DISTRIBUTION GROUP WITH MOTORIZED MIXING VALVE

Similar documents
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

HEAT INTERFACE UNITS (Modular)

stainless steel pre-assembled manifolds

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

HERZ-Thermal Actuators

Butterfly Valves PN 6/10/16 for flanged connection

Overview of types. Technical data

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Technical catalogue convectors POLAND 2012

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

SunMaxx Solar Filling Station Operating Instructions

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

SOLAR HEATING SYSTEMS.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Installation, operation and maintenance manual TX 35A

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Cooling system components, removing and installing

VOYAGER 570G. 744A Sprayer Control

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Installation & User Instructions

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Overheating limit control

Description of functions

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Triac Printed Circuit Board Replacement

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Zenith Solar thermal 4.5m pump station Installation manual

STABITHERM INSTALLATION & SERVICE BOOKLET

Economy Combo Heat Press Manual Model No.: ECH-800

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Powers Controls TH 192 S Single Temperature Room Thermostat

Series description: Wilo-Yonos MAXO

Conlift1, Conlift2, Conlift2 ph+

Type overview. Technical data

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

2- and 3-port valves with flanged connections, PN 10

Cable Plug acc. to DIN EN , Form A

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

3/2-way Solenoid Valve, direct-acting, NC or NO

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Floor Heating Warehouse.co.uk

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Line-Mounted Valves L Series

LK Electric Boiler - 4,5

MP8000 Series Pneumatic Valve Actuators

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Technical data. Danfoss DHP-A

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Catalogue Wilo- Stratos PARA

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2003 ACCORD - Automatic Transmission Removal

Troubleshooting Guide for Jacks Down LED Lights

3/2- and 2/2-way cartridge valve type BVE

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

LUCCI AIRFUSION QUEST II CEILING FAN

Stainless Steel Single and Dual Circulation Kits

Single sub-base valve

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Series description: Wilo-Star-Z

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Quick Connect Boxes Inside Gloveboxes

V94 BULK TAPE DEGAUSSER

Series description: Wilo-Yonos MAXO-D

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

QLM and QLD Series Three-port Control Valves

INSTALLATION INSTRUCTIONS

COLOR VIDEO DOOR PHONE CDV-71BE/D

Data sheet ECC 12 and 22

Operators manual Basic water heater

CRN A-F-G-E-HQQE 3x400D 50 HZ

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Float and Thermostatic Traps Series H, C and X

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Globo P. Ball valves Pump ball valve made of gunmetal

Electric Rotary Actuator - On/Off or programmable control actuator

Assisted lift operated 2/2-way solenoid valves Type EV250B

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Automatic control equipment for HVAC systems

1 DESCRIPTION OF THE APPLIANCE

Transcription:

