OPUS C DC Power Systems Controllers

Similar documents
SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Infinity C DC to DC Power System

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

MAJORSINE Power Inverter

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

NIC Controller & Web Interface

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HWg-STE HWg-STE PoE MANUAL

Temperature & Humidity SMS Alert Controller

Indoor / Outdoor Antenna

Network Management Card. User Manual

Disturbance Recoder SPCR 8C27. Product Guide

sat-nms SMU Signal Management Unit

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Connectivity. PowerShield 3. Communications Software

Chassis, Power Supply, and Element Management

Software and accessories

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Uninterruptible Power Supply

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

T200, PTP/IEEE 1588 Grandmaster Clock and

PN5212/PN5320/PN7212/PN7320

NC-12 Modbus Application

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

MPR-Systems. Mini Power Racks 1200 W W

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Remote Monitoring and REC 501 Control Unit Product Guide

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

LAP ENERGIA PARA DATACENTERS

PLC training panel (Twido version)

Data Loggers for Real Time Temperature Monitoring - WiFi

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Square D Model 6 Motor Control Centers

Product Guide CM-Relay

Back-UPS Pro 1300/1500 Installation and Operation

PowerGem Pro Uninterruptible Power Supply

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Current Monitoring Kit QUICK START GUIDE

Energy Communication Unit (ECU)

Energy Communication Unit (ECU)

Thyristor-controlled power supplies and battery chargers

Current Monitoring Kit

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

MIDNITE SOLAR AND SOLAR WASHINGTON

Executive Summary. Technical Description

Overview of the Cisco 2500 Series Access Server

Overview of Cisco 2600 Series Routers

securityprobe5es -X20

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Infinity C DC to DC Power System

SMS GSM Alarm Messenger

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

VALIANT COMMUNICATIONS

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Poseidon MANUAL

GB USER S MANUAL GB 41

3500/93 System Display

Technical Overview CM-2 Climate Monitor. Get yours direct at:

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Workshop 7 PC Software - Tracker

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PSBC12XX-X Charger Management Software User Guide

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control.

User s Manual Network Management Card

ORION TELECOM NETWORKS INC. T1

Duct Humidity Transmitter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Installation and Operation Back-UPS 1250, 1300, 1500

INVERTER SYSTEM PRODUCT BROCHURE

DSX Master Communications

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

HP Port Switches Quick Setup Guide

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

MLC TM Maximum Productivity and Versatility for Control without Compromise!

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

TK800-Series Industrial GPRS / UMTS / LTE Router

DU-H3ETX. 3-port USB Hub with 1 NWAY Ethernet / Fast Ethernet Port. User s Guide

ABB central inverters PVS to 1000 kw

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

PRODUCT LIST Facility DDC Access WebXL DDC

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

M-series Virtual I/O Module 2

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Phase Modular Finally the benefits of Modular ups are for all

Transcription:

OPUS C OPUS C DC Power Systems Controllers VIDI+ System Controller VIDI+ I/O System Controller VIDI-LVD Low Voltage Disconnector VIDI-BM Battery Monitoring VIDI-SAM Serial Adapter Module Product Description VIDI Controller Platform is for OPUS DC Power Systems. It provides intelligent and easy user interface and comprehensive set of features for DC Power System management. VIDI architecture is based on PowerCAN bus communication and a modular design, which enables excellent system expandability, selectable additional features and flexibility in the design. Features Universal controller for all 24 VDC to 220 VDC OPUS DC Power Systems Modular structure for optimal performance and design flexibility Sophisticated User Interface. User friendly local and remote operation Comprehensive features and alarms Numerous user configurable alarms and settings Full remote monitoring and control with WEB interface via RS232, modem or TCP/IP SNMP v3 TRAP, GET, SET Large event log file with real time clock time stamps 2014_11_10_VIDI+ vd.0 draft.pdf, 2009. Efore reserves rights for changes. 1/5 File: DOC056706 D.00.pdf

