surveys for Increased Pipeline Integrity John Peter Nicholson NACE Accredited Senior Corrosion Technologist Managing Director Cathodic

More information

HIGH VOLTAGE TEMPERATURE COMPENSATED ZENER REFERENCE DIODES

HIGH VOLTAGE TEMPERATURE COMPENSATED ZENER REFERENCE DIODES Available HIGH VOLTAGE TEMPERATURE COMPENSATED ZENER REFERENCE DIODES DESCRIPTION The 1N4057 through 1N4085A series of temperature compensated reference diodes provides a wide selection of nominal voltages

More information

Introduction to Pressure Pipe Rehabilitation with CIPP

Introduction to Pressure Pipe Rehabilitation with CIPP Introduction to Pressure Pipe Rehabilitation with CIPP Founded in early 1990 s RS Technik is a global leader in the rehabilitation of underground pipes RS Technik uses Cured-in- Place (CIPP) technology

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. P-14862 This is to certify that the Pipe System with Couplings with type designation(s) Megapress with SC-contour Issued to Viega GmbH & Co.