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Description This preassembled pump group is part of the Trolli Heating line. This distribution group allows the circulation of the thermal fluid, coming from the primary circuit. This group regulates the temperature of the thermal fluid through the work of a motorized mixing valve. The group with thermal regulation is appropriate for heating system in general with delivery temperature regulation based on room temperature or outside temperature (climate control). The group is composed of the pump, shut-off valves supply/return side, mixing valve to be motorized, supply/return side thermometer, check valve anti-recirculation, thermal insulation. Range of products Distribution group with mix valve kv 6 03G xxx xx x Distribution group with mix valve kv 10 05G xxx xx x Ditribution group with mix valve kv 6 revesible 07G xxx xx x Distribution group with mix valve kv 10 reversible 09G xxx xx x Upper connection G 1" F 025 Without fitting 00 Fittings with running connections 01 Grundfos pump UPSO 25-65 180 Grundfos pump lpha2 25-60 180 Wilo pump Yonos Para 25-6 180 Without pump C D L X on demand See fittings Technical details Max working temperature: 90 C Max working pressure: 10 bar Female connections: UNI EN 10226-1 Male connections: UNI ISO 228-1 Pump: Grundfos UPSO 25-65 180 Grundfos LPH2 25-60 180 Wilo Yonos Para 25-60 180 llowed fluids: water, mix water and glycol (max 30%) Thermometers measurement range: 0-120 C, 30-250 F, Materials Ball and check valve Body: brass UNI EN 12164 - CW617N Gasket: PTFE, Viton, EPDM Mixing valve to be motorized Body brass UNI EN 12165 CW617N Diverter: brass UNI EN 12164 CW614N Gasket: EPDM Pump Body: Cast iron Insulation shell Body: EPP o Density 60 kg/m 3, o Thermal conductivity 0,039W/mK(20 C) o Thermal conductivity 0,041W/mK(40 C) Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 1 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Dimensions Configurazione codice prodotto Distribution group with mixing valve to motorize G G1 L H Pump Weight No.Pcs Components 03G / 07G 05G / 09G 02500C G 1" F G 1"1/2 M 125 363 Grundfos UPSO 25-65 6,9 1 02500D G 1" F G 1"1/2 M 125 363 Grundfos lpha2 25-60 6,9 1 02500L G 1" F G 1"1/2 M 125 363 Wilo Yonos Para 25-6 6,9 1 02500X G 1" F G 1"1/2 M 125 363 Witrhout pump 4,28 1 L, H in mm Weight in Kg on demand / 1 Pump Grundfos UPSO 25/65-180 05 040 065 B Grundfos lpha2 25/60-180 09 040 060 B Wilo Yonos Para 25/6-180 07 040 060 B Without pump Pump Shut-off ball valve Mixing valve to motorize Check valve Thermometer 2 Shut off ball valve 38D 025 000 3 Shut off ball valve w ith check insert 37D 025 000 4 Themometer 11D 015 000 120 5 Mixing valve to motorize 41D 6 Extension w ith by-pass 40D 040 000 L 7 Insulation shell / 1 Pump Grundfos UPSO 25/65-180 05 040 065 B Grundfos lpha2 25/60-180 09 040 060 B Wilo Yonos Para 25/6-180 07 040 060 B Without pump Pump Shut-off ball valve Mixing valve to motorize Check valve Thermometer 2 Shut off ball valve 38D 025 000 3 Shut off ball valve with check insert 37D 025 000 4 Thermometer 11D 015 000 120 5 Mixing valve to motorize 41D 6 Extension 40D 040 002 7 Insulation shell 8 T-Joint w ith by-pass on return 45D 040 000 Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 2 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Installation The installation of every component must be made from qualified people because this system is used to carry the fluid at temperature and pressure that can be dangerous for people and things. Introduction The distribution group with mixing valve is composed of the parts in the picture: Front insulation shell (1); Back insulation shell (2); Pump protection (3); Delivery side (4) includes shut-off ball valve of secondary circuit, mixing valve to be motorized and thermometer; Return side (5), includes shut-off ball valve, check insert and thermometer; Wall installation (only for groups supplied with steel bracket). Note: check the distance of the pipes from the wall. See point 7. 1. Remove the pre-assembled group from the boxing packing; 2. Open the shell pulling the parts (1) e (2) from the upper ends indicated; 3. Remove the pump protection (3); The front (1) and back shells (2) help the thermal insulation and save energy. The pump protection (3) has been introduced for maintaining the thermal insulation and avoiding the overheating of electric actuator of the pump. In this way the risk of damage is reduced. The thermometer that is integrated in the handle of ball valve helps the temperature control of both side. The check insert that is integrated in the body of shut-off valve of return side is used to prevent parasitic flows when the pump is off. The mounting options of the group are: Wall installation Installation on collector 4. Remove side (4) and side (5); 5. Cut the 2 boxes on the back shell; 