PROPER HANGING OF FIRE SPRINKLER SYSTEMS IFSA. All rights reserved.

Similar documents
SECTION PIPE HANGERS AND SUPPORTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Guidelines for Earthquake Bracing of Residential Water Heaters

Residential Deck Safety, Construction, and Repair

POST AND FRAME STRUCTURES (Pole Barns)

Guidelines for Earthquake Bracing Residential Water Heaters

Seismic Technical Guide

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

PART 1 GENERAL 1.1 SECTION INCLUDES

PIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG

PERIMETER FLASHING. Table of Contents

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Hilti, Inc South 122 nd East Avenue Tulsa, OK

It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool

4 Installation Requirements

Connection Solutions

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Chapter 10 - Scaffolding Systems

Fire protection solutions

4 of /7/ :51 PM

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013

STANDARD OPEN PATIO COVER

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Dock Hardware & Accessory Products Catalog

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

POWERS Controls No. 4 Pneumatic Damper Actuator

EAST LYME HIGH SCHOOL

AMF112 Instruction Manual

FINAL December 2012 SECTION DUCTWORK

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

2006 Codes. Please verify the following before calling for inspection

Boiler Plan II Table of Contents

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1

800 Communications Circuits

INSTALLATION OF A BAY WINDOW

Wisconsin Building Products Evaluation

CDGRD-10. Grounding. Solutions For Comm/Data Applications

BUILD A TABLETOP LOOM

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Uncovered Decks & Porches

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

CABLE SUPPORT SYSTEMS

lindab duct suspension & support system Duct suspensions & Support systems

Featuring TJ Rim Board and TimberStrand LSL

Mark Cramer Inspection Services, Inc.

RPS - sales@rpssolar.com San Bruno Cove, San Diego, CA 92130

Les Produits MURPHCO Ltée

DTU Animal Cart Programme

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC)

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

This mount uses concrete parking bumpers and a Davis tripod to create a mounting solution for nonpenetrable

I BEAM TRACK INSTALLATION

During severe flood events, such as those

Ceiling Mounted Folding Attic Ladders Installation Instructions

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

CPA Steel Stud Framing Page 1 of 11

STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES

Detailing of Reinforcment in Concrete Structures

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Fire Barrier Duct Wrap 15A

AMF112 ( <00>) 13mm (1/2 in.)

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

F-Series Camera Mounting Accessories

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

WATER SERVICE 2

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Installation Instructions Hustler 6-BTV Trap Vertical

Chapter. Restoration of Damaged Structures

Excerpts from the Canadian National Building Code (NBC)

Chapter 3 Pre-Installation, Foundations and Piers

MRI RF SHIELDING DESIGN

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).

Transcription:

PROPER HANGING OF FIRE SPRINKLER SYSTEMS 2010 IFSA. All rights reserved. 1

HANGING PER NFPA 13 2 Historical developments and basic concepts Hangers Hanger installation Special listed pipe Hangers in earthquake areas Trapeze hangers Ends of lines and armovers Riser support

NFPA 13 HANGER RULES - 1896 3 U type hangers made of round wrought iron or malleable cast iron, ring clips or approved adjustable hangers. Flat U type hangers permitted if at least 3/16 inch thick. Hangers required to be at least 12 inches from sprinklers to avoid interference, except round hangers were permitted as close as 3 inches. For concrete construction, cast iron inserts recommended, but expansion bolts could be used in existing buildings, preferably in a horizontal position.

BASIC CONCEPTS NFPA 13 2010 contains Section 9.1 on Hangers and 9.2 on Installation of Pipe Hangers NFPA 13 basis for other NFPA standards for water based systems: 13R, 14, 15, 16, 750 NFPA 13D requires support methods comparable to those of local plumbing codes. Exception: listed piping must be supported per listing limitations 4

PERFORMANCE OPTION 5 Hangers must meet the requirements of Section 9.1 unless certified by a professional engineer as capable of: supporting five times the weight of the water filled pipe plus 250 lbs (114 kg) at each point of support the points of support are adequate the spacing limitations for the piping material are not exceeded the hanger components are ferrous Detailed calculations to be submitted to AHJ as required

HANGERS The components of hanger assemblies that directly attach to the pipe or to the building structure must be listed. Exception: Mild steel hangers formed from rods. Exception: Fasteners (screws and bolts) per 9.1.3 to 9.1.5. 6 UL 203 listing based on 5 times weight of waterfilled pipe plus 250 lbs (114 kg). Not intended as building design dead load per hanger.

