Hygienic Air Quality for the Food Industry

Similar documents
DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions

IEQ-15 Air Distribution System

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

HVAC Design Requirements

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

State of the Art Energy Efficient Data Centre Air Conditioning

COARSE DUST FINE DUST GAS ADSORPTION EPA HEPA ULPA Product Catalogue Filters for HVAC Systems and Cleanrooms

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Atlas Copco Quality Air Solutions. Compressed Air Filters

Laminar Flow Cabinets

lindab we simplify construction Air Handling Units Product Overview

RPV - RP - RA air handling units

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

condensation mould high humidity

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process

Mechanical and Natural Ventilation

Energy saving in The air filtration field

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

PANDA SPRAY BOOTH FILTER INFORMATION

JANUARY 2013 GUIDANCE NOTES ON HEATING, VENTILATION AND AIR- CONDITIONING (HVAC) SYSTEMS FOR MANUFACTURERS OF ORAL SOLID DOSAGE FORMS

ASTACEA4 Inspect complex/central air conditioning systems

CLEANROOMS IN PHARMACEUTICAL PRODUCTION

Aerospace and Defence

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Using Portable Spot Air Conditioners in Industrial Applications

CLEAN ROOM MONITORING REGULATORY STANDARDS

Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview

CONDENSATION IN REFRIDGERATED BUILDINGS

Refrigeration systems and solutions for the food industry english

Under sill units. Type FSL-B-ZAS

ThermoSorb Desiccant Dryers

25th DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE

Comparison between Decentralised and Centralised Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems

Paul Pinson. July 15, 1998 July 17, 1998

Energy Efficiency. Bars & RestauRants.

ENVIRONMENTAL MONITORING

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

Federation of European Heating, Ventilation and Air-conditioning Associations

White Paper. Life Sciences Industry Solution Blueprint for Environmental Monitoring Systems (EMS) ISPE Guidance and Best Practices.

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

INDOOR AIR QUALITY ASSESSMENT MOLD INVESTIGATION. Department Of Children and Family 810 Memorial Drive Cambridge, Massachusetts

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

Kompressoren. Adsorption Dryer AD

Mould Mould A Basic Guide

CAC/RCP , Rev

Optimizing machine reliability and overall plant efficiency

Energy Efficiency HOSPITALITY.

DRAFT 8/13/2015. Proposed Addition of Non-Mandatory Appendix FC-B has been withdrawn from publication in the next edition.

Environmental Monitoring

Hygiene Standards for all Food Businesses

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Resources for School Energy Managers

Before You Start an Energy Efficiency Retrofit The Building Envelope

Hazardous Drug. Cleanroom. Standards

Quick wins for energy savings in buildings

HEPA Filters for Pharma Applications Cleanrooms & Safety Applications. Gordon Farquharson June 2012

SIP (STRUCTURAL INSULATED PANEL)

PFT Two stage axial fan The high pressure fan for modern boiler plants

For Components PIERBURG S.A.

SPECIAL APPLICATIONS

Innovent LASER Packaged Fresh Air Conditioning Units

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok Sag 09/1437

- White Paper - Data Centre Cooling. Best Practice

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

FLEXIBLE PACKAGING SOLUTIONS

Mold Response and Remediation Plan

Direct Fresh Air Free Cooling of Data Centres

ASBESTOS ENCLOSURE VENTILATION RESEARCH

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Dust Filtration Catalogue

MOLD RESPONSE AND REMEDIATION PLAN

White Paper: Free Cooling and the Efficiency of your Data Centre

Analysis of HVAC Control Strategies

MOLD REMEDIATION KEY STEPS

LASER CUTTING OF STAINLESS STEEL

ENERGY STAR QUALIFIED HOMES. Assured Performance in Every Qualified Home

Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry

SWIMMING POOL HEAT PUMP

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

World Health Organization WHO Technical Report Series, No. 961, 2011

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Basics of HVAC Cleaning

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Which filter class for supply air is required in a typical HVAC system?