Technical Specifications, Advanced Controller Modules Ports LAN Serial communication Monitoring and Control Local Monitoring and Control Local Display Local Operation Local LED indication Info Default view Languages Monitoring and Control Remote Monitoring and Control Remote PC connection Local PC connection Remote user interface Remote terminal Supported Protocols Languages 10/100 Ethernet, RJ-45 connector RS-232, 9600-115200 kbps User Interface Module 128 x 64 Graphical LCD with Backlight Dial button, Info button and cancel button 3 color system Status LED Dedicated button to open info text Charge mode, system voltage, number of active alarms English, Russian, Finnish, Custom Connect via LAN Connect directly with serial port RS-232 or LAN port E-mail or SNMP traps Web interface, 4 access levels Text mode interface over Telnet/SSH HTTP, HTTPS, Telnet, SSH, SMTP, SNMPv2, SNMPv3 NTP, DHCP, Modbus TCP/IP English, Russian, Finnish System Features System Output Voltage Measurement AC input voltage, individual rectifiers DC output voltage, individual rectifiers Measurements DC output current, individual rectifiers Temperature, individual rectifiers DC output current, total rectifiers Battery current Load current PowerCAN-Bus interface to MRC rectifiers and Smart Peripheral Modules Energy Save Mode, with MRC rectifiers Rectifier runtime counter Functions Alarm configuration System parameters upload and download in XML format Real Time Clock with Battery Backup Plug-and-Play Support, Automatic Module Configuration Inventory Management for Installed Modules Site Information text input Connections Battery or load LVD 1 pcs Contactor Coil Driver, Aux contact Connections VIDI+ VIDI+ I/O Alarm/Temperature Inputs 4 12 Alarm Relay Outputs 4 12 Earth fault detection 0 1 Modules Supported max number of all modules 48, 2009. Efore reserves rights for changes. 2/5 File: DOC056706 D.00.pdf

Limitations per module types Local User Interface panel 1 Rectifiers, supported max amount 47 VIDI-LVD Low voltage disconnection modules. Supported max amount. 8 VIDI-BM Battery management modules. Supported max amount. 16 VIDI-SAM modules. Supported max amount. 1 Battery Management features Measurements Battery tests Charge modes Functions Manual battery test Periodic battery test Natural battery tests, starts on mains fault Float charge Manual boost charge Periodic boost charge Automatic boost charge Temperature compensation in all charge modes Charge current limiting Discharged Ah-counter Time window for battery tests Configurable Configurable Log data Mains Fault Phase Fault Rectifier Low/Over voltage System Low/Over voltage Rectifier overcurrent Rectifier Over Temperature System Over Temperature High Battery Temperature Low Battery Temperature Rectifier Fault Module Error/Module Fault Load fuse fault Battery LVD or Load LVD Contactor failure Battery Temperature Sensor Fault Rectifiers No Redundancy /Rectifiers Over Load, Configurable limits Load Disconnect Warning, Configurable limits Load Disconnect Battery Fuse Fault Battery Discharge Test Fault Boost Charge Fault Battery Disconnect Warning, Configurable limit VIDI+ I/O Earth fault detection Alarm log: 512 last alarms, Event log: 100 last events, Battery Temperature Log Graph, System Power log, 12 Months Connectors Alarm/Temperature input Internal PowerCAN-Bus connector Screw terminals User interface Module RJ11, 2009. Efore reserves rights for changes. 3/5 File: DOC056706 D.00.pdf

PowerCAN Termination Plug Other PowerCAN connectors RJ45 RJ45 Plug Technical Specifications VIDI-LVD Low Voltage Disconnect Module Coil Contact Driver Coil Driver output voltage Aux contact for contactor Status indication VIDI-LVD Maximum allowed continuous coil current: 2A System voltage Indication of the actual core position of the latched contactor 1 pc shunt voltage measurement, 60 mv LED Green/Red Technical Specifications VIDI-BM Battery Monitoring Module Block Voltage Measurement Status indication VIDI-BM Inputs: 4 pcs 12V nominal, Accuracy < 20mV, polarity protection 1 pc shunt voltage measurement, 60 mv LED Green/Red Technical Specifications VIDI-SAM Serial Adapter Module Auxiliary communications Technical Specifications, common VIDI-SAM RS-232, RS-485, CAN 1 pc shunt voltage measurement Environmental VIDI+, VIDI+ I/O, VIDI-LVD, VIDI-BM, VIDI-SAM Cooling Natural convection Acoustic noise < 40 db Operating temperature -20 / +50 C Storage temperature -40 / +70 C Humidity 95 % (relative humidity, non-condensing) Altitude (max) 2000 m above sea level, 2009. Efore reserves rights for changes. 4/5 File: DOC056706 D.00.pdf

Applicable Standards EMC Safety Emissions: EN/IEC 61000-6-4 Immunity: EN/IEC61000-6-2 Harmonic currents: EN / IEC 61000-3-2 Voltage fluctuations & flicker: EN / IEC 61000-3-3 * Measured as a part of Opus C-series rack system IEC / EN 60950-1 * Tested as a part of Opus C-series rack system Order Information System controller kits Description VIDI+ controller kit. Includes system controller module and cable set VIDI+ I/O controller kit. Includes system controller module and cable set Auxiliary controller kits Description VIDI BM kit. Includes Battery monitoring module and cable set VIDI LVD kit. Includes Low Voltage Disconnector controller module and cable set. VIDI SAM kit. Includes serial adapter module and cable set. Used with OPUS EIM and DUAL inverters. Order number 8320X0004311 8320X0004312 Order number 9040X0002338 8320X0003275 8320X0004402, 2009. Efore reserves rights for changes. 5/5 File: DOC056706 D.00.pdf