Low Voltage Consumer Units & Distribution Boards
Consumer Units & Distribution Boards Contents General 2/3 Consumer Units Comby Housemaster compact 5/ Distribution Boards Protecta compact Protecta compact accessories Protecta compact pan assemblies Mini Center compact Mounting kits for compact 9 0/ Spare parts and general accessories Dimensional details 2 3/ SKC05C05
Consumer Units & Distribution Boards General The ABB range of sheet steel consumer units and distribution boards are designed for safety, reliability and availability in the electrical building installation. Complying to IEC 39-3, BS EN 039-3 Features All ABB consumer units incorporate unique design features making installation, modification an easy operation and less time consuming. Type Test Certification Quick & Easy 2 3 Removal or change of gland plates and fiing of top / bottom etention boes is quick & easy Easy handling for the user, all screws Pozidrive 2. Reversible door Quick and easy door change from left hand hinge to right hand hinging Eternal earth stud 2 SKC05C05
Consumer Units & Distribution Boards General Quick & easy electrical solutions for various installations. Connection options The TP&N distribution boards accept a variety of incoming devices, isolator, miniature circuit breaker, residual current device, MCCB or direct cable connection. The incoming devices are connected to the busbar via various connection kits. Front facia plate provides neat & attractive cover for all incomer options Robust spring loaded door catch with key lock Terminals Large 25 mm 2 earth and neutral terminals delivered in the open position. 3 SKC05C05
SKC 05 00 F000 Consumer Units Comby Comby Range Application Comby consumer units are designed to suit installations in domestic and commercial installations, easy to install, attractive and highly reliable. Fitted with either sheet steel flap or clear plastic flap for visual inspection of components. Complete with neutral and earth terminals and din rail. Technical Data Standard : IEC 39-&3, BS 039-&3 Ma. load : 00 amps Ma. voltage : 230 V ac, 50 Hz Range :,0, and modules Degree of protection : IP 30 Enclosure material : Cold rolled sheet steel Bo and cover mm (Aluzinc steel on request) Enclosure finish : Gray, RAL 035 Plastic flap For surface mounting rows modules 0 H W D mm 9 23 3 0 ECT 0 S ECT S ECT S ECT S SKB 0 32 C000 SKB 32 C000 SKB 32 C000 SKB 32 C000 2.2 2. 3.2. For flush mounting rows modules 0 H W D mm 2 2 2 2 229 23 3 0 ECT 0 F ECT F ECT F ECT F SKB 0 932 C000 SKB 932 C000 SKB 932 C000 SKB 932 C000 2.3 2. 3.5.3 SKC 05 002 F000 Steel flap For surface mounting rows modules 0 H W D mm 9 23 3 0 ECS 0 DS ECS DS ECS DS ECS DS SKB 0 32 C0002 SKB 32 C0002 SKB 32 C0002 SKB 32 C0002 2. 3... SKC 05 009 F000 For flush mounting rows modules 0 H W D mm 2 2 2 2 229 23 3 0 ECS 0 DF ECS DF ECS DF ECS DF SKB 0 932 C0002 SKB 932 C0002 SKB 932 C0002 SKB 932 C0002 2.9 3.. 5.0 SKC05C05