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

Radford University. Indoor Air Quality Management Plan

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

ROOFS, SNOW AND ICE DAMS

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

krones AirCo The air conveyor for PET bottles

GUIDELINE TO THE INSPECTION OF HORMONE PRODUCT MANUFACTURING FACILITIES

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

UV100A Ultraviolet Air Treatment System

Weiss Mobile Air Conditioning Systems

Transcription:

Steve Langford. Global Strategic Market Manager, Food & Beverage TRAINING DOCUMENT

Introduction Short Introduction to Freudenberg Food Quality Standards and Air Quality Guidelines for the Food Industry Ventilation; Why do we need it? What is important? The ventilation survey Filter Systems Optimising your filtration. The importance of pre-filtration. Energy efficient filter systems case study. 2

Freudenberg Group Freudenberg is a family-owned group of companies founded in 1849 offers its customers technically challenging product solutions & services comprises 16 Business Groups operating on various markets in 56 countries around the globe Products: seals, vibration control technology components, nonwovens, release agents and lubricants, household cleaning products, medical components, filtration solutions 2012 2013 2014 Sales (in mill. EUR) 6,322 6,623 7,039 Consolidated profit / loss (in mill. EUR) 433 400 478 Workforce (per 31.12.) 37,453 39,897 40,456 3

Complete filtration know-how: Products, System Solutions, Services Filter mats Pocket filters Cassette filters EPA/HEPA/ULPA filters Gas phase filters Filters for laser printers Diesel exhaust filters Hightemperature filters Filter bags Filter cartridges Cabin air filters Engine intake air filters? Gas phase filtration systems Ventilation systems Food & Beverage Air quality control Food & Beverage Services for gas phase filtration systems Air filtration systems Water filtration systems Viledon filtercair Filtration testing center 4

Reference List. Dairy Bakery / Cereals RTE / Chilled Foods Cooked Meats Beverage Confectionery 5

Standards & Guidelines Hygienic Air Quality for the Food Industry CODEX ALIMENTARIUS Recommended International Code of Practice General Principles of Food Hygiene. CAC/RCP 1-1969, Rev. 4 (2003) 4.4.6 AIR QUALITY AND VENTILATION Adequate means of natural or mechanical ventilation should be provided, in particular to: - minimize air-borne contamination of food - control ambient temperatures - control odours - control humidity Ventilation systems should be designed and constructed so that air does not flow from contaminated areas to clean areas. 6

Food Quality Standards Most Food Quality Standards give little guidance on ventilation and air filtration. Typically state that: Adequate natural and/or artificial ventilation shall be provided. Heating, ventilation and extraction systems must be effective at preventing condensation and excessive dust. A documented risk assessment must be conducted to determine the requirement for air filtration. A system must be in place to maintain positive air pressure from High to non-high areas. Little detail on the how to or even on where to get the information from. 7

Guidelines on Air Quality Need to look to Food Industry Guidelines which give advice on Hygienic Air Quality Control. Recommend; EHEDG - Air Handling Systems in the Food & Beverage Industry 2005 EHEDG (Draft) Air Handling Systems in the Food Industry Air Quality Control for Building Ventilation (2016). EHEDG - Hygienic Design Principles for Food Factories 2014 Campden BRI: Guidelines on Air Quality Standards for the Food Industry 2005 EHEDG - Importance of Zoning in Food Production; Zone B (Basic Hygiene): Prevent product contamination by adopting good manufacturing procedures. Zone M (Medium Hygiene): To control or reduce the creation of hazardous sources that can affect a higher zone classification. Zone H (High Hygiene): To control all product contamination hazards and to protect the interior of food processing equipment from exposure to the room atmosphere. 8

EHEDG: Guidelines on Air Quality Designing Air Movement Systems for the Food Industry Food manufacturing zones showing potential routes of product flow and air flow from areas of higher positive pressure 2014 2015 9

EHEDG: Guidelines on Air Quality Air filter recommendation for environmental and process air Positive air movement from higher to lower zone (controlled over-pressure). Zone B Basic Hygiene Zone M Medium Hygiene 1. Stage M5-F7 1. Stage F7 2. Stage F9 Zone H High Hygiene 1. Stage F7 2. Stage F9 3. E10-H13 (risk dependant) ---- optional essential Temperature control optional essential essential Humidity control ---- Optional (depends on risk assessment) Optional (depends on risk assessment) Minimum air changes per hour to maintain air quality 5 10 Microbiological monitoring (HACCP ) optional recommended essential 10

Ventilation All food factories require ventilation. Air filtration is necessary to ensure the containment of critical working areas. Air can act as a source of contamination; from outside the processing area. as a transport medium, moving contamination from other sources within the processing area. Supply air of a specified quality; Temperature Humidity Particle concentration Quantity (fresh air volume) Hygienic Air Quality is required for; The comfort and safety of employees. Maintain a safe working environment. To reduce the possibility of contamination. To help ensure shelf-life of the product 11

