Recommended Practice for Transit Bus Electrical System Requirements related to Fire Safety

Similar documents
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Batteries in HP notebooks

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

16. APTA PR-IM-S Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance

SECTION FIRE ALARM AND DETECTION SYSTEMS

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

17. APTA PR-IM-S Standard for Third Rail Current Collection Equipment Periodic Inspection and Maintenance

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

70-Series CAN Power Management System

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

ABS Flash Code (Blink Code) Instructions

1 General Responsibility. 1.1 Participants. 1.2 Documentation. 1.3 Lockout/Tagout

Ducoterra Radiant Heating Panel Installation Manual

VLT Series 300 Watt True Sine Wave Inverter

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

DTW Works Master Specification Version 2006

Understanding Emergency Power Off (EPO)

SECTION VARIABLE FREQUENCY DRIVES

VoltMaster Battery Equalizer

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

AC and DC Drive System Installation Information

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Load Cell Troubleshooting

Signature and ISX CM870 Electronics

Software... pg 3 File Maintenance Training

Qualitative Analysis of Power Distribution Configurations for Data Centers

Evaluating Water-Damaged Electrical Equipment

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Electronic Power Control

SECTION FIRE ALARM AND DETECTION SYSTEM

Battery Power Inverters

Module 4, Lesson 12 Fire Alarm Systems

Manual for Fire Suppression & Methane Detection System

NEC Class 2 Power Circuits and Power Supplies

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Guidance on Proper Use of EXTENSION CORDS, POWER STRIPS & SURGE PROTECTORS

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

3000W Power Inverter

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

INSTALLATION & SERVICE MANUAL. Display Panel

TROUBLESHOOTING ABS DIAGNOSTIC CODES L20293, Rev. 1/13

Installation and Operation Guide PD4600 Series Converter Replacement

Design and Construction Standards SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

v 1.42b Conceal-Alarm Information Packet for Fire Alarm System Contractors & Installers Conceal -Alarm

Evaluating Water-Damaged Electrical Equipment

PUSH BUTTON START INSTALLATION MANUAL

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

12 Volt 30 Amp Digital Solar Charge Controller

Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

R02GA. July 31, Dear Blue Bird Owner:

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

AMPSEAL* Automotive Plug Connector and Header Assembly

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

Subject: Circuit Board troubleshooting Bulletin


ST Series POWER SUPPLIES USER INSTRUCTIONS

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Residential Electrical System Aging Research Project. Dave Dini Sr. Research Engineer Underwriters Laboratories

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

Current Transformer (CT) Selection Guide

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

INSPECTION AND TESTING OF EMERGENCY GENERATORS

Arc Fault Circuit Interrupters Frequently Asked Questions

Installation and Operation Guide for PD4000 Series Power Control Center

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

Road Vehicles - Diagnostic Systems

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Evaluating Water-Damaged Electrical Equipment

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Bypass transfer switch mechanisms

Mobile Data Power Model: MDP-25

MODEL 2202IQ (1991-MSRP $549.00)

PENNTEX FOUR-STEP CHARGING SYSTEM TEST AND GENERAL INFORMATION FOR ANY PENNTEX SYSTEM EXCEPT 2009-UP FORDS WITH A PX-7000 VOLTAGE REGULATOR

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

DRAFT REGULATORY GUIDE DG-1154 (Proposed Revision 2 of Regulatory Guide 1.128, dated October 1978)

HERNANDO COUNTY FIRE ALARM GUIDELINES

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

OUTPUT CABLE CONNECTIONS:

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Transcription:

Recommended Practice for Transit Bus Electrical System Requirements related to Fire Safety Approved August 6, 2007 APTA Bus Safety Working Group Approved October 10, 2007 APTA Bus Safety Committee Approved December 15, 2007 APTA Bus Standards Task Force Abstract: This recommended practice provides guidelines for vehicle systems shut down in case of detected fire. Keywords: fire, suppression, detection, fire suppression, bus fire, vehicle fire, engine fire, wheel fire, tire fire Copyright 2007 by The American Public Transportation Association 1666 K Street, N. W. Washington, DC, 20006, USA No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of The American Public Transportation Association.

Introduction (This introduction is not a part of APTA BT-RP-002-07 Recommended Practice for Transit Bus Fire Safety Shutdown.) This Recommended Practice for Transit Bus Fire Safety Shutdown reflects the consensus of the APTA Bus Standards Program members on the items, methods, and procedures that have provided the best practice based on the experiences of those present and participating in meetings of the Program Task Forces and Working Groups. Recommended practices are voluntary, industry-developed, and consensus-based practices that assist equipment suppliers, vehicle and component manufacturers, and maintenance personnel in the construction, assembly, operation, and maintenance of transit bus vehicles. Recommended practices may include test methodologies and informational documents. Recommended practices are non-exclusive and voluntary; they are intended to neither endorse nor discourage the use of any product or procedure. All areas and items included herein are subject to manufacturers supplemental or superceding recommendations. APTA recognizes that for certain applications, the practices, as implemented by operating agencies, may be either more or less restrictive than those given in this document. This recommended practice provides guidelines for transit bus vehicle systems shut down in conjunction with a vehicle fire. APTA recommends the use of this recommended practice by: Individuals or organizations that inspect and maintain transit buses Individuals or organizations that develop specifications for transit buses Individuals or organizations that build or manufacturer fire suppression systems Individuals or organizations that contract with others for the inspection and maintenance of transit buses Individuals or organizations that influence how transit buses are inspected and maintained Test results must meet or exceed federal, state, or other local regulatory agency requirements if different from the recommendations outlined in this document. Participants The American Public Transportation Association (APTA) greatly appreciates the contributions of the Bus Transit Standards Bus Fire Working Group, who provided the primary effort in drafting the Recommended Practice for Transit Bus Shut Down. ii

