The only One you need.

Similar documents
SECTION DETECTION AND ALARM

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Temperature & Humidity SMS Alert Controller

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Repeaters and Mimics Data Sheet

HyperAccess Access Control System

FIREDEX Conventional Fire Panels

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

UniOP epad33 and epad33t

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

AC-115 Compact Networked Single Door Controller. Installation and User Manual

OPTICAL FIBER repeaters/ isolators

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Always on the Lookout Perfect Protection against Burglary

Product Information Fire alarm panel 8000 C

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

GST301. (Single Protection Zone) Operation Manual

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Fire alarm system EBL512 G3

GSM Voice Auto Dialer & SMS Sender JC-999

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

DCS Data and communication server

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Controller board and power supply for vivimat III systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

AIS750 Series Alarm Annunciator

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

Electronic Control Devices The European Product Catalogue 2007

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

SMART SENSOR COLLECTION

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ABB RTU560A Series CMU & Modules

NC-12 Modbus Application

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

HMI display Installation Guide

EN54-16 Voice Alarm System PRODUCT DATASHEETS

PCS0100en Persy Control Services B.V. Netherlands

TECNOALARM INTERNATIONAL LEADER OF SECURITY

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Automation Unit TM 1703 ACP Flexible automation and telecontrol

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

A-317. Mobile Data Terminal. Android Platform Datasheet

TX2123 RS485 TO ETHERNET ADAPTOR

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Phase Modular Finally the benefits of Modular ups are for all

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ACCESS CONTROL SYSTEM

SNMP Web Management. User s Manual For SNMP Web Card/Box

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

500r+ Installation and User Guide

Conventional Fire Detection and Extinguishant Control System Specification

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Remote Monitoring and REC 501 Control Unit Product Guide

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

TrueAlarm Fire Alarm Systems

FLYPORT Wi-Fi G

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

M2M/IoT Solutions.

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

User manual Rev 1.3 Contents

V350-R34 V350J-R34. npn inputs pnp inputs

OPT SERIAL TO FIBER OPTIC CONVERTER

GSM Alarm System User Manual

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

IntesisBox Modbus Server Fidelio IP

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SMS GSM Alarm Messenger

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

DCS data and communication server

Embedded & Industrial PCs International Products and Configurations INDEX

MultiViu Flex 7 Data Sheet

Produktnr. Navn Salgspris ekskl. moms

Regards from the Team at Rheology Solutions.

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Transcription:

The only One you need.

FIRE DETECTION Solution The TELEDATA products for the fire detection are compliant to the legislations in force EN 54/2 54/4 related to the fire detection (EN 54-2) and the power supply (EN 54-4). The TELEDATA fire detection panels are capable to manage up to 240 detectors for loop offering solutions from 1 loop (TELEDATA ONE) up to 16 loops (OLYMPIA). TELEDATA offers technical innovations such as The use of a digital comunication protocol on 2 voltage levels with the improvement of the quality and the reliability of the loop communication and the distance increment of the closed loop up to 6 Km. Elegant design and available for all the different applications. Available also in analog addressable version. The short cut detection integrated in the analog addressable modules and detectors, avoiding the use of external insulators. The system management becomes easier by using the model ONE KBD remote keypads with push buttons, display and signaling LEDs. The management of the control panel can be done by using any communication line or Ethernet network using the appropriate WINWATCH32 software. The management of the fire control panels on graphic maps is integrated with the management of burglar, CCTV, access control and building automation systems.

MAIN Alarms Faults Exclusion Test Events INSERT CODE INSERT CODE USER Events Assistance Mantenance Silence Evacuation Assistance Mantenance Evacuation 6 FIRE System

FIRE System CONFIGURATION System Input/Output Code Clock AUTOPROGRAMMING Sensor n. 002 found Module Input n. 069 found Module Output n. 069 found Module Expander n. 218 found FIRE System 7

