Choosing the correct surge protection equipment.

Similar documents
keeping air fresher MaxAir REFRESHINGLY POWERFUL clipsal.com

Power surges can also be generated by equipment in your facility such as:

HomeSafe Security Panel User s Guide 5400 Series

SURGE PROTECTIVE DEVICES

Transient and Lightning Protection for the Water Industries

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Electrical safety and protection devices

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Electrical Safety Tips. Help us keep you safe

Lightning Arresters P KVA P KVA. Description & Installation

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

CATALOGUE SURGE PROTECTION LOW VOLTAGE

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

DIRECT STRIKE PROTECTION. CAT Terminal, Gold, Model III

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

Advanced Power Supply Topics

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Video Camera Installation Guide

A series of technology briefs spanning Tyco Electronics product portfolio

Product Technical Training. Life Care and Patient Monitoring Systems

C-Bus Network Monitor

1 Introduction. 2 Hazards From Electricity

weatherprotected accessories technical data Switches, Sockets and Enclosures

Telecommunication Line Protectors

Line Reactors and AC Drives

Residual Current Circuit Breaker

38 Series - Relay interface modules A

TAN-058 Application Note Sept 7, 2006

Tutorial- Create a cascading drop-down control

R.C.C.B. s two-pole LEXIC

38 Series - Relay interface modules A

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

How To Build A Low Voltage Capacitor Lvcp

Australian live sheep exports

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

RADIANT PLASMA 4700 Plasma Spark Generator

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

POWER FACTOR CORRECTION

RM4TG20 three-phase network control relay RM4-T - range V

How To Understand The Electrical Power Supply Of A Power Supply System

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Electrical Resistance Resistance (R)

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

49 Series - Relay interface modules A. Features

The standards mentioned in this document

Dali Lighting Products

RC NETWORKS SALES GUIDE

HOW TO SELECT VARISTORS

Insights into IT Professionals (Australia) Manpower Market Insights Paper

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Surge protection for emergency alarm systems

Brochure. Solar energy Lightning and surge protective devices

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

WE HAVE THE RIGHT POWER SUPPLY FOR YOUR APPLICATION

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Unified requirements for systems with voltages above 1 kv up to 15 kv

LM117 LM317A LM317 3-Terminal Adjustable Regulator

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Report On Surge Protection & Voltage Fluctuation

Power Quality for Information Technology System

5SV Residual Current Protective Devices

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Bourns Resistive Products

AC-DC Converter Application Guidelines

Model 1756 Test Lead Kit

heavy motor Product Profile

Why Buy HVI VLF Products?

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MasterINTERFACE 39 Series - Relay interface modules

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

wietap wietap Overvoltage Protection Tensions running high

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

This is a preview - click here to buy the full publication TECHNICAL REPORT

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Protect. Surge Protection for home and small office

Capacitors. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Electrical Shore Connections / Cold Ironing

SurgeShield. Section A: What is SurgeShield?

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

White paper. ABB solutions for switching and protection of low speed wind turbines

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

The complete range of consumer switchboards and switchgear

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Transcription:

Choosing the correct surge protection equipment. An easy to use guide for contractors. clipsal.com

Surge protection made easy We invest thousands of dollars in state-of-the-art electronic equipment and insure it against theft and damage. But when it comes to protection against damage caused by overvoltage surges we re sometimes unaware of what is available. The causes of surges are many and varied. By far the most common cause is through switching operations in the network. Surge damage caused by lightning strikes also occurs frequently. Computers are one of the most relied on tools of the trade and the information stored in them can be irreplaceable if lost. Fax machines, photocopiers and valuable printing equipment all need protection from the hazards of lightning strikes. Overvoltage peaks lasting only some millionths of a second, can cause the failure of a semiconductor module and destroy the whole system. Protection is gained by connecting all possible conductive paths to earth at the instant the overvoltage appears within the installation and thereby breaking up the otherwise harmful surge. It can be difficult to know which parameters are important when selecting surge protection equipment. The following information has been prepared to help you. The Safe Protection Concept Test Wave Forms Test wave forms are used to emulate real life transients from which surge protection devices are designed. Below in yellow shows the transient a spark gap product must endure during a direct lightning strike. Below in green shows the transient a varistor must endure during a switching transient or an indirect lightning strike. OVERVOLTAGE ARRESTER LIGHTNING CURRENT ARRESTER Power Range Arresters As a first protective measure, a barrier is necessary to keep the lightning current out of the system. Spark Gaps respond to the lightning current impulse of 10/350µS at the required level and break it to a current impulse of 8/20µS tolerable for subsequent Surge Protection Devices. When using Spark Gaps in the power supply system, the mains follow on current must be safely extinguished after discharging a current impulse. As a second protective measure, the remaining current impulse (approx. 8/20µS) is discharged and limited to a voltage level compatible with the system. A varistor (non-linear resistor) is ideal for this task. Modern metal oxide varistors are distinguished by their fast response time and low residual voltage (voltage protection level). 2 What does 20kA (8/20µS) mean? 20kA is the impulse current. 8/20µS. The first value (8) is the rise time (from 10% to 90% of peak). The second value (20) is the duration for the test transient to decrease to half its peak value.

