Powersafe Electrical Switch User Manual - Original Language Version

Similar documents
Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Trapped Key Interlocks

Operating Instructions

Series 8146/5-V37 and Series 8150/5-V37

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electric Rotary Actuator - On/Off or programmable control actuator

Plug and Socket Devices CES 63 A Series 8579

H45 LED - Direct and indirect pendant

Plug and Socket Devices SolConeX 16 A Series 8570

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Linear Luminaire with LED Series EXLUX 6402/2

Trapped Key Interlocks for. Switchgear. Applications Guide.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Accessories SUNNY REMOTE CONTROL

Compact pressure switch Flameproof enclosure Ex d Model PCA

Terminal Boxes Series 8146

SELECTION, APPLICATION AND MAINTENANCE

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

3/2-way Solenoid Valve, direct-acting, NC or NO

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Technical Data. Dimensions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Instruction Manual Differential Pressure Transmitter

HERZ-Thermal Actuators

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

SEISMIC VELOCITY TRANSDUCER T1-40

FIREDEX Conventional Fire Panels

F-Series Camera Mounting Accessories

Proportional pressure regulators VPPE

Joystick PVRES and PVREL. Technical Information

RAY-MAX Integrated Solar Power Strip

Operating Instructions

Cable Plug acc. to DIN EN , Form A

Technical Data. Dimensions

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

ST Series POWER SUPPLIES USER INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Advantium 2 Plus Alarm

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

Circuit Breakers. Next Generation of Protection Capabilities

Vario-Series Accessories

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Operating Instructions for Plastic Flow Meter. Model: KSK

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Explosion proof enclosures

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

FC18 Controller(Interlocking) Product Manual

Safety detection solutions

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Sample - No Commercial Use

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Technical Information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Owner s Manual & Safety Instructions

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Floodlight Range Installation Guide

FG MOISTURE MONITOR Installation & Operation Manual

Industrial Ringdown/Autodialer Telephone SCR Series

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Mini USB and USB 2.0-IP67 Connector System

Manual Motor Starter MS 116 up to 16 A Technical Data

How To Use A Ds340 (Dsp)

3/2- and 2/2-way cartridge valve type BVE

Operating Instructions Drill rig DRU160

Installation Guide. DEVIreg 530. Electronic Thermostat.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Digital inductive conductivity transmitter

THE ADVANTAGES ARE YOURS

LIEBERT VNSA Installation Sheet

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

7 Lighting Technology

Unified requirements for systems with voltages above 1 kv up to 15 kv

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Transcription:

The KS is a key driven electrical switch designed for machine control circuits. This type of isolator should be used for short term, off load isolation. The KS is manufactured from either brass or stainless steel making it ideal for use in normal and harsh corrosive environments where the lock is subject to heavy use. The unit is able to be mounted into an existing panel or for surface mounting within its own polycarbonate IP65 rated enclosure. KS20-FSS-P-C/O4 Operation The Castell KS Power Key Switch is used for machine isolation in order to protect the hazardous area from access while power is on. KS20 Power Electrical Switch, back on panel mount 1 Key is trapped, while 2 Turn and remove key to switch 3 power is on the power off Key is free, power is off 1. While the power is on and a machine is running, the key is trapped in the Powersafe Key Switch. 2. By turning and removing the key out of the switch, the power will be shut off. 3. The key now can be taken to open the door lock and gain acces to the machine area. The KS is available for different switching loads as KS20, KS32 or KS63 (20, 32 or 63 amps power isolation respectivly) (see order information on page 6 for more details). The KS comes with 4 contacts as standard with contacts arrangements as 2NO/2NC, 4NC, but auxiliary set of contacts are available on request. The KS is available as a back of panel mount version or as a front of panel mount with an enclosure (see order information on page 6 for more details). 1 of 6

