PR - PCB relay. devices of automation and control

Similar documents
Elesta Elektrotechnik AG industry relays and accessories

SKR - industry relay

RY2 miniature industrial relays

SPST-NO SPDT DPST-NO DPDT

Goodsky Technical Data. Contact Details

40 Series - Miniature PCB/Plug-in relays A. Features

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Pluggable interface relays CR-P Pcb relays

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

LAUBE TECHNOLOGY DRY REED RELAYS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

1a/1c 5A/10A small power relays

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Surface Mounting Relay

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

AZ420 MINIATURE GENERAL PURPOSE RELAY

1 POLE - 5A SLIM POWER RELAY

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

38 Series - Relay interface modules A

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Product Catalogue. Relays with forcibly guided contacts

Inductive Proximity Sensors

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

38 Series - Relay interface modules A

Model Number Structure

Model Number Structure

SPST-NO SPDT DPST-NO DPDT

2 POLES - 5A LOW PROFILE TYPE

CQM1-SF200/CS1W-SF200

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

RM4TG20 three-phase network control relay RM4-T - range V

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

49 Series - Relay interface modules A. Features

FP2 Relay. The Best Relaytion

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

1 POLE - 8A Medium Load Control

Cable Plug acc. to DIN EN , Form A

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Type: DILM9 10(24VDC) Article No.:

Surface Mounting Relay

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Contact expansion modules

General-purpose Relay

3-phase, bidirectional energy meter

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Data Sheet. Electro-mechanical counters Hengstler 800 series

E-STOP relays, safety gate monitors

DISCONTINUED (1998) MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES. RoHS compliant

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

Solid State Timers Type F

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

48 SERIES Relay interface modules 10 A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Application Note TMA Series

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Contact expander modules

Safety technique. Emergency stop module BO 5988 safemaster

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

DISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

PNOZsigma - Base units

60 Series - General purpose relays 6-10 A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

WINGLIKE ELECTRONICS CO.,LTD

Features. Type List 832A

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Transcription:

PR - PCB relay the PR-PCB relay PCB-Relay from the PR family are small relays. The version has forced guided contacts, 2 normally open contacts, 2 normally closed contacts. In the industrial electronic as well as in the control industry they are used as fail-save elements. The forced guided contact version are often used in control systems of high safe applications. By using best materials and because of the simple construction the highest failsecurity was achieved. High precision in mechanical and electrical control guarantees the high and stable quality of the relays. features applications simple fail-save construction high switching power high load current extraordinary life time high contact force security distance according to VDE and CSA minimal dimensions the forced guided contact version, SUVA approved. devices of automation and control 42 catalog 2002 e / 04.03

type number key PR 4... 024 VDC coil voltage VDC = direct current standard voltage VDC: 024, 110 option F = flat version H = tall version relay version PR 4 (forced guided contacts) order sample PR 4 F 024 VDC - PCB-relay with forced guided contacts - flat version - coil voltage 24 VDC catalog 2002 e / 04.03 43

PR 4F - PCB relay PCB-relay with forced guided contacts, flat version with 2 normally open contacts, and 2 normally closed contacts order numbers contact specifications (see data sheet for curves) serial version PR 4F.. VDC contact material contact type nominal switching capacity electric life expectancy inrush current switching current range switching power range AgCuNi single contact 250 VAC 6 A AC1 1500 VA app. 100'000 operations 250 VAC 6A AC1 (360 Schaltung/h) 15 A for 200 ms 50 ma to 6A 0,3VA to 1500VA general data mechanic life expectancy > 20 x 10 6 operations mechanical switching frequency 20 Hz pull-in time 10 ms release time 2,5 ms bounce time normally open contact 6 ms bounce time break contact 6 ms test voltage, coil/contact 2'000 V eff / 50 Hz test voltage, open contact 1'500 V eff insulation resistance 2x10 11 Ohm weight 30 g installation situation any ambient temperature max. +60 C tests, instructions certificates CSA, VDE, SUVA 44 catalog 2002 e / 04.03

3,0 45,1 2,5 36,4 27,9 7x2,54 3,0 5,08 ø 1,3 mm ± 0,1 20,3 circuit diagram (view from the top) drilling plan (view on solder side) dimensions 45,1 36,4 12,2 1x0,2 5,08 2,5 20,3 7x2,54 27,9 3,0 coil specifications standard coils for direct current (other voltages on enquiry) rated pull-in reset nominal resistance voltage voltage voltage current Ohm tolerance VDC at 20 C at 20 C ma at 20 C % 6 5,1 0,3 222 27 +/-10 12 10,2 0,6 109 110 +/-10 24 20,4 1,2 54,5 440 +/-10 48 40,8 2,4 30 1'600 +/-10 110 93,5 5,5 10,3 10'600 +/-13 catalog 2002 e / 04.03 45

PR 4H - PCB relay PCB-relay with forced guided contacts, tall version with 2 normally open contacts, and 2 normally closed contacts order numbers contact specifications (see data sheet for curves) serial version PR4H.. VDC contact material contact type nominal switching capacity electric life expectancy inrush current max. switching current range switching power range AgCuNi single contact 250 VAC 6 A AC1 1500 VA app. 100'000 operations 250 VAC 6A AC1 (360 operations/h) 15 A for 200 ms 50 ma to 6A 0,3VA to 1500VA general data mechanic life expectancy > 20 x 10 6 operations mechanical switching frequency 20 Hz pull-in time 10 ms release time 2,5 ms bounce time normally open contact 6 ms bounce time break contact 6 ms test voltage, coil/contact 2'000 V eff / 50 Hz test voltage, open contact 1'500 V eff insulation resistance 2x10 11 Ohm weight 30 g installation situation any ambient temperature max. +60 C tests, instructions certificates CSA, VDE, SUVA 46 catalog 2002 e / 04.03

ø 1,3 mm ± 0,1 7,62 13,3 7x2,54 20,3 45,5 2,9 2,9 circuit diagram (view from the top) drilling plan (view on solder side) dimensions 36,1 2,9 20,3 7x2,54 45,5 1x0,2 2,9 7,62 13,3 3,0 coil specifications standard coils for direct current (other voltages on enquiry) rated min. pull-in release nominal resistance voltage voltage voltage current Ohm tolerance VDC at 20 C at 20 C ma at 20 C % 6 5,1 0,3 222 27 +/-10 12 10,2 0,6 109 110 +/-10 24 20,4 1,2 54,5 440 +/-10 48 40,8 2,4 30 1'600 +/-10 110 93,5 5,5 10,3 10'600 +/-13 contact specifications (AgCuNi 6A single contact) current (A) 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 DC breaking capacity 0,1 0 50 100 150 200 250 voltage (VDC) 1) inductive load, L/R 40 ms 2) resitive load 2 data valid for relay contact material contact type nominal switching capacity electric life expectancy inrush current max. switching current range* switching power range* contact resistance *typical values PR 4F PR 4H AgCuNi (AgCu1,8Ni0,12) single contact 250VAC 6A AC1 1500VA app. 100'000 operations 250 VAC 6A AC1 (360 operations/h) 15A for 200 ms 50mA to 6A 0,3VA(W) to 1500VA(W) 120mΩ in the new condition catalog 2002 e / 04.03 47