6. The bracket has to be used on a suited wall. The bracket is provided with holes and a slot to facilitate the positioning. Fasten the bracket on the wall with screws and dowels you find in packing; Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 3 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE 7. Insert the back shell (2) in the bracket (6). Insert the delivery (4) and return side (5) on the bracket slightly lifting the shell. In this way the distance between the centre of the pipes and wall surface is about 54 mm. 10. Open the shut-off valve in return side (7) 11. Do the wiring (See the section Wire positioning ) 12. Insert the pump protection (3) 8. Install the pipes of both sides of the group through the fittings supplied in the packing (for models with fittings) or through the appropriate connections (it s recommended fittings with plane gaskets). In case there is a pump installed in series to the group (e.g. pump of the boiler), it s a good practise to install a unit for hydraulic separation of the circuits to avoid malfunctioning of both pumps or boiler. 13. Join the 2 parts of the shell (1) Installation on collector 9. Rotate the handle of the shut-off valve (7) of return side up to 45. In this position the ball will pres s the check insert disconnecting it and allowing a better water and air-flow. This air has to be eliminated during the filling phase. Fill the system and check the presence of leakage of thermal fluid (water or mix water and glycol). The distribution group can be installed on collectors with integrated hydraulic separator, on standard collectors with not integrated hydraulic separator, on collectors connected to a storage. For an appropriate installation, the collector must have the distance of connections of at least 60 mm from the wall. Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 4 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE 1. Follow the steps 1, 2, 3, 4, of wall installation; 2. To facilitate the installation, start from the centre of the collector and go on with the outermost ; install the delivery (4) and return (5) on the distribution collector through the fittings supplied in the packing (for models with fittings) or through the appropriate ones (it s recommended fittings with plane gasket) 5. Proceed as in step (9) of wall installation. 6. Open the shut-off valve of return side 7. Do the wiring (see wires positioning section) 8. Join the 2 parts of the shell holding the part (2) on the back side Wires positioning 3. Put on the back shell (2); (if the collector is too close to the wall, it s necessary to insert the part (2) before installing the delivery (4) and return (5) The wires must be connected by qualified people to avoid any safety risks for people and things. The back shell (2) has been realized to help the wires positioning inside the shell. In fact there are guides that allow the reaching of the lateral wires of the shell (2). 4. Put on the front shell (3) pressing the part (2) from the back side; Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 5 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE djustment of the mixing valve The mixing valve allows the setting of temperature of delivery through the mixing of hot and cold thermal fluid. The regulation is obtained regulating manually the valve with the handle supplied or through the actuator (for groups supplied with actuator). 3. Switch on the pump 4. Loosen the screw (2) of by-pass. The mixing valve that is supplied inside the group has a by-pass system to be regulated. This by-pass is helpful for delivery temperature regulation when the mixing valve is motorized and controlled by a regulator. It s possible to regulate the delivery temperature when the valve has the return way totally close (highest demand from the consumer). In this way the temperature regulation from the controller, will cover a rotation of 90, avoiding instabilities of temperature, change of rotation of the actuator and dangerous peaks of temperature (e.g. floor heating system). TTENTION: in case of high difference of temperature between the boiler and the consumer it s possible not to achieve the consumer temperature, even if the by-pass is completely open. It s recommended to do the regulation in the best way possible. In order to do a precise temperature setting, it s important to switch on the heat generator at the delivery temperature following the project specifications and to bring system to scheme. In this way the adjustment of the valve will be maintained precise. 1. ssemble the handle (1) with the screw supplied with the group. 5. Regulate the screw (3) of by-pass to get the right temperature. Consider that by-pass in the picture on the left is totally close, the one in the centre is totally open. Close the screw (2) 6. In case the by-pass regulation is not enough, bring the handle (1) in the position for getting the temperature of the project. In this way if the handle was tampered, the by-pass would limit the delivery temperature. 