SKC 05 003 F000 Consumer Units Housemaster compact Application Housemaster consumer units are designed to suit installations in residential commercial and industrial installations, easy to install and highly reliable. Fitted with sheet steel flap for visual inspection of components. Complete with neutral and earth terminals. Unit comes complete with incoming devices. Surface mounting only, (flush on request). Technical Data Standard : IEC 39-&3, BS 039-&3 Ma. load : 00 amps 0 amps for way RCCB Ma. voltage : 230 V ac, 50 Hz Range :,,, and SP & N Split load,, 2, Degree of protection : IP 30 Enclosure material : Cold rolled sheet steel Bo and cover mm (Aluzinc steel on request) Enclosure finish : Gray, RAL 035 Housemaster sheet steel range Isolator (E2/00A) Incomer H W D mm 55 20 22 3 0 HSMS 0C HSMS 0C HSMS C HSMS C HSMS C SKB 0 2 C SKB 09 2 C SKB 3 2 C SKB 2 C SKB 22 2 C 2. 3. 3.. 5. SKC 05 00 F000 RCCB (F2AC/00/0.03A) Incomer, for HSRC 0C (F2AC/0/0.03A) Ma. load A 0 00 00 00 00 H W D mm 55 20 22 3 0 HSRC 0C HSRC 0C HSRC C HSRC C HSRC C SKB 0 2 C00 SKB 09 2 C00 SKB 3 2 C00 SKB 2 C00 SKB 22 2 C00 2.5 3.2 3.. 5.2 Split load (E2/00A+F2AC/0/0.03A) Incomer + + + H W D mm 22 3 0 HSSL +C HSSL +C HSSL +C SKB 3 2 C00 SKB 2 C00 SKB 22 2 C00. 5. 5.5 Accessories Single pole pin type comb busbar Ma. current A C.S.A mm 00 30 5 modules 2 2 0 0 Used for ** General as spare part (Original part) ECS 0C HSMS/RC 0C ECS 0C HSMS/RC 0C ECS C HSMS/RC 0C ECS C HSMS/RC 0C ECS C HSMS/RC 0C HSSL +C HSSL +C HSSL +C ** PNCB-05 SKB 03 02 P0005 PNCB-0 PNCB-2 PNCB- PNCB-2 PNCB-0 PNCB- PNCB- PNCB-0 SKB 03 02 P000 SKB 03 02 P002 SKB 03 02 P00 SKB 03 02 P002 SKB 03 02 P000 SKB 03 02 P00 SKB 03 02 P00 SKB 03 02 P000 0.022 0.035 0.052 0.0 0.09 0.03 0.05 0.02 0.20 5 SKC05C05
Consumer Units Housemaster compact (continued) Application Housemaster consumer units are designed to suit installations in residential commercial and industrial installations, easy to install and highly reliable. Unit comes complete with blanking plates, busbar, busbar cover, terminal bars and installation instructions. Surface mounting only. Technical Data Standard : IEC 39- & BS 039- Ma. load : 00 amps 0 amps for way RCCB Ma. voltage : 230 V ac, 50 Hz Range :,, 0, and SP & N Split load,, 2, Degree of protection : IP 30 Enclosure material : Moulded plastic Enclosure finish : White, RAL 900 Housemaster plastic range SKC 05 005 F000 Isolator (E2/00A) Incomer 0 H W D mm 22 22 22 22 22 90 230 300 30 0 23 23 23 23 23 HMMS 0C HMMS 0C HMMS 0C HMMS C HMMS C SPE 00 2 F0 SPE 00 2 F02 SPE 00 2 F03 SPE 00 2 F0 SPE 00 2 F05 2. 3. 3.. 5. SKC 05 00 F000 RCCB (F2AC/00/0.03A) Incomer, for HSRC 0C (F2AC/0/0.03A) 0 Ma. load A 0 00 00 00 00 H W D mm 22 22 22 22 22 90 230 300 30 0 23 23 23 23 23 HMRC 0C HMRC 0C HMRC 0C HMRC C HMRC C SPE 00 2 F02 SPE 00 2 F022 SPE 00 2 F032 SPE 00 2 F02 SPE 00 2 F052 2.5 3.2 3.. 5.2 Split load (E2/00A+F2AC/0/0.03A) Incomer + + + H W D mm 22 22 22 300 30 0 23 23 23 HMSL +C HMSL +C HMSL +C SPE 00 2 F033 SPE 00 2 F03 SPE 00 2 F053. 5. 5.5 SKC 05 00 F000 SKC05C05
Distribution Boards Protecta compact SKC 05 00 F000 Application Protecta compact distribution boards, a design aimed for safety, reliability and availability in the electrical building installation. Available in busbar and multi row types. Surface mounting only, (flush on request). Supplied without incoming device or outgoing protection device. Single row type are delivered complete with neutral and earth terminals, comb busbar and busbar neutral connection. Technical Data Standard : IEC 39-3 & BS 039 part & 3 Single