Design and Development of Energy Efficient Multi-Utility Desert Cooler

Similar documents
Evaporative Cooling System for Aquacultural Production 1

Thermocline Management of Stratified Tanks for Heat Storage

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

Because here you can see a simple an elementary direct evaporative cooling system this is called as a single stage system you can see from the

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Research on the Air Conditioning Water Heater System

Chapter 3.4: HVAC & Refrigeration System

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Performance Test of Solar Assisted Solid Desiccant Dryer

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Experimental Evaluation Of The Frost Formation

Design of Cold Storage Structure For Thousand Tonne Potatoes

Make Your Own SNOWBREEZE AC For Rs.1500 ($30) Can be converted into an energy saving and humidified room heater in winter

Energy Efficiency. Energy Efficient Home Cooling:

The Development of a Frost-Less Heat Pump

Element D Services Heating, Ventilating, and Air Conditioning

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Low Cost. Lower Energy Costs. Higher Efficiency.

Waste Heat Recovery through Air Conditioning System

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Humidity the story for teachers

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Benefits of Cold Aisle Containment During Cooling Failure

White Paper: Free Cooling and the Efficiency of your Data Centre

18th International Congress of Mechanical Engineering

HEAT TRANSFER ANALYSIS OF COLD STORAGE

SECTION MORTUARY REFRIGERATORS

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Energy Efficiency HOSPITALITY.

Innovent LASER Packaged Fresh Air Conditioning Units

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Dehumidification Frequently Asked Questions

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Using Portable Spot Air Conditioners in Industrial Applications

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

AIR CONDITIONING TECHNOLOGY

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

DataCenter 2020: first results for energy-optimization at existing data centers

Solar Hot Water Heaters

ARP Food Industry, Portugal

RESPONSE TIME INDEX OF SPRINKLERS

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

Free Cooling for Data Centers

How Ground/Water Source Heat Pumps Work

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

GEOTHERMAL HEATING AND COOLING INTRODUCTION

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Integration of a fin experiment into the undergraduate heat transfer laboratory

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Peltier Application Note

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Thermal environments. Tel

TABLE OF CONTENT

Investigation into the energy consumption of a data center with a thermosyphon heat exchanger

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

RPV - RP - RA air handling units

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Session 2: Hot Water Supply

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

AdSORPTION CHILLER NAK

Nozzle Vent: A Simpler Approach to Laptop Cooling

The Need. What is CoolBot? What does it do? Low Cost Storage Technology for Farmers, SMEs and entrepreneurs 10/10/2012

HVAC Calculations and Duct Sizing

How To Understand Evaporator

Contents and Nomenclature

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Environmental Data Center Management and Monitoring

We have been working in an ideal climate for thirty years.

Basic Technology Series

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Keggomax CM Reflux Still

How To Improve Energy Efficiency Through Raising Inlet Temperatures

A Cover HVAC ENERGY EFFICIENT

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Transcription:

Available Online at www.environmentaljournal.org All Rights Reserved 2011 Vol 1 39-44 Open Access Research Article Design and Development of Energy Efficient Multi-Utility Desert Cooler 1 Poonia M.P., 2 Bhardwaj A., 3 Upender Pandel, 4 JethooA.S. 1 Professor, Department of Mechanical Engineering, Malaviya National Institute of Technology, Jaipur 2 Associate Professor, Dept. of Mechanical Engineering, Malaviya National Institute of Technology, Jaipur 3 Professor, Department of Metallurgical Engineering, Malaviya National Institute of Technology, Jaipur 4 Associate Professor, Department of Civil Engineering, Malaviya National Institute of Technology, Jaipur Corresponding author asjethoo@gmail.com Abstract An evaporative cooler produces effective cooling by combining a natural process - water evaporation with a simple, reliable air-moving system Evaporative cooling is the most economical and effective means of refrigeration and air cooling since its inception particularly in the areas where climatic conditions are hot and dry. In Rajasthan (India), during summer Dry Bulb Temperature (DBT) of air may reach up to 48 C while relative humidity stays below 50%. During present study efforts were made to make evaporative cooling system more versatile. In the process of study a cooler cum refrigerator has been developed which can be utilized for the purpose of air cooling, drinking water cooling viz. a viz. storing the vegetables and medicines without altering the performance of desert cooler. The energy saving by doing so is saved more than 30 W. A small size desert cooler can cool more than 24 liter water per day up to the Wet Bulb Temperature (WBT) of outside air as well as could store vegetables for more than five days. Keywords Desert cooler, Evaporative cooling, Humidity, Refrigeration 1. Introduction In the North Western part of India, the humidity of air is quite low during summer season whereas dry bulb temperatures are very high. This climate is most suitable for evaporative cooling 1. Fresh outside air is sucked through moist pads where it is cooled by evaporation of water and this cooled air circulated in a room or building by a small fan or blower. Due to vaporisation of water, the temperature may decrease upto the wet bulb temperature of air i.e. around 22 C 2. A simple scientific arrangement for cooling unlimited quantity of safe drinking water - naturally - with the little use of external energy source such as electricity or ice working on the principle of 'cooling by evaporation', the natural water cooler is developed by a local artisan and is made up of indigenous materials only. The water cooler is fabricated using mainly copper tubes and galvanized iron / stainless sheet. It is fitted with a standard make micro-filter for filtering solid particulate and contaminants 3. 39 Prajapati, Mansukhbhai from Rajkot in India, developed a water cooler made with clay and can be operated without electricity. The upper portion of the refrigerator can store about 20 liters of water, while the bottom cabinet has separate space for storing fruits, vegetables and milk. The natural cooling process inside the refrigerator can keep vegetables and fruits fresh for around 5 days, while milk can be preserved for 3 days 4. The developed water cooler during present investigations was fabricated using mainly copper tubes and galvanized iron / stainless sheet. The water cooler is fitted with a standard make micro-filter for filtering solid particulate and contaminants. The water cooler can be connected to overhead water source and is very simple to operate and maintain. During present study efforts have been made to utilize the cold water which is available in the cooler tank at WBT for indirect cooling of drinking water as well as vegetables and various