Contents 1. Overview... 1 1.1 Scope... 1 1.2 Purpose... 1 2. References... 1 3. Definitions, abbreviations, and acronyms... 1 3.1 Definitions... 1 3.2 Abbreviations and acronyms... 2 4. Routing and Securement of Electrical Harnesses and Components... 2 5. Detection/Notification Shut Down Processes... 2 5.1 Electrical System Detection and Protection Circuit Breaker - Baseline Protection... 2 5.1.1 Optional Multiplex:- Enhanced Protection Technology 3 5.1.2 Other Enhanced monitoring and protection devices- Emerging Technology 3 iii

Recommended Practice for Transit Bus Electrical System Requirements related to Fire Safety 1. Overview This document identifies transit bus electrical control system recommended practice related to fire safety. Individual operating agencies may modify these guidelines to accommodate their specific equipment and mode of operation. Fire protection systems should not be a substitute for proper engineering design and maintenance practices. This recommended practice should be used in conjunction with the original equipment manufacturer (OEM) recommendations. 1.1 Scope This recommended practice provides guidelines for transit bus electrical control system configuration for electrical circuits related to fire safety. This RP does not apply to high voltage systems of more than 12/24 volt systems such as those seen in hybrid/fuel cell electrical systems or all electric buses. 1.2 Purpose The purpose of this recommended practice is to prevent, detect and reduce the occurrence of vehicle electrical fires. The practice covers vehicle electrical equipment that will provide detection and circuit shutdown of defective electrical components or systems. 2. References This recommended practice shall be used in conjunction with the most recent edition of SAE Standards and Recommended Practices such as but not limited to: J1455, J1113, J1127, J1128, J1939, J1292, J1708, UL 935 type CC and NEC. 3. Definitions, abbreviations, and acronyms For the purposes of this recommended practice, the following terms, definitions, abbreviations, and acronyms apply. 3.1 Definitions For the purpose of this document the following words are used as defined. 3.1.1 Electrical fire: A thermal event that may result from one of the following: Incorrect 1

assembly, moisture leading to corrosion, wires pulled loose,overheating due to over-current and over-voltage, arcing, chaffing/worn insulation, incorrect wire size, poor splices, poor electrical connection and/or failure of an electrical component. 3.1.2 Arc detection: The sensing of a possible arcing condition in a electrical or component circuit. 3.2 Abbreviations and acronyms OEM Original equipment manufacturer (vehicle manufacturer) SAE Society of Automotive Engineers UL Underwriters Laboratories, Inc. VNAS Vehicle Network Access System NEC National Electrical Code 4. Routing and Securement of Electrical Harnesses and Components All wiring, and cables must be properly routed, bracketed, insulated, and isolated to avoid chaffing and to protect from heat sources. Wiring should be routed to avoid damage from abrasion pinch points, heat, road debris, excessive stretching and damage from the exhaust system and turbocharger. Engine component connections should be water proofed or shielded to prevent the intrusion of moisture. UL listed or equivalent wire for fire suppression system applications must be used. Use heat shields where other alternatives are not possible. Heat shields should be designed and installed in accordance with applicable SAE and NFPA standards. 5. Detection/Notification Shut Down Processes 5.1 Electrical System Detection and Protection Circuit Breaker - Baseline Protection All branch circuits, except battery-to-starting motor and battery-to-generator/alternator circuits, shall be protected by circuit breakers or fuses sized to the requirements of the load. Electronic circuit protection for the cranking motor shall be provided to prevent engaging of the motor for more than 30 seconds at a time to prevent overheating. The circuit breakers or fuses should be easily accessible for authorized personnel. Fuses should be used only where circuit breakers are not practical. Any manually re-settable circuit breakers shall provide visible indication of open circuits. Components should be protected to fail in a safe manner. Circuit breakers or fuses shall be sized approximately 15 percent larger than the total circuit load current. The current rating for the wire used for each circuit must exceed the size of the circuit protection being used. Wire and cable amperage for wire sizes 18 AWG and larger shall be in accordance with the Wire amperage Chart found in Appendix B. 2

5.1.1 Optional Multiplex:- Enhanced Protection Technology APTA BTS-BS-RP-002-07 Upon detection of an arcing condition, the vehicle multiplexing system will detect the arcing condition. The system shall provide visual and audible notification in the operator s area. The system will automatically shut down selected outputs when current draw exceeds preset limits. Data logger shall have the ability to recall multiplex system input/output/j1939 status settings for retrieval of system malfunctions. Where data logging exists consider the use of diagnostic data management software. Justification for system override to enable the operator to move or return the vehicle to the base of operation should be developed and maintained by the transit system. 5.1.2 Other Enhanced monitoring and protection devices- Emerging Technology 5.1.3.1 Lighting System Ballast Detection and Protection The Inverter Ballast may include circuitry that detects arcing within the lamp panels wiring harness as defined by UL 935 Type CC. Upon detection of an arcing condition the individual ballast detecting an arcing condition must automatically and immediately shutdown power to the circuit. The ballast shall provide a visible red LED indicator light identifying the ballast of concern. The vehicle restart procedure must not be able to supply power to the ballast if the arcing conditions still exist. 3