row type Range :, 9, 3, and 22 Modules Multi row type Ma. load : 00 amps Ma. voltage : 230 / V ac, 50 / 0 Hz Range :, 32,, and 0 modules, 2, 3, and 5 rows Busbar type Ma. load : 250 amps Ma. voltage : 230 / V ac, 50 / 0 Hz Range :,,, 2,, and 2 TP&N 2,, 2, 3,, 0 and 2 SP&N Degree of protection : IP, pan assemblies IP Enclosure material : Cold rolled sheet steel Bo and cover mm (Aluzinc steel on request) Enclosure finish : Gray, RAL 035 Fault level : 35 ka SKC 05 009 F000 Single row type a distribution boards modules 9 3 22 H W D mm 55 20 22 3 0 ECS 0C ECS 0C ECS C ECS C ECS C SKB 0 2 C0 SKB 09 2 C0 SKB 3 2 C0 SKB 2 C0 SKB 22 2 C0 2. 2. 3... SKC 05 00 F000 Multi row type a distribution boards (distance between rows 50mm) rows 2 3 5 modules 32 0 H W D mm 20 502 50 00 00 EPA 0 EPA 02 EPA 03 EPA 0 EPA 05 SKP 2 C000 SKP 232 2 C000 SKP 3 2 C000 SKP 2 C000 SKP 50 2 C000 0. 3 2 SKC 05 0 F000 TP + N busbar type distribution boards TP 2 2 H W D mm 502 50 0 30 00 0 EPB25-30C EPB25-30C EPB25-30C EPB25-32C EPB25-3C EPB25-3C EPB25-32C SKP 0 2 C005 SKP 0 2 C005 SKP 0 2 C005 SKP 2 2 C005 SKP 2 C005 SKP 2 C005 SKP 2 2 C005 2 3.2.2.3.2 2.3 2. SKC 05 02 F000 TP + N busbar distribution boards with DIN rail for modules (MX version)* TP 2 H W D mm 502 50 0 EPB 30 MXC EPB 30 MXC EPB 30 MXC EPB 32 MXC SKP 0 2 C00 SKP 0 2 C00 SKP 0 2 C00 SKP 2 2 C00 * Connection kit EPB KITC is proposed for connection of incoming devices to the main busbars.. 3 SKC05C05
Distribution Boards Protecta compact accessories / TP + N pan assemblies SKC 05 03 F000 Accessories for distribution boards No. Accessory type 2 3 Flange plate blank Flange plate with knock-outs Cylinder lock with keys EPB GP EPB GP2 EPB CL A-G SKA 30 002 C000 SKA 3 002 C000 SKA 32 002 C00 0.3 0.3 0.2 SKC 05 0 F000 Side etension boes (distance between rows 50mm) modules rows 32 32 0 2 2 3 5 Sided with TP+N DB s way way way 2 way way way H W D mm 502 50 0 30 00 EPB SEB2R0W EPB SEB2R0W EPB SEB3R0W EPB SEBR2W EPB SEBRW EPB SEB5RW SKA 02 2 C000 SKA 2 2 C000 SKA 03 2 C000 SKA 0 2 C000 SKA 2 C000 SKA 05 2 C000 2.5 3.5 5.5 23 SKC 05 05 F000 Top etension boes ( Modules) Type H W D mm Sheet steel flap / Row Sheet steel flap / 2Row Plastic flap 0 0 EPB TEB 0S EPB TEB S EPB TEB 0P SKA 22 2 C000 SKA 2 2 C000 SKA 2 C000 3.5 SKC 05 0 F000 Top / bottom etension boes Type Plain cover Plain cover H W D mm 0 EPB TEB 0C EPB TEB C SKA 2 2 C000 SKA 23 2 C000 3.5 SKC 05 0 F000 TP + N pan assemblies TP + N pan assemblies, complete with busbars + earth / neutral bars. (range 0 A) 2 2 H W D mm 35 29 3 59 99 0 20 20 20 20 20 20 20 0 0 0 0 0 0 0 EPB 30 PAC- EPB 30 PAC- EPB 30 PAC- EPB 32 PAC- EPB 3 PAC- EPB 3 PAC- EPB 32 PAC- SKP 0 00 C00 SKP 0 00 C00 SKP 0 00 C00 SKP 2 00 C00 SKP 00 C00 SKP 00 C00 SKP 2 00 C00 3. 3..3 5.2..2 9. SKC 05 0 F000 TP + N pan assemblies, complete with busbars + earth / neutral bars. (range 250 A) 2 2 H W D mm 35 29 3 59 99 0 20 20 20 20 20 20 20 0 0 0 0 0 0 0 EPB25-PA30C EPB25-PA30C EPB25-PA30C EPB25-PA32C EPB25-PA3C EPB25-PA3C EPB25-PA32C SKP 0 00 C005 SKP 0 00 C005 SKP 0 00 C005 SKP 2 00 C005 SKP 00 C005 SKP 00 C005 SKP 2 00 C005 3. 3..3 5.2..2 9. SKC05C05
