Network Operation and Troubleshooting

Similar documents
PLC Master / Slave Example

KOYO DIRECT. HMI Setting: PLC Setting: Supported Series: KOYO DirectLogic series PLC DL05, DL06, DL105, DL205, DL305, and DL405 series.

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Date Rev. Details Author

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

RS-232 COMMUNICATIONS

Modbus Communications for PanelView Terminals

ISHIDA BC Scale to Scale Communications

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Introduction: Implementation of the MVI56-MCM module for modbus communications:

L5354 ControlNet Communications Interface

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Bluetooth HC-06 with serial port module Easy guide

How to make a diagnostic on TeSysT to start the network?

Bluetooth Serial Adapter

Toshiba Serial Driver Help Kepware Technologies

Connecting UniOP to Telemecanique PLC s

Single channel data transceiver module WIZ2-434

Modbus RTU Master Communications

CENTRONICS interface and Parallel Printer Port LPT

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

OP Communications Master. Manual Number OP M

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

USER GUIDE Programming Adapter Cable for Fujitsu Flash Microcontroller- F²MC-16LX/FR Family Fujitsu Microelectronics America, Inc.

7.7 Ethernet Communication (AFPX-COM5)

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Allen-Bradley/Rockwell

Microcontroller Based Low Cost Portable PC Mouse and Keyboard Tester

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

CB15/CB155. PROFIBUS Module

LOCAL INTERCONNECT NETWORK (LIN)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

PLC Support Software at Jefferson Lab

LTM-1338B. Plus Communications Manual

SCADA System. Application Guide

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

Modbus RTU Master Communications

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

GW-7552 PRIFIBUS/MODBUS GATEWAY

Series Six Plus Programmable Controller

Open Field Network CC-Link Troubleshooting Guide

Bluetooth to Serial Adapter

BACnet Automation Interface Module (Network Version)

Technical description MX-1 VB Edge

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version /18/2009

Cable Pinouts. SRP I/O Module

IP SERIAL DEVICE SERVER

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

PCM2000 Configuration Guide

User Manuals. Connection to Siemens S5 PU (AS511) Part Number: Version: 2. Date:

LOCAL INTERCONNECT NETWORK (LIN)

RN-XV-RD2 Evaluation Board

POS Integration. Prepared by: Binh Nguyen

Troubleshooting and Diagnostics

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Omron I/O Driver (Series 2) Programmable Serial Interface Card

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

MDI FAQ. Version 8.1.0a Page 1 of 16

Encore Controller to Router Connections

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

E-series/E1000-series Cable Guide

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

CDI-S100 SERIAL INTERFACE CARD

Modbus RTU Communications RX/WX and MRX/MWX

PagePac PAGEPAL V

is then retained absolutely without interruption.

Teleservice via RS232 interface XC100/XC200

LOCAL INTERCONNECT NETWORK (LIN)

Stevens Cell-Net CDMA & GSM M2M 3G Data Modem. Product Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

APPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction Key Concepts... 4

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

USER S MANUAL. Settop RadioLink. Settop DataConvert. Rev. March

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

How to setup a serial Bluetooth adapter Master Guide

APNT#1168 Modbus - Establishing Communications Hints

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

HSG Engineering Tech Bulletin

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

USER S MANUAL Communication Function

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Commissioning IDENTControl Compact IC-KP2-2HB17-2V1D Profinet Protocol with a Siemens S7 PLC

OPT SERIAL TO FIBER OPTIC CONVERTER

ATS Communication Overview

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Modbus Protocol. PDF format version of the MODBUS Protocol. The original was found at:

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

This Datasheet for the IC697CPM790. GMR Redundancy CPU, 486, 2K Triplex (voted) I/O.

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

Transcription:

and Troubleshooting

7 2 and Troubleshooting Starting the Network PLC as Master Networks If you re using a PLC as the master station, you must put the CPU in Run mode before the communications program can be executed. This is because the PLC master uses RLL instructions included in your application program to initiate the data transfer requests. There are two ways to place the CPUs in run mode. Turn the keyswitch to the RUN position. Turn the keyswitch to the TERM position and use a programming device to change the operating mode. PLC Peer as Master Networks Host as Master Networks Slave Stations PLC Peer master networks require both CPUs be in Run mode, since either station can initiate data transfer requests. Both stations contain the necessary RLL instructions. Host master networks require a DirectNET communications program to manage the data requests. If you re using a host software package you should check the documentation that came with it for network startup information. If you created your own DirectNET program, you ll have to execute the program file to get things started. Check the documentation for your particular programming language to determine the steps required to execute program files. Depending on your application, you may also have to place the slave PLCs in Run mode to obtain meaningful data. The DCM and DCU interfaces also have On-line switches that must be in the On-line position before communications can begin. CPUs with built-in ports do not necessarily have to be in Run mode, but again the data may not be current.

