Oil Mist Separator Unit LGA 600 F/FU

Similar documents
Backflush filter R8-30W

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

MEMBRANE VACUUM MINI PUMPS

Kompressoren. Adsorption Dryer AD

Technical Data. Dimensions

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Rittal TopTherm fan-and-filter unit

Adsorption air dryers ADS 1 215

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

Rotary screw compressors kw 5,5 7, , bar MODULO

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Machine Documentation BELKI Oil Separator type 301

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Vacuum drying oven for non-flammable solvents

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

6 Crankcase Ventilation

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Installation and instruction manual for Laing DDC pumps

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Under sill units. Type FSL-B-ZAS

Power consumption (kw)

Refrigeration Compressed Air Dryer Buran Ultrapulse

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Adjustable room thermostat for heating only or cooling only systems

SOLENOID VALVES AND PNEUMATIC VALVES

SHAKER CONVEYORS.

Fixed displacement vane pumps

UNITOR VACUUM cleaners

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

A/C refrigerant system, overview

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Hydraulic control unit series

2/2 and 3/2 Way Size 6 Seat Valves

swimming pool accessories

REMOVAL AND INSTALLATION

Surface Technology. Centrifugal Fan GMD

SC-32 CNC LATHE OPERATION MANUAL

ECOCIAT. Domestic hot water heat recovery unit

Cooking at the Speed of light!

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

Installation, operation and maintenance manual TX 35A

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

VDL 53 - Vacuum drying oven for flammable solvents

Material test chamber with mechanical convection

INFRARED QUARTZ WALL HEATER

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

Incubator with mechanical convection

ECO 80 PRODUCT DESCRIPTION FEATURES. Power output S1 100% Adjustable air nozzle. Liquid cooling. Minimalmengenschmierung MMS retrofit

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

AIR CONDITIONER INSTALLATION MANUAL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

HEATER, AIR CONDITIONING AND VENTILATION

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Basic Hydraulics and Pneumatics

OIL MIST SEPARATOR OENA-DM

ROTARY SCREW COMPRESSOR. RMD kw

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

compressed air conditioning accessories. one stop shop process reliable efficient economical high degree of reusability

3/2-way Solenoid Valve, direct-acting, NC or NO

Solenoid Valve Island Type 3965

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

Mechanical Seal Piping Plans


ONE STAGE LIGHT OIL AND KEROSENE BURNERS

Radial piston pumps type R and RG

Series 8146/5-V37 and Series 8150/5-V37

GenStore Archive Cabinet

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Product catalogue, pipe and sewer cleaning systems

Atlas Copco Stationary air compressors

ThermoStar Refrigeration Air Dryers

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

UDSA - UDSBD unit heater

Hydraulic Control Solutions

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Varian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ThermoSorb Desiccant Dryers

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Transcription:

Oil Mist Separator Unit LGA 600 F/FU Nominal volume flow 600 m³/h 1 Features High performance oil mist separator unit for separation of coolant from tooling machine exhaust air Compact design High oil mist load capacity Excellent retention rates Quality filters, easy to service Equipped with high-efficient coalescer elements Optimized service life Modular design for direct installation of main components into tooling machines Worldwide distribution