Distribution Boards Mini Center compact SKC 05 09 F000 Application Mini Center compact distribution boards, a design aimed for safety, reliability and availability in the electrical building installation. Available in busbar and multi row types. Flush mounting only, (surface on request). Supplied without incoming device or outgoing protection device. Technical Data Standard : IEC 39-3 & BS 039 part & 3 Multi row type Ma. load : 00 amps Ma. voltage : 230 / V ac, 50 / 0 Hz Range :, 32,, and 0 modules, 2, 3, and 5 rows Busbar type Ma. load : 0 amps Available in 250 amps on request Ma. voltage : 230 / V ac, 50 / 0 Hz Range :,,, 2 and TP&N 2,, 2, 3 and SP&N Degree of protection : IP, pan assemblies IP Enclosure material : Cold rolled sheet steel Bo and cover mm (Aluzinc steel on request) Enclosure finish : Gray, RAL 035 Fault level : 35 ka Multi row type a distribution boards (distance between rows 50mm) rows 2 3 5 modules 32 0 H W D mm 3 50 90 0 990 32 32 32 32 32 EMC RXF EMC 232 RXF EMC 3 RXF EMC RXF EMC 50 RXF SKM 22 C000 SKM 232 22 C000 SKM 3 22 C000 SKM 22 C000 SKM 50 22 C000 0. 3 SKC 05 0 F000 TP + N busbar type distribution boards TP 2 H W D mm 50 00 50 5 0 32 32 32 32 32 EMC 32 CF- EMC 3 CF- EMC 32 CF- EMC 33 CF- EMC 3 CF- SKM 0 22 C0 SKM 0 22 C0 SKM 0 22 C0 SKM 2 22 C0 SKM 22 C0. 3.... SKC 05 02 F000 Mini Center accessories Top etension boes Type Sheet steel flap / Row Sheet steel flap / 2Row H W D mm 2 5 5 EMC 0S EXB F EMC S EXB F SKA 25 22 C000 SKA 255 22 C000.5.5 Top / Bottom etension boes for flush mounting Type Plain cover Plain cover H W D mm 2 5 5 EMC 0 EXB F EMC EXB F SKA 252 22 C000 SKA 253 22 C000.5.5 9 SKC05C05
Distribution boards Mounting kits for compact The TP + N busbar type distribution boards are delivered as standard without incoming kits or incoming devices these need to be ordered separately. SKC 05 022 F000 Standard kits (Included with the distribution boards but can also be ordered separately as spares) Covers for unused connection busbar points ( Strip For, - 2 Strip For, 2-3 Strip For, - Strip For 2 ) Labels for outgoing circuits on door and trim cover (L,L2,L3) to suit the board configuration. Two keys for door lock. Kit parts list. Instruction leaflet. Kit No. Incoming Device 0 2 2 3 pole isolator or MCB EPB KIT 0-C EPB KIT 0-2C EPB KIT 0-3C EPB KIT 0-C EPB KIT 0-5C EPB KIT 0-C EPB KIT 0-C SKA 0 000 C002 SKA 0 000 C003 SKA 0 000 C00 SKA 0 000 C005 SKA 0 000 C00 SKA 0 000 C00 SKA 0 000 C00 0.0 0.0 0.0 0.0 0.0 0.0 0.05 SKC 05 023 F000 Isolator Incoming kit Terminal shroud. Cover plate with 3 module opening. DIN Rail mounting bracket for incoming device. Kit parts list. Instruction leaflet. Kit No. Incoming Device 3 pole isolator or MCB EPB KIT C SKA 000 C00 0.2 SKC 05 02 F000 RCCB Incoming kit Terminal shroud. Cover plate. DIN Rail mounting bracket for incoming device. Neutral wire link (fleible blue mm 2 ) Kit parts list. Instruction leaflet. Kit No. Incoming Device 2 pole RCCB F 0 series EPB KIT 2C SKA 2 000 C00 0.2 SKC 05 025 F000 Connection kit For TP+N distribution board with DIN Rail (MX version) For connection of pole isolator to pole RCCB and RCCB to the main busbar terminals and neutral bar Coloured fleible cables and comb busbar to connect incoming devices to main Busbars. Terminals shroud. Kit parts list. Instruction leaflet. Kit No. EPB KIT C SKA 000 C00 0. 0 SKC05C05