Universal Journal of Environmental Research and Technology other eatables. The major advantage of this arrangement is to eliminate the possibility of contamination of the stored items, which are to be cooled. With practically no operation & maintenance cost, this type of coolers are ideal for use in n public places such as hospitals, hotels, hostels, industries, offices, institutions etc. for providing cool & hygienically drinking water as well as eatables. Table 1 Technical Specifications of Desert Cooler Motor RPM Air Delivery Wattage Maximum Current Fan diameter Speed Control Water Tank Capacity Length Width Height Portability 2. Experimental Setup 400 4400 m3/hr 185 W 0.95 amp 457 mm Three 51 liter 655mm 634 mm 773 mm Window Mountable The conventional desert cooler used for domestic cooling purpose has been selected for the experimentation. Technical specifications of the desert cooler are given in the Table 1. The view of the developed cooler is shown in photograph. The desert cooler was connected to the insulated Galvanized alvanized Iron (GI) box developed for the present study. The schematic diagram of the experimental set up is shown in the Fig. 1 A C A-DESERTCOOLER D E B-SUBMERSIBLEPUMP C-GALVANIZEDIRONTANK D-COPPERBOX B E-DRINKINGWATERTANK Fig. 1 Photograph of Maru Cooler and Schematic Diagram of the Experimental Set up Box ox is made of double layered Galvanized Iron (GI) sheet (24 SWG).. Between the th two layers (10 cm apart) of G.I. sheets, thermocol is provided as an insulator to reduce heat transfer from cold water to outside air. Same ame thickness of thermocol has been selected which is generally used in ice boxes. Two separate copper boxes were fitted inside the GI box to accommodate drinking water as well as food d items like milk, vegetables etc. Out of two copper boxes, one is used d for storage of drinking water having inlet connection for hot water supply and outlet connection for getting cold drinking water. Brass fits are used in inlet and outlet port and box is sealed so that there will be no contamination in drinking water. Seven en liters water can be stored in this copper box for drinking purpose. Second copper box is used for storage of food items like milk, vegetables etc. for more than three days. 40

3. Performance Study of Existing Cooler To test the utility of the developed water cooler cum storage, exhaustive experimental work has been done. To see the performance of desert cooler various experiments are conducted on existing desert cooler. The velocity of incoming air was measured with the help of anemometer. Table 2 Observations and Performance of Desert Cooler Temperature and humidity of incoming air to the cooler as well as out coming air were measured. On the basis of observations effectiveness of the cooler were calculated. The observations and results are shown in Table 2. Sr. Time Air Temperature in C % Relative Humidity (RH) Water WBT in Effecti No. in min. Outside Air Temp. after Outside Air After cooler Temp C C (T b ) veness Temp. (T 1 ) cooler (T 2 ) % 1. 15 36.5 25.7 19 58 21.2 20.0 65.4 2. 15 36.0 25.8 20 54 20.8 20.0 63.75 3. 27 38.6 26.8 17 51 20.5 20.3 68.3 4. 25 37.5 25.8 18 55 20.0 20.0 68.57 Effectiveness 5,6 of the cooler is defined as the ratio of actual temperature drop of air to maximum possible temperature drop. Effectiveness= (T 1 -T 2 )/ (T 1 -T b ) Where T 1 = Temperature of outside air in 0 C T 2 = Temperature of air coming out from the cooler in 0 C It is clear from the results indicated in Table 2 that water temperature of cooler tank almost reaches to WBT of ambient air. Also we got an average effectiveness of desert cooler equal to 66.5%. 4. Performance of desert cooler with attachment After attaching the G.I. box with desert cooler investigations were made as in the case of desert cooler. Observations and results are depicted in the Table 3. Table 3 Performance of Desert Cooler with Attachment Sr. No Air temperature 0 C Relative humidity (RH) Ambient After cooler Ambient From cooler WBT Effectiveness 1. 2. 3. 39.1 39.4 40 28 28 29 23% 22% 22% 58% 56% 56% 22.3 22 23 66.07% 65.5% 64.7% Average effectiveness is found to be 65.42 %. There is no significant difference is obtained with unloaded condition. Drinking water was the main objective behind designing the present cooling system. Performance of the cooler was taken with drinking water in the G.I. box as well as without attaching the G.I. box with the existing cooler. The cooling curve is shown in Fig. 2. The outside conditions during experiments were observed to be hot and dry (40 deg. C DBT and 17% R.H.). At these conditions, temperature, almost WBT ( 21.2 0 C) has been obtained only in 25 minutes without attachment in contrary to 52 minutes when it is connected to the G.I. box having cooling water 41 as well as drinking water in it. For circulating the cooling water in desert cooler without attachment conventional pump was kept in position whereas in the case of attachment another pump mounted in the G.I. box was in operation. The lag of 27 minutes was due to the load of additional cooling water as well as drinking water. It can be concluded that performance of the desert cooler is affected in terms of time lag but not in terms of minimum temperature obtained by it. As indicated in Fig. 3, the temperature of cooling water in desert cooler as well as in G.I. container reaches to its WBT almost at the same time i.e. 52 minutes after the start of cooler.