7. Install the actuator (See the section ctuator Installation) 2. Rotate the handle (1) in the position indicated (arrow on nr 10). In this position there is no mix Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 6 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Installation of actuator The actuator for distribution group is supplied with the components you can see in the picture. ctuator (1), Graduated ring (2), Mixing adapter (3), ctuator stop (4), clamping screw (5). See the following steps for the intallation on the mixing valve. 1. Watch the graduated ring (2) for the percentage of hot water. Turn the ring as in the picture o the right. 5. Watch the mark on the adapter. 6. Turn the mark of the adapter (2) until getting number 10 on the mixing valve. 2. Insert the ring (2) inside the guide of the actuator (1) 7. Insert the actuator (1) as in the picture and close everything with the clamping screw. 3. Through a pressure and clockwise rotation, turn the handle until the end and stop it. 4. Insert the adaptor (3) and screw the actuator stop (4). In this way the handle of the actuator is positioned for achieving the maximum flow rate on delivery and no flow rate on return. 8. Connect the wires of the actuator to the right regulator for climate setting based on outside Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 7 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE temperature or for setting the delivery temperature based on room temperature. Installation and adjustment of differential by-pass valve (for models with differential by-pass or installation at a later time). 1. The installation of differential by-pass valve must be done in the position shown in the picture 2. For the installation of differential by-pass valve (specially with filled system) you must close the 2 ball valve with thermometer as shown in the picture. 4. Rotate the handle of the valve on the value specified from the designer in order to achieve the right working conditions for the system. Pump replacement The distribution groups has been realized in order to hold different type of pumps. The models that suit the distribution group Barberi are shown in the table. The pump Grundfos UPSO is supplied by Barberi without the cable; the pumps Grundfos lpha2 e Wilo Yonos Para are supplied with wire and connector following the dimensions of the shell of distribution group. In case of purchasing the pumps from other suppliers, pump and connector may require small adjustments on the shell, The installer can do the adjustment by himself. 3. Disassemble the lateral cover and the plane gaskets of the ball valves. Insert the differential bypass valve (8) (e.g. art 615, art 616) with plane gaskets supplied with the packing, paying attention to the flow direction indicated by the arrow. Suitable pumps with distribution group Grundfos UPSO 25/65-180 Grundfos lpha2 25/60-180 Wilo Yonos Para 25/6-180 Barberi. Other type of pumps have to be singly evaluated from the company Barberi. Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 8 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Positioning of the group The distribution unit with mixing valve can be installed in different ways from the standard (delivery on the right and up direction). The possible layout of positioning depends on the model of the pump installed. In the table below are shown the options you have with the pumps you are using. Scheme 1 Scheme 2 Scheme 3 Scheme 4 Pump rt.03g rt.07g rt.05g rt.09g rt.03g rt.07g rt.05g rt.09g rt.07g rt.9g rt.07g rt.09g Grundfos UPSO 25/65-180 ok ok ok ok Grundfos lpha2 25/60-180 ok ok ok ok Wilo Yonos Para 25/6-180 ok ok ok ok The distribution unit with mixing valve is supplied with standard layout as shown in the scheme 1-2, with pump on the right, delivery up direction or after rotation, pump on the left and lower direction. The articles 07G and 09G can be installed to get the scheme 3-4 follwing these steps: 1. Loosen the running fittings shown in the picture and pull the extension (2) paying attention to the plane gaskets ; 3. Insert the plane gasket and close the connections. 4. Rotate the actuator of the pump if necessary (if pump allows to rotate the actuator) 2. Reverse the mounting position of the pump (1) and the extension (2) ttention: keep the ball valve with red handle on the side with the pump, the one with blue handle on return side because of the presence of unidirectional check valve. Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 9 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Diagrams Pressure drop of distribution group with mixing valve PERDITE DI CRICO GRUPPO PRESSURE DI DISTRIBUZIONE DROP OF MIXING CON VLVE VLVOL DISTRIBUTION MISCELTRICE GROUP MOTORIZZBILE DP[m] 9,50 9,00 8,50 8,00 7,50 7,00 6,50 6,00 5,50 5,00 4,50 4,00 3,50 3,00 2,50 2,00 1,50 1,00 0,50 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 03G 07G 05G 09G Q[l/h] 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 Q[l/min] 95,0 90,0 85,0 80,0 75,0 70,0 65,0 60,0 55,0 50,0 45,0 40,0 35,0 30,0 25,0 20,0 15,0 10,0 5,0 0,0 DP[kPa] Head and power consumption of the pumps Head Prevalenza of Grundfos Circolatore pump Grundfos UPSO UPSO 25-65/180 Power Potenza of Circolatore Grundfos Grundfos pump UPSO 25-65/180 H [m] 7,00 6,00 7 6 H [kpa] P [W] 14 12 Pc3 5,00 4,00 3,00 Vc2 Vc3 5 4 3 10 8 6 Pc1 Pc2 2,00 1,00 Vc1 2 1 1,00 2,00 3,00 4,00 5,00 G[m3/h] 4 2 1,00 2,00 3,00 4,00 5,00 G[m3/h] Vci: Constant speed Pci: Power consumption Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 10 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Head Prevalenza of Grundfos Circolatore pump Grundfos LPH2 lpha2 25-60/180 Power Potenza of Grundfos Circolatore Grundfos pump LPH2 lpha2 25-60/180 H [m] 7,00 6,00 5,00 4,00 3,00 DPc2 DPc1 7 6 5 4 3 2,00 DPp2 2 DPp1 Vc2 1,00 Vc3 1 Vc1 0,50 1,00 1,50 2,00 2,50 3,00 3,50 G[m3/h] H [kpa] P [W] 5 45,00 4 35,00 3 25,00 2 15,00 1 PDPc2 PDPp2 PDPc1 PDPp1 PVc2 PVc3 5,00 PVc1 0,50 1,00 1,50 2,00 2,50 3,00 3,50 G[m3/h] Vci: DPpi: DPci: Constant speed Proportional pressure Constant pressure PVci: Power consumption at constant speed PDPpi: Power consumption at proportional pressure PDPci: Power consumption at constant pressure Head Prevalenza of Wilo Circolatore Yonos Para Wilo pump Yonos Para 25-6 25-6 180 180 Power Potenza of Circolatore Wilo Yonos Wilo Para Yonos pump Para 25-6180 180 H [m] 7,00 6,00 5,00 4,00 3,00 2,00 1,00 DPc5 DPp5 DPc4 DPp4 DPc3 DPp3 DPc2 DPc1 DPp2 DPp1 7 6 5 4 3 2 1 0,50 1,00 1,50 2,00 2,50 3,00 3,50 G[m3/h] H [kpa] P [W] 5 45,00 4 35,00 3 25,00 2 15,00 1 5,00 PDPp5 PDPc5 PDPp3 PDPc3 PDPp1 PDPc1 0,50 1,00 1,50 2,00 2,50 3,00 3,50 G[m3/h] DPpi: DPci: Proportional pressure Constant pressure PDPpi: Power consumption at proportional pressure PDPci: Power consumption at constant pressure Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 11 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Examples of installation Specifications The text refers to a specific code of the product. For each version of the group the designer must modify the specifications. Codice 03G02500C The distribution unit with mixing valve to motorize with 1 1/2 G male connections with plane gaskets on primary circuit and 1 G female on the secondary circuit. Distance between connections of delivery and return:125mm. Height of delivery and return side: 363mm. Dimensions of the group with shell: 247, 410, 212,(width, height, depth). The group is composed of : shut-off ball valves of secondary circuit in delivery and return, check valve on return side, KV6 mixing valve, delivery and return thermometer with scale 0-120 C. Fittings available for differential by-pass valve 615/616, pump with 3 constant speeds Grundfos UPS 25-65 180, power supply 230V (50Hz). Shell in EPP black colour 60 kg/m 3. Maximum temperature of the thermal fluid 90 C. Maxi mum working pressure of thermal fluid 10bar. Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 12 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE Components rt. 38D025000 Shut-off ball valve with integrated thermometer 0-120 C (30-250 F). Pump connection with running fitting 1 1/2 F. Plane gasket D45 x d33.3 x 2. \\ article dimensions handle 38D 025 000 G 1"1/2 x G 1" red rt. 37D025000 Shut-off ball valve with integrated thermometer 0-120 C (30-250 F) and check insert. Pump connection with running fitting 1 1/2 F. Plane gasket D45 x d33.3 x 2. article dimensions handle 37D 025 000 G 1"1/2 x G 1" blue rt. 40D040000L Extension with by-pass article dimensions 40D 040000L G 1"1/2 M x G 1"1/2 M x G 1" F rt. 11D015000120 Thermometer with double scale Measuring range : 0-120 C (30-250 F) rt. 41D Mixing valve to motorize with integrated by-pass. Pump connection with 1 1/2 F running fitting. Plastic handle supplied for maunual regulation. Plane gasket D45 x d33.3 x 2. Maximum pressuree: 10 bar article dimensions KV 41D 040000 C G 1"1/2 M x G 1"1/2 F x 1" M 6 m3/h 41D 040000 I G 1"1/2 M x G 1"1/2 F x 1" M 10 m3/h rt. M030101DB 3 speeds actuator for mixing valve speed 120s/90, run 90, torque 10[N], voltage 230V, frequency 50Hz.. Locking screw and antirotation pin article dimensions control M03 010 1D B 120 s (90 ) 3 point rt. 440015011I Kit with handle for manual regulation of the mixing valve rt. 39D020000R Shut-off ball valve. Pump connection with running fitting 1 1/2 F. Plane gasket D45 x d33.3 x 2. article dimensions handle 39D 020 000 R G 1"1/2 M x G 1"1/2 F red article dimensions 11D 015000120 D 52 mm Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 13 /14

