Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal



Similar documents
Automatic Back-Flushing Filter AutoFilt RF9.

Breathers and Filler Breathers.

Mobile Machines UPDATE Use HYDAC Expertise to avoid Air in Hydraulic Systems

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Components, Systems and Service for Municipal Machines.

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

DIESEL FUEL CONDITIONING

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

SEPAR FILTER SEPAR 2000 SEPAR 2000

Kompressoren. Adsorption Dryer AD

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Filter Elements E /05.06

Flushing and Cleaning the A/C System

Adsorption air dryers ADS 1 215

Particle Measurement Technology in Practice. From Theory to Application.

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Aerospace and Defence

CSD WATER REMOVAL FILTERS FOR DIESEL

Fixed displacement vane pumps

These pumps provide a well proven solution in many cases.

Hydraulic control unit series

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Trouble Shooting. Pump

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Automatic filters for fuel and lubricating oil. Technical information for oil filtration

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

Rotary screw compressors kw 5,5 7, , bar MODULO

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

REMOVAL AND INSTALLATION

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)

How To Make A Fuel Manager Filter/Separator

Refrigeration Compressed Air Dryer Buran Ultrapulse

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Advanced Filtration Media.

Longer lifetime for hydraulic oil

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Flex separation systems, S-separators

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Model 1210C Battery Powered Pump Shown. Description

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Hydraulic Control Solutions

Mechanical Seal Piping Plans

ETC -SV. Class 0 oil-free compressed air through catalysis

Duplex Filters 40 FLDK 0008(C)-0120(C)

MANTA Piston Distributor for Oil and Fluid Grease

Vertical Pumps for the Oil & Gas Industry

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Accumulators and Receivers

clean and quiet dental

Standard Hydraulic Piping Flushing Procedure

Basic Hydraulics and Pneumatics

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Oil and Coolant Circulating Heating System. Model - OCSM

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Screw Compressors 11-22kW

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Refrigeration Air Dryers. Catalogue

Kompressoren. Oil Water Separators OWS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Rickmeier Solutions. Gear pumps for superior Lubrication

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Overflow valve with thread connection

Guide #5 Cleaning a Fuel Tank

Hydraulic Trouble Shooting

Atlas Copco Quality Air Solutions. Compressed Air Filters

In-Line Filters and Coalescers with Automatic Drains

Refrigerated Air Dryers. Catalogue

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Diesel Fuel Additive Heavy Duty Applications. December 2011

Designed for multi-injector endurance testing, the

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

1 Fuel Filters and. Fuel/Water Separators

Membrane air dryers MS-LDM1, MS series

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Screw Compressors ESM Fixed Speed & VS Variable Speed

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

ST. VINCENT AND THE GRENADINES

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Bedienungsanleitung Diesel-Set 1 (Niederdruck)

6 Crankcase Ventilation

Installation and instruction manual for Laing DDC pumps

Shell Morlina S4 B. Advanced Bearing & Circulating Oils. Interim Technical Data Sheet. Previous Name: Shell Omala RL

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

AIRROLLAIR COMPRESSORS E

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Typical water pump claims and causes

compressed air conditioning accessories. one stop shop process reliable efficient economical high degree of reusability

Mechanical Seal Piping Plans

Unit 24: Applications of Pneumatics and Hydraulics

Improving Diesel Engine Life:

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

Transcription:

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + removal

Diesel PreCare: The Clear Link Guaranteed HYDAC quality thanks to HYDAC Quality Protection. TÜV certification Best cold start characteristics ensured by low pressure drop and cup filter design. Environmentally responsible through the use of incinerable elements. Outstanding water removal achieved by the two-stage system. 2

between Diesel Fuel and Diesel Power. High performance stability Efficient water removal over the entire service life. Element change = Complete overhaul The water removal stage built into the element is replaced when the element is changed. Extremely easy to maintain due to quick and simple element change. Flexible in use due to inlet/outlet options Ready-to-use at any time self-sufficient system, Plug & Play Return of surplus fuel to lubricate / cool the CR pump Pre-filter Main Filter Fuel tank H 2 O Automatic water discharge Charge pump Common Rail 7