2 Fractional collection efficiency 3 Operating principle x = Particle size in µm y = Fractional retention rate in % Aerosol: Wiolan SH 10 Raw gas concentration: 50 mg/m³ Volume flow: 600 m³/h 1 = Filter cartridge as delivered 2 = Filter cartridge after 100 operating hours Oil aerosols are sucked away from the machining space of machine tools The oil-laden air flows outward through the coalescer element from the inside The oil attaches itself to the fibre media as it passes through the filter Minute oil droplets "coalesce" to form larger drops These larger droplets migrate downwards on the coalescer element due to gravity The oil accumulates at the bottom of the housing and is returned to the cooling lubricant storage reservoir via the oil drain hose and the membrane valve The vacuum in the filter housing causes external air to be sealed off by the membrane valve The valve opens automatically when the oil in the drain hose reaches a height of at least 500 mm The cleaned airflow is sucked away by means of a high-pressure fan and blown out at the top through a silencer 4 Application 5 Product information Suitable for non-water-miscible cooling lubricants (cutting oil, grinding oil, drilling oil) and oil aerosol exhausted by machine tools and also for water-miscible cooling lubricants Operating limits If oil is used as cooling lubricant for machining processes, air usually has to be sucked away from the working area to prevent the atomized oil from dispersing The concentrations that often occur in the cooling lubricant jet or in the machine room could result LGA 600 F The LGA 600 F is driven by a frequency controlled motor The motor runs at the maximum permissible speed At initial operation the volume flow achieves approx 1300 m³/h at low differential pressure This flow rate is reduced to around 600 m³/h within one or two days, depending on the raw gas concentration LGA 600 FU The LGA 600 FU is driven by a frequency controlled motor A volumetric flowrate sensor supplies the actual value required to in ignition in case of tool breakage, for example If the machining obtain a constant volume flow of 600 m³/h If this value falls below process involves flammable cooling lubricants or flammable mathe setpoint, an electrical signal is output at approximately 450 m³/ terials, safe operation must be ensured by providing suitable fire h These signals can be evaluated to enable suitable maintenance and explosion protection devices in conformance with statutory action to be taken regulations Installation in potentially explosive atmosphere (Zones 0, 1 and 2) is not permitted! 6 Order numbers Type Order number LGA 600 F 70353616 LGA 600 FU 70329105 LGA 600 F (special voltage) 70359300 LGA 600 FU (special voltage) On request 2

7 Modules/main components LGA 600 F 1 2 3 4 5 6 7 8 9 LGA 600 FU Membrane valve Oil hose Air inlet nozzle Oil drain nozzle Coalescer element Housing Filter housing Eyebolt for transport Fan 10 11 12 13 14 15 16 17 Electric motor Air outlet nozzle Silencer Connection port Control unit Frequency converter Volumetric flowrate sensor Mounting base plate 8 Technical data LGA 600 F/FU, 400 V/50-60 Hz (standard) LGA 600 F/FU, 200 V/50-60 Hz (special) Volume flow 600 m³/h 600 m³/h Temperature range + 10 C to + 60 C + 10 C to + 60 C Nozzles 150 mmm (2x Jacob) 150 mmm (2x Jacob) Oil hose PVC transparent 15x2 mm (3 m) PVC transparent 15x2 mm (3 m) Filter 1 coalescer element 1 coalescer element Filter surface 46 m² 46 m² Dimensions (LxWxH) 930x555x780 mm 930x555x780 mm Weight 140 kg 140 kg Supply voltage 3 AC 400 V/N/PE, 50-60 Hz 3 AC 200 V/N/PE, 50-60 Hz Current consumption 69/40 A 78/46 A Protection class IP 54 IP 54 Backup fuse 16 A 16 A Connection port Harting 10 B Harting 10 B Motor output 22 kw 22 kw Motor speed 6140 U/min 6140 U/min Sound level 72 db (A) 72 db (A) 3

9 Dimensions 4

10 Installation 11 Spare parts and accessories Order numbers for spare parts and accessories Designation Coalescer element 79354390 Membrane valve 78769697 Harting easy hood (19 30 010 1540) 70360184 Harting bush insert (09 33 010 2716) 1 2 3 4 5 6 7 Order number 70345233 Jacob hose nozzles 70346551 Jacob clamp ring 79389081 Jacob NBR flanged sealing ring 76141121 Jacob 90 pipe bend 70365712 Equipotential bonding Suction pipe Air inlet nozzle Oil hose Oil storage reservoir Membrane valve Exhaust air Note the minimum clearance of 480 mm is required for element removal! 5

MAHLE Industriefiltration GmbH Schleifbachweg 45 D-74613 Öhringen Phone +49 7941 67-0 Fax +49 7941 67-23429 industrialfiltration@mahlecom wwwmahlecom 7030226604/2015 6