5. Performance of Desert Cooler with Drinking Water For domestic use, it is observed that the requirement of drinking water is not continuous. Fig. 4 shows the change in drinking water temperature with time. The cooling water attains its minimum temperature in around 30 to 35 minutes, which is ½ to 1 degree C more than the temperature of water in G.I. container. Comparison of drinking water obtained through the conventional clay pot in Rajasthan is also made and concluded that the temperature of water is significantly lower in the case of copper box. 42

Universal Journal of Environmental Research and Technology 6. Experiments on Vegetables egetables Various experiments are conducted in front copper container by putting vegetables inside it. Cooling curves of various vegetables are drawn to see the time taken by the device to cool vegetables up to the copper per box temperature. For this purpose thermocouples are attached to vegetables. Some vegetables like tomato have hav larger size so the thermocouple is inserted up to the core. The preserved vegetables are shown in photograph. The Figure igure 5 shows the cooling curves for different vegetables. The cooling rate of coriander and cucumber is found to be same whereas the rate of cooling of ladyfinger is different and lower than both the vegetables due to its density. Further, all the vegetables could achieve the temperature of cooling water in around 23-25 minutes. Fig 8 Preservation of Different Vegetables 43

The weights loss of six different vegetables was measured after 2 days and 5 days in container as shown in Fig. 6. Curves are plotted for weight loss v/s time. These weight losses are compared with the weight losses of vegetables in environment. These curves show that there is enormous difference in weight losses of the two. The vegetables lying outside lose weight rapidly as compared to the vegetables kept inside the copper container. Weight loss of chili and coriander is found to be very little whereas cucumber and ladyfinger losses weight rapidly. For the purpose of comparison, weight losses of unpreserved vegetables are indicated in Fig. 7. The observations reveals that the vegetables lying outside losses weight so rapidly that they are not usable after only one day but vegetables lying inside the copper container were good enough to eat even after 5 days. This shows the usefulness of this device to store vegetables 6. Conclusions On the basis of present study, following salient conclusions are drawn 1. The developed cooler can be used for the purpose of storage of vegetables, bakery products, chocolates, medicines etc. including drinking water. The main medicines which can be stored in the temperature range of 22-27 0 C Propecia is the medicine used to treat male pattern hair loss in men only 7. 2. Average effectiveness is found to be 65.42 % which is comparable with unloaded condition. 3. In unloaded condition, WBT ( 21.2 deg. C) has been obtained only in 25 minutes contrary to 52 minutes when it is connected to the G.I. box having cooling water as well as drinking water in it. 4. Developed cooler performs better over its nearest rival i.e. clay pot which is most popular in desert areas for cooling the drinking water. 5. Vegetables can be stored up to five days without any decay in their properties. 6. Around 30W energy can be saved by using the developed attachment with the conventional desert cooler without affecting the performance of the cooler References 1. We Dco Database Version 1.2, Indian Society of Heating, Refrigerating and Airconditioning Engineers, 2000. 2. Ashrae Handbook Fundamentals (2001), Chapter 8 Thermal Comfort. American Society of Heating, Refrigerating and Airconditioning Engineers, Inc. 3. http//www.geda.org.in/e_conserv/ec_ed_ nwc.htm 4. http//www.ecofriend.com/entry/mitticoolthe-most-eco-friendly-refrigerator-evermade/ 5. http//en.wikipedia.org/wiki/evaporative_c ooler 6. Gaffney J.J, Baird C.D. and Eshleman W.D. (1980). Review and analysis of the transient method for determining thermal diffusivity of fruits and vegetables. ASHRAE Transactions Part 2-86 261-280 7. Silva F.V.M. and Silva C.L.M. (1997). Quality optimization of hot filled pasteurized fruit purees container characteristics and filling temperatures. Journal of Food Engineering 32 351-364. 44