Distribution boards Mounting kits for compact (continued) SKC 05 02 F000 MCCB Incoming kit Copper connector pieces for L, L2, L3 complete with fiing screws and washers Terminal shroud. Cover plate with opening for T or T3. Kit parts list. Instruction leaflet. Kit No. Incoming Device T ma T T ma T3 EPB KIT -TC SKA 000 C300 EPB KIT -T3C SKA 000 C3003 0.3 0. SKC 05 02 F000 Direct cable connection kit (0 mm) Copper connector pieces for L, L2, L3 complete with fiing screws, washers and support. 2 Terminal shroud. Cover plate. Kit parts list. Instruction leaflet. Kit No. Incoming Device 0 mm direct EPB KIT C SKA 000 C300 0.2 SKC 05 02 F000 Direct cable connection kit ( mm) Copper connector pieces for L, L2, L3 complete with fiing screws, washers and support. Two terminal shrouds. Cover plate. Kit parts list. Instruction leaflet. Kit No. Incoming Device 3 mm direct EPB KIT 3C SKA 3 000 C300 0.5 SKC 05 029 F000 Single phase conversion kit Copper connector piece complete with fiing screws and washers. Terminal shroud. Cover plate. DIN Rail mounting bracket for incoming device. Neutral wire link (fleible blue mm 2 ). Kit parts list. Instruction leaflet. Kit No. EPB KIT C SKA 000 C300 0. SKC 05 030 F000 Joining kit Used to mount two Protecta distribution boards, side by side or Protecta distribution board with side etension bo. One kit is used for all distribution board configurations. 3 rubber gaskets. joining bolts 5 mm complete with fiing washers Kit parts list. Instruction leaflet. Kit No. 5 EPB KIT 5 SKA 5 000 C000 0.0 SKC05C05
Distribution boards Spare parts and general accessories Spare parts and general accessories SKC 05 03 F000 Description SZ-BP2 GJF 0 902 R000 0.05 SKC 05 032 F000 Blanking plates used to cover unused MCB in the consumer units and distribution boards front cover supplied in a strip of 2 modules. Busbar terminal cover used to cover unused outgoing busbar terminals supplied in a strip of 5 pieces. SZ-BSK 2CDL 0 00 R00 0.003 SKC 05 033 F000 Copper connection terminal for connecting incoming cable to neutral or earth terminal bars. NPE-CT SKB 0 0 P000 0.03 Terminal shroud MTSH-C SKA 3 000 C000 0.0 SKC 05 03 F000 Front facia cover PEFC-C SKA 3 000 C000 SKC 05 035 F000 SKC 05 03 F000 Neutral terminal bar kit complete Terminal bar. 2 Terminal bar carrier (support). Kit shield cover. Warning label-small size. Copper cable connector complete with screw and washers. 2 White numbering labels for N terminal bars. Work instruction. Description N-bar 9 holes complete with screws & shield cover way N-bar 3 holes complete with screws & shield cover way N-bar holes complete with screws & shield cover way N-bar 2 holes complete with screws & shield cover 2 way N-bar 3& holes complete with screws & shield cover way N-bar &2 holes complete with screws & shield cover way N-bar 2&2 holes complete with screws & shield cover 2 way NTB - 0 W NTB - 0 W NTB - 0 W NTB - 2 W NTB - W NTB - W NTB - 2 W SKP 0 9 R000 SKP 0 9 R0002 SKP 0 9 R0003 SKP 0 9 R000 SKP 0 9 R0005 SKP 0 9 R000 SKP 0 9 R000 0.2 0. 0. 0. 0.2 0.32 0.3 SKC 05 03 F000 Earth terminal bar kit complete Terminal bar. Copper cable connector complete with screw and washers. 