SFM-100/ MOS-LED. All in one stopped-flow system. Integrated absorbance spectroscopy. Spec-Lab software

Similar documents
73 Series Spectrophotometers

UV-Vis spectrophotometers

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Nederland België / Belgique

Agilent Cary 60 UV-Vis

MCAL Spectrophotometry. Spectrophotometry

GC-xt. The most flexible GC /GC-MS liquid sample injector

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

High-end stationary vacuum spectrometer. Innovation with Integrity OES

instruments Analytical Instruments for Science

Simplicity. Reliability. Performance

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

ORGANIC SAMPLE PREPARATION

Mitos P-Pump. product datasheet

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

Fixed and Adjustable Spacing Electronic Pipettes

Copyright by Mark Brandt, Ph.D. 12

Impedance 50 (75 connectors via adapters)

Zeiss 780 Training Notes

Discover Your Potential

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Alpha/Beta Counting Multi-Detector Systems (MDS)

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Transmitter Interface Program

Unleash Your Potential

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Appendix 5 Overview of requirements in English

VWR SPECTROPHOTOMETERS

Designed for multi-injector endurance testing, the

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Discover Your Potential

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Protocol: HPLC (amino acids)

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

DUAL PUMPS COMMUNICATIONS CABLE

Fluorescent Array Imaging Reader

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Shimadzu UV-VIS User s Guide

Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL.

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

QGA Quantitative Gas Analyser

Lab 2. Spectrophotometric Measurement of Glucose

UV-VISIBLE SPECTROPHOTOMETER

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

NanoPhotometer. Microvolume and Cuvette Spectroscopy

Spectral Measurement Solutions for Industry and Research

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

The Determination of an Equilibrium Constant

Recognition Kinetics of Biomolecules at the Surface of Different-Sized Spheres

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Introduction to Fourier Transform Infrared Spectrometry

Basler. Line Scan Cameras

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

Department of Aerospace Engineering Indian Institute of Science Bangalore

Physical Specifications (Custom design available.)

Quantitation of Peptides and Amino Acids with a Synergy HT using UV Fluorescence

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

d2 Quadra ENTERPRISE CLASS Professional Hard Disk DESIGN BY NEIL POULTON esata 3Gb/s FireWire 800 & 400 USB 2.0

Product Information D23m Digital I/O System

The Universal DAQ Device. Connect and measure immediately!

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

The Convenient and Compact CR System for Veterinary Practices

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Global Value 7. Productivity Suite for GammaVision. Optimizing Gamma Spectrometry Processes through Secure Data Management and Measurement Automation.

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

The convenient and compact CR system for veterinary practices

Carbon Tech Series GS8 GS4 GS2. GASOLINE injector equipment. The only way to test Gasoline Direct injectors. 300 Bars+

Lab #11: Determination of a Chemical Equilibrium Constant

DIODE PUMPED CRYSTALASER

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Material test chamber with mechanical convection

Chlorophyll Content Meter. CCM-200 plus

How To Use The Dc350 Document Camera

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Bringing good things ahead

LMS Test.Xpress Powering personal productivity

LynX TM Silicon Photomultiplier Module - LynX-A T1-A User Guide Understanding Silicon Photomultiplier Module for improving system performance

Information about ZEN 2009 Service Pack 2

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

The Sonometer The Resonant String and Timbre Change after plucking

Compressor Supreme Force Feedback User Manual

MINIMAT-EC-Servo Screwdriver Spindles

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

Transcription:

SFM-100/ MOS-LED RAPID KINETICS ANS SPECTROSCOPY All in one stopped-flow system Fast, simple single mix kinetics Integrated absorbance spectroscopy Spec-Lab software Optional Fluorescence Optional motorized drive