Usage The KS is designed to be part of a safety system and is used to isolate the power releasing a key which is then used to gain access to a hazardous area via an access interlock such as the AI, AIE or Salus. The KS Key Switch is not designed for security purposes. No hazardous substances were used in the manufacture of this product. The product can be disposed of in standard waste. Installation Front of panel units should be mounted to a flat surface using 4 off suitable fixing screws. Offer up back box of enclosure in desired position and use mounting holes as a drilling template. Back of panel units should be mounted to a flat surface. A Ø36mm hole and two off Ø7mm holes should be drilled in the panel to accept the lock mounting. The lock face should be sealed to the panel for ingress protection. Cables should be connected to the switch (via the cable gland for front of panel) in accordance with the applicable wiring diagrams. Ensure that the unit is bonded for earth continuity (see drawing on page 4 for more installation details). IMPORTANT: The interlock should be mounted using anti-tamper fasteners to prevent unauthorised removal. The KS range of switches must be installed by a competent and qualified person who has read and understood these instructions. Please retain this document in your technical file. Maintenance Periodic visual checks should be carried out by the site manager / safety officer. Do not lubricate lock barrel with oil or grease, use CK Dry Powder Graphite if necessary. In case of defects beeing detected please contact your nearest Castell Support Department for further actions. Please see Contact section for contact details. 2 of 6

Technical Data Temperature rating Type of mounting Weight Material Enclosure Power isolation Motor Isolation (AC Values) Switch approvals MTTF Certification Ambient temperature of stages: open at 100% lu/lth - 55 C during 24 hours with peaks up to 60 C, enclosed at 100% lthe - 35 C during 24 hours with peaks up to 40 C Storage temperature: -40 C to 85 C (in case temperature below -5 C no shock load permissible) 1/4 or M6 KS20: Front of board mount = 0,8 kg / back on board mount = 0,6 kg KS32: Front of board mount = 0,8 kg / back of board mount = 1 kg KS63: 1,5 kg Brass/Stainless steel Polycarbonate IP65 20A, 32A, and 63A options available KS20: AC-23A 7.5kW or AC-3 5.5kW KS32: AC-23A 15kW or AC-3 11kW KS63: AC-23A 30kW or AC-3 18.5kW BS,UL,CSA & VDE Available on request Application A typical application of KS Powersafe Key Switch is machine guarding. It is usually used in combination with an Access Interlock such as the Salus for part body access or an Access Interlock with an exchange key for full body access control. The KS breaks the machine safety circuit, ensuring a machine is shut down when the key is turned and removed. The key can then be taken to the Salus Automatic Access Interlock to enable access to the machine. The machine cannot be restarted until the door is closed, the bolt is trapped in the Access Interlock and the key is removed and taken to the KS Key Switch. EC-Declaration KS20 Key Switch Salus Access Interlock We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential health and safety requirements applying to them. Empowered signatory: Mr T.C. Whelan Managing Director 3 of 6

Drawing Dimensions: in mm Note: For safe mounting, use security screws KS20, FOB (Front of board, enclosure) KS20, BOB (Back of board) 4 of 6

Wiring Diagram Note: For safe mounting, use security screws Key Free, Switch off Key Free, 2 NO/2NC 5 of 6

Order Information Product Type 1 2 3 4 5 6 Part Number KS - - - Example KS 20 - FS B - P - C/O 4 7 ABC 1 Isolation 20 amps (UL:20A/CSA:16A) 32 amps (UL&CSA:30A) 63 amps (UL&CSA:65A) 2 Lock portion type FS (1) / Q (1) 3 Material B = Brass / S = Stainless steel 4 Mounting P = Panel mount (back of board) F = Front of board mount, with enclosure 5 Contacts arrangement in normal position C/O = no/nc arrangement (contacts closed/opened) CC = nc arrangement (all contacts closed) 6 Contacts number 4 = standard contacts number 7 Lock portion symbol FS (1) up to 3 digits / Q (1) up to 6 digits (1) FS - Lock type Q - Lock type Up to 3 symbols Up to 6 symbols Accessories Special construction available upon enquiry Product Part number Flip Cap FLIP-S Contact Information Castell Safety International Ltd. The Castell Building 217 Kingsbury Road London, England NW9 9PQ Castell Safety International Ltd. Oskar-Jäger-Strasse 137 50825 Köln Germany Castell Interlocks Inc. Suite 800 150 N Michigan Avenue, Chicago, Illinois 60601 USA Castell Safety China Building 1, No. 123, Lane 1165, Jindu Road, Minhang District, Shanghai 201108, China. t: +44 (0) 20 8200 1200 f: +44 (0) 20 8905 9378 e: uksales@castell.com t: +49 (0) 221 1649 794 f: +49 (0) 221 1649 795 e: eusales@castell.com t: +1.312.360.1516 f: +1.312.268.5174 e: ussales@castell.com t: +86 21 61519023 f: +86 21 61519030 e: chinasales@castell.com 6 of 6