HANGERS - COMPONENTS Hangers and their components must be ferrous. Exceptions: 7 Nonferrous components proven by fire tests to be adequate for the hazard, listed for the purpose, and in compliance with the requirements of the standard Holes through structural members permitted to serve as hangers if permitted by applicable building codes

HANGERS - TYPES Defined by how they attach to the structure and the sprinkler piping 8

ATTACHMENT TO STRUCTURE Ceiling Flanges Side Beam Attachments Beam and C clamps Concrete Inserts and Expansion Shields Straps and U hooks Lag Screws and Coach Screw Rods Powder driven Studs and Welding Studs 9

ATTACHMENT TO STRUCTURE As part of listing, C clamps are tested in each possible mounting position unless otherwise marked. Some structural engineers prefer attachment of hanging loads to top flanges. 10

ATTACHMENT TO PIPE Riser Clamps Adjustable Swivel Rings or Loops J hangers Clevis Hangers Straps and U hooks (straps must be listed) 11

CONCRETE INSERTS AND EXPANSION SHIELDS Listed inserts permitted Listed expansion shields permitted except: With cinder concrete, permitted only for branch lines where alternated with through bolts or beam hangers Only in side of concrete beams (above centerline or above reinforcing steel) or vertically under Section 9.1.3.7 12

POWDER-DRIVEN AND WELDING STUDS 13 Studs and installation tools must be listed Steel should not be less than 3/16 inch (4.2 mm) thick for powder driven studs Representative samples of concrete must be tested for minimum loads per 9.1.3.9.3 Steel must be not less than US standard 12 gauge (2.78 mm) for welded attachment of welding studs or other hanger parts Increaser couplings must be directly attached to powder driven studs or welding studs

RODS AND U-HOOKS Hanger rod, U hook rod and eye rod diameters depend on the pipe size being supported, with minimum 3/8 inch (10 mm) diameter (5/16 inch (7.9 mm) for U hooks) unless part of listed hanger assembly Table 9.1.2.1 Hanger rods Table 9.1.2.4 U hook rods 14 Table 9.1.2.5.1 Eye rods Threaded sections of rods shall not be bent or formed

SCREWS AND BOLTS For ceiling flanges and U hooks, minimum screw options and dimensions provided in Table 9.1.5.2.1 Plank t For coach screw rods, minimum plank thickness and beam or joist face width provided in Table 9.1.5.7.2 Beam or joist w 15 Example: for 3 inch pipe, minimum nominal t is 4 inches (102 mm), minimum nominal w is 3 inches (76 mm)

ADDITIONAL HANGER RULES 16 Nails are not acceptable for fastening hangers Holes for lag screws and coach screw rods must be pre drilled 1/8 inch (3.2 mm) less in diameter than screw thread maximum root diameter Bolts must be provided with a flat washer and nut, and holes for bolts must not be more than 1/16 inch (1.6 mm) larger in diameter than the bolt. Eye rods must be secured with lock washers to prevent lateral movement, with flat washer also provided for wood structural members.

INSTALLATION CONSIDERATIONS Hang branch lines perpendicular to close spaced building members such as joists or purlins 17

INSTALLATION OF HANGERS 18 Piping must be supported independently of ceiling sheathing Exception: Toggle hangers permitted under hollow tile or metal lath and plaster for pipe 1 ½inch (40 mm) or smaller Piping in racks must be supported from rack Structure must support weight of the water filled piping plus 250 lbs (114 kg) Exception: 1 inch (25 mm) and smaller branch lines under metal decks Piping under ducts can be supported by common hangers per 9.2.1.5

DISTANCE BETWEEN HANGERS 19 Table 9.2.2.1 based on type and nominal size of pipe Steel pipe maximum 15 ft (4.6 m) spacing, but 12 ft (3.7 m) maximum up to 1 ¼inch (32 mm) and for threaded light wall Other maximums assigned for copper, CPVC, and ductile iron Not less than one hanger for each section of pipe Exception: Lengths less than 6 ft (1.8 m) At least one hanger on cross mains between each two branch lines Exception: Steel mains in bays

EXCEPTIONS FOR STEEL MAINS Where hangers are attached to purlins on all branch lines as near to the cross main as possible, intermediate hangers are permitted to be omitted from steel cross mains in bays: For 2 or 3 branch lines per bay, 1 omitted For 4 or more branch lines per bay, 2 omitted Branch lines Permitted omission Cross main 20

SPECIAL LISTED PIPE Beam strength of special listed pipe a consideration during listing Special hangers now available to avoid harm to nonmetallic piping, usually with flared edges. 21

HANGERS IN EARTHQUAKE AREAS Section 9.3.7 Retaining strap required for all C type clamps (including beam and large flange clamps). Strap to be listed or meet minimum dimensions. In absence of adequate lip, strap to be secured with bolt or screw. 22 Powder driven fasteners not permitted where systems are required to be protected against earthquake accelerations greater than 0.5g unless specially listed.