Diesel PreCare: On the Recipe for success: Constant progress. Continuous product improvement is our driving force. It is through product innovation and efficient solutions that we meet the steadily growing demands of our customers as leaders in technology. With over 6,500 employees and over 500 sales and service partners we are in close contact with our customers all over the world. Innovative solution and sound design. Mobile machines and commercial vehicles are subject to the toughest working conditions all over the world. To ensure smooth running of vehicles and to protect both the engine and the whole drive system from damage, optimum diesel fuel conditioning is particularly important. With its new Diesel PreCare, HYDAC offers a modern system for diesel filtration which protects vehicle manufacturers and operators from failures, breakdowns and expensive service interventions. Our solution "HYDAC Diesel PreCare", is a cup filter system available in two versions: Manual water discharge (BestCost design) The conventional, operator-dependent solution. Fully automatic discharge Plug & Play (High Tech design) The innovative solution for fully automatic dewatering, independent of the operator, even when operated on the suction side. Innovative diesel filter. In black and white: Specifications Flow rate: BestCost design: up to 600 l/h HighTech design: up to 600 l/h Temperature range: BestCost design: -40 C to +90 C HighTech design: -20 C to +90 C Nominal voltage: 24 V DC (option 12 V) Rated power Fuel preheating: Filtration rating: 300 W Various (Standard: 10 µm) separation efficiency: > 95 % to ISO CD 16332 Operating pressure: BestCost design Inlet / Outlet: M22x1.5 (others on request) discharge: manual drain plug available in 2 sizes HDP BC 340 and HDP BC 600 Dimensions 282 mm (340 l/h), 342 mm (600 l/h) 170 mm < 1 bar (suction-side application) HighTech design Inlet / Outlet: G 3 /4 (others on request) discharge: Automatic discharge unit (including electronic control, safety valve, pump and water sensor) Dimensions 333 mm 161 mm 3 Outstanding performance data achieved by 2-stage water removal and superb filtration characteristics through the use of synthetic media these are the special features of these filters. Both systems are designed for use as pre-filters on the suction-side and as such protect all the pumps and components in the fuel system from water and contamination. 150 mm 162 mm

outside, compact, easy-to-service, robust. New element technology: Dieselmicron filter element with 2-stage system. Element construction Unique filter element design. The Diesel PreCare in the BestCost design has a filter element with a unique end cap design which is integral to its function. Particle removal and droplet coalescence (1st Stage) By using purely synthetic filter media, a high contamination retention capacity and steady coalescence is guaranteed. removal (2nd Stage) A hydrophobic barrier on the strainer tube guarantees reliable separation of the water droplets which coalesced during Stage 1. Dieselmicron filter element Stage 1: Particle filtration and droplet coalescence with filter mesh-pack Stage 2: removal via hydrophobic barrier on strainer tube Seals trap Function: The end cap has separate fluid pathways so that the cleaned fuel flows to the clean side (ring channel in the filter housing), while the separated water collects in the water trap. Increased operating reliability: achieved through strict separation of contaminated and clean sides. No risk of contamination at the fluid outlet of the housing during element change because the clean-side and inlet-side channels are vertically parallel to each other. Integrated Quality Protection: Highest level of reliability. Unless a HYDAC-original element is fitted in the housing, then the full function of the filter is not guaranteed because the element end cap which is integral to its function will be missing. We prevent inferior quality imitation elements from being fitted because our element end cap design is integral to the function, and has Quality Protection As a consequence, we can always guarantee our customers proven and first-class HYDAC Quality. Contaminated side Clean side Aluminium housing Ultimate system protection and guaranteed operating reliability achieved through guaranteed spare part quality. trap Heater 4 A new type of filter element in two-stage design which combines outstanding dewatering irrespective of the contamination level with excellent particle filtration at the same time. discharge Fuel water mixture