Surge Protection Devices Electrical equipment will be vulnerable if exposed to voltages greater than 1.5kV, particularly with sensitive electronic equipment at voltages greater than 800V. Clipsal Surge Protection Devices work to reduce overvoltages to figures less than 800V. To do this most effectively, there are three methods of combating the likelihood of this danger to equipment occurring. Method of Protection Method 1 (Lightning Current) Method 2 (Overvoltage) Method 3 (Overvoltage Filtering) Spark Gap Arresters are heavyduty devices that work on a similar principle to a car spark plug. (i.e., when energy is large enough it jumps the gap to earth.) These devices can handle high currents similar to direct lightning strikes, however leave a relative high residual voltage less than 4kV. (Not suitable for equipment protection, but reduces energy to a manageable level.) The most common and inexpensive first line of defence against a power surge is a Metal Oxide Varistor (MOV). Clipsal Overvoltage Arresters have a discharge capacity of 20kA (8/20µS). The component that protects electrical equipment from overvoltages will withstand this current impulse at least 20 times, non destructively and without changes to its characteristic. These devices will give voltage protection less than 1 to 1.5kV (8/20µS), and are used in locations that are exposed to indirect lightning strikes and switching transients. Mains Filters provide additional overvoltage protection to protect sensitive electronic equipment. The Clipsal Mains Filters are used in conjunction with overvoltage protection by providing additional filtering to slow down the rate of rise of voltage spill and reduce let through voltage to less than 800V. 3

Methods of Protection Low risk protection, methods 2 and 3 discussed on page 3 suit installations vulnerable due to switching transients and indirect lightning strikes. As a guide indirect lightning strikes 1.5 kilometres away can generate surge voltage into the kilovolt range which can be protected by this method. Below are schematics of typical installation methods. Low Risk Protection Low Risk Medium Protection Low Risk Fine Protection 4 Note - Fault current limiting pre-fuse not shown

Methods of Protection High risk protection methods 1, 2 and 3 discussed on page 3 suit installations that could receive direct lightning strikes. This type of installation provides enhanced protection and customer peace of mind. High Risk Protection High Risk Medium Protection High Risk Fine Protection Note - Fault current limiting pre-fuse not shown 5

Power range surge arresters 950/4 950/4 High Capacity 4 Pole Arrester Combined overvoltage and current arrester (spark gap, inductor and metal oxide varistor) DIN mounted 6.5 modules wide Surge current 65kA (4/10) 4 pole Maximum pre-fuse 100A gl Fast and easy installation Provides lightning current and overvoltage protection (lightning protection) Visual indication when overloaded and replacement required Must replace whole unit (higher material cost) Care taken during installation due to blow out path 970RMT 970 970 Overvoltage Arrester (Metal Oxide Varistor) 275V, 20kA 1 pole DIN 1 module wide Maximum pre-fuse 125A gl First line of protection against overvoltages Fast and easy installation Provides overvoltage protection Does not protect from a direct lightning strike Visual indication when overloaded and replacement required Must disconnect wiring to remove 970LCA 970RM 970RM Overvoltage Arrester (Metal Oxide Varistor) 275V, 20kA 1 pole DIN 1 module wide Maximum pre-fuse 125A gl First line of protection against overvoltages Fast and easy installation Provides overvoltage protection Removable modules allow quick replacement without the need to disconnect wiring Does not protect against a direct lightning strike Visual indication when overloaded and replacement required 970/3LCA 6

