Datasheet PDCSY-PA-699. Technical Overview. Features. Product warranty and total quality commitment.

Similar documents
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Digital inductive conductivity transmitter

PIEZOMETER AIRFLOW MEASURING RING

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Duct Humidity Transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

PRODUCT PROFILE FEATURES

How To Use A Flowmeter

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

Typical Aluminum GFM Mass Flow Meter

Relative and absolute pressure switch type 529

Wind Sensor W-RS485 with RS485 Interface

Instruction Manual Differential Pressure Transmitter

T7560A,B,C Digital Wall Module

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Proportional pressure regulators VPPE

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Control- and feedback head for integrated mounting on Robolux valves Type 2036

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Electronic Control Devices The European Product Catalogue 2007

How To Use A Corona Mdi 110

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Flow switches Series AD/VH

API Marine. BMS Presentation. Ballast Measurement Systems

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

OEM Relative and differential pressure switch type 605

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

OEM-EP Pressure Controllers

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Models SFP33 & SFP32 Pressure Transmitters

Plastic tube flowmeters Series PT/PS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic Pressure Monitoring New Products

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Battery Powered Thermal Mass Flow Meters for Gases

Contents. Document information

HD29371T - HD29V371T HD403TS - HD4V3TS HD103T.0

HMI display Installation Guide

Pressure switches for gas and air Pressure sensors

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Relative pressure transmitter type 520

Electronic Control Devices The European Product Catalogue 2007

KNX R. Rain Sensor. Installation and Adjustment

General Information... 2

Rosemount 333 HART Tri-Loop

How To Use A Ds340 (Dsp)

Series DFMT Digital Paddlewheel Flowmeter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Battery Powered Thermal Mass Flow Meters for Gases

Rackmount Intelligent Pressure Scanners

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Nokeval. User's Manual Models 301 / 302 / 305

ATL Fuel Level Sender Probes

Differential Charge Amplifier

Actuator for modulating control AME 435

Accessories SUNNY REMOTE CONTROL

Rosemount 333 HART Tri-Loop

H45 LED - Direct and indirect pendant

Series 6000 Torque measured metal bellow coupling

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HVAC Sensors Catalogue

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Pressure Switch for gas and air

GREISINGER electronic GmbH

Electric Rotary Actuator - On/Off or programmable control actuator

Electronic Pressure Switch EDS 300

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Capteur température et humidité pour HVAC

Thermal Mass Flow Meter (Series MST)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Temperature Transmitters ZTT series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

3DLevelScanner II TECHNICAL DATA SHEET

Series 510 Submersible Level Transmitters

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Highly efficient flue gas analyzer

Transcription:

Datasheet Multi-Range Air Differential Pressure Transmitter Technical Overview The range of differential pressure s incorporates a proved ceramic fulcrum lever technology. They deliver calibrated, temperature-compensated sensor signals, available as standard voltage or current outputs. They are ideal for registering low air flow in air conditioning systems and for the measurement of fine pressures in environmental, laboratory and clean room application (air and non corrosive gases). Features User adjustable measurement range IP65 Housing Compact construction Easy mounting Duct fixing kit included Product warranty and total quality commitment Our products carry a two-year warranty. Distech Controls is an ISO 9001 registered company. 1/5

Product Product Codes: -01 Bi-directional, 30, 50 & 100Pa 4-20mA multi-range air DP -02 0 to 30, 50 & 100Pa 4-20mA multi-range air DP -03 0 to 50, 100 & 300Pa 4-20mA multi-range air DP -04 0 to 100, 300 & 500Pa 4-20mA multi-range air DP -05 0 to 300, 500 & 1000Pa 4-20mA multi-range air DP -06 0 to 500, 1000 & 1600Pa 4-20mA multi-range air DP -07 0 to 1000, 1600 & 2500Pa 4-20mA multi-range air DP -08 0 to 1600, 2500 & 5000Pa 4-20mA multi-range air DP For option s add suffix to the partcode: -V For 0-10V voltage version -LCD Integral LCD option Accessories -CAL Calibration certificate A duct fixing kit is supplied with the PA-699, consisting of 2m of 6mm ID plastic tubing, 2 x pitot tubes and 4 x fixing screws. Installation 1. Mount the unit onto the duct or wall by drilling two holes at 80mm centres and fix with self-tapping pan head screws. 2. Push the pressure tubing onto the pressure ports on the unit. Ensure that the Hi and Lo ports have been correctly identified (P1 High, P2 Low). 3. Undo screw on hinged lid, pass cable through the cable gland PG11 and make connections as required. CAUTION The will be damaged if subjected to excessive pressure. Do NOT test the unit by blowing into the inlet ports. 2/5

Dipswitch Settings Factory settings Range 00 Range 01 Range 10 Range 10 Range 01 Range 00 30 to 30Pa 50 to 50Pa 100 to 100Pa 0 to 30Pa 0 to 50Pa 0 to 100Pa 0 to 50Pa 0 to 100Pa 0 to 300Pa 0 to 100Pa 0 to 300Pa 0 to 500Pa 0 to 300Pa 0 to 500Pa 0 to 1000Pa 0 to 500Pa 0 to 1000Pa 0 to 1600Pa 0 to 1600Pa 0 to 2500Pa 0 to 5000Pa Mounting The recommended installation position is vertical, with the pressure connections facing downwards (factory calibration). With the unit mounted horizontally, cover facing downward this will effect the signal by approximately 10Pa higher than the actual pressure. With the unit mounted horizontally, cover facing upward this will effect the signal by approximately 10Pa lower than the actual pressure. 3/5

Connections 4-20mA output: 0-10Vdc output: 4/5

Specification Accuracy, total of linearity, Hysteresis & repeatability & fs: -01 to 04 ±1.0 max. Others ±0.6 Thermal effect TC zero point TC sensitivity Typical % fs/10k -01 ±0.02 ±0.03-02 ±0.02 ±0.03-03 ±0.02 ±0.02-04 ±0.01 ±0.01 Others ±0.01 ±0.01 Rupture pressure 2 x Overload @ ambient temp. Power supply: Current output 11 to 33Vdc Voltage output 13.5 to 33Vdc or 24Vac ±15% Load impedence: Current < ohm Voltage >10K ohm Current consumption: Current 20mA Voltage <10mA Pressure connections Push fit for 6.2mm ID tube Electrical connections Screw terminals for 1.5mm² max. Housing construction: Housing Polycarbonate PC Diaphragm Silicone Sensor Al 2O 3 (96%) / glass Temperature: Medium 0 to 70 C Ambient 0 to 70 C Storage -10 to +70 C Dimensions 92 x 75 x 51mm Protection IP65 CE Conformity: EN 61000-6-2, EN 61000-6-3, EN 61326-1 CE Marked, EMC Country of origin Switzerland Specifications subject to change without notice. Distech Controls and the Distech Controls logo are trademarks of Distech Controls Inc. ; LONWORKS is a registered trademark of Echelon Corporation ; Niagara AX Framework is a registered trademark of Tridium, Inc. ; ARM Cortex is a registered trademark of ARM Limited ; BACnet is a registered trademark of ASHRAE ; BTL is a registered trademark of the BACnet Manufacturers Association; Windows, Visual Basic.Net are registered trademarks of Microsoft Corporation. EnOcean is a registered trademark of EnOcean GmbH. All other trademarks are property of their respective owner. 5/5