On the inside, innovative technology, high pr Screw-in cover plate Filtration stage Hydrophobic strainer Easy to service and environmentally sound. Easy to service since element change is in 3 simple steps: 1. Unscrew clogged element 2. Fit O-ring to new element and cover plate 3. Screw in new element We are helping to protect our environment by using fully incinerable filter elements (no metallic components). HYDAC Diesel PreCare Customer Benefits. Development on a scientific basis. In developing filter solutions to suit specific applications, HYDAC leaves nothing to chance. In addition to using the most up-to-date programs from CAD to FEM to make their designs, HYDAC invests heavily in the most modern research and test laboratories. Based on the results of scientific tests, efficient filters can be produced and tested systematically. Development of filter and element to suit the specific application. Tensiometers, Karl Fischer titration equipment, rinsing cabinets to determine component cleanliness, test rigs for multipass tests and water removal efficiency are in use on a daily basis. These are just some of our in-house capabilities for testing and improving our products in addition to numerous other test and measuring equipment. With filters which have passed through these test laboratories, you can be sure of success. General: Great flexibility with regard to installation position since inlet and outlet can be in either direction Consistent dewatering over the entire life of the filter element since water is removed on the clean side Robust design thanks to aluminium housing HYDAC laboratory and test rig to determine the efficiency of water removal. BestCost design: Low investment costs due to cost-optimized design Economical and technically reliable operation as a result of long element service life sensor and fuel preheating available as options Outlet Inlet HighTech design: Reliable dewatering thanks to automatic water discharge, even when operated on the suction-side Small installation space required, since lower section of filter does not have to be accessible Simple adaptation to the on-board power supply (Plug & Play) through the use of independently controlled water discharge Ultimate in weather protection Robust version for heavy duty, sustained construction site operation Oil analysis in the HYDAC laboratory at company headquarters. Fuel Just one example of the numerous filter testing procedures: Multipass test rig. 5

oduction standards, reliable performance. Unbeatable quality! Compared to the competition, HYDAC Diesel PreCare shows clear advantages with regard to water removal and filtration effect. Clean-side water removal using purely synthetic filter media combined with the hydrophobic barrier, has proved itself under the toughest conditions. Filtration efficiency % Competitor Brand 1 HYDAC Diesel PreCare Product benefits. Low residues of diesel left in the filter element when servicing Compact design Reliable radial seal Captive seal design Visual analysis of the contamination possible (Rust, metallic swarf, unusual deposits, which require further investigation) Protection from imitations by means of Quality Protection No first-line contamination with hard particles No ingress of contamination due to corrosion Reliable machine availability. Resulting from first-class contamination retention Test time (mins) Competition: Massive water penetration after a test time of just 180 minutes. HYDAC Diesel PreCare: Clean-side water removal using purely synthetic filter media combined with hydrophobic barrier has proved itself in comparison to the competition, and after a very long test time (730 minutes). Due to highly effective and stable water removal on the clean-side for the entire life of the filter element Life-long efficiency, because at element change, the water removal stage is always replaced Due to the excellent water removal, (achieved by using first class materials) of >95 % to ISO/CD 16332 TÜV certified filtration system. Both versions of the HYDAC Diesel PreCare Filtration System are certified by TÜV. HYDAC Filtertechnik GmbH Fuel filter, 340 l/h Fuel filter, 600 l/h Filtered using conventional Filter 1 Filtered using HYDAC Diesel PreCare Filtered using conventional Filter 2 Test of fuel / water separation efficiency according ISO CD 16332 (edition of 15.05.2009) and filtration efficiency using particle counting and contaminant retention capacity according to ISO 19438:2003, conducted on 340 / 600 l/h filter element After testing the effects of the filtration system installed in motor vehicles with diesel engines HYDAC has been issued with a clearance certificate by TÜV Süd relating to the installation of the filter. For further information please contact Technical Sales, HYDAC Filtertechnik GmbH. Telephone: +49 6897-509-1438, E-Mail: fuel@hydac.com A comparison of three diesel samples after filtration provides the proof. Even with the naked eye the exceptional cleanliness of the diesel filtered with the HYDAC Diesel PreCare is obvious. 6

Cooling Systems DEF 5.700 Electronics E 180.000 Accessories E 61.000 Compact Hydraulics E 53.000 Filter Systems E 79.000 Process Technology E 77.000 Filter Technology E 70.000 Accumulators E 30.000 Global Presence. Local Expertise. www.hydac.com HYDAC Headquarters HYDAC Companies HYDAC Distributors and Service Partners HYDAC FILTERTECHNIK GMBH Industriegebiet 66280 Sulzbach/Saar Germany Tel.: +49 6897 509-1438 Fax: +49 6897 509-9924 E-Mail: fuel@hydac.com www.hydac.com