Mixing The SFM-100/MOS-LED is ideal for basic rapid kinetics research and teaching applications. Delivering research grade performance in low cost two syringe system with low sample consumption, excellent data acquisition specifications, and a user friendly design, the SFM-100/MOS-LED is the perfect system for teaching labs or basic research applications. Sample consumption as low as 30ul per shot with 20 μl dead volume provides great sample economy. Dead time to 8ms is typical in manual mode, and down to 5 ms with the optional motor drive. In manual mode mixing is done with a drive wheel system that has built in protection against overpressure. A stop syringe is used to trigger acquisition, and sets the shot volume. Mixing is done with our proven Berger-ball mixer, which delivers the best possible turbulent mixing, over the widest range of flow and viscosity conditions. Detection The MOS-LED is based on Bio-Logic s long experience with LED spectrometry. Single wavelength LED sources provide an excitation signal for absorbance or fluorescence. The signal is measured by a photodiode for absorbance, and an optional photomultiplier tube for fluorescence. Dual absorbance and simultaneous absorbance and fluorescence are possible. Software MOS-LED is controlled through Spec-Lab software. Bio-Logic developed Spec-Lab to bring innovative measurement and analysis tools to occasional users and students. Spec-Lab offers the best of simple operation and advanced features. GENERAL SPECIFICATIONS Single Berger ball mixing 8 ms dead time in manual mode - 5 ms with optional motor drive 30 μl sample per experiment 20 μl dead volume Variable mixing ratio Spec-Lab software included USB communication with PC Absorbance measurements standard - Fluorescence and dual absorbance optional 10 reasons to buy SFM-100/MOS-LED rather than classical manual stopped-flow Affordable Low sample consumption Plug and Play operation Compact User-friendly Integrated absorbance spectroscopy Optics/electronics optimized for kinetics Flexible and Modular Kinetics software included Teaching optimized SFM-100/MOS-LED

SFM-100/MOS-LED Drive wheel Stop block Stop syringe Switch valve Stop syringe/waste Release button A robust and precise stopped-flow In the standard SFM-100 both syringes are driven with a manual drive wheel. A precision brake and drive control gives shot to shot reproducibility better than 90%. A manual switch valve is used for a fast purge of the stop syringe. When the brake is released an LED indicates that new shot can be done. The mixing ratio is controlled by changing the drive syringe diameter, with mixing ratios from 1:1 to 1:10 is possible. A 18μl cuvette with double light path (1cm/1mm) is standard, and other cuvettes are available as options. Changing the cuvette is an easy 30 second operation. Wavelength Selection Traditional stopped-flow optical systems use a monochromatic light source, coupled to an excitation monochromator. The design is flexible, but bulky and expensive. The MOS-LED uses efficient and inexpensive single wavelength sources based on LED technology. Sources for specific applications, such as tryptophan, can be selected and quickly installed in the system. Compared to a bulky and expensive arc lamp source and monochromator, the LED source is major improvement in all important functions. The LED source in the MOS-LED gives better signal to noise performance than a standard bench spectrometers not designed for kinetics. The MOS-LED also automatically identifies the wavelength selected in Spec- Lab, and automatically calibrates the system. Drive block Drive syringes AN INNOVATIVE concept No more optical coupling issues No temperature artifacts No data acquisition speed limitation because of bench spectrometer or fluorimeter No trigger issues No more software issues with a software originally not designed for fast kinetics applications. Fast and Sensitive absorbance The MOS-LED uses a photodiode for absorbance measurements. Gain is automatically adjusted to operate in the optimum sensitivity range of the photodiode. Data can be collected every 100 μs and is sent to a PC through a USB port. A ultra fast electronic shutter is integrated to MOS-LED to protect sample from photo bleaching. Signals as low as 1x10-3 A.U. can be measured easily. DCIP reduction by 10 mm ascorbic acid followed at 525 nm by manual mixing k=180 s -1 (dead time measured at 7.8 ms, pre-trigger 2 ms).

OPTIONS Fluorescence & Dual Absorbance A second detection channel is optional with the SFM-100/MOS-LED, and adds three detection modes: smple fluorescence, simultaneous fluorescence and absorbance and dual absorbance. Designed specially for tryptophan fluorescence studies, it includes a photomultiplier tube, high energy 280nm LED, and cut-off filter. Pulse mode operation of the LED generates an intense excitation signal and acts as a virtual shutter to prevent photobleaching. A responsive acquisition circuit allows fast kinetics to be monitored with sampling to 400 μs per point. The PMT can be combined with another LED source for applications requiring fluorescence markers. Simultaneous absorbance and fluorescence is also possible, using a single LED for both detectors. Dual Absorbance The photomultiplier can be used as a second absorbance detector. Two excitation LEDS are used and switched on alternately. A single shot can be followed at two wavelengths simultaneously with a 100μs time base. This unique mode is fully controlled in Spec-Lab, which indicates which LED is connected to the photodiode, and which is connected to the PMT. Lyzozyme refolding by a 6 fold dilution: single shot in manual mode (0.5 mg/ml lysozyme in 6M GnD-HCL, excitation 280 nm, detection using 320 cut-off filter, 400 us sampling). Syringe Motor Drive The MPS-10 motor drive option adds improved shot to shot reproducibility and reduced dead time to the SFM-100. The user sets the pushing phase speed according to the syringe sizes installed. Dead time is reduced to 5 ms using the MPS-10, which makes SFM-100 capable of research grade experiments The MPS-10 is a user installable option, so it can easily be added to a basic system when needed. Temperature control Temperature control accessory can be added. The SFM-100 can then be connected to a circulating bath for temperature control. The observation head, syringes, mixer, and cuvette circulation path are linked to keep them at the same temperature. This reliable and design is used on our larger SFM models, and proven in daily use around the world.