2 Yellow numbering labels for PE terminal bars. Work instruction. Description PE-bar 9 holes complete with screws way PE-bar 3 holes complete with screws way PE-bar holes complete with screws way PE-bar 2 holes complete with screws 2 way PE-bar 3& holes complete with screws way PE-bar &2 holes complete with screws way PE-bar 2&2 holes complete with screws 2 way PETB - 0 W PETB - 0 W PETB - 0 W PETB - 2 W PETB - W PETB - W PETB - 2 W SKP 0 9 R000 SKP 0 9 R0002 SKP 0 9 R0003 SKP 0 9 R000 SKP 0 9 R0005 SKP 0 9 R000 SKP 0 9 R000 0.0 0. 0.2 0. 0.9 0.23 0.25 2 SKC05C05
Consumer Units Dimensional details Comby plastic flap consumer unit surface mounted C 2 Modules C (mm) ECT 0 S ECT S ECT S ECT S 0 3 25 22 3 9 23 3 0 33 292 3 250 2 Comby plastic flap consumer unit flush mounted C Modules C (mm) 2 ECT 0 F ECT F ECT F ECT F 0 3 25 22 3 229 23 3 0 33 292 3 250 2 2 Comby steel flap consumer unit surface mounted C ECS 0 DS ECS DS ECS DS ECS DS Modules 0 3 25 22 3 9 23 3 0 C (mm) 33 292 3 250 2 3 SKC05C05
Consumer Units Dimensional details (continued) Comby steel flap consumer unit flush mounted 2 C ECS 0 DF ECS DF ECS DF ECS DF Modules 0 3 25 22 3 229 23 3 0 C (mm) 33 292 3 250 2 Housemaster compact sheet steal consumer unit surface mounted C 2 HSMS 0C HSRC 0C HSMS 0C HSRC 0C HSMS C HSRC C HSSL +C HSMS C HSRC C HSSL +C HSMS C HSRC C HSSL +C Modules 9 3 22 52 25 35 3 55 20 23 3 0 C (mm) 33 292 30 Housemaster compact plastic consumer unit surface mounted A B 22 22 23 HMMS 0C HMRC 0C HMMS 0C HMRC 0C HMMS C HMRC C HMSL +C HMMS C HMRC C HMSL +C HMMS C HMRC C HMSL +C Modules 9 3 22 90 230 300 30 0 00 0 20 20 350 SKC05C05
Distribution Boards Dimensional details (continued) Protecta compact single row distribution boards surface mounted O/G Modules C (mm) C ECS 0C ECS 0C ECS C ECS C ECS C 52 25 35 3 55 20 23 3 0 33 292 30 2 Protecta multi row distribution boards Ways EPA 0 EPA 02 EPA 03 EPA 0 EPA 05 32 0 20 502 50 00 000 9 332 3 5 29 29 Protecta compact busbar type distribution boards Ways 29 EPB25-30C EPB 30 MXC EPB25-30C EPB 30 MXC EPB25-30C EPB 30 MXC EPB25-32C EPB 32 MXC EPB25-3C EPB25-3C EPB25-32C 2 2 502 50 0 30 000 0 332 3 3 5 5 29 99 5 SKC05C05
Distribution Boards Dimensional details (continued) Minicenter multi row distribution boards 29 25 3 32 32 EMC RXF EMC 232 RXF EMC 3 RXF EMC RXF EMC 50 RXF Modules 32 0 3 50 90 0 990 9 32 2 5 3 C (mm) 2 9 50 9 A C B Minicenter busbar type distribution boards C (mm) EMC 32 CF- EMC 3 CF- EMC 32 CF- EMC 33 CF- EMC 3 CF- 2 50 00 50 5 0 3 32 2 53 2 9 55 0 2 29 32 Protecta compact pan assemblies 20 252 235 B EPB 30 PAC- EPB25-PA30C EPB 30 PAC- EPB25-PA30C EPB 30 PAC- EPB25-PA30C EPB 32 PAC- EPB25-PA32C EPB 3 PAC- EPB25-PA3C EPB 3 PAC- EPB25-PA3C EPB 32 PAC- EPB25-PA32C Ways 2 2 35 29 3 59 99 5 0 2 30 52 0 Depth 0 mm. SKC05C05
Contact us ABB Dr. Mohamed Kamel Hussein St., El Nozha El Gedeida, Heliopolis. Cairo, Egypt. Tel.: + 2 222 0 Sales Tel.: + 2 225-225 Fa: + 2 222 22 paul.north@eg.abb.com www.abb.com/mea/lowvoltage As part of its on-going product improvement, ABB reserves the right to modify the characteristics or the products described in this document. The information given is notcontractual. For further details please contact the ABB company marketing these products in your country. No:SKC05C05 - Printed in Egypt (Mar. 09) - ein advertising designs