970RMT Overvoltage Arrester As for 970RM with the added advantage of auxiliary contacts that can be used to alert when 970 module requires replacement. 970LCA Lightning Current Arrester (Spark Gap) 264V, 25kA, 1 pole DIN 2 module wide Maximum pre-fuse 100A gl For increased protection against direct lightning strikes Provides protection against direct lightning strikes Fully encapsulated no blow out path Never requires replacing Must be used with decoupling element 970DE (or 15 metre length of cable) and 970 Overvoltage Arrester. (Refer to the diagrams on page 4 & 5.) 970/3LCALightning Current Arrester (Spark Gap) 264V, 25/75kA, 3 pole DIN 4 module wide Maximum pre-fuse 100A gl For increased protection against direct lightning strikes Provides protection against direct lightning strikes Fully encapsulated no blow out path Never requires replacing Must be used with decoupling element 970DE (or 15 metre length of cable) and 970 Overvoltage Arrester. (Refer to the diagrams on page 4 & 5.) 970DE 463SF 2025SF 970MF10 970DE (Decoupling Element 500V 35A) 970DE63 (Decoupling Element 500V 63A) Provides energy coordination between 970LCA Lightning Current Arrester 2 modules wide and 970 Overvoltage Arrester The 970DE Series can be substituted with15 metres of cable Allows installation of the 970LCA Lightning Current Arrester and the 970 Overvoltage Arrester located side by side in the same switchboard The 970DE is connected in series with the load and therefore maximum through current is limited to 35 Amps (970DE) or 63 Amps (970DE63) 463SF (Metal Oxide Varistor) Surge Filter Plug Adaptor 25SF, C2025SF, 2025SF (metal oxide varistor) Socket Outlet 250V, 10A Power outlet double 250V, 10A - surge protected Surge current 6.5kA 8/20µS A third protective measure if overvoltage possibility exists between the distribution board and the terminal equipment Local protection at point of supply to equipment Provides overvoltage protection Low energy absorption 6.5kA 8/20µS Visual indication when overloaded and replacement required Does not protect from a direct lightning strike 970MF10 / 970MF20 Mains Filter 970MF10-250V, 10A, 2 module wide 970MF20-250V, 20A, 4 modules wide Work in conjunction with the 970 Overvoltage Arrester by providing additional protection to sensitive electronic equipment Additional protection provides filtering to slow down the rate of rise of a voltage spike Never requires replacing Additional space required to switchboard The 970MF is connected in circuit with the load and therefore maximum through current is limited to 10Amps (970MF10) and 20Amps (970MF20) 7

Clipsal Overvoltage Protection Equipment Overvoltage Arresters Cat. No. Description 950/4 High capacity 4 pole overvoltage arrester, DIN mounted 970 Overvoltage arrester, 275V, 20kA 970P Replacement protection plug, 275V, 20kA 970RM Overvoltage arrester with removable module, 275V, 20kA 970T Overvoltage arrester with auxiliary contacts, 275V, 20kA 970RMT Overvoltage arrester with removable module and aux./cont., 275V, 20kA 970MF10 Mains filter 250V 10A 50/60Hz 2 modules wide 970MF20 Mains filter 250V 20A 50/60Hz 4 modules wide 970DE Decoupling element, 500V, 35A 970DE63 Decoupling element, 500V, 63A 970LCA Lightning current arrester, 264V, 25kA 970/3LCA Lightning current arrester, 264V, 25/75kA 3 pole 25SF Power outlet, double, 250V, 10A 463SF Surge filter plug adaptor, 250V, 10A C2025SF Power outlet, double, surge protected 2025SF Power outlet, double 250V, 10A with surge protection 951 Disconnection spark gap 952 Disconnection spark gap type Ex Products of Gerard Industries Pty Ltd ABN 27 007 873 529 Head Office 12 Park Terrace, Bowden South Australia 5007 Telephone (08) 8269 0511 Facsimile (08) 8340 1724 Internet clipsal.com E-Mail plugin@clipsal.com.au International Enquiries Head Office Export Department Telephone +61 8 8269 0587 Facsimile +61 8 8340 7350 E-Mail export@clipsal.com.au Offices in all States NSW Sydney (02) 9794 9200 Albury (02) 6041 2377 VIC Melbourne (03) 9207 3200 Country Areas 1800 653 893 QLD Brisbane (07) 3244 7444 Townsville (07) 4729 3333 SA Adelaide (08) 8269 0555 WA Perth (08) 9442 4444 TAS Hobart (03) 6272 3177 Launceston (03) 6343 5900 NT Darwin (08) 8947 0278 New Zealand Clipsal Industries (NZ) Ltd (Auckland) Telephone (09) 576 3403 Facsimile (09) 576 1015 E-Mail headoffice@clipsal.co.nz Customer Service Free Fax (0508) 250 305 Auckland/Mobile Phone (09) 572 0014 Free Phone (0508) CLIPSAL 254 7725 Printed by Custom Press Pty Ltd (08) 8346 7999 Apr. 01 Order No. 17520