TRAPEZE HANGERS Considered an extension of the building structure; used to transfer loads to appropriate structural members 23

TRAPEZE HANGERS 24 Minimum required section modulus from Table 9.1.1.6.1(a) must be less than or equal to the minimum available section modulus of proposed trapeze member from Table 9.1.1.6.1(b) Criteria based on simple center loaded steel beam supporting 15 ft (4.6 m) of waterfilled pipe plus 250 lbs (114 kg) with maximum allowable bending stress of 15 ksi (1034.2 bar)

TRAPEZE HANGER EXAMPLE It is desired to support 8 inch Schedule 10 pipe with a trapeze hanger with a span of 5 ft 8 in (1.7 m). Table 9.1.1.6.1(a) requires 0.97 section modulus for 6 ft (1.8 m) span Table 9.1.1.6.1(b) provides 1.04 section modulus for 3 inch Schedule 10 pipe 25

TRAPEZE HANGER EXAMPLE Section 9.1.1.6.5 requires All components of each hanger assembly that attach to a trapeze member shall conform to 9.1.1.4 and be sized to support the suspended sprinkler pipe. 3-inch Schedule 10 26 8-inch Schedule 10

TRAPEZE HANGERS Formula for effective length of trapeze supporting pipe to one side of span: L ab 4 a b 27 This can allow smaller trapeze member

EFFECTIVE LENGTH EXAMPLE For a 6 ft (1.8 m) span with 8 inch Schedule 10 pipe at center of trapeze the required section modulus is 0.97. If pipe is 1 ft (0.3 m) from one support, what is the new section modulus? a 1ft b 5 ft a 0.3m b 1.5m L 4 1 5 1 5 20 6 3.33 ft L 40.31.5 0.3 1.5 1.8 1.8 1.0m 28 With an effective length of 3.33 ft (1.0 m) the required section modulus becomes 0.64

SUPPORT OF ENDS OF LINES Unsupported length at end of branch lines limited to 36 in. (0.9 m) for 1 inch (25 mm) pipe, 48 in. (1.2 m) for 1 1/4 inch (32 mm) pipe or 60 in. (1.5 m) for 1 1/2 inch (40 mm) and larger pipe 29

SUPPORT OF ENDS OF LINES Exception: For pendent sprinklers at 100 psi (7 bar)or higher under ceilings, closest hanger must prevent upward movement, and unsupported length limited to 12 in. (305 mm) for steel or 6 in. (152 mm) for copper 30

SUPPORT OF ENDS OF LINES Special restraint against upward movement for high pressure lines applies only to pendent sprinklers through ceilings Criteria based on 1985 NFSA tests for Texas State Board of Insurance 31

SUPPORT OF ARMOVERS 32 Cumulative horizontal length of unsupported armover must not exceed 24 in. (610 mm) for steel or 12 in. (305 mm) for copper Exception: For pendent sprinklers at 100 psi (7 bar) or higher under ceilings, length limited to 12 in. (305 mm) for steel or 6 in. (152 mm) for copper, and closest hanger must prevent upward movement

33 SPECIAL LISTED HANGERS

RISER SUPPORT Risers to be supported by riser clamps or by hangers on horizontal pipe within 24 inches (610 mm) of riser In multi story buildings, riser supports to be provided at the lowest level, at each alternate level above, above and below offsets, and at the top of riser In high vertical shafts or bays, distance between supports must not exceed 25 ft (7.6 m) 34

CORROSION PROTECTION 8.15.3.2.3 Where corrosive conditions are known to exist due to moisture or fumes, hangers that resist corrosion must be used or a protective coating applied. A 9.2.2 Where copper tube is used in moist areas or or other environments conducive to galvanic corrosion, copper hangers or ferrous hangers with an insulating material should be used. 35

QUESTIONS? www.sprinklerworld.org 36