DTSHEET DISTRIBUTION GROUP WITH MOTORIZED MIXING VLVE rt. 44D025000 Connections with plane gasket Maximm temperature: 90 C article dimensions 44D 025 000 G 1" x G 1"1/2 rt. 40D040002 Extension article dimensions 40D 040 000 2 G 1"1/2 x G 1"1/2 rt. 45D040000 T-joint with by-pass on return rt. 42D025Z00I Bracket for wall mounting of the group, including screws and dowels. article hole distance 42D 025 Z00I 90 mm rt. 05040065B Grundfos pump UPSO 25-65 with 3 constant speeds. article dimensions connection distance max head 05 040 065 B G 1"1/2 x G 1"1/2 180 mm 6,5 m rt. 09040060B article dimensions 45D 040 000 G 1"1/2 F x G 1"1/2 M x G 1"F rt. 615-616 Differential by-pass valve with plane gasket. Distance between connections 65mm. article dimensions regulation range 615015000 G 3/4" x G 3/4" 0,2-2,5 mh2o 616015000 G 3/4" x G 3/4" 2-6,5 mh2o Grundfos lpha 25-60 (with autoadapt) high efficiency pump (EEI < 0.23 in compliance with Directive EuP). Supplied with 2 m wire and connector that fits with the group Maximum temperature: 110 C article dimensions connection distance max head 09 040 060 B G 1"1/2 x G 1"1/2 180 mm 6 m rt. 07040060B Wilo Yonos Para high efficiency pump 25-6 (EEI < 0.23 in compliance with Directive EuP). Supplied with da 1 m wire. Maximum temperature: 95 C article dimensions connection distance max head 07 040 060 B G 1"1/2 x G 1"1/2 180 mm 6 m Barberi Rubinetterie Industriali s.r.l. - 13018 VLDUGGI(VC) ITLY - Via Monte Fenera, 7 - Tel.+39-016348 284 Fax +39-0163 48 287 - e-mail: barberi@barberi.it - Sito Internet: http://www.barberi.it 14 /14