8 FIRE System

FIRE System LANGUEGE FIRE System 9

10 FIRE System

FIRE System 11

Addressed digital panels > TELEDATA ONE 1 loop expandable to 9 addressable fire alarm control panel HARDWARE features 32 bit microprocessor addressable control panel 1 loop addressable with digital protocol configured as open or close. Expandable up to 9 loops 240 addressable devices each loop. Graphic touch screen display (480x272 TFT 4.3 ) Loop short circuit protection. 14 front LEDs 1 monitored output for siren or dialer (24Vdc 1A) general form C output 1A 30Vdc 120 Vac 1 general open collector output 1 RS 485 line for peripherals 1 RS 232/micro USB for programming or monitoring station Programmable colored side led 1 Ethernet 10 Mbit/s management card (OPTIONAL board PTLAN) 56 area led. (OPTIONAL board ONE 56) 1 Extinguishing channel (OPTIONAL board ONE EXT) 1 redundancy management card (OPTIONAL board ONE RDD) Management of networ between fire panels (OPTIONAL board ONE RING) Batteries capacity: 2 x 17Ah with EN54-4 charger management Monitored aux power supply output 24 Vdc 500mA with short protection Dimensions: 410x410x120 mm Power Supply: 230Vac Software features Up to 240 addressable devices for loop Hybrid fire panel for wired or wireless detectors Up to 192 independent detection zones 192 logic functions Archival more than 1000 events Auto programming analog loops Auto addressing analog loops Devices Mapping. Connection with control panels using a fault tolerant network Multiple language management Fully customizable with personal logo, color, touch screen and multicolored side LEDs Management detectors and analog modules of different types: - Thermal and optical detectors mixed - Input Modules - Output Modules - Addressable call points - Addressable sirens Multiprotocol Selectable colored LEDs Programmable locally or remotely via dedicated software on serial or LAN / WAN Multiprotocol Teledata Apollo and Wizmart MODBUS RTU Protocol (OPTIONAL board MCGTWMDB) Product certified to EN54-2 and EN54-4 standards 12 FIRE System

> ONE 2 Expansion card 2 loops for Teledata One Functional features: The Teledata One Expansion board lets you expand Teledata One detection capacity in terms of number of loops, two at a time, to a maximum of 9 loops. Technical specifications: 2-loop expansion board for Teledata One EN54-2 standard certified device Loops can be set as open or closed loops with consequent fault management Maximum number of devices per loop: 240 Assembly inside the unit on specific connection on the master board Nr. 2 programmable monitored alarm output relays Multiprotocol Teledata Apollo and Wizmart > ONE RING Network card for Olympia and Teledata One control panel CAN BUS connection Up to 32 control panels in the network Up to 50 Kbps data transmission. Fault tolerant connection, in case of fault it assures the necessary communication using a ring connection Compatible with Olympia fire panel and Teledata One Internal mounting in Olympia fire panel Up to 1,2Km cable length Consumption: 250mA max Power supply: 12Vdc from Olympia fire panel > ONE KBD Remote keyboard touch screen to fire panel Teledata One Graphic display touchscreen (480x272 TFT 4.3 ) 14 LEDs Front 2 RS 485 for connection 1 RS 232 / micro USB for programming Operating temperature: 5 C / + 40 C. Power supply: 24Vdc Power consumption: 100mA > ONE 56 Card area led for TELEDATA ONE Card for the management of the zone alarm status n viewable zone: 56 area led. Operating temperature: 5 C / + 40 C. dimensions: 219x58mm FIRE System 13

> ONE EXT 1 extinguishing channel board Teledata One *on request 2016 Functional features: The Teledata One Extinguishing board lets you equip the Teledata One fire detection unit with an output to manage an extinguisher channel (single system management). Technical specifications: One channel extinguisher board for Teledata one unit EN 12094 standard certified device 2 monitored output relays for 1st stage and 2nd stage sirens 2 power free contact output relays for alarm and pre-alarm 1 power free contact output relay for removal 2 self-calibrating outputs for explosive capsules 1 end extinguishing open collector output 1 monitored manual extinguisher input button 1 release feedback monitored input 1 monitored input for system pressure gauge 2 general purpose monitored inputs > ONE RDD Board for redundant performance implementation to increase Teledata One reliability *on request 2016 Technical and Functional Specifications: The Teledata redundancy board lets you equip the Teledata One fire detection unit with a hot back-up system in the event of fault that can involve some unit sections to increase the unit s level of reliability. The redundancy board keeps master, slave and serial board operations under constant control in the event of fault that generates a functional block, the redundancy board recognizes the fault and physically replaces the faulty section, inserting its electronic parts in the circuit. The purpose of the board is to detect and provide backup for the following faults: Master board loop fault Master board microprocessor fault Slave board loop fault Slave board microprocessor fault Serial port faults > MCGTWMDB Protocol converter for MODBUS protocol HARDWARE features: Unit microprocessor controlled 133 MHz 32Mbytes Flash expandable to 64Mbytes 32Mbytes Ram expandable to 64Mbytes Embedded Operating System Network interface card Ethernet 10 100 Base T Integrated 1 RS232 serial line protocol for interfacing with central IEC 79/5-79/6 Internal battery backup Power supply: 12Vdc Power consumption: 480 ma Operating Temperature: 0-50 Relative Humidity: 0% -95% Weight: 3,5Kg Dimensions: 208x152x65mm FUNCTIONAL Protocol converter on MODBUS RTU over TCP / IP or Modbus TCP / IP by RS232 serial CEI 79/5-79/6 Prepared for future expansion and customization according to specific projects. 14 FIRE System

