Table of Contents Table of Contents Electrical Power Engineering, Smart Grid Trainers "Smart Grids" - Intelligent power supply networks Supplementary to ESG 1 EUG 3 Pumped-storage hydroelectricity power plant Media: 1 2 2 4 5 8 Lucas Nülle GmbH Page 1/9 www.lucas-nuelle.com
Electrical Power Engineering, Smart Grid Trainers Training systems on the generation, distribution and management of electrical energy: Power engineering training system, distribution training system Energy generation training system, renewable energy generation training system Transformer training system, high-voltage transmission lines training system, protective systems training system Energy management training system, smart grid training systems The Lucas-Nülle training systems have been designed in anticipation of the newest developments: Smart measuring instruments provided with various communication interfaces (e.g. LAN, RS485, USB) and control elements SCADA Power Engineering Lab software for the intelligent control and evaluation of "smart grids" using Soft PLC SCADA software designed for educational purposes Permits investigation of dynamically alternating loads and power generation inside the laboratory Intelligent energy management Modular integration of renewable energies into a smart grid using protective engineering Wind power plant with doubly-fed asynchronous generator (DFIG) and synchronisation to the grid Interactive multimedia training course Training systems on the generation, distribution and management of electrical energy: Power engineering trainer, distribution trainer Energy generation trainer, renewable energy generation trainer Transformer trainer, high-voltage transmission lines trainer, protective systems trainer Energy management trainer, smart grid trainers The Lucas-Nülle training systems have been designed in anticipation of the newest developments: Smart measuring instruments which avail of various communication interfaces (e.g. LAN, RS485, USB) and control elements SCADA Power Engineering Lab software for the intelligent control and evaluation of the "Smart Grid" with soft plc Didactically designed SCADA software Permits investigation of dynamically alternating loads and power generation inside the laboratory Intelligent energy management Modular integration of renewable energies into the smart grid using protective engineering Wind power plant with doubly-fed asynchronous generator (DFIG) with mains sychronisation Interactive multimedia training course "Smart Grids" - Intelligent power supply networks Lucas Nülle GmbH Page 2/9 www.lucas-nuelle.com
"Smart Grids" - Intelligent power supply networks In the future, new technology will better equip power grids for the demands of tomorrow. More flexible grid management should make the increasing proportion of renewable energy sources compatible with conventional infrastructures associated with power stations. The variety and number of these decentralised power plants require a revision in how we manage power grids so-called intelligent networks or "smart grids": Improved coordination of energy requirements and energy generation, e.g. via intelligent switching of loads depending on the energy available Using modern IT technology, like the internet, sensors, control systems and wireless transmission devices "Smart metering" digital current meters measure electricity consumption where customers are connected to the grid Shifting household consumption away from peak load periods Starting flexible applications such as washing machines outside peak load periods, at the initiation of a utility provider The Lucas-Nuelle training systems have been designed in anticipation of these developments: Smart measuring instruments provided with various communication interfaces (e.g. LAN, RS485, USB) and control elements SCADA Power Engineering Lab software for the intelligent control and evaluation of smart grids using Soft PLC SCADA software designed for educational purposes Permits investigation of dynamically alternating loads and power generation inside the laboratory Intelligent energy management Modular integration of renewable energies into a smart grid using protective engineering Wind power plant with doubly-fed asynchronous generator (DFIG) and synchronisation to the grid Interactive multimedia training course Training system on the generation, transmission, distribution, protection and management of electrical energy: Energy management, smart grid training system Energy generation, regenerative energy generation High-voltage transmission lines, protective systems Lucas Nülle GmbH Page 3/9 www.lucas-nuelle.com
Supplementary to ESG 1 Supplementary to ESG 1 The following equipment sets on energy generation can be used optionally either individually or in combination to supplement the "ESG 1 Smart Grid" equipment set. As such extensive experiments can be realised to explore the "Smart Grid". Lucas Nülle GmbH Page 4/9 www.lucas-nuelle.com
EUG 3 Pumped-storage hydroelectricity power plant EUG 3 Pumped-storage hydroelectricity power plant In pumped storage hydroelectricity power stations electric energy is stored by converting the potential energy of water and then converting this potential energy into electrical power which is then fed back into the grid. Thanks to the growth in regenerative energy generation these so-called hydroelectric power storage stations are not only necessary but indispensable in smart power grids with high grid quality. Training content: How pumped storage power plants operate Start and synchronisation of synchronous machines Manual power regulation: both in generator and motor modes Semi-automatic active and reactive power control Smart grid integration of pumped storage power plants Fully-automatic compensation for externally measured active and reactive power SCADA open and closed-loop system control Basic equipment set, consisting of: Basic equipment set, consisting of: 1 HMI (Human Machine Interface) for generators CO3301-5L 1 2 Synchronization Unit CO3212-6V 1 3 Multi-function relay, power controller, cos-phi controller, synchronizing unit CO3301-5W 1 Lucas Nülle GmbH Page 5/9 www.lucas-nuelle.com
4 Power switch module CO3301-5P 1 5 Variable Ohmic load, three-phase, 1kW CO3301-3F 1 6 Inductive load, three-phase, 1kW CO3301-3D 1 7 Three-phase synchronous machine with smooth core rotor, 1kW SE2662-5Q 1 Additionally required - Machine test bench equipment set for servo-drive/braking system: 8 Servo machine test bench for 1kW machines incl. ActiveServo software(d,gb,f,e) CO3636-6W 1 9 Rubber coupling sleeve, 1kW SE2662-6A 1 10 Coupling guard, 1kW SE2662-6B 1 11 Shaft end guard, 1kW SE2662-6C 1 12 QuickChart, Servo-machine test stand safety and operating instructions (GB) SO6200-7D 1 Power supply: 13 Universal power supply for electrical machines CO3212-5U 1 14 Exciter voltage controller with de-excitation CO3301-5G 1 15 Motor protection switch, 3 pole, 1.8-2.5A CO3212-1P 1 Lucas Nülle GmbH Page 6/9 www.lucas-nuelle.com
16 Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J 1 Measuring instruments: 17 Three-phase power quality meter, display and long-term memory CO5127-1S 1 Lucas Nülle GmbH Page 7/9 www.lucas-nuelle.com
Media: 18 Interactive Lab Assistant: Pumped-Storage power station SO2800-9T 1 Additionally recommended 19 Interactive Lab Assistant: AC Synchronisation and Automatic Generator Control SO2800-9E 1 20 Interactive Lab Assistant: Generator protection SO2800-9G 1 Software: 21 Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM9057 1 22 USB Network Adapter 10/100 BaseTX RJ45 LM9056 1 23 5-Port Ethernet Switch LM9988 1 Accessories: 24 Double busbar unit, three-phase, incoming / outgoing feeder CO3301-5R 1 25 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R 40 26 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 Lucas Nülle GmbH Page 8/9 www.lucas-nuelle.com
27 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W 2 28 Set of safety measurement cables, 4mm (31 leads) SO5148-1L 1 29 Safety measurement cable (4mm), 150cm, brown SO5126-9J 2 30 Safety measurement cable (4mm), 150cm, black SO5126-9G 2 31 Safety measurement cable (4mm), 150cm, grey SO5126-9N 2 32 Safety measurement cable (4mm), 150cm, blue SO5126-9K 2 33 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 34 Protected power distribution for working stations ST8008-8M 1 35 Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E 1 36 PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 37 Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T 1 38 Keyboard adapter for flat screen monitor holders ST8010-4G 1 39 Protection cover for three-level experiment trolleys ST8010-9Y 1 Lucas Nülle GmbH Page 9/9 www.lucas-nuelle.com