Confocal Microscopy - principles and applications

Similar documents
Zeiss 780 Training Notes

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Chapter 12 Filters for FISH Imaging

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Recording the Instrument Response Function of a Multiphoton FLIM System

Applications of confocal fluorescence microscopy in biological sciences

ZEISS Microscopy Course Catalog

Webex-based remote instrument control guide

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Zeiss Axioimager M2 microscope for stereoscopic analysis.

Introduction to Confocal Laser Scanning Microscopy (LEICA)

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Introduction to flow cytometry

FRET Basics and Applications an EAMNET teaching module

Optical laser beam scanner lens relay system

Tandem Scanner. Leica TCS SP5 II: The Broadband Confocal High Speed and High Resolution All in One

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Synthetic Sensing: Proximity / Distance Sensors

Principles of Microscopy and Confocal and Fluorescence Microscopy

Theremino System Theremino Spectrometer Technology

A VERYbrief history of the confocal microscope 1950s

COMPENSATION MIT Flow Cytometry Core Facility

By: Christine Labno, Ph.D. Assistant Director, AB129 site Office: AB129 (Abbott Hall) Phone: x

Flow cytometry basics fluidics, optics, electronics...

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Confocal Fluorescence Microscopy

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Experiment 5. Lasers and laser mode structure

Leica TCS SP5 The Multi-User Confocal Microscope

Zecotek S Light Projection Network Marketing

Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.

Neuro imaging: looking with lasers in the brain

Fluorescence Microscopy for an NMR- Biosensor Project

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

Microscopy: Principles and Advances

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Fig.1. The DAWN spacecraft

A More Efficient Way to De-shelve 137 Ba +

Physics 441/2: Transmission Electron Microscope

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Near-field scanning optical microscopy (SNOM)

Computer Vision: Machine Vision Filters. Computer Vision. Optical Filters. 25 August 2014

Advances in scmos Camera Technology Benefit Bio Research

Fluorescent dyes for use with the

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

It has long been a goal to achieve higher spatial resolution in optical imaging and

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Principles of Flowcytometry

LASER SCANNING CONFOCAL MICROSCOPY

The Basics of Scanning Electron Microscopy

Realization of a UV fisheye hyperspectral camera

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Make Life Easier by Using Modern Features of the SPCM Software

Optical Coherence Tomography OCT. 3D Imaging in Medical Technology and Quality Control

Raman spectroscopy Lecture

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Introduction to Flow Cytometry

Review for Introduction to Remote Sensing: Science Concepts and Technology

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Study Guide for Exam on Light

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Basic 3D reconstruction in Imaris 7.6.1

Lecture 12: Cameras and Geometry. CAP 5415 Fall 2010

Measuring of optical output and attenuation

Infrared Viewers. Manual

A Guide to Acousto-Optic Modulators

DNA Detection. Chapter 13

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

How To Use An Edge 3.1 Scientific Cmmos Camera

MULTI PHOTON LASER SCANNING MICROSCOPE FV1000MPE FLUOVIEW NEW

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

True Confocal Scanner Leica TCS SP. User Manual

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

FTIR Instrumentation

Introduction to Flow Cytometry

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

These particles have something in common

3D Raman Imaging Nearfield-Raman TERS. Solutions for High-Resolution Confocal Raman Microscopy.

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

Diffraction of a Circular Aperture

Transcription:

Confocal Microscopy - principles and applications Dave Johnston / Anton Page Biomedical Imaging Unit Confocal Microscopy 1

focus - standard microscopy In standard microscopy, unless the specimen is very thin then areas of the specimen above and below the focal plane still contribute to the image as "out of focus blur" Confocal Microscopy 2

focus - confocal microscopy In confocal microscopy, a pinhole between specimen and detector is used to select information from a single focal plane, producing a sharply focussed optical slice through the specimen. Taking a series of optical slices from different focus levels in the specimen generates a 3D data set. Confocal Microscopy 3

laser scanning confocal microscopy a pair of oscillating mirrors raster scan a point of laser light across the specimen via the objective (epi-illumination). Fluorescence emitted by the specimen passes back through the mirror systems to a beam splitter which rejects any reflected excitation wavelengths and then through the pinhole to generate the optical slice. The detector (a photomultiplier tube) simply records the brightness of fluorescence at each raster point and maps this into a 2D (XY)image. Confocal Microscopy 4

Leica wavelength selective elements Spectral detection unit 3 Beam splitter 2 Laser Specimen Excitation selection module just as in conventional fluorescence microscopy, confocal microscopes need systems to: (1) select the excitation wavelength (2) discriminate between excitation and emission (3) restrict the wavelengths detected Confocal Microscopy 5 1

Leica confocal microscopes are not filter based Acousto-optical tunable filter (SP2 & SP5) Acousto-optical beam splitter (SP5) Spectral detectors (SP2 & SP5) Confocal Microscopy 6

acousto-optical tunable filter (AOTF) selects individual wavelengths from a multiwavelength output (argon) laser Principle: Laser Selection Specimen Confocal Microscopy 7

acousto optical beam splitter (AOBS) AOBS acts like a dichroic beam splittter to separate shorter wavelength / higher energy reflected excitation from longer wavelength fluorescent emission Confocal Microscopy 8

AOBS efficiency AOBS shows a very clean, sharp cut off between signal transmission and rejection compared to standard optical beamsplitters Confocal Microscopy 9