Ventilation It is essential to have continuous room pressure to prevent contamination entering High Hygiene Zones The ventilation system design will be influenced by the level of over pressure and / or number of air changes required. The total number of air changes must be risk assessed based on the size of the area, number of personnel and the equipment used. Room pressurisation and optimised air changes can often provide the required levels of hygienic air quality without the need for high energy consumption cleanrooms. A final filter grade of between F9 and E11, (depends upon the type of product and risk assessment), can give an optimised operational compromise between energy cost, filter lifetime and high hygiene process protection. Aseptic filling and some more critical operations will require HEPA Grade Filtration. 12

Ventilation Ventilation systems can be overlooked. Important to carry out a Hazard analysis (HACCP) to determine the air quality standards required. Company with expertise in ventilation and filtration can give advice on; Condition based monitoring & filter lifetime Filter performance - grade, type, efficiency Air quality survey Air flow mapping Maintenance of ventilation equipment Engineering solutions Air quality documentation for audit purpose. 13

Filter Systems Filter should not be a source of contamination: Moisture resistant. No fibre shedding. Inert no breeding ground for microbial contamination. Synthetic Rigid Filter Construction & assembly of the filter frame: Seals remain intact through lifetime of the filter. Frames are sealed to prevent bypass of air. Fit filter elements able to withstand mechanical stresses during operation. Filter media should remain rigid in turbulent conditions. Remain air-tight & leak free. Correct fitting of filters important. Cheap filters are rarely cost effective. 14

The Importance of Pre-Filtration Typical Pre-filters Cardboard or metal framed panels Inexpensive. Difficult to sealing to the frame. Low dust holding short life. Cardboard frame warps with moisture. High pressure loss. Glass Fibre pocket filters Brittle fibres Danger of fibre shedding Thin nonwoven layer to stop shedding. 15

The Importance of Pre-Filtration Filter Characteristics Synthetic media non-breaking fibres Self supporting pockets. Suitable for operation up to 100% RH. Microbiological inactive. High dust loading High air volume capacities. Number of filtration stages can be reduced, without compromising on air quality / lifetime. Important to have an air-tight seal to filter frames. Filter wall sealed against leakage. 16

Lifetime & Energy Costs A relatively simple and effective method for achieving significant cost reductions is to use high-quality, highly energy efficient air filters. European Committee of Air Handling and Refrigeration Equipment Manufacturers (EUROVENT) developed a European energy efficiency classification system for air filters as part of the EUROVENT Certification. Important you look at systems, not individual filters. An A+ energy efficient filter protected by a G4 Panel means that as a system it has a higher energy consumption than the A+ label implies. An high dust holding A or B energy efficient filter, running without a G4 panel, may actually be more energy efficient. 17

Lifetime & Energy Costs Never compromise Air Quality for Energy Cost Savings 18 Druckdifferenz Pressure drop Filter A Energy saving Filter B Filter replacement Betriebsdauer Time of operation

Lifetime & Energy Costs Case Study Original System G4 Grade, Cardboard Framed Filter, 48mm depth G4 6-8 filters per AHU 250 AHU s across UK Filter change every 6 weeks deterioration of filter seal Contamination of coils and AHU regular cleaning High initial pressure loss, fast pressure development Avg. energy consumption per AHU 65,433 kwh p.a. At 0.08 per kwh = 5,235 p.a. Avg. energy cost of an AHU. 19

Lifetime & Energy Costs Case Study Freudenberg System G4 Grade, Pocket Filter, 330mm depth 6-8 filters per AHU, 250 AHU s Re-engineered framework filter change 12 months Better seal, reduced contamination, less cleaning Low initial pressure loss, slow pressure development Avg. energy consumption per AHU 63,598 kwh p.a. At 0.08 per kwh = 5,087 p.a. Avg. energy cost of an AHU G4 20

Lifetime & Energy Costs Case Study Freudenberg System Maintained same filter grade Extended filter lifetime from 6 weeks to 12 months Cost Saving. Improved filter efficiency better seal to filter frame, no air bypass Improved cleanliness of AHU Reduced requirement for coil and AHU cleaning Cost Saving Maintenance company visits every 6 weeks no longer required Massive Cost Saving Estimated energy savings across 250 AHU s = 37,000 p.a. 21

Thank You