Spec-Lab Software Easy to use full control for mixing, data collection, and analysis Spec-Lab controls the all of the mixing and detection functions of SFM-100/MOS-LED. It was designed to be easy for occasional users and students, Spec-Lab has the power and control needed by experienced kineticists. The user selects a detection technique, and software wizards guide him through the configuration steps. Intuitive selection of acquisition parameters Spec-Lab automatically identifies LED wavelength for one or two simultaneous LED s, and automatically adjusts gain for optimum signal to noise ratio. Data can be collected using a linear time base or using an innovative sampling mode which adapts the sampling rate to the speed of the reaction. Simple and powerful graphic interface Complete or partial traces can be selected for viewing or analysis. Tags can be placed along curves for direct reading of specific points. Spec-Lab saves multi-shot experiments within the same data file, where individual traces can be selected and averages calculated. Spec-Lab also includes smoothing functions, and tools for multiexponential fitting, rms noise measurement, normalization and subtraction. SFM-100/MOS-LED

specifications Why choose the SFM-100/MOS-LED for your lab? Robust Fast and sensitive Flexible Easy to use No software license Benefits for researchers and teachers Affordable Benefits for students Select exactly the configuration you need - absorbance only, absorbance/fluorescence, motor control, and excitation sources, for your current needs, and expand later as necessary. The SFM-100 / MOS-LED is affordable. It provides solid, research grade stopped-flow performance and optical features at a price comparable to existing basic stopped flow systems. As a teaching system, or a backup research system, the SFM-100/MOS-LED is an unbeatable value. The compact design of the SFM-100/MOS-LED make it easy to move from lab to lab, or to place in a fume hood or glove box. Plug and play setup eliminates the need for trained personnel to set up or move the system. Spec-Lab software is site licensed. Any user of the system can install Spec-Lab on their own PC and use it for shot design and data analysis away from the lab. Fitting tools and graphical options are available for report generation outside of the lab. Students can spend valuable lab time concentrating on experimental technique and data collection. specifications SFM-100 Stopped Flow Mixer Number of syringes 2 Number of mixers 1 Mixer type Berger-Ball Stop mechanism Drive mechanism Stop syringe Single ram, manual drive standard, Motor drive with optional MPS-10 Mixing ratio range 1:1 to 1:10 Ratio control Syringe change Trigger 5 to 0 V TTL trigger out Syringes Syringes material Glass (Teflon piston) Syringe size 5 ml standard (10 ml; 2.5 ml; 1 ml optional) Dead volume 20 µl Minimum injection volume 30 µl Observation head Ports Cuvette Minimum dead time Material General Dimensions Weight Power 2 detection, 2 excitation Standard is quartz cuvette with 1 cm x 1 mm light path 8 ms (manual drive) 5 ms (with optional MPS-10 motor drive) PEEK, Viton (Kelraz o rings optional) 32 x 11 x 13 cm SFM-100 29 x 22 x 15 cm MPS-10 5.6 kg SFM-100 5 kg MPS-10 110 V-220 V Bio-Logic, SAS 1, rue de l Europe 38640 CLAIX - France Tel.: +33 476 98 68 31 Fax: +33 476 98 69 09 www.bio-logic.info MOS-LED spectrometer Detection mode Absorbance standard Optional fluorescence, double abs., simultaneous fluo/abs. Absorbance detector Photodiode Wavelength range 280-800 nm Sensitivity in abs. mode 1.5 x 10-4 AU (524 nm, 1 ms sampling rate) Fluorescence detector Photomultiplier (optional) Sensitivity in fluorescence Noise 1.4% (measured with NATA 10 µm, mode exc. 280 nm, 320 nm cut-off, 400 µs sampling rate) LED excitation sources Wavelength General Dimensions Weight Communication Power Temperature control Temperature range Temperature control Software an PC Control software PC From 280 to 800 nm (contact factory) 37 x 17 x 21 cm 4.5 kg USB 110 V-220 V -10 C; +70 C External water bath circulator (optional) Spec-Lab (included) Requires Windows XP, Vista, 7 (32 bits) PC with available USB port (not included) Bio-Logic USA, LLC P.O. Box 30009 Knoxville TN 37930 - USA Tel: +1 865 769 3800 Fax: +1 865 769 3801 www.bio-logic.us Specifications subject to change without notice Brochure released on october 2010 - - 1008006 w w w. b i o - l o g i c. i n f o