AOBS benefits Fast switching between channels Less bleed through with multiple labelling Higher signal transmission Less bleaching by optimising excitation intensity Easier region-of-interest scanning Confocal Microscopy 10

spectral detection can detect any emission wavelength in the visible and near infra-red no need to buy new filters when new dyes are introduced Confocal Microscopy 11

Leica spectral detector fluorescence is focused into a parallel "rainbow" light path a slit edged with mirrors can be moved across the light path and opened or closed to specify which wavelengths reach the detector behind the slit other wavelengths are deflected by the mirrors towards other detector /mirror / slit units detectors simply measure brightness within the specified spectral range on a 256 level grey scale false colour look up tables are used to map the intensity of each channel into arbitrary colours our Leica SP5 has 4 spectral detectors Confocal Microscopy 12

simultaneous acquisition RH tail of FITC fluorescence falls within spectral region being monitored for TRITC fluorescence, ditto (to a lesser extent) for RH tail of TRITC fluorescence in CY5 detection region Confocal Microscopy 13

sequential acquisition Confocal Microscopy 14 no TRITC region detection when FITC is being excited

sequential acquisition Confocal Microscopy 15 no FITC fluorescence when TRITC is being excited

sequential acquisition Confocal Microscopy 16 no TRITC fluorescence when CY5 is being excited

simultaneous or sequential acquisition? sequential acquistion: no crosstalk from Green to Red Channel simultaneous acquistion: crosstalk from Green to Red Channel Confocal Microscopy images: Colin Park, Leica 17

Leica SP5 LSCM inverted Leica DMI600 stand 9 laser lines (405 to 633 nm) 4 spectral detectors and transmitted light detector to >8000 pixel linear resolution objective range x5 to x100 with optical zoom DIC and phase contrast imaging environmental chamber and 5% CO2 in air supply resonant scanner electronic stage with relocation and tile scan function standard fluorescence microscopy with FITC / TRITC / DAPI compatible filter cubes 4 MP colour digital camera Confocal Microscopy 18

Leica SP2 LSCM upright Leica DM RBE stand 5 laser lines (405 to 633 nm) 4 spectral detectors and transmitted light detector to > 8000 pixel linear resolution objective range x5 to x100 with optical zoom, incl. x50 dipping lens DIC imaging galvo stage for fast XZ imaging standard fluorescence microscopy with FITC / TRITC compatible filter cubes Confocal Microscopy 19

confocal image types Confocal Microscopy 20

(1) animated Z stack playing back the Z series as a movie can show the relative positions of fluorescent signals but does not reveal the "whole picture" image shows collagen staining on skin basement membrane Confocal Microscopy 21

(2) maximum Projection creating a 2D image, pixel by pixel using the brightest value for that pixel in the Z series for each colour channel recreates the "whole picture" as a sharply focused image it is useful where structural elements span multiple Z planes as it allows them to be visualised as a whole - eg. neurons in a brain slice Confocal Microscopy 22

(2) maximum projection a disadvantage of maximum projection is the loss of spatial information in the Z plane in this image of bronchial epithelial cells, the maximum projection reveals that cilia (green) occur on a subset of cells and that a smaller and different subset are mucin (blue) producing goblet cells however, there is no way to tell that the cilia are at the luminal surface, the blue in the middle of the cell and the nuclei (red) are basal Confocal Microscopy 23

(3) rotated projection since the Z series is a 3D dataset, it is possible to calculate what it would look like if viewed from any other arbitrary angle it is therefore possible to create image series that show the sample rotating around any axis Confocal Microscopy 24

(4) Z section since the Z series is a 3D dataset, it is possible to calculate what it would look like if sliced across at any position image shows the topology of skin basement membrane revealed by collagen staining: on the left, a maximum projection (no topology evident): on the right, Z sections through the positions indicated by the faint white lines reveal a convoluted surface Confocal Microscopy 25

(5) 3D viewing rotating a single channel Z series to the left and right by about 8-10 degrees, and mapping one image to green, the other to red produces an image that can be viewed in 3D image shows willowherb pollen Confocal Microscopy 26

application types Confocal Microscopy 27

resonant scanning Standard scan mode: 512 x 512 pixel scan = 2-3 fps Resonant scan mode: true confocal scanning up to 1024 x 1024 pixels up to 5 channels 512 x 512 pixel scan = 25 fps 512 x 32 pixel scan = 250 fps 512 x 1 pixel scan = 16,000 fps useful for calcium imaging, muscle contraction and other rapid process imaging Confocal Microscopy 28 image: Leica Microsystems

FRET- fluorescence resonance energy transfer a method to study inter-molecular interactions at the 1-10nm scale by transfer of energy between flurochromes if donor and acceptor flurochromes are physically close enough, the energy emitted by the donor is not released as donor fluorescence but excites acceptor fluorescence Confocal Microscopy 29 images: Leica Microsystems and AAAS

FRAP fluorescence recovery after photobleaching a method to study the rate of diffusion of fluorescent molecules in fluid media (cytoplasm, membranes etc.) fluorescence in a specified region of interest is bleached by intense excitation and the rate at which fresh fluorescence diffuses back into the bleached region is determined Confocal Microscopy 30 images: Leica Microsystems, BBSRC Imaging Facility, Daresbury

reflectance mode Confocal Microscopy 31 images: TaiCaan Technologies