and Troubleshooting 7 3 Troubleshooting First Place to Look Try an Example Program If the network does not seem to be working correctly, check the following items. 1. Cable and connections. Incorrectly wired cables and loose connectors cause the majority of problems. Verify you ve selected the proper cable configuration and check to see the cable is wired correctly. 2. Switch settings. Make sure you ve set the slave stations to match the communication parameters required by the master station (DCM, operator interface or host computer). 3. Incorrect protocol. Make sure your network stations are all set for the same protocol. DirectNET networks can use the DirectNET or HostLink/CCM2 protocol selections. 4. Communications program. Check the communications program for errors. Sometimes it is helpful to have an example you can try. AppendicesA,B, andc provide examples of the three network configurations. You can quickly and easily build a small network to make sure you are following all the appropriate steps. These are especially helpful if this is your first DirectNET application. CPUs with Built-in DirectNET Ports Host Masters Most problems that occur with the CPUs are related to communication settings. Check the switch settings, and/or use a programming device to check the station address. DirectNET programs must manage all aspects of network communication including timing considerations. Chapter 6 provides information on network timing issues that can affect network performance. Communication Interface Indicators The communications interfaces, DCMs and DCUs, have indicators that are specifically for communication status. The following paragraphs show these indicators and describe their meanings.

7 4 and Troubleshooting DL405 DCM Indicators Check the DCM indicators to verify the DCM is operating correctly. The following diagram shows the proper indicator conditions. Module Power: ON NAK: ON if a NAK is either sent or received TOUT: ON if a timeout has occurred in the DCM Master Mode: ON if master OFF if slave Self Test Indicator: ON Send/Receive Enquiry: FLASHING Send/Receive Header: FLASHING Send/Receive Data Packet: FLASHING The following table provides additional troubleshooting details for the DL405 DCM.

and Troubleshooting 7 5 Indicator Status Possible Cause Corrective Action PWR or OK off PLC power is disconnected DCM is defective Check the PLC source power. Replace the DCM. MSTR off (and DCM is in a master station) Switch setting is incorrect Remove power from the PLC, remove the DCM and check switch positions1 and 2 on SW5. ENQ indicator does not come on when communications program is executed ENQ stays on, but NAK, TOUT, or HDR indicators do not come on at all The PLC master station is not in Run mode Online / Offline switch is in the Offline position Communications program is not correct Communication timeout is disabled RTS and CTS signals are not looped back on the master station end of the cable Place the PLC in Run mode. Set the switch to Online. Check the communications program. Verify the address, amount of data, and data type are correct. Remove power from the PLC, remove the DCM, and check switch position 3 on SW5. Remove master station connector, ensure that RTS and CTS are connected according to the cable diagram. ENQ comes on and TOUT indicator flashes RLL communications program is not correct Modes are different Communication cable Check the communications program. Verify the address is correct. Set baud rate, parity, and mode (HEX/ASCII) to match the master station. Verify the cable is wired according to the cable pinouts. ENQ indicator comes on and NAK indicator flashes (slave responds, but the data is incorrect) Modes are different Communication cable Set baud rate, parity, and mode (HEX/ASCII) to match the master station. Make sure the + and connections are correct (RS422). Check pin 7 (GND) if you re using RS232C. ENQ and HDR indicators come on and the NAK indicator flashes Communications program is not correct Modes are different Check the amount of data being transferred. You must use the correct byte boundaries for the data type being used. Set baud rate, parity, and mode (HEX/ASCII) to match the master station. DATA indicator is on, but the NAK indicator comes on intermittently Electrical noise Make sure the system has good earth grounds. Only one end of the cable shield should be grounded. If you re using RS232C, try using RS422.

7 6 and Troubleshooting DL305 DCU Indicators Check the DCU indicators to verify the DCU is operating correctly. The following diagram shows the proper indicator conditions. On when PLC is in Run Mode On when data is being transmitted RUN DATA On when PLC battery needs replacing BATT CPU DIAG PWR On when internal diagnostic tests are complete On when CPU watchdog timer has expired On when base power is on. If an external power supply is used, both base power and the external supply must be on.

and Troubleshooting 7 7 The following table provides additional troubleshooting details for the DL305 DCU. Indicator Status Possible Cause Corrective Action PWR off PLC power is disconnected DCU is not connected to the CPU properly Check the PLC source power. Make sure the DCU is securely fastened to the CPU and that no connector pins are bent. DCU external power source (if used) is Check the external power source. not connected DCU is defective Replace the DCU DIAG off DCU is defective Replace the DCU DATA does not flash during communications Loose or incorrectly wired cable Online / Offline switch is in the Offline position Communications program is not correct Check the cable connections and pinouts. Set the switch to Online. Check the master communications program. Verify the address, amount of data, and data type are correct. (See Appendices D, E, and F for address references.)