> TKE Remote keypad panel for EOLO and OLYMPIA fire control panel 40x2 character LCD display with back-light function 17 status LEDs 19 function buttons: Silence, Reset, Silence/rearm sounder alarm, Status, Arrow Up, Down, Left and Right buttons, ENTER key, Numerical keys from 0 to 9 Remote management (max 4 keyboards) for Eolo and Olympia panels Can be connected to all addressable analog panels Mechanical key for use of the keyboard Metal case Wall or desk version available Dimensions: 230x120x45 Power supply: 24Vdc Current absorption: 50mA max > OLY 4 4 loop expansion card for Olympia control panel Mounted inside the control panel. 1 generic relay alarm output 1A 30Vdc 120 Vac 1 fault relay output 1A 30Vdc 120 Vac Configuration of 4 loops Closed or Open The maximum capacity for each loop is 240 detectors/modules, for a total of 3,840 devices for a 16 loop configuration. These applications are to assembled to EN-54 Standards, however it is necessary to keep in mind the mandatory limit of 512 devices per OLY4 (4 loop) card, for a total of 2,084 devices. > ONE RING Network card for Olympia and Teledata One control panel CAN BUS connection Up to 32 control panels in the network Up to 50 Kbps data transmission. Fault tolerant connection, in case of fault it assures the necessary communication using a ring connection Compatible with Olympia fire panel Internal mounting in Olympia fire panel Up to 1,2Km cable length Consumption: 250mA max Power supply: 12Vdc from Olympia fire panel > FDCANMONO Mono mode optical fibre converter with ST connector for Olynet card *on request Power supply: 12Vcc > FDCANMULTI Multi mode optical fibre converter with ST connector for Olynet card *on request Power supply: 12Vcc 16 FIRE System

SERVER NETWORK LOOP (32) FDM5411 EXTINGUISHER PANEL UP TO 9 LOOP PT LAN TELEDATA ONE SF3500 [240] FDS100 [240] FDVMC12 SF2000 [240] CLIENT SF1000 [240] TKE (4) FDVMC120 [240] FDVMM120 [240] ALLARME INCENDIO PR40 (1) FD5965 [1] FDBF100R (1) TCP\IP NETWORK (CAT5 cable) RS485 LINE (Shielded, antiflame cable with 2 connectors for power supply and 2 connectors RS484 for signal) SIGNAL (Shielded, antiflame cable with 2 connectors for signal and 2 connectors for power supply) POWER SUPPLY AND SIGNAL (Shielded, antiflame cable with 2 connectors for signal and power supply) WIRELESS (Radio connection with 870 MHZ Frequence) NETWORK LOOP (Cat 5 cable) CLOSE (Shielde for sign

D [240] NSF20 (1) ASPIRATING SMOKE DETECTOR WIRELESS CONNECTION 0 [240] G55-500 [240] FDS5505ID FDVMC100 [240] FDVMM120 [240] FDVCP100 [240] FDWVMI 100 [32] FDW2W (7) WIRED CONNECTION FDSLPG100 [32] FDVMCZ100 FDVMIC402 [240] FDVMM120 [240] SWF 1000 [32] FDWCP100 [32] ALLARME INCENDIO SF100 [32] SF400 [32] NSF20 [4] FD5965 [1] FBF100R (4) FBF100A (1) RS232 (Cable with 9 connector for signal) LOOP WITH POWER SUPPLY d, antiflame cable with 2 connectors al and power supply) (x) = Maximum Number of connected device. The devices can be added tougher ex: (x) + (x) [x] = Maximum Number of connected device. The device cannot be added tougher ex: (x) or (x)

Headquarters via G.M. Giulietti, 8-20132 Milan - Italy - tel.: +39 02 27 201 352 r.a. - +39 02 25 92 795 - fax: +39 02 25 93 704 - mail: info@teledata-i.com R&D 56010 Ghezzano (Pisa) - Via Carducci. 64 - mail: info@teledata-i.com Middle East Office Dubai Airport Free Zone - 3rd East Wing, 4th Floor - PO Bo. 54620 Dubai UAE - Phone +971 (0)4 2149670 - Fax +971 (0) 4 214